LG SP182CM Owner's manual

Type
Owner's manual

This manual is also suitable for

OWNER’S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
P/NO:MFL68070403
www.lg.com
SP242CM
U56
TYPE:WALL MOUNTED
MODELS
SP182CM
U56
SP242CM
N56
SP182CM
N56
ENGLISH
ESPAÑOL
2 Room Air Conditioner
Room Air Conditioner Owner’s Manual
TABLE OF CONTENTS
Display Luminosity(Optional) ..............15
Energy-Saving Cooling Model ............15
........................................16
To Cancle The Timer Setting...............16
Sleep Mode Operation ........................16
......................
Jet Cool
Operation...............................17
Forced Operation.................................17
E. Maintenance and Service..................18
Indoor Unit...........................................18
Outdoor Unit ........................................20
Operation Tips!....................................20
Self-Diagnosis Function ......................20
Troubleshooting Tips!
Save time and money!.........................21
Call the service immediately in the
following situations ..............................21
Spec sheet...........................................22
A. Safety Precautions ..............................3
B. Electrical Safety...................................6
Temporary Use of an Adapter ...............6
Temporary Use of an Extension Cord ...6
Symbols used in this Manual.................6
C. Product Introduction...........................7
Indoor Units ...........................................7
Operation Indication Lamps ..................8
Outdoor Unit ..........................................8
D. Operating Instructions........................9
How to insert the Batteries ....................9
Wireless Remote Controller
Maintenance..........................................9
Operating Method..................................9
Wireless Remote Controller
Operation Mode...................................12
.....13
Air Circulation Operation
.....................14
Auto Clean Operation..........................14
Cooling Only Model ..........................10
Wireless Remote Controller
Heat Pump Model .............................11
Horizontal Vane Control
17
Auto Operation.....................................13
Healthy Dehumidification Operation
Timer Setting
Setting the Current Time......................15
FOR YOUR RECORDS
Write the model and serial numbers here:
You’ll find many answers to common problems in the
Inside you will find many helpful hints on how to use
You can find them on a label on the side of each unit.
Model #
Serial #
Dealer's Name
Date Purchased
Staple your receipt to this page in the event you need
it to prove date of purchase or for warranty issues.
READ THIS MANUAL
and maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips
for service at all.
first, you may not need to call
PRECAUTION
Contact the authorized service technician for
repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by
young children or invalids without supervision.
• Young children should be supervised to ensure
that they do not play with the air conditioner.
• When the power cord is to be replaced,
replacement work shall be performed by
authorized personnel only using only genuine
replacement parts.
This appliance is not intended for use by persons
(including children) with reduced physical,sen-
sory or mental capabilities, or lack of experience
and knowledge, unless they have been given su-
pervision or instruction concerning use of the
appliance by a person responsible for their safety.
Children should be supervised to ensure that they
do not play with the appliance.
WARNING: Before accessing the terminals, all
power circuits must be disconnected.
WARNING: Fixed installations will incorporate
disconnect means in accordance with
installation rules.
WARNING: This device will not be accessible to
public.
WARNING: The appliance must be installed in
accordance with national regulations
for electrical installations.
Plug in the power plug properly.
Otherwise, it will cause electric shock or fire due to heat generation or electric shock.
Do not operate or stop the unit by inserting or pulling out the power plug.
Do not operate with wet hands or in damp environment.
Do not direct airflow at room occupants only.
Do not allow water to run into electric parts.
Do not use the socket if it is loose or damaged.
Do not open the entrance during operation.
Always perform grounding work.
Always install air leakage breaker and a dedicated switching board.
Unplug the unit if strange sounds,smell,or smoke comes from it.
It will cause electric shock or fire due to heat generation.
In the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly
Do not damage or use an unspecified power cord.
It will cause electric shock or fire.
It will cause electric shock or fire due to heat generation.
It may cause electric shock.
It may cause failure of machine or electric shock.
No grounding may cause electric shock.
No installation may cause fire and electric shock accident.
It may cause fire and electric shock accident.
It may cause fire and electric shock.
It may cause electric shock.
This could damage your health.
Do not modify power cord length or share the outlet with other appliances.
quallfied order to avoid a hazard.(Y Attachment)
ENGLISH
There is risk of fire or electric shock.
Avoid personal injury.
It may cause corrosion on the product.
A bad connection may cause water leakage.
Install the drain hose to ensure that the condensed water is drained away properly.
Do not use the telephone or turn switches on or off. There is risk of explosion or fire.
product on.
Two or more peopie must lift and transport the product.
Do not install the product where it will be exposed to sea wind (salt spray) directly.
Do not place ANYTHING on the power cable.
Do not plug or unplug the power supply plug to turn the unit ON/OFF.
When flammable gas leaks, turn off the gas and open a window for ventilation before turn the
Harsh detergent may also cause failure of product, fire, or electronic shock.
Do not use harsh detergent that causes corrosion or damage on the unit.
For inner cleaning, contact an Authorized Service Center or a dealer.
Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly
so that there is no force pulling the cable from the connection terminals.
Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after
Improper or loose connections can cause heat generation or fire.
Make sure to check that the power cable plug is not dirty, loose or broken and then only insert the
Children may play with them and cause injury.
Incorrect refrigerant used can prevent the normal operation of the unit.
Don’t use a power cord, a plug or a loose socket which is damaged.
Otherwise it may cause a fire or electrical shock.
Do not touch, operate, or repair the product with wet hands. Hold the plug by hand when taking out.
Do not place a heater or other heating appliances near the power cable.
Do not allow water to run into electric parts.Install the unit away from water sources.
Do not store or use or even allow flammable gas or combustibles near the product.
Do not use the product in a tightly closed space for a long time. Perform ventilaion regularly.
Do not open the front grille of the product during operation. (Do not touch the electrostatic filter, if
If strange sounds, smell or smoke comes from product. Immediately turn the breaker off or
Be sure to check the refrigerant to the used. Please read the label on the product.
Dirty, loose or broken power plug can cause electric shock or fire.
plug completely.
installation or svc and then tear away and thraw away the plastic packaging bags.
There is risk of electric shock or fire.
There is risk of fire and electric shock.
There is risk of electric shock or fire.
There is risk of electric shock.
There is risk of product damage or failure, or unintended operation.
There is risk of fire or electric shock.
There is risk of fire or electric shock.
This could result in personal injury and product damage.
Take care to ensure that nobody especially kids could step on or fall onto the outdoor unit.
Take care to ensure that power cable could not be pulled out or damaged during operation.
breaker.
When the product is not to be used for a long time, disconnect the power supply plug or turn off the
element etc.
Turn the main power off and unplug the unit when cleaning or repairing the product.
There is risk of fire, failure of the product, or electric shock.
There is risk of fire.
There is risk of physical injury, electric shock, or product failure.
the unit is so equipped.)
disconnect the power supply cable.
Ventilate the product room from time to time when operating it together with a stove, or heating
Oxygen deficiency could occur and hence harm your health.
Oxygen deficiency can occur and hence harm your health.
It may cause a problem for your neighbors and hence dispute.
Low refrigerant levels may cause failure of product.
There is risk of damage or loss of property.
It may cause product failure.
Do not touch the metal parts of the product when removing the air filter.
Do not step on or put anyting on the product. (outdoor units)
Always insert the filter securely after cleaning. Clean the filter every two weeks or more often if
Be cautious when unpacking and installing the product.
If the refrigerant gas leaks during the repair, do not touch the leakaing refrigerant gas.
There is risk of fire, electric shock, or damage to the plastic parts of the product.
There is risk of personal injury.
necessary.
There is risk of personal injury and failure of product.
There are sharp and moving parts that could cause personal injury.
A dirty filter reduces the efficiency.
Sharp edges could cause injury.
Do not tilt the unit when removing or uninstalling it.
Do not mix air or gas other than the specified refrigerant used in the system.
The refrigernat gas can cause frostbite (cold burn)
The condensed water inside can spill.
damage or injury.
Replace the all batteries in the remote control with new ones of the same type. Do not mix old and
accordance with local and national standards.
If the refrigerant gas leaks during the installation, ventilate the area immediately.
Dismantling the unit, treatment of the refrigerant oil and eventual parts should be done in
If air enters the refrigerant system, an excessiveiy high pressure results, causing equipment
Otherwise it can be harmfull for your health.
There is risk of fire or product failure.
There may bum or explode.
Moisture may condense and wet or damage furniture.
This could harm to your health.
It is not sanitary and could cause serious health issues.
Be careful and avoid personal injury.
The chemicals in batteries could cause burns or other health hazards.
use the remote if the batteries have leaked.
window is left open.
Do not expose your skin or kids or plants to the cool or hot air draft.
Do not drink the water drained from the product.
Use a firm stool or ladder when cleaning, maintaining or repairing the product at an height.
Do not let the air conditioner run for a long time when the humidity is very high and a door or a
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not
new batteries or different types of batteries.
Do not recharge or disassemble the batteries. Do not dispose off batteries in a fire.
Do not insert hands or other objects through the air inlet or outlet while the product is operating.
consumer air conditioner, not a precision refrigeration system.
Do not block the inlet or outlet of air flow.
Use a soft cloth to clean. Do not use harsh detergents, solvents or splashing water etc.
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a
Always check for gas (refrigerant) leakage after installation or repair of product.
To avoid vibration or noise.
the neighborhoods.
Do not install the product where the noise or hot air from the outdoor unit could damage or disturb
Keep level even when installing the product.
ENGLISH
WARNING: Before accessing the terminals, all power circuits must be disconnected.
WARNING: This device will not be accessible to the public.
WARNING: The appliance must be installed in accordance with national regulations for electrical
installations.
6 Room Air Conditioner
Electrical Safety
Electrical Safety
• This appliance must be properly grounded.
To minimize the risk of electric shock, you must alway plug into a grounded oulet.
• Do not cut or remove the grounding prong from the power plug.
• Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance
unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the
house wiring.
• If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and
circuit checked by a qualified electrician.
We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections,
use only a genuine adapter, available from most local hardware stores. Ensure that the large slot in the
adapter is aligned with the large slot in the receptacle for a proper polarity connection.
To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground
terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.
• Never use the appliance with a broken adapter.
We strongly discourage the use of an extension cord due to potential safety hazards.
Temporary Use of an Adapter
Temporary Use of an Extension Cord
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the
air conditioner.
This symbol indicates special notes.
NOTE
Symbols used in this Manual
This appliance should be installed in accordance with national wiring regulations. This guide acts as a
guide to help to explain product features.
Owner's Manual 7
Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your
indoor unit type.
Product Introduction
Product Introduction
Standard Split Type
Art Cool Type Wide
Display panel LED indicators
Indoor Units
Art Cool Deluxe(Type 1)
Display panel LED indicators
ENGLISH
Signal receiver
Front panel
Air discharge
Power cord
ON/OFF button
Plasma filter
Air inlet
Air filter
Art Cool Deluxe(Type 2)
Display panel LCD indicators
Signal receiver
Front panel
Air discharge
ON/OFF button
Power cord
Plasma filter
Air inlet
Air filter
Air Inlet
Signal Receptor
ON/OFF Button
Front Panel
Air Filter
8 Room Air Conditioner
Product Introduction
Air intake vents
Air outlet vents
Connecting
wires
Refrigerant pipes
Drain hose
Base plate
On/Off
: Lights up during the system operation, error code and auto restart setting.
Sleep mode : Lights up during sleep mode auto operation.(non-Inverter Model)
Plasma : The function illustrates its dynamic mode by using a multiple lighting system.
Timer
: Lights up during timer operation.(non-Inverter Model)
Lights up during timer operation or sleep mode auto operation (Inverter Model only)
Defrost mode
Power Display : Indicates the setting temperature and operation mode.
: Lights up during defrost mode or hot start operation (Heat pump model only)
: Lights up during outdoor unit operation. (Cooling model only)
Outdoor unit
operation
OUT
DOOR
! Hot start operation: Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out
from unit.
! In defrost mode unit stops heating operation for few minutes to remove formation of ice on the heat
exchanger coils to maintain the efficiency.
Operation
mode
Shape of
display
Setting
temperature
Standard Too hot Hot Cold Too cold
Jet
Cool/Heat
Test
operation
Auto
clean
Comfortable
Auto operation mode
Cooling, heating,
Dehumidification
Mode
Energy-saving
cooling mode
Outdoor Unit
Operation Indication Lamps
1.
Choose a suitable place where its safe & easy to reach.
2. Fix the holder to wall etc with the supplied
screws firmly.
3. Slide the remote controller inside the holder.
1. Remote controller should never be exposed to
direct sunlight.
2. Signal transmitter & receiver should always be
clean for proper communication. Use a soft
cloth to clean them.
NOTE
Operating Instructions
How to insert the Batteries
Wireless Remote Controller Maintenance
1. Remove the battery cover by pulling it according to the arrow direction.
2. Insert new batteries making sure that the (+) and (-) of battery are
installed correctly.
3. Reattach the cover by sliding it back into position.
1. Always use/replace both batteries of same type.
2. If the system is not to be used for a long time, remove the batteries to
save their working life.
3. If the display screen of remote controller starts, fading replace both of
the batteries.
4. Use 2 AAA(1.5 volt) batteries.
NOTE
3. In case some other appliances also get operated with remote control, change their position or consult
your serviceman.
1. The signal receiver is inside the unit.
2.
Aim the remote controller towards the unit to operate it. There should not be any blockage in between.
Operating Method
Owner's Manual 9
Operating Instructions
ENGLISH
Room Air Conditioner 10
ENGLISH
Operating Instructions
• Reset (display): When you press the reset button, all the functions shown on the screen of remote
controller (above image), will be visible on the display. But some of these functions are optional for
your product and may not actually function.
Wireless Remote Controller (Cooling Only Model)
Display screen
Control panel
JET
COOL
JET
COOL
* Some functions may not be supported, depending on the
model.
Control
panel
Display
screen
Description
Fan button : Air come out from the
indoor unit below to the room without
air temperature change.
Sleep mode auto button*: Sets the
sleep mode auto operation.
Temperature adjustment buttons:
Adjusts the room temperature when
cooling and heating.
On/Off button: Turns the power
on/off.
-
-
-
Indoor fan speed button: Adjusts the
fan speed.
Operation mode selection button*:
Selects the operation mode.
Cooling operation ( ) /
Auto operation ( ) /
Dehumidifying operation ( )
Jet cooling*:
cools down the indoor
temperature within a short period of
time.
Air flow direction button: Adjusts the
air flow direction vertically.
Temperature display button: Displays
the room temperature. Press for
5 sec, conversion °C / °F
Timer button: Sets the current time
and the start / end time.
Navigation and functions button*:
Adjusts the time and sets the special
functions.
: Auto clean / : Operates energy
saving cooling
Set/clear button: Sets or cancels
functions.
Reset button : Resets the remote
control settings.
LIGHT button: Adjusts the brightness
of the indoor unit display.
Owner's Manual
11
Operating Instructions
Wireless Remote Controller (Heat Pump Model)
• Reset (display): When you press the reset button, all the functions shown on the screen of remote
controller (above image), will be visible on the display. But some of these functions are optional for
your product and may not actually function.
Display screen
Control panel
JET
COOL
JET
COOL
* Some functions may not be supported, depending on the
model.
Control
panel
Display
screen
Description
Fan button : Air come out from the
indoor unit below to the room without
air temperature change.
Sleep mode auto button*: Sets the
sleep mode auto operation.
Temperature adjustment buttons:
Adjusts the room temperature when
cooling and heating.
On/Off button: Turns the power
on/off.
-
-
-
Indoor fan speed button: Adjusts the
fan speed.
Operation mode selection button*:
Selects the operation mode.
Cooling operation (
) /
Auto changeover (
) /
Dehumidifying operation (
) / Heating
operation ( )
Jet cooling*:
cools down the indoor
temperature within a short period of
time.
Air flow direction button: Adjusts the
air flow direction vertically.
Temperature display button: Displays
the room temperature. Press for
5 sec, conversion °C / °F
Timer button: Sets the current time
and the start / end time.
Navigation and functions button*:
Adjusts the time and sets the special
functions.
: Auto clean / : Operates energy
saving cooling
Set/clear button: Sets or cancels
functions.
Reset button : Resets the remote
control settings.
LIGHT button: Adjusts the brightness
of the indoor unit display.
ENGLISH
Heating
(Heat pump model only)
Dehumidification
Auto
Operation
Cooling
Press the ON/OFF BUTTON to turn the unit on.
The unit will respond with a beep.
Press the operation mode button. Each time the button is pressed,
the operation mode is shifted in the direction of the arrow.
For cooling operation set the desired indoor temperature by
pressing the ROOM TEMPERATURE SETTING BUTTONS.
For cooling the temperature can be set within 18°C~30°C and
Set the fan speed with the remote controller. You can select the fan speed.
1
2
3
4
Natural wind
For fresher feeling, press the INDOOR FAN SPEED SELECTION BUTTON and set to Natural wind mode.
In this mode, the wind blows like a natural breeze by automatically changing fan speed.
Operation Mode
12 Room Air Conditioner
Operating Instructions
for heating the temperature range is 16°C~30°C.
Step1(Low) Step2(Medium) Step3(High)Natural Wind
Owner's Manual 13
Operating Instructions
During Healthy Dehumidification Operation
If you select the dehumidification mode on the OPERATION MODE
SELECTION BUTTON, the product starts to run the dehumidification
function.
It automatically sets the room temperature and airflow volume to the best
condition for dehumidification, based on the sensed current room
temperature.
In this case, however, the setting temperature is not displayed on the remote
controller and you are not able to control the room temperature either.
During the healthy dehumidification function, the fan speed is automatically
set according to the optimization algorithm responding to the current room
temperature status, so that the room condition is kept healthy and
comfortable even in the very humid season.
Healthy Dehumidification Operation
<For Cooling Model>
The temperature and fan speed are automatically set by the electronic
controls based on the
actual room temperature.
If you feel hot or cold, press TEMPERATURE SETTING buttons for more
cooling or heating effect.
You cannot switch the indoor fan speed. It has already been set by the
Auto Operation Mode rule.
Auto Operation
Code Description
2 Cool
1 Cool slightly
0 Maintain
room
temperature
-1 Heat slightly
-2 Heat
You can set desired temperature and indoor fan speed.
Setting Temp. Range : 18~30°C.
: You can not set the actual setting temperature and the fan
speed in this operation mode. But you can use the Auto swing
in this operation. If the system is not operating as desired,
switch manually to another mode
NOTE
<For Heating Model>
ENGLISH
14 Room Air Conditioner
During Auto Clean Operation, moistures left in indoor units after cooling operation or healthy
dehumidification operation can be removed.
Select Auto Clean Operation by the function setting button( ) .
Now whenever the unit is turned off, the indoor fan is still running
for about 30 minutes internally without cooling or dehumidification
operation. This function dries up any remains of moisture & cleans
the unit internally. If you push the Auto Clean button again, this
function is cancelled.
During Auto Clean fuction, only ON/OFF button, Plasma button, Auto Clean
button is used. During this operation, 'Cooling' lamp lights up.
NOTE
Auto Clean Operation
This operation circulates the air without cooling. It can be activated
by pressing the OPERATION MODE SELECTION BUTTON. Once
the air circulation is activated you can select the fan speed by
pressing the INDOOR FAN SPEED SELECTION BUTTON.
Air Circulation Operation
Operating Instructions
Owner's Manual 15
Operating Instructions
Energy-Saving Cooling Mode
Energy-saving cooling mode can save energy in cooling operation, because it can operate efficiently by
setting body-adaptation time according to the change of time and temperature and adjusting desired
temperature automatically.
1. Press the ON/OFF BUTTON to start the unit.
2. Select cooling operation.
3. Press the ENERGY-SAVING COOLING MODE BUTTON.
4. To cancel the energy-saving cooling mode, press the ENERGY-SAVING
COOLING MODE BUTTON again and unit will operate in previous
mode(Cooling mode), but temperature remains 22°C.
Display Luminosity
The unit display Luminosity can be adjusted by using the remote controller.
Press the LED LUMINOSITY button.
Display LED will be dark. Press the button again to set bright display.
Press the SET CLEAR BOTTON For 3 seconds.
Press the TIMER SETTING BUTTONS until the desired time is set.
Check the indicator for a.m. and p.m.
NOTE
Setting the Current T ime
2
Press the SET/CLEAR button.
3
1
ENGLISH
16 Room Air Conditioner
To cancel the timer setting
Timer Setting
Press the SLEEP Button to set the time, you can adjust the time by pressing Setting Button.
Press the SET/CLEAR BUTTON
SLEEP MODE AUTO BUTTON 1 to 7 times. The sleep mode is available for 1 to 7 hours.
• The sleep mode will operate indoor fan at super low speed in cooling mode for pleasant sleep.
In cooling mode or healthy dehumidification mode:
The setting temperature will rise automatically two times by 1°C over next consecutive 30 minutes
(Maximum 2°C) for a comfortable sleep. This will be the final setting temperature as long as sleep mode is
functioning.
NOTE
Sleep Mode Operation
Press the Timer button once to set on the
Reserved 'On' or 'Off'.
1
Press the Time Setting buttons until the
desired time is set.
2
Press the SET/CLEAR BUTTON
3
Description
Button on the
Indication on the LCD Display
Remote Controller
• If you wish to cancel all timer setting, press the SET/CLEAR button.
Operating Instructions
Owner's Manual 17
ON/OFF
button
Operating Instructions
ENGLISH
1. To adjust the direction of the air flow horizontally, press
i
repeatedly and select the desired
direction.
- Select
H
to adjust the direction of the air flow automatically.
2. To adjust the direction of the air flow vertically, press
j
repeatedly and select the desired direction.
- Select
I
to adjust the direction of the air flow automatically.
Horizontal Vane Control
Jet Cool Operation
Jet cool function can be used to cool the room quickly in hot summer. When this
function is turned on, the air conditioner runs in cooling operation mode with super
high fan speed and 18°C setting temperature for 30 minutes for fast and effective
cooling.
You can activate this operation by pressing the JET COOL BUTTON.
To change from jet cool mode to high fan speed cooling mode, press the JET COOL BUTTON or
INDOOR FAN SPEED SELECTOR BUTTON or the ROOM TEMPERATURE SETTING BUTTON again.
• Jet Cool operation cannot be activated during Air Circulation operation.
NOTE
• Adjusting the air flow direction vertically may not be supported, depending on the model.
• Adjusting the air deflector arbitrarily may cause product failure.
• If you restart the air conditioner, it starts to operate with the previously set direction of air flow, so the air
deflector may not match the icon displayed on the remote control. When this occurs, press
i
or
j
to
adjust the direction of the air flow again.
NOTE
JET
COOL
Forced operation
Forced operation is used when the remote controller can't be used. The operation will be started if the ON/OFF
button is pressed. If you want to stop the operation, re-press the button.
Heat pump Model
Cooling Model
Room Temp. 24°C 21°C Room Temp. < 24°C Room Temp. < 21°C
Operating mode Cooling Cooling Healthy Dehumidification Heating
Indoor FAN Speed
High High High High
Setting Temperature
22°C 22°C 23°C 24°C
Maintenance and Service
Indoor Unit
Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and
unplug the power cord.
Clean the unit with a soft dry cloth. Do not use bleach or abrasives.
Never use any of these
• Water hotter than 40°C. It may cause deformation and discoloration.
• Volatile substances. They may damage the surface of the air conditioner.
Air Filters
The air filters behind the front panel / grill should be checked and
cleaned once in every 2 weeks or more often if necessary. To
remove the filters see the self explanatory diagrams for each
model type. Clean the filters with a vacuum cleaner or warm
soapy water. If dirt is not easily removed, wash with a solution of
detergent in luke warm water. Dry well in shade after washing and
reinstall the filters back in place.
Plasma Filters (Optional)
The plasma filters behind the air filter should be checked and
cleaned once in every 3 months or more often if necessary. To
remove the filters see the self explanatory diagrams for each
model type. Clean the filters with a vacuum cleaner. If it is dirty
wash it with water and dry well in shade an install back in place.
G
a
s
o
l
i
n
e
P
o
w
d
e
r
18 Room Air Conditioner
Maintenance and Service
Do not washed the 3M filter with water, because the filter can be damaged.
MULTI Protection Filter
The multi protection filter behind the air filter should be checked and
cleaned once in every 1 month or more often if necessary. To remove the
filters see the self explanatory diagrams for each model type. Clean the filters with
a vacuum cleaner. Do not wash the multi protection filter with water, because the filter
can be damaged. And then insert the filter into original position.
We suggest changing multi protection filter every 6 months.
The location of the filters may differ, depending on the model.
If you need more filters,please contract the LG service center
(refer to the warranty card,)
Pull out the multi protection filter from the separately packed plastic bag.
Installation of new multi protection filter
Insert the multi protection filter into the case.
Multi protection filter is installed with 3M Mark front.
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature
and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller
sets.
If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1
'beep'. If you want to stop the operation, re-press the button.
1. Deluxe (Type 1):
Open the upside of the panel and lift it up as shown. The hooks of the panel will come off. Remove the
air filters. Then pull out the plasma filter
2. Deluxe (Type 2):
Open the front panel as shown.
Then pull the filter tab slightly forward to remove the air filter.
After removing the air filter remove the plasma and deodorizer filter by slightly pulling forward.
After cleaning and drying well reinstall the filters in their original position.
Front panel
Panel hook
Plasma filter
Plasma filter
Front panel
3. Standard Split Type : Two different methods to open the front panel based on types of air
conditioner as below ;
Type 1: Open the front panel as shown.
Then pull the filter tab slightly forward to remove the air filter.
After removing the air filter remove the plasma and 3M multi protection filter by slightly pulling
forward.
How to use the front panel
1. Front panel closing
Move the link upward and close the front panel.
2. Front panel removing
Raise the link up to hook hanger and remove
front panel forward.
Plasma filter
(optional)
MULTI
protection filter
Owner's Manual 19
Maintenance and Service
Removal of Filters
Don't touch this plasma filter within 10 seconds after opening the inlet grille, it may cause an electric shock.
ENGLISH
Outdoor Unit
The heat exchanger coils and panel vents of the outdoor unit should be checked regularly.
If clogged with dirt or soot, the heat exchanger
and panel vents may be professionally steam cleaned.
Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs.
NOTE
Operation Tips!
Self-Diagnosis Function
Error Display LED ( )
Check Point
• Indoor room temperature thermistor open/short.!
• Indoor pipe temperature thermistor open/short.
(once)
3 sec 3 sec 3 sec
This unit has an inbuilt error diagnosis capability. Unit LED( ) will blink in case if thermistor fails.
Please contact your serviceman/dealer in such a situation
Do not overcool the room.
This is not good for the health and
wastes electricity.
Keep blinds or curtains
closed.
Do not let direct sunshine enter
the room when the air conditioner
is in operation.
Keep the room temperature
uniform.
Adjust the vertical and horizontal
airflow direction to ensure a
uniform temperature in the room.
Make sure that the
doors and windows
are shut thight.
Avoid opening doors and
windows as much as
possible to keep the cool
air in the room.
Clean the air filter
regularly.
Blockages in the air filter
reduce the airflow and
lower cooling and
dehumidifying effects.
Clean at least once every
two weeks.
Ventilate the room
occasionally.
Since windows are kept
closed, it is a good idea
to open them and
ventilate the room now
and ten.
Use high fan speed
for effective and fast
cooling.
The unit gives its rated
cooling capacity when the
fan speed is high.
Don't touch this plasma filter within 10 seconds after opening the inlet grille, it may cause an electric shock.
Type 2: Pull the front panel from both sides as shown.
Then pull the filter tab slightly forward to remove the filter. After removing the air filter remove
the plasma and triple deodorizer filter by slightly pulling forward.
Plasma filter
Deodorizer
filter
20 Room Air Conditioner
Maintenance and Service
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45

LG SP182CM Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages