SICK Replacing the I/O module Operating instructions

Type
Operating instructions

SICK Replacing the I/O module

The SICK Replacing the I/O module is a device that allows you to replace the I/O module on your SICK S 3000 safety laser scanner. This can be necessary if the I/O module fails or if you need to upgrade to a different I/O module variant.

The SICK Replacing the I/O module is easy to use. Simply follow the instructions in the manual to remove the old I/O module and install the new one. The device is designed to ensure that the housing is sealed to IP 65, which means that it is protected against dust and water ingress.

SICK Replacing the I/O module

The SICK Replacing the I/O module is a device that allows you to replace the I/O module on your SICK S 3000 safety laser scanner. This can be necessary if the I/O module fails or if you need to upgrade to a different I/O module variant.

The SICK Replacing the I/O module is easy to use. Simply follow the instructions in the manual to remove the old I/O module and install the new one. The device is designed to ensure that the housing is sealed to IP 65, which means that it is protected against dust and water ingress.

8010367/14-04-03 Printed in Germany (04-03) Subject to change without prior notice
©SICK AG Industrial Safety Systems All rights reserved
I/O-Modul tauschen
Anlage spannungsfrei schalten!
Während Sie das I/0-Modul tauschen, könnte die Anlage unbeabsichtigterweise starten.
Schalten Sie grundsätzlich bei allen Arbeiten an Maschine und Sicherheits-Laserscanner die Maschine
spannungsfrei.
Im demontierten Zustand des I/O Moduls sind hoch entwickelte Elektronikkomponenten zugänglich. Schützen Sie
diese vor elektrostatischer Entladung, Verschmutzung und Feuchtigkeit.
Ø Verwenden Sie nach Möglichkeit antistatische Bodenmatten und Werkbankunterlagen.
Ø Berühren Sie bei Arbeiten am S 3000 von Zeit zu Zeit eine unbeschichtete Metallfläche, um statische
Aufladungen von Ihrem Körper abzuleiten.
Ø Entnehmen Sie die Komponenten des S 3000 erst unmittelbar vor der Installation ihren antistatischen
Verpackungen.
Ø Beachten Sie, dass für Schäden, die durch elektrostatische Entladung entstehen, keine Haftung übernommen
werden kann.
Das I/O-Modul darf nur von sachkundigem Personal in sauberer Umgebung getauscht werden.
Montieren Sie das I/O-Modul entsprechend der folgenden Anleitung, um die Gehäusedichtigkeit IP 65 zu
gewährleisten.
So tauschen Sie das I/O-Modul:
Ø Ziehen Sie den Systemstecker ab und demontieren Sie den S 3000.
Ø Bringen Sie den S 3000 an einen sauberen Ort (Büro, Instandhaltungsräume oder Ähnliches).
Ø Reinigen Sie den S 3000 zunächst von außen. Damit verhindern Sie das Eindringen von Fremdkörpern in das
geöffnete Gerät.
Ø Lösen Sie die Befestigungsschrauben des I/O-Moduls.
Ø Greifen Sie das I/O-Modul mit einer Hand in der Vertiefung des Verbindungssteckers zum Systemstecker.
Ø Greifen Sie mit der anderen Hand das I/O-Modul an der Demontagehilfe an der Geräteunterseite.
Ø Ziehen Sie das I/O-Modul parallel zum Montageschacht ab.
Ø Entfernen Sie eventuelle Verschmutzungen von der Dichtfläche und der Anlagefläche des Sensorkopfs.
Verwenden Sie dazu möglichst einen rückstandsfreien Kunststoffreiniger
Ø Entnehmen Sie das I/O-Modul aus der Verpackung, sorgen Sie dabei für ESD-Schutz.
Ø Kontrollieren Sie die Flächen auf Sauberkeit und die Dichtung auf richtigen Sitz.
Ø Setzen Sie das I/O-Modul im Montageschacht auf der Sensorkopf-Rückseite parallel an. Orientieren Sie sich
dabei an den drei umgebenden Seiten des Schachtes.
Ø Führen Sie das I/O-Modul entlang dieser Flächen auf die Steckverbindung. Schieben Sie das I/O-Modul dabei
parallel zur Sensorkopf-Rückseite ein, vermeiden Sie ein Verkanten. Das I/O-Modul kann ohne Kraftaufwand
aufgesteckt werden.
Ø Wenn das I/O-Modul plan zur Sensorkopf-Rückseite anliegt (Abstand ca. 1 mm), ziehen Sie die Schrauben
schrittweise und über Kreuz auf 10 bis 12 Nm an.
So nehmen Sie den S 3000 wieder in Betrieb:
Ø Montieren Sie den S 3000 wieder ordnungsgemäß.
Ø Stecken Sie den Systemstecker des S 3000 auf.
Ø Haben Sie das I/O-Modul gegen die gleiche I/O-Modul-Variante ausgetauscht, liest der S 3000 nach dem
Einschalten die gespeicherte Konfiguration automatisch aus dem Systemstecker.
Ø Haben Sie das I/O-Modul gegen eine andere I/O-Modul-Variante ausgetauscht (z.B. Standard gegen Advanced),
müssen Sie eine Erstinbetriebnahme.
=
ACHTUNG
Hinweis
Hinweise
8010367/14-04-03 Printed in Germany (04-03) Subject to change without prior notice
©SICK AG Industrial Safety Systems All rights reserved
Replacing the I/O module
Switch the entire machine/system off line!
While you are replacing the I/0 module, the plant may start inadvertently.
As a matter of principle, always isolate the machine from the power supply during all work on the
machine and safety laser scanner.
When the I/O module is dismantled, advanced electronic components are accessible. Protect these from
electrostatic discharge, contamination and moisture.
> If possible use anti-static floor mats and workbench covers.
> When working on the S 3000, touch a bare metal surface from time to time to discharge static charging of your
body.
> Only remove the components for the S 3000 from their anti-static packing immediately prior to installation.
> Note that no liability can be accepted for damage caused by electrostatic discharge.
The I/O module is only allowed to be replaced by specialist personnel in a clean environment.
Mount the I/O module as per the following instructions to ensure that the housing is sealed to IP 65.
Replacing the I/O module:
> Disconnect the system plug and remove the S 3000.
> Take the S 3000 to a clean place (office, repair shop or similar).
> First clean the outside of the S 3000. This prevents foreign bodies entering the device when it is opened.
> Undo the fixing screws for the I/O module.
> Take hold of the I/O module with one hand at the recess for the connector to the system plug.
> With the other hand take hold of the I/O module at the dismantling aid on the underside of the device.
> Pull out the I/O module parallel to the mounting shaft.
> Remove any contamination from the sealing surface and the mating surface for the sensor head. For this purpose
if possible use a plastic cleaner that does not leave residues
> Remove the I/O module from the packaging, ensure that you take adequate ESD protection measures during this
process.
> Check the surfaces for cleanliness and the seal for correct seating.
> Insert the I/O module in the mounting shaft parallel to the rear of the sensor head. During this process use the
three surrounding sides of the shaft for orientation.
> Guide the I/O module along these surfaces to the connector. During this process slide the I/O module parallel to
the rear of the sensor, avoid tilting. The I/O module can be connected without the need to apply force.
> When the I/O module is flat against the rear of the sensor head (distance approx. 1 mm), tighten the screws in
stages, diagonally, to 10 to 12 nm.
Re-commissioning the S 3000:
> Correctly re-mount the S 3000.
> Connect the S 3000 system plug.
> If you have replaced the I/O module for the same I/O module variant, after power up the S 3000 automatically
reads the saved configuration from the system plug.
> If you have replaced the I/O module with a different I/O module variant (e.g. Standard with Advanced), you must
perform initial commissioning
=
WARNING
Note
Notes
  • Page 1 1
  • Page 2 2

SICK Replacing the I/O module Operating instructions

Type
Operating instructions

SICK Replacing the I/O module

The SICK Replacing the I/O module is a device that allows you to replace the I/O module on your SICK S 3000 safety laser scanner. This can be necessary if the I/O module fails or if you need to upgrade to a different I/O module variant.

The SICK Replacing the I/O module is easy to use. Simply follow the instructions in the manual to remove the old I/O module and install the new one. The device is designed to ensure that the housing is sealed to IP 65, which means that it is protected against dust and water ingress.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI