LEGEND / LÉGENDE / REFERENCIAS / LEGENDA
Tighten Fastener
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Phillips Screwdriver
Destornillador Phillips
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
By Hand
A mano
Von Hand
Com a mão
A mano
Met de hand
À la main
Target of Projector
Punto de enfoque del proyector
Ziel des Projektors
Mira do projector
Punto di proiezione
Doel van de projector
Cible du projecteur
Hammer
Martillo
Hammer
Martelo
Martello
Hamer
Marteau
Pencil Mark
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Potloodmerkteken
Marquage au crayon
Drill Hole
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Percez un trou
Adjust
Ajustar
Einstellen
Ajustar
Regolare
Afstellen
Ajuster
Optional
Opcional
Optional
Opcional
Opzionale
Optie
En option
Security Wrench
Llave de seguridad
Sicherheitsschlüssel
Chave de segurança
Chiave di sicurezza
Veiligheidssleutel
Clé de sécurité
Installation Instructions ELPMBP06
3
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively “Milestone”), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness, or sufficiency of
the information contained in this document.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all components are
properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components attached to the ELPMBP06 does not exceed
50 lbs (22 kg).
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Do not use this product outdoors.
IMPORTANT ! : The ELPMBP06 may either replace an
existing suspended ceiling tile, or it may be installed on top of
an existing suspended ceiling tile.
IMPORTANT ! : The ELPMBP06 has been designed to
support a single electrical receptacle, a double electrical
receptacle, or both.
NOTE: It is the installer’s responsibility to ensure that the
enclosure is bonded to the ground in the switch box, in
accordance with the National Electric Code, ANSI/
NFPA 70 or Canadian Electrical Code, CSA C22.1.
NOTE: ELPMBP06 may be used with ELPMBC02 /
ELPMBC03 / ELPMBC04 columns, ELPMBP07 ceiling
plate, and ELPMBPRH projector mount.
--SAVE THESE INSTRUCTIONS--
INSTALLATION INSTRUCTIONS
ELPMBP06 Installation Instructions
4
DIMENSIONS
DIMENSIONS: INCHES
[MILLIMETERS]
Installation Instructions ELPMBP06
5
TOOLS REQUIRED FOR INSTALLATION
PARTS
5/32"
#2
1/4"
A (1)
[ELPMBP06 assembly]
B (4)
[Clamp bracket]
C (4)
1/16" x 25ft
[Cable]
(security)
[Ceiling tile cutter]
[Wire anchor]
[Screw eye]
[Cable lock]
[1-1/2" NPT Ring]
M (1)
5/32"
L (1)
K (1)
[Locking collar]
J (1)
10-24 x 1/4"
H (1)
10-24 x 1/4"
G (4)
10-24 x 5/8"
N(1)
D (4)
1/4" x 2"
E (4)
0.262" x 1-5/16"
F (4)
ELPMBP06 Installation Instructions
6
PREPARATION
NOTE: The ELPMBP06 may either replace an existing
suspended ceiling tile, or it may be installed on top of
an existing suspended ceiling tile. Procedural
differences are called out as applicable.
1. Determine exact location of extension column (not included)
on suspended ceiling. Ensure column centerline falls within
8-1/2" radius of tile center point. (See Figure 1)
Be sure to consider the following items when determining
column location (See Figure 2):
Dimensional offset of display/projector relative to
column (due to mount and/or interface).
For Projectors: Any recommended dimensions of
projector relative to target (See installation instructions
included with the projector).
Figure 1
Figure 2
2. Mark location of column determined in Step 1 with pencil
(See Figure 1):
A. REPLACEMENT OF EXISTING TILE:
Mark location on ceiling tile framework (4 places).
B. INSTALLATION ON TOP OF EXISTING TILE:
Mark location on lower (finished) side of ceiling tile
(1 place).
3. Remove affected ceiling tile and any adjacent tiles required
for access.
4. If you are replacing an existing tile, proceed to Step 7.
Otherwise, continue below.
5. Press center tip of ceiling tile cutter (M) into finished side of
ceiling tile at marked location. Cut extension column hole
through tile using back and forth hand twisting motion.
6. Reinstall ceiling tile with extension column hole. Ensure tile
is oriented for proper location of hole.
7. Loosen seven clamp screws in lower (finished) side of
ELPMBP06 assembly (A). (See Figure 3)
Figure 3
8. Insert ELPMBP06 assembly (A) into suspended ceiling:
A. REPLACEMENT OF EXISTING TILE:
Lay directly on suspended ceiling framework.
B. INSTALLATION ON TOP OF EXISTING TILE:
Lay on top of suspended ceiling tile.
8-1/2"
(216mm)
1
2A
2B
7
x 7
10
Installation Instructions ELPMBP06
7
9. Rotate large and small circular plates to position extension
column support to the following location (See Figure 4):
A. REPLACEMENT OF EXISTING TILE:
Position according to marked framework.
B. INSTALLATION ON TOP OF EXISTING TILE:
Position over ceiling tile hole.
Figure 4
10. Tighten clamp screws (loosened in Step 7).
11. OPTIONAL STEP FOR INSTALLATION ON TOP OF
EXISTING TILE:
Mark location of electrical cutout on ceiling tile with pencil.
(See Figure 4)
12. Examine ceiling structure (concrete, steel truss, or wood)
above ELPMBP06 assembly (A) to identify four support
cable anchor locations. Each location should be
approximately 15° outboard of support holes in tray (A).
(See Figure 5) Mark locations with pencil.
Figure 5
13. Remove ELPMBP06 assembly (A) and ceiling tile (if
installed).
14. OPTIONAL STEP FOR INSTALLATION ON TOP OF
EXISTING TILE:
Cut electrical box opening in ceiling tile at marked location.
Install UL Listed Raco 560 or equivalent UL Listed electrical
box (not included) to ELPMBP06 (A) following instructions
included with electrical box.
SUPPORT CABLE INSTALLATION
WARNING: Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
Solid Concrete Ceiling Structure
WARNING: Anchors must be installed into structurally
sound solid concrete with a minimum thickness of 1.75"
(44.5mm) or greater. Installation into hollow concrete block,
mortar, or concrete that exhibits cracking, spalling, or other
defects may result in failure of anchor and serious personal
injury or damage to equipment!
1. Drill 1/4" diameter x 1-3/8" deep hole at each marked cable
anchor support location (See Figure 6). Ensure hole is at
least 2-1/2" from nearest concrete edge. Remove debris
from hole.
Figure 6
2. Tap anchor (D) into each hole to a depth of at least 1". (See
Figure 6).
WARNING: Failure to properly set anchor may result in
failure of anchor and serious personal injury or damage to
equipment!
9
11
(A)
12
15°
15°
x 4
x 4
x 4
(A)
1
2
3
4
1/4"
(C)
(D)
ELPMBP06 Installation Instructions
8
3. Using claw portion of hammer, set each anchor (D) by
pulling it out of hole approximately 1/4". (See Figure 6)
4. Insert portion of manufactured loop on cable (C) through
hole in anchor (D) (See Figure 6). Insert end of cable (C)
through loop. Repeat for remaining support locations.
Steel Truss Ceiling Structure
1. Route end of cable (C) over truss at marked cable anchor
support location and then through cable loop. (See Figure 7)
Repeat for remaining support locations.
Figure 7
Wood Ceiling Structure
WARNING: Anchors must be installed into wood with a
minimum thickness of 1-1/2" (38.1 mm) or greater.
1. Drill 5/32" (4.0mm) diameter x 2" (51mm) deep hole at each
marked cable anchor support location. (See Figure 8)
Remove debris from hole.
Figure 8
2. Fully thread eye lag (E) into each hole. (See Figure 8)
3. Route end of cable (C) through eye lag (E) and then through
cable loop. (See Figure 8) Repeat for remaining support
locations.
TRAY INSTALLATION
1. If you are replacing an existing tile, proceed to Step 3.
Otherwise, continue below.
2. Reinstall ceiling tile with extension column hole. Ensure tile
is oriented for proper location of hole.
3. Reinstall ELPMBP06 assembly (A).
4. Install four clamp brackets (B) with four Phillips head
10-24 x 5/8" screws (G). (See Figure 4) Ensure brackets (B)
engage flanges on ELPMBP06 assembly (A) and primary
(1-1/2" (38mm) high) rails of ceiling framework.
Figure 9
CAUTION: Failure to properly tension cables (C) may
result in damage to ceiling tile framework!
5. Thread each cable (C) completely through cable lock (F),
corresponding hole(s) in corner of ELPMBP06 assembly
(A), and completely through opposite side of cable lock (F)
(See Figure 10). Adjust cable tension until ELPMBP06
assembly (A) is supported entirely and evenly by all four
support cables, but not so tight as to distort ceiling tile
framework.
NOTE: Cables (C) can be threaded through either or both
holes in corners of ELPMBP06 assembly (A).
NOTE: Cable lock (F) will allow cable to enter from only one
direction per side, indicated by arrows on lock.
Depress spring loaded pins on cable lock (F) to release
cable tension.
Figure 10
1
(C)
(A)
1.5" (38mm)
4
(G) x4
(B)
5
(C, F) x 4
C
F
A
Installation Instructions ELPMBP06
9
EXTENSION COLUMN INSTALLATION
WARNING:
Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of all
components attached to the ELPMBP06 up to (and including)
the display/projector, does not exceed 50 lbs (22 kg).
1. Install 1-1/2" NPT or NPSM following ANSI/ASME B1.20.1
(Schedule 40, 0.154" minimum thickness aluminum - ASTM
B221) threaded extension column (not included) into
extension collar support until tight, with a minimum of four
threads engaged.
NOTE: If installation instructions are not available, contact
Chief for assistance.
2. Using hex key (L), secure extension column by one of the
following methods (See Figure 3):
Install screw (H) into extension column support,
tightening firmly against column.
OPTIONAL: Install security screw (J) through locking
collar (K) into extension column support, tightening
firmly against column.
NOTE: Locking collar (K) is designed to spin, even when screw
(J) is tight.
Figure 11
3. OPTIONAL FOR INSTALLATION ABOVE EXISTING TILE:
Install NPT ring (N) on extension column below ceiling tile.
(See Figure 12) If necessary, bend four tabs inward to
secure ring to column.
Figure 12
4. Reinstall remaining ceiling tiles as required.
2
(H)
(J, K)
(H)
(J)
(K)
3
(N)
(N)
Manufactured by:
Milestone AV Technologies
A 6436 City West Parkway, Eden Prairie, MN 55344
P 800.582.6480
F 877.894.6918
E [email protected] (Tech Support 7:00am - 7:00pm CST)
www.milestone.com
8800-002777 Rev01
09/15
ELPMBP06 Installation Instructions
Distributed by:
Epson America, Inc.
3840 Kilroy Airport Way
Long Beach, CA 90806
LIMITED WARRANTY
With the exception of electrical products, Milestone warrants its products to be free of defects in material and
workmanship for 10 years. All warranties are in effect beginning the date the product was invoiced by Milestone. Electrical
mechanisms (such as lift products) have a 1-year limited warranty. All warranties are in effect for the original purchaser only.
Milestone disclaims liability for any modifications, improper installation and/or installations over the specified weight capacity.
Milestone also disclaims liability for any modifications made to electrical mechanisms, improper installation, incorrect voltage
connection and/or installations over the stated weight capacity. All Electrical Mechanisms are intended for indoor use only and
failure to comply will void warranty. Milestone’s sole warranty obligation to the owner of its products is to repair or replace (at
Milestone’s discretion) defective products at no charge to the original purchaser within the warranty period. The purchaser is
responsible for returning the product to Milestone via prepaid shipping. To the maximum extent permitted by applicable law,
Milestone disclaims any other warranties, express or implied, including warranties of fitness for a particular purpose and warranties
of merchantability. Milestone will not be liable for any damages whatsoever arising out of the use or inability to use Milestone
products, even if Milestone has been advised of the possibility of such damages. Milestone bears no responsibility for incidental or
consequential damages. This includes, but is not limited to, any labor charges for the repair of Milestone products performed by
someone other than a Milestone employee. Because some states and jurisdictions do not allow the exclusion or limitation of liability
for consequential or incidental damages, the above limitation may not apply. Milestone will not be responsible for damage to
Milestone products caused by misuse, abuse, failure to properly package the product for return to Milestone or for damage caused
by carriers during shipment to or from Milestone. Any repairs to Milestone products required due to misuse, abuse or shipping
damage or repairs of defective Milestone product outside the warranty period will be performed at the current rates established by
Milestone for factory service.
Instructions d'installation
12
DIMENSIONS
AJUSTABLE DANS CE RAYON
,
,
,
,
,
,
,
,
,
,
,
1,5" FILETAGES NPSM
38,1
DIMENSIONS : POUCES
[MILLIMÈTRES]
Instruções de instalação
28
DIMENSÕES
AJUSTÁVEL NESTE RAIO
,
,
,
,
,
,
,
,
,
,
,
1,5" ROSCAS NPSM
38,1
DIMENSÕES: POLEGADAS
[MILÍMETROS]
Installation Instructions
35
Manufactured by:
Milestone AV Technologies
A 6436 City West Parkway, Eden Prairie, MN 55344
P 800.582.6480
F 877.894.6918
E [email protected] (Tech Support 7:00am - 7:00pm CST)
www.milestone.com
8800-002777 Rev01
09/15
Installation Instructions
Distributed by:
Epson America, Inc.
3840 Kilroy Airport Way
Long Beach, CA 90806
LIMITED WARRANTY
With the exception of electrical products, Milestone warrants its products to be free of defects in material and
workmanship for 10 years. All warranties are in effect beginning the date the product was invoiced by Milestone. Electrical
mechanisms (such as lift products) have a 1-year limited warranty. All warranties are in effect for the original purchaser only.
Milestone disclaims liability for any modifications, improper installation and/or installations over the specified weight capacity.
Milestone also disclaims liability for any modifications made to electrical mechanisms, improper installation, incorrect voltage
connection and/or installations over the stated weight capacity. All Electrical Mechanisms are intended for indoor use only and
failure to comply will void warranty. Milestone’s sole warranty obligation to the owner of its products is to repair or replace (at
Milestone’s discretion) defective products at no charge to the original purchaser within the warranty period. The purchaser is
responsible for returning the product to Milestone via prepaid shipping. To the maximum extent permitted by applicable law,
Milestone disclaims any other warranties, express or implied, including warranties of fitness for a particular purpose and warranties
of merchantability. Milestone will not be liable for any damages whatsoever arising out of the use or inability to use Milestone
products, even if Milestone has been advised of the possibility of such damages. Milestone bears no responsibility for incidental or
consequential damages. This includes, but is not limited to, any labor charges for the repair of Milestone products performed by
someone other than a Milestone employee. Because some states and jurisdictions do not allow the exclusion or limitation of liability
for consequential or incidental damages, the above limitation may not apply. Milestone will not be responsible for damage to
Milestone products caused by misuse, abuse, failure to properly package the product for return to Milestone or for damage caused
by carriers during shipment to or from Milestone. Any repairs to Milestone products required due to misuse, abuse or shipping
damage or repairs of defective Milestone product outside the warranty period will be performed at the current rates established by
Milestone for factory service.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Epson ELPMBP06 SpeedConnect Suspended Ceiling Tile Replacement Kit Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI