Arrowhead PK1390LFLW User manual

  • Hello! I am an AI chatbot trained to assist you with the Arrowhead PK1390LFLW User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
• Freezeprotectioncombinedwithhealth
protectionfrompossiblecontaminated
watersourcescausedbyback-
siphonageorbackow.
• Waterautomaticallyself-drainsupon
watershutoff,EVENWHENATTACHED
TOFROST-FREEWALLORGROUND
HYDRANTS.
• Foruseonwallhydrantsandburiedyard
hydrants
IAPMO Listed A.S.S.E. 1011 Pat# 5,228,471
Self-Draining
Vacuum Breaker
59 Series
Arrowhead Brass & Plumbing, LLC
4900 Alhambra Ave., Los Angeles, CA 90032
Phone : 323.221.9137 Fax : 323.221.2579
www.arrowheadbrass.com
(MKT-TS-12)Rev.04/2012
Made in USA
Available with breakaway set screw
for vandal resistance.
IMPORTANT:
Foroptimumfreeze
protection,vacuum
breakershouldbeatan
angletolevelground.
Freeze Protection
• Waterfromwallhydrantwilldrain
inasteadygentlestreamfor
approximately15-20secondsafter
hydrantisturnedoff.
• Waterinburiedgroundhydrantswill
draindownandouttheweephole
afterwatershutoff.
Health Protection
• Intheeventofbacksiphonage
duetoadropininletpressure,
thevacuumbreakerwillintake
airthroughtheportstobreakthe
siphoningaction.
• Anywatertryingtomakeitsway
backtothepotablewatersupply
duetobacksiphonageorback
pressurewillbeblockedatthe
pointofthebackowpreventer/
vacummbreakeranddrain
harmlesslytothegroundthrough
theairports.
WARNING! When using a hose with a self-closing nozzle, always relieve pressure
by draining the hose upon water shutoff to activate the drainage of the hydrant.
P
r
o
d
u
c
t
s
A
r
r
o
w
h
e
a
d
B
r
a
s
s
3
3
year
Limited
warranty
Model # Descripon
59ABP
Self-Draining Vacuum Breaker 59
59ABPCHR
Self-Draining Vacuum Breaker 59, Nickel Plated
59BFP
Self-Draining Vacuum Breaker 59 with Fine
Thread Inlet, Rough Brass
59BFPCHR
Self-Draining Vacuum Breaker 59 with Fine
Thread Inlet, Nickel Plated
PK1380
Replacement Self-Draining Vacuum Breaker
(59BFP- Fine Thread) for Arrowhead models
with BFPSD aer part number, Rough Brass
PK1390
Replacement Self-Draining Vacuum Breaker
(59BFPCHR- Fine Thread) for Arrowhead
models with BFPSD aer part number, Nickel
Plated
Available with Standard
Female Hose Thread Inlet
(ABP Models) and Fine
Thread (BFP Models)
Available in Rough Brass or
Nickel Plated (CHR models)
1011
/