Elementi OFG145RWLP User guide

Category
Fireplaces
Type
User guide
Manual No.:ALPE11EN-G145-A2
! !
!
!
!
IMPORTANT
WARNING
WARNING
WARNING
DANGER
SAVE THESE
INSTRUCTIONS
For outdoor use only. DO NOT use
for cooking. DO NOT use under any
overhead enclosure.
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appliance and
immediately call your gas supplier or fire department.
If the information in this manual
is not followed exactly, a fire or
explosion may result causing
property damage personal injury
or loss of life.
Installation and service must be
performed by a qualified installer,
service agency or gas supplier.
Improper Installation, adjustment,
alteration, service or maintenance
can cause injury or property
damage.
Read the installation, operation
and maintenance instructions
thoroughly before installing or
servicing this equipment.
Save these instructions for
future reference. If you are
assembling this unit for someone
else, give this manual to him or her
to read and savefor future
reference.
!
US
R
C
!
ELEMENTI
THE ART OF FIRE
OFG145LP
Manchester Table - Owner's Manual
Gas type: Propane
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
An LP-cylinder not connected for use should not be
stored in vicinity of this or any other appliance.
!
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide
which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed
space such as a camper, tent, car or home.
!
WARNING
California Proposition 65:
Combustion by-products produced when using this product contain chemicals known to be State
of California to cause cancer, birth defects, and reproductive harm.
Wash your hands after handing this product.
Handing the brass material on this product exposes you to lead, a chemical known to the State of
California to cause cancer, birth defects, or reproductive harm.
Important Safety Information -------------------------------------------------------------------- 3
Propane (LP) Dangers and Warnings ----------------------------------------------------------5
Hose & Regulator Assembly and Replacement ---------------------------------------------7
Parts List ----------------------------------------------------------------------------------------------8
Assembly Instructions ---------------------------------------------------------------------------- 9
Lighting Instructions ------------------------------------------------------------------------------13
Care and Cleaning --------------------------------------------------------------------------------14
Gas Component Checks ----------------------------------------------------------------------- 15
Troubleshooting -----------------------------------------------------------------------------------17
Warranty -------------------------------------------------------------------------------------------- 19
TABLE OF CONTENTS
2 / 20
3 / 20
IMPORTANT SAFETY INFORMATION
!
WARNING FIRE TABLE IS FOR OUTDOOR USE ONLY
IF YOU SMELL GAS
• Shut off gas supply to the fire table.
• Extinguish any open fame.
• Do not try lighting any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone.
• Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
WARNING Failure to follow the dangers, warning and cautions in this manual may result in
serious bodily injury or death, or in a fire or an explosion causing damage to property.
IMPORTANT NOTICE Read and understand all warnings and precautions prior to assembly and
use of your gas fire table. Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage.
• Note The use and installation of this product must conform to local codes. In the absence of local
codes, use the National Fuel Gas Code, ANSI Z21.97. Reference to Natural Gas and Propane
Installation code CSA B149.1 or Propane Storage and Handling code B149.2.
•Minimum Clearance from Unit to Combustible Materials 72”(182.9cm) from the top; 48” (121.9
cm) from all sides and back. Do not locate this fire table under any overhead enclosure.
• This gas fire table and its individual shut off valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2 of psi
(3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its
individual manual shut off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
• Keep these instructions for future reference. If you are assembling this unit for someone else,
give this manual to him or her to read and keep for future reference.
• This gas fire table must be used ONLY outdoors in a well-ventilated space and shall NOT be
used inside a building, garage, or any other enclosed area.
• DO NOT use this outdoor gas fire table for indoor heating. TOXIC carbon monoxide fumes can
accumulate and cause asphyxiation.
• NEVER LEAVE this gas fire table unattended when in using.
• Children should be alerted to the hazards of high surface temperatures and kept at a safe
distance while your fire table is in use.
• Do not store or use gasoline or other flammable vapors and liquids within 25 feet (7.62m) of this
or any other appliance.
• Do not store any combustible materials in the base enclosure.
• The use of alcohol, prescription or non-prescription drugs may impair an individual’s ability to
properly assemble or safely operate this outdoor fire table.
Installation and repair should be done by a qualified service person. The appliance should be
inspected before use and at least annually by a qualified service person. More frequent cleaning
may be required as necessary. It is imperative that the control compartment, burners, and
circulating air passageways of the appliance are kept clean.
4 / 20
IMPORTANT SAFETY INFORMATION
• DO NOT use in an explosive atmosphere. Keep gas fire table area clear and free from
combustible materials, gasoline and other flammable vapors and liquids.
• This outdoor fire table is NOT to be operated by children. Young children should be closely
supervised when in the vicinity of this outdoor fire table.
• This outdoor fire table is not to be installed or used in or on recreation vehicles and/or boats.
Always use in accordance with all applicable local, state and national codes. Contact your local
fire department for details on outdoor burning.
• Use the same precautions you would with any open fire when using this outdoor fire table.
• DO NOT burn solid fuels such as: wood, charcoal briquettes, lump charcoal, manufactured logs,
driftwood, trash, leaves, paper, cardboard, plywood, painted or stained or pressure treated wood
in this outdoor fire table.
• DO NOT use this outdoor fire table until it is COMPLETELY assembled and all parts are
securely fastened and tightened.
• DO NOT store another LP gas tank within 10 feet (3.05 m) of this outdoor fire table while it is in
operation.
• DO NOT use this outdoor fire table near automobiles, trucks, vans or recreational vehicles.
• DO NOT use this outdoor fire table under any overhead structure or near any unprotected
combustible constructions. Avoid using near or under overhanging trees and shrubs.
Always use this outdoor fire table on a hard, level non-combustible surface such a concrete, rock
or stone. An asphalt or blacktop surface may not be acceptable for this purpose.
• DO NOT use this outdoor fire table if any part has been under water. Immediately call a qualified
service technician to inspect the fire table and to replace any part or control system and any gas
control which has been under water.
• DO NOT wear flammable or loose clothing when operating this outdoor fire table.
• DO NOT use in windy conditions.
• Keep all electrical cords away from a hot outdoor fire table.
• Certain areas of this outdoor fire table when in use will become too hot to touch. Do not touch
hot surfaces until the unit has cooled unless you are wearing protective gear such as insulated pot
holders or heat resistant gloves or mittens to avoid burns.
• DO NOT hang or place clothing or other flammable materials on or near the gas fire table.
Any guard or other protective device removed for servicing the fire table must be replaced prior
to operating the fire table.
• DO NOT attempt to move or store this outdoor fire table until all parts are cool.
• DO NOT lean over this outdoor fire table when lighting or when in using.
• Use only the regulator and hose assembly provided. The replacement regulator and hose
assembly shall be that specified by the manufacturer.
• DO NOT attempt to disconnect the gas regulator from the tank or any gas fitting while the
outdoor fire table is in using.
Always shout off gas supply at the tank valve and disconnect regulator from the tank when the
fire table is not in using
• DO NOT sit on the mantle when the unit is in operation.
• DO NOT throw anything onto the fire when the unit is in operation.
• Lava rocks are very hot; please keep the children or pets away at a safe distance.
• It is essential to keep the outdoor fire table valve compartment, burners, and circulating air
passages clean. Inspect outdoor fire table before each use.
•Prior to each fire table operation, check the hose for evidence of excessive abrasion or wear by
looking through the visual check hole. If the hose is damaged, cracked or cut, it must be replaced
before using the gas fire table. The hose assembly can only be replaced with a hose assembly
specified by the manufacturer.
5 / 20
IMPORTANT SAFETY INFORMATION
• Before each use, remove the lava rocks. Examine the burner and its components. If dirty, clean
with a soft brush and soapy water solution. Examine the area around the burner; any dirt or
foreign material, such as spider webs or nests in this area should be removed. If it is evident that
the burner is damaged, the fire table must not be used. The burner assembly cannot be replaced.
Please contact Elementi at 800-678-7294 for technical support.
• Place the hose out of the pathways where people may trip over it. Do not place the hose
in areas where it may be subjected to accidental damage.
WARNING
!
This outdoor fire table is for use with liquid propane (LP) gas only. The conversion to or attempted
use of natural gas in this outdoor fire table is dangerous and could result in serious personal injury,
or property damage.
ATTENTION: Any alteration of the outdoor fire table that is not specifically directed in the operations
manual will void manufacturer warranty.
PROPANE (LP) DANGERS AND WARNINGS
LP Gas
LP gas is flammable and hazardous if handled improperly. Become aware of the characteristics
before using any LP gas product.
Propane Characteristics
• Flammable, explosive under pressure, heavier than air and settles in pools in low areas.
• In its natural state, propane has no odor. For your safety, an odorant has been added.
• Contact with propane could burn your skin.
• Propane is extremely flammable and hazardous if handled improperly.
LP GAS WARNINGS
• Cylinders must be stored outdoors in a well-ventilated area out of reach of children.
• Disconnected cylinders must have threaded valve plugs tightly installed and must not be stored
in a building, garage or any other enclosed area.
• Never use a propane cylinder with a damaged body, valve, collar or footing.
• Dented or rusted propane cylinders may be hazardous and should be checked by your propane
gas supplier.
• Be sure to use only one 20 lb (9.1 kg) LP gas cylinder with a Type 1 valve with this appliance as
required by the American National Standards Institute (ANSI) and the Canadian Standards
steering Committee. Only tanks marked “propane” may be used.
• The LP gas supply tank must be constructed and marked in accordance with the specifications
for LP gas LP gas tanks of the U.S. Department of Transportation (DOT) or the National Standard
of Canada, CAN/CSA-B339, LP gas tanks, Spheres and Tubes for the Transportation of
Dangerous Goods and Commission.
• LP gas tank must be arranged forvapor withdrawal.
6 / 20
PROPANE (LP) DANGERS AND WARNINGS
• The LP gas tank must have a tank collar to protect the tank valve.
• LP gas cylinder must contain a shut-o valve as specified in the Standard for Compressed Gas
Cylinder Valve Outlet and Inlet Connection, ANSI/CGA-V-1-1977, CSA B96.
• The LP gas tank should not be dropped or handled roughly.
• Tanks must be stored outdoors out of the reach of children. Do NOT store in a building, garage,
or any other enclosed area.
• Never store your LP gas tank where temperatures can reachover 125°F.
• Do not store the LP gas cylinder in direct sunlight or near a source of heat or combustion.
• Never keep a filled LP gas tank in a hot car or car trunk. Heat will cause the gas pressure
to increase, which may open the relief valve and allow gas toescape.
• Place dust cap on valve outlet whenever the LP gas tank is not in use. Only install the type of
dust cap on the LP gas tank valve outlet that is provided with the LP gas tank valve. Other types
of caps or plugs may result in leakage of propane.
a. Do not store a spare LP gas cylinder under or near this appliance.
b. Never fill the LP gas cylinder beyond 80% full.
c. If the information in (a) and (b) is not followed exactly, a fire causing death or serious
injury may occur.
• LP gas cylinders should be filled only by a certified LP gas dealer.
• The pressure regulator is set for 11 inches of water column (pressure).
• The maximum inlet gas pressure for this outdoor fire table is 14 inches of water column
pressure.
• Never attempt to attach this appliance to the self-contained LP gas system of a camper trailer,
motor home or house.
Always use the pressure regulator and hose assembly provided with the appliance to connect to
a LP gas cylinder. Never connect to an unregulated LP gas supply. For technical support contact
Elementi at 800-678-7294
• Hand turn the manual gas control valve. Never use tools. If the valve will not turn by hand, do
not try to repair it. Call a Certified Gas Technician. The use of force or any self attempted repair
may result in a fire or explosion.
Connecting your gas cylinder
Before connection, be sure that there is no debris caught in the head of the gas cylinder, head of
the regulator valve or in the head of the burner and burner ports. Connect regulator valve and
hand-tighten firmly. Disconnect the propane cylinder from the regulator valve when the fire table
is not in use. DO NOT obstruct the flow of combustion air and ventilation air to the burner.
7 / 20
HOSE & REGULATOR ASSEMBLY AND REPLACEMENT
1. This fireplace comes equipped with a standard LP gas hose and regulator including the appliance
side connection for a CGA No 791 Cylinder Connection Device. The LP gas hose and regulator
supplied with this fire table must be used. Only a hose and regulator specified by manufacturer can
be used for replacement.
a. The CGA No 791 connection incorporates a magnetic flow limiting device that acts to limit the flow
of gas if a leak is detected between the regulator and the burner valve.
b. If the burner valve is open prior to the LP gas cylinder service valve being opened, the connection
will interpret this free flow of gas to be a leak.
c. The connection safety feature will reduce gas flow from the regulator to the appliance to a minimal
level.
d. Be sure that the burner control valve is closed prior to opening the LP gas cylinder service valve to
ensure that the connection flow limiting device is not triggered mistakenly.
e. If the connection flow limiting device is triggered mistakenly, close the LP gas cylinder service
valve and the burner valve, wait 10 seconds to allow the device to reset, open the cylinder service
valve, then open the burner valve and light the fireplace as per lighting instructions.
2. Be sure to protect the hose from any hot surfaces. Serious danger may result if the hose contacts
any hot surface
3. Regular maintenance of the hose and regulator:
a. Inspect the hose before each use of the fire table. If the hose shows signs of cracks, abrasions,
cuts or damage of any kind, do not operate the appliance. Fix or replace the hose as required before
using the appliance. For assistance with repair or replacement of the hose, call Elementi at
800-678-7294 . Use only replacement parts from the manufacturer.
b. Inspect the seal inside the CGA No 791 service valve on the LP gas cylinder when replacing the
cylinder or at least once per year. If there is any indication of damage, have the seal replaced by a
certified gas dealer before operating the appliance.
4. Do not use tools to tighten the CGA No 791 connection nut onto the LP gas cylinder service valve.
Hand tighten only.
5. Be careful to not cross the threads on the connection when tightening the CGA No 791 connection
on to the LP gas cylinder service valve.
6. “Leak Test” should always be performed after attaching the connection to the LP gas cylinder
service valve. (See “Checking for Leaks” section of this manual on page 12)
7. For the connection of the hose and regulator to the LP tank, refer to the “Connection” section of
the LP gas cylinder section above.
8 / 20
PARTS LIST
1 Fire Table 1
2 LP Regulator and Hose 1
3 Lava Rock 1
4 Battery 1
4
3
1
2
9 / 20
ASSEMBLY INSTRUCTIONS
1
Install the AAA battery as shown in the diagram below. Battery not included.
10 / 20
ASSEMBLY INSTRUCTIONS
2
1. Place the tank seat on the ground and place a 20 lb. propane tank
into the tank seat.
2. Tighten down the screw on the side of the tank seat to secure the
propane tank.
1
2
3
Connecting the LP Gas Tank
Check to make sure there is no debris in the
head of the LP gas tank or in the head of the
regulator valve. Make sure you check the burner
and burner ports as well.
Connect gas line to tank by turning knob
clockwise. Hand tighten only.
Disconnecting the LP Gas Tank
Make sure the valve on the LP gas tank is
OFF.
Disconnect by turning the knob counter
clockwise until it is detached from the valve.
A statement indicating that other cylinders may be acceptable for use with the appliance provided they
are compatible with the appliance retention means and accompanied by illustration(s) depicting the
cylinder mounted to the appliance utilizing the cylinder retention means and the point of contact
between the cylinder and the retention means.
Provided with a listed overfilling prevention device; and provided with a cylinder connection device
compatible with the connection for the appliance.
60"
ASSEMBLY INSTRUCTIONS
4
Place lava rock by hand. DO NOT dump bag out in to the tray to avoid clogging the
burner with dust. Position the lava rock13.2 lbs / 6 kgs) to a level about 1” above
the top of the burner. Make sure that you do not block the igniter box with lava rock
to ensure proper ignition.
11 / 20
FIREPIT
FIREPIT
Adjustable feet has pre-installed on the bottom of fire pit already. Please adjust the hight of
feet to make sure all fire pit was on level always, or increase the height of fire table as your
preference. Please make sure the height was safty before you complete.
12 / 20
PRE-USE INSTRUCTIONS
Orifice is located
in this connection
WARNING
!
Failure to inspect this connection or follow
these instructions could cause a fire or an explosion, which can
cause death, serious bodily injury, or damage to property
Please refer to diagram for proper installation.
If the burner pipe does not rest flush to the orifice please
contact Elementi at 800-678-7294 for assistance.
CHECKING FOR LEAKS
Make a leak check solution by mixing 1 part dish
washing soap with 3 parts water in a spray bottle.
Make sure control knob is “OFF.” Then, turn LP gas
tank to “ON” at valve.
Spray leak solution on valve connections paying
particular attention to the areas indicated by arrows.
If any bubbles appear turn LP gas tank OFF, reconnect
and re-test. If you continue to see bubbles after several
attempts, disconnect LP gas source and contact
Elementi at 800-678-7294 for assistance.
If no bubbles appear after one minute turn tank OFF,
wipe away solution and proceed.
Check for leaks at these locations
WARNING
!
Before using this outdoor fire table, make sure
you have read, understand and are following all information provided in the
Important Safety Information section of this manual. Failure to follow those
instructions can cause death, serious injury or property damage.
Prior to each gas fireplace operation, check the hose and valve for evidence
of excessive abrasion or wear though the visual check hole on the side of the
base. Replace visual check cap prior to operating fireplace.
BURNER CONNECTIONS
Make sure the regulator valve and hose connections are securely fastened
to the burner and the tank. If your unit was assembled for you, visually check
the connection between the burner pipe and orifice. Make sure the burner
pipe fits over the orifice.
Expanded View
LIGHTING INSTRUCTIONS
Using the Ignitor
1. Read instructions before lighting.
2. Control knob must be in the “OFF”position.
3. Connect propane cylinder (See Manual).
4. Push and turn control knob counter clockwise to “Low”.
5. Press the igniter button repeatedly to light burner.
6. Release control knob after 45 seconds.
7. If ignition does not occur in 45 seconds, push and turn burner control
knob to “OFF”wait 5 minutes fan with newspaper or magazine, and
repeat lighting procedure.
8. If igniter does not light burneruse a long match or long butane lighter.
9. Adjust flame to desired flame with the control knob.
Using a Long Match or Lighter
1. Prior to lighting, use a shovel to move lava rocks for
access to the burner.
2. Wearing heat resistant gloves, position the burning
long match or burning butane lighter near the side of
the burner. DO NOT lean over the fire table while
lighting!
3. Turn control knob counterclockwise to “LIGHT”.
4. Remove long match/long butane lighter.
5. After lighting, use a shovel and heat resistant gloves
to carefully move the lava rocks back into their proper
position and replace the glass panel.
6. After lighting, rotate the burner control knob counter
clockwise to “Low” setting. Observe flame, make sure
all burner ports are lit. Flame height should be no
higher than 13 inches tall.
7. Adjust the flame to the desired height with the control
knob.
WARNING
!
If burner fame goes out during operation, immediately urn
the control knob “OFF” and let the gas clear a minimum of
5 minutes before attempting to re-light the fire table.
Please refer to the trouble shooting pages for additional support,
beginning on page 17.
WARNING
!
When using this method to light your
fire table use heat resistant gloves and
follow the step by step instructions.
Failure to do so could result in severe
injury.
18-20”
Normal Flame
Keep the lava rock covered and make sure it is dry before igniting.
!
13 / 20
14 / 20
CARE AND CLEANING
Inspecting
This outdoor fire table must be inspected regularly to insure that the product is safe to use and to
extend product life.
WARNING
!
1. Check the burner to make sure it is securely in place.
2. Check the air mixer to make sure it is clear and free
of insects, spider nests and other debris(see picture).
3. Check all gas connections for leaks.
4. Check ignition system to insure proper sparking.
5. Check components for any signs of damage, rust or
excessive wear.
6. If damage to any component is detected, DO NOT
operate until the proper repairs have been made.
WARNING
!
DO NOT tamper with this appliance. This is DANGEROUS and will void the
warranty. Any part found to be faulty must be replaced with an approved part,
confirmed by manufacturer. For technical support contact Ocean Rock USA at
800-678-7294.
DO NOT inspect this outdoor fireplace until the fire is
COMPLETELY out.
Air mixer
General Care and Cleaning
This outdoor fireplace should be cleaned regularly to ensure safe use and extend product life.
Note: After repeated use, a slight discoloration of the finishes may occur.
Table
1. Wipe exterior surfaces with a mild dish washing soap or baking soda, then rinse clean with water.
Stainless Steel
1. For general cleaning use warm water, soap, ammonia, or detergent apply with a soft cloth or Sponge
2. For finger prints or smears use 3M Stainless Steel Cleaner and Polish, Arcal 20, Lac-O-Nu, LuminWash,
O’Cedar Cream Polish, or Stainless Shine, this will provide a barrier file to minimize fingerprints.
3. For stubborn stains and discoloration use 3M Stainless Steel Cleaner and Polish, Allchem Concentrated
Cleaner, Samae, Twinkle, Cameo Copper Cleaner, Liquid Nu Steel, Coppers or Revere Stainless Steel
Cleaner, apply using a soft cloth in the same direction of the polish lines.
4. While using in salt air environments we recommend cleaning all stainless steel surfaces at least every two
weeks to keep the item in prime condition. Stainless steel is corrosion-resistant but it is not impervious to rust.
Exposure to salt air and sea spray will cause surface rust if you do not care for your products properly.
The best thing you can do to protect the stainless steel is to clean it frequently.
* Use of proprietary names is intended only to indicate a type of cleaner and does not constitute endorsement. Omission
of any proprietary cleanser does not imply its inadequacy. All products should be used in strict accordance with
instructions on package.
Storage
WARNING
!
DO NOT move or store this fire table unless the fire is COMPLETELY out and
cool to the touch.
1. Turn gas OFF at tank connection. Remove tank and store in a cool, dry location outdoors, away from
children.
2. Carefully remove rock filler and store components flat to protect them from breakage.
3. ALWAYS cover your outdoor fire table when not in use with the cover provided with the unit.
4. Store in a cool, dry location away from children and pets.
15 / 20
GAS COMPONENT CONNECTION CHECKS
If the burner will not light or stay lit, please perform the following checks.
1. Make sure the electrode wire is correctly connected. Both electrode wires must be fully inserted
into the igniter box.
2. Make sure that the pilot housing is unobstructed.
Clear any debris on top of the pilot housing and make sure there is no debris between the igniter
pin, thermocouple and the burner tube.
CORRECT
INCORRECT
Igniter Box
Thermocouple
Wire
Igniter Box
Valve
the inner
side
GAS COMPONENT CONNECTION CHECKS
Thermocouple
Igniter Pin
3. Make sure that the igniter pin and thermocouple are correctly positioned.
- The igniter pin should be pointed straight to the thermocouple.
- The thermocouple should be positioned 5mm / 0.196away from the burner tube.
16 / 20
Thermocouple Wire
Valve
Wire should
be in line
with valve
Valve
Igniter Box
4. Make sure that the thermocouple wire is correctly positioned. The thermocouple
wire should be in line with the valve.
Thermocouple
Wire
5mm /
0.196”
TROUBLESHOOTING
17 / 20
Problem: Burner will not light using igniter
Possible Cause 1: Electrode and burners are wet.
-Wipe dry with cloth.
Possible Cause 2: Igniter battery is dead or backwards.
-Check that the AAA battery is inserted correctly in the igniter (see page 9) or replace the battery.
Possible Cause 3: Igniter Pin cracked or broken - sparks at crack.
-Call ELEMENTI at 800-678-7294 for technical support.
Possible Cause 4: Wire loose or disconnected.
-Reference page 16, step 1, reconnect wire. Call Elementi at 800-678-7294.
Possible Cause 5: Wire is shorting (sparking) between igniter and electrode.
-Call ELEMENTI at 800-678-7294 for support.
Possible Cause 6: Igniter Pin not pointing at thermocouple.
-Reference page 16, turn electrode to point at the thermocouple.
Possible Cause 7: Bad Igniter.
-Call ELEMENTI at 800-678-7294 for supporting.
burner
Burner Ports
thermocon
Igniter Pin
Problem: Burner will not light with match
Possible Cause 1: No Gas Flow.
-Check if the LP gas tank is empty. If empty, replace and refill. If the propane tank is not empty,
refer to “Problem: Sudden drop in gas flow” on the following page.
Possible Cause 2: Coupling nut and regulator not fully connected.
-Turn the coupling nut about one half to three fourths a turn, until you feel a solid stop. Do not
use tools, tighten by hand only.
Possible Cause 3: Obstruction of gas flow.
- Check for bent or kinked hose.
Possible Cause 4: Spider webs or insect nest in the Air mixer.
- Clean the Air mixer.
Possible Cause 5: Burner ports clogged or blocked.
-Reference “Problem: Irregular flame pattern” on the following
page. Clean the burner ports as described there.
Problem: The Fire Table emits a lot of black smoke when in use
Possible Cause 1: Hose from gas fireplace is pinched.
-Make sure the hose is not pinched between the fire table and
the source of the gas.
Possible Cause 2: Flame is being obstructed at burner ports.
-Make sure that the gas ports on the burner are free of any lava
rocks so that the flame can flow naturally.
Burner Ports
5mm /
0.196”
5mm /
0.196”
Orifice is located
in this connection
TROUBLESHOOTING
18 / 20
Problem: Sudden drop in gas flow, or a reduced flame height
Possible Cause 1: Out of gas.
-Refill your LP tank.
Possible Cause 2: Excess flow safety device may have been activated.
-Turn control knob to “OFF”, wait 30 seconds and light outdoor fireplace. If flames are still too low
reset the excessive flow safety device by turning off the control knob and LP gas tank valve.
Disconnect regulator. Turn burner control knob to “HIGH”. Wait 1 minute. Turn burner control knob off .
Reconnect regulator and perform a leak check at tank connection. Turn LP gas tank valve on slowly,
wait 30 seconds and then light outdoor fire table.
Problem: Irregular flame pattern,flame does not run the full length of the burner
Possible Cause: Burner ports are clogged or blocked.
-Clean burner ports. Do this by inserting a paperclip into each of the burner ports to ensure they are
not clogged.
WARNING: Make sure burner is not on and the gas supply has been properly disconnected. Allow
15 minutes for unit to cool before touching it.
Problem: Flame blow out
Possible Cause 1: High or gusting winds.
-Increase flame to “HIGH” setting.
Possible Cause 2: Low on LP gas.
-Replace or refill LP gas tank.
Possible Cause 3: Excess fl ow valve tripped.
-Refer to “Problem: Sudden drop in gas flow”.
Problem: Flame seems to lose heat when burning in cold weather- temperature
below 50°F
Possible Cause 1: Ice has built up on the outside of the LP gas tank because the vaporization
process is too low.
-Turn the control knob and the LP gas tank to “OFF”. Replace with a spare LP gas tank and resume
burning. Store the spare LP gas tank in a well ventilated area, away from children
5mm /
0.196”
Burner Ports
Warranty
Ocean Rock USA LLC doing business as Elementi, warrants Elementi fire features and
accessories to be free from defects in parts and workmanship under normal use and service for
a period of 1 year from the date of purchase. In the event of such defects Elementi will, at its
option, repair or replace the defective product. The foregoing is at the discretion of Elementi.
There will be no charge for the replacement parts or product, however it will be the consumer’s
responsibility to return the product to the original place of purchase.
Elementi will not be responsible for consequential damages in excess of the purchase price of
the product on which such liability is based and the warranty does not cover costs including
freight, removal and reinstallation.
This warranty is non-transferable and applies only for units that are for non-commercial personal
use only.
Under this warranty agreement, all gas lines must be installed by a licensed gas fitter.
Damage caused by shipping, staining and abuse are not covered under this warranty. Dings,
dents and scratches, fading and natural weathering are not covered under this warranty.
Decorative rock is not covered under this warranty. Improper installations, repair or
modifications made by anyone other than Elementi will void this warranty and any damage
caused by such is also not covered under this warranty.
Minor chipping, weather fading, water staining and non-structural hairline cracks are typical of
the material of this product and are not covered under this warranty. Some color and texture
variation is typical of the material and finish for this product and is not covered under this
warranty.
Cast concrete is a hand finished process. As such, this product’s finish will vary by unit. There
will be a color variance of up to 15% in each unit. There may also be uneven texture or pattern
as well as small holes in the surface caused by air or water trapped on the surface during
casting. This is a normal trait of cast concrete and is not covered under warranty.
19 / 20
Ocean Rock USA LLC
1300 W. 9th St., Upland, CA 91786
www.elementifire.com
Tel: 800-678-7294
ELEMENTI
THE ART OF FIRE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Elementi OFG145RWLP User guide

Category
Fireplaces
Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI