— Attach the upper portion of the chimney (B1.4.4) on the
metal chimney bracket (A1.4. 4) using the two screws
(G1.4.4).
— Adjust the length of the telescoping chimney by bringing
down the lower part and fitting it into the top of the
hood.
A
B
C
D
E
Chimney bracket
Flue
Adapter
Back-flow valve
Motor outlet
F
Telescoping ventilation shaft
Chimney holding screw
G
Recycling
— Remove the back-flow valve (1.5.1).
— Using the two screws (1.5.2), attach the plastic smoke
deflector against the wall, flush with the ceiling. Be
careful to centre the deflector in relation to the vertical
line drawn on the wall (1.5.2).
— Slide one end of the flue over the deflector and the
other end over the motor outlet (1.5.3).
— Prepare your ventilation shaft, taking care to face the
vents upward so that they are visible (1.5.3).
— Attach the upper portion of the chimney (C1.5.3) on
the metal smoke deflector (A1.5.3) using the two
screws (F1.5.3).
— Adjust the length of the telescoping ventilation shaft
by bringing down the lower part and fitting it into the
top of the hood.
1.5
A
B
C
D
E
Smoke deflector
Telescoping ventilation shaft
Flue
Motor bracket
Vents
Chimney holding screw
F
25
Speed 1
A
B
C
Boost / Automatic mode*
Speed 3
D
E
Speed 2
Light
F
Indicator light
AUTOMATIC MODE (depending on model*)
This type of hood has a smart capability. Fitted with sen-
sors, it switches on automatically when it detects heat
or steam and adjusts the suction speed accordingly.
Once all smoke has been removed, the hood switches
itself off.
Selection of the hob type in automatic mode *
To select your hob type (induction hob by default), the
hood should be switched off.
Press and to enter configuration mode (
flashes).
A short press on to select an induction hob, a
short press on to select a vitro-ceramic hob or a
short press on to select a gas hob.
A short press on (or after 10 sec.) confirms your
choice.
To adjust the sensitivity (By default medium sensitivity):
- a short press on ( flashes) -> minimum sen-
sitivity.
- a short press on ( flashes) -> medium sensi-
tivity.
- a short press on ( flashes) -> maximum sen-
sitivity.
A short press on (or after 10 sec.) confirms your
choice.
Extraction / recycle mode
Configure your hood to suit your installation:
Press and hold and together for 2 seconds
until they light up and flashes or is lit.
A short press on , is lit -> recycle mode.
A short press on , flashes -> extraction
mode.
Confirm the configuration by pressing .
Switching to automatic mode*
Give a long press on , flashes. is lit
until a heat source is detected and the hood starts to
run. At the end of cooking, the hood continues to run
for between 40 seconds and 10 minutes.
A long press on deactivates automatic mode.