Rosemount TankMaster Software Owner's manual

Category
Networking
Type
Owner's manual

Rosemount TankMaster Software:

Rosemount TankMaster Software is an inventory management software package for tank monitoring and configuration of tank gauging equipment. It is a powerful and easy-to-use tool that allows you to configure protocols, devices, and tanks in real-time and provides a clear overview of installed devices and tanks. With Rosemount TankMaster Software, you can:

  • Configure Rosemount Tank Gauging system components, including radar level gauges, temperature transmitters, and pressure transmitters
  • Monitor tank levels, temperatures, and pressures in real-time
  • Set up alarms and notifications for critical events

Rosemount TankMaster Software:

Rosemount TankMaster Software is an inventory management software package for tank monitoring and configuration of tank gauging equipment. It is a powerful and easy-to-use tool that allows you to configure protocols, devices, and tanks in real-time and provides a clear overview of installed devices and tanks. With Rosemount TankMaster Software, you can:

  • Configure Rosemount Tank Gauging system components, including radar level gauges, temperature transmitters, and pressure transmitters
  • Monitor tank levels, temperatures, and pressures in real-time
  • Set up alarms and notifications for critical events
Reference Manual
00809-0400-5110, Rev AB
December 2019
Rosemount
TankMaster
Software installation
i
Reference Manual
00809-0400-5110, Rev AB
Contents
December 2019
Contents
Contents
1Section 1: Introduction
1.1 Manual overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 Technical documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2.1 Reference manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2.2 Product data sheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2Section 2: Installing Rosemount
TankMaster
2.1 Installing the TankMaster software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.1.1 Operating system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.1.2 TankMaster PC Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.1.3 Server PC hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.1.4 Client PC hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2 Installation procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ii
Reference Manual
00809-0400-5110, Rev AB
Contents
December 2019
Contents
iii
Reference Manual
00809-0400-5110, Rev AB
Title Page
December 2019
Title Page
Rosemount
TankMaster
Software
NOTICE
Read this manual before working with the product. For personal and system safety, and for optimum
product performance, make sure you thoroughly understand the contents before installing, using, or
maintaining this product.
For equipment service or support needs, contact your local Emerson Process Management/Rosemount
Tank Gauging representative.
Version
This manual is based on the functionality of TankMaster version 6.F0.
For older TankMaster versions all functionality described in this manual may not be available and the
Graphical User Interface (GUI) may look different.
iv
Reference Manual
00809-0400-5110, Rev AB
Title Page
December 2019
Title Page
1
Reference Manual
00809-0400-5110, Rev AB
Introduction
December 2019
Introduction
Section 1 Introduction
Rosemount
TankMaster
is an Emerson Automation Solutions/Rosemount Tank Gauging inventory
management software package for tank monitoring and configuration of tank gauging equipment. It
provides powerful and easy-to-use tools which allows you to configure protocols, devices, and tanks in
real time.
The graphical interface gives you a clear overview of installed devices and tanks. For each tank you can
see it’s associated transmitters.
The Rosemount Tank Gauging product portfolio includes a wide range of components for small and large
customized tank gauging systems. The system includes various field devices, such as radar level gauges,
temperature transmitters, and pressure transmitters for complete inventory control. The TankMaster
software suite provides you with the tools that you need to configure and operate a Rosemount Tank
Gauging system.
See “Technical documentation” on page 2 for a list of technical documentation.
1.1 Manual overview
The Rosemount TankMaster Software Installation Manual provides system requirements for the
Rosemount TankMaster software and instructions for installing the software package. The manual
includes the following sections:
Section 1: Introduction
A short introduction to Rosemount TankMaster.
Section 2: Installing TankMaster
An guide to system requirements and how to install the TankMaster software package.
2
Reference Manual
00809-0400-5110, Rev AB
Introduction
December 2019
Introduction
1.2 Technical documentation
The Rosemount Tank Gauging System includes a wide portfolio of user documentation. For a complete
list, see the Emerson Automation Solutions web page for Rosemount Tank Gauging System
and
Rosemount Level Measurement
products.
1.2.1 Reference manuals
Rosemount Tank Gauging System Configuration Manual (00809-0300-5100)
Rosemount 2460 System Hub Reference Manual (00809-0100-2460)
Rosemount 2410 Tank Hub Reference Manual (00809-0100-2410)
Rosemount 5900S Radar Level Gauge Reference Manual (00809-0100-5900)
Rosemount 5900C Radar Level Gauge Reference Manual (00809-0100-5901)
Rosemount 5900 Proof Test Manual Supplement (00809-0200-5900)
Rosemount 2240S Temperature Transmitter Reference Manual (00809-0100-2240)
Rosemount 2230 Display Reference Manual (00809-0100-2230)
Rosemount 5300 Series Reference Manual (00809-0100-4530)
Rosemount 5408 Series Reference Manual (00809-0300-4408)
Rosemount TankMaster Software Installation Reference Manual (00809-0400-5110)
Rosemount TankMaster WinView Reference Manual (00809-0300-5110)
Rosemount TankMaster WinOpi Reference Manual (00809-0200-5110)
Rosemount TankMaster WinSetup Reference Manual (00809-0100-5110)
Rosemount Tank Gauging Wireless System Reference Manual (00809-0100-5200)
Rosemount TankMaster Floating Roof Monitoring Reference Manual (00809-0500-5100)
1.2.2 Product data sheets
Rosemount Tank Gauging System Data Sheet (00813-0100-5100)
Rosemount 2460 System Hub Product Data Sheet (00813-0100-2460)
Rosemount 2410 Product Data Sheet (00813-0100-2410)
Rosemount 5900S Product Data Sheet (00813-0100-5900)
Rosemount 5900C Product Data Sheet (00813-0100-5901)
Rosemount 2240S Product Data Sheet (00813-0100-2240)
Rosemount 2230 Product Data Sheet (00813-0100-2230)
Rosemount 5300 Product Data Sheet (00813-0100-4530)
Rosemount 5408 Product Data Sheet (00813-0100-4408)
3
Reference Manual
00809-0400-5110, Rev AB
Introduction
December 2019
Introduction
Figure 1-1. System and User Documentation Structure
Rosemount 2460 System Hub Reference Manual
(Document No. 00809-0100-2460)
Rosemount 2180
Field Bus Modem
Rosemount 2410 Reference Manual
(Document No. 00809-0100-2410)
Rosemount 5900S Reference Manual
(Document No. 00809-0100-5900)
Rosemount 5900C Reference Manual
(Document No. 00809-0100-5901)
Rosemount 2240S Reference Manual
(Document No. 00809-0100-2240)
Rosemount 2230 Reference Manual
(Document No. 00809-0100-2230)
Rosemount Tank Gauging
System Configuration Manual
(Document No. 00809-0300-5100)
Rosemount TankMaster WinSetup Reference Manual
(Document No. 00809-0100-5110)
Rosemount TankMaster WinOpi Reference Manual
(Document No. 00809-0200-5110)
Rosemount TankMaster Software Installation Manual
(Document No. 00809-0400-5110
4
Reference Manual
00809-0400-5110, Rev AB
Introduction
December 2019
Introduction
5
Reference Manual
00809-0400-5110, Rev AB
Installing the Rosemount
TankMaster
Software
December 2019
Installing the Rosemount
TankMaster
Software
Section 2 Installing the Rosemount
TankMaster
Software
2.1 Hardware requirements
The following minimum system specification is required for TankMaster version 6.F0
(1)
:
Table 2-1. Hardware Requirements
Note
A hardware key is not required to run WinSetup but is required for installing tanks.
1. For previous TankMaster versions other system requirements apply. Please contact Emerson Process Management/Rosemount Tank Gauging for more
information.
General
Product Rosemount TankMaster; WinOpi, WinSetup, WinView
TankMaster PC Hardware
Processor
2.5 GHz, multi core processor
Internal Memory (RAM)
4 GB: (32-bit OS)
8 GB: (64-bit OS)
Hard Disk Drive (HDD) or
Solid State Drive (SSD)
128 GB
TankMaster + SQL Server 2017 Express needs approximately 800 MB
Supported operating systems (up to Microsoft
®
Windows Server 2016) need
approximately 25 GB of available space
Monitor A 22 inch or larger monitor is recommended.
Minimum resolution 1280 x 1024.
USB port Minimum 2 ports.
One port for hardware key.
One port for protocol channel. Each protocol channel requires one port
(1)(2)
.
1. Serial ports RS-232 and RS-485 are also supported.
Hardware license key One license key for each PC with a TankMaster server.
Hardware key is not required for TankMaster network clients.
FBM
(2)
2. Not required for communication via Modbus TCP.
Rosemount 2180 Field Bus Modem Part no: 9240002-635
Network Interface Card (NIC) Network Interface Card required for Modbus TCP protocol channel and/or for
TankMaster Client/Server network.
6
Reference Manual
00809-0400-5110, Rev AB
Installing the Rosemount
TankMaster
Software
December 2019
Installing the Rosemount
TankMaster
Software
2.2 Software requirements
2.2.1 Operating system
English version of:
Windows 10 version 1803, 1809, 1903
(64-bit recommended, required for batch function)
Windows 2012 Server R2
Windows 2016 Server
2.2.2 Networking
TankMaster network clients require a minimum bandwidth of 10 Mbit/s.
All TankMaster server and client PCs in the network must have the same TankMaster version.
7
Reference Manual
00809-0400-5110, Rev AB
Installing the Rosemount
TankMaster
Software
December 2019
Installing the Rosemount
TankMaster
Software
2.3 Installation procedure
To install the TankMaster software package:
1. Insert the TankMaster CD-ROM in the TankMaster PC.
Note
If the installation wizard does not start automatically when the CD-ROM is inserted, double-click the
Tmcd.exe file.
2. In order to read the TankMaster manuals in pdf format you may need to install Acrobat Reader. Click the
Acrobat Reader button and follow the on-screen instructions.
3. To open a reference manual, click the Manuals button, select the desired manual and click the View
button.
.
4. To proceed with the TankMaster installation click the Install button on the splash screen.
5. Follow the on-screen instructions to complete the installation.
6. A restart of the PC will be required to finish the installation.
2.3.1 Ini files
Tankmaster ini-files are required to read holding and input register data from field devices. These devices
are available in WinSetup once installed.
If WinSetup indicates that the ini-files were not successfully installed, and they need to be re-installed, or
updated, they can be installed separately without reinstalling Tankmaster.
Simply repeat step1 of the Installation Procedure and click the Inifiles button.
8
Reference Manual
00809-0400-5110, Rev AB
Installing the Rosemount
TankMaster
Software
December 2019
Installing the Rosemount
TankMaster
Software
2.3.2 Network communication
For a TankMaster client/server network, the DCOM
(1)
and firewall settings need to be configured.
Normally the DCOM configuration is done automatically when TankMaster is installed. DCOM
configuration may also be done by using the program dcomcnfg.exe which is distributed with the
Microsoft
®
Windows operating system.
Please consult Emerson
Automation Solutions for further assistance if needed.
2.3.3 Reports
Reports are created in .pdf format. It is recommended that Adobe Reader version 8.1.2. is installed for
reading the reports. Compatibility with later versions is not guaranteed.
Adobe Reader version 8.1.2 is available on the Rosemount TankMaster installation CD.
1. Distributed Component Object Model is a Microsoft
®
technology for communication between software components on computers in a network.
Global Headquarters and Europe Regional Office
Tank Gauging
Emerson Automation Solutions
Box 150
(Visiting address: Layoutvägen 1)
SE-435 23 Mölnlycke
+46 31 337 00 00
+46 31 25 30 22
North America Regional Office Tank Gauging
Emerson Automation Solutions
6005 Rogerdale Road
Mail Stop NC 136
Houston TX 77072
United States
+1 281 988 4000 or +1 800 722 2865
Latin America Regional Office
Emerson Automation Solutions
1300 Concord Terrace, Suite 400
Sunrise, FL 33323, USA
+1 954 846 5030
+1 954 846 5121
RFQ.RMD-RCC@Emerson.com
Europe Regional Office
Emerson Automation Solutions Europe GmbH
Neuhofstrasse 19a P.O. Box 1046
CH 6340 Baar
Switzerland
+41 (0) 41 768 6111
+41 (0) 41 768 6300
RFQ.RMD-RCC@Emerson.com
Asia Pacific Regional Office
Emerson Automation Solutions
1 Pandan Crescent
Singapore 128461
+65 6777 8211
+65 6777 0947
Middle East and Africa Regional Office
Emerson Automation Solutions
Emerson FZE P.O. Box 17033
Jebel Ali Free Zone - South 2
Dubai, United Arab Emirates
+971 4 8118100
+971 4 8865465
RFQ.RMTMEA@Emerson.com
Linkedin.com/company/Emerson-Automation-Solutions
Twitter.com/Rosemount_News
Facebook.com/Rosemount
Youtube.com/user/RosemountMeasurement
Google.com/+RosemountMeasurement
Standard Terms and Conditions of Sale can be found on the Terms and Conditions of
Sale page.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount
is a mark of one of the Emerson family of companies. All other marks are the property
of their respective owners.
© 2019 Emerson. All rights reserved.
Reference Manual
00809-0400-5110, Rev AB
December 2019
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Rosemount TankMaster Software Owner's manual

Category
Networking
Type
Owner's manual

Rosemount TankMaster Software:

Rosemount TankMaster Software is an inventory management software package for tank monitoring and configuration of tank gauging equipment. It is a powerful and easy-to-use tool that allows you to configure protocols, devices, and tanks in real-time and provides a clear overview of installed devices and tanks. With Rosemount TankMaster Software, you can:

  • Configure Rosemount Tank Gauging system components, including radar level gauges, temperature transmitters, and pressure transmitters
  • Monitor tank levels, temperatures, and pressures in real-time
  • Set up alarms and notifications for critical events

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI