Southbend P24C-CC Datasheet

Category
Cookers
Type
Datasheet

This manual is also suitable for

Job Item#
www.yatesgd.com www.yatesgraphicdesign.com
STANDARD CONSTRUCTION SPECIFICATIONS
24" Sectional Range
Full-Width Charbroiler
Model P24C-CC with optional 24" ue riser
P24N-CC (Modular Mount)
P24C-CC (Cabinet Base)
Standard Features
• 24"-widesectionalrangewithfull-widthcharbroileravailable
withacabinetbaseorasamodularunit(formountingon
countertop,refrigeratedorfreezerbase)
• Four16,000BTUNAT(14,000BTULP)burnerswithtwo
high/lowcontrolknobs
• Removablecastirongrateswithadjustablefront-to-back
slopethatipoverforeither1/8"or1/4"gridwidth
• 600°Fevensurfacetemperatureonhighsetting
• Castironradiantsor“lavarocks”(eldconvertible)
• 9-1/4"deepfrontrail
• Removabledriptray
• Stainlesssteelfront,sides,rearandexteriorbottom
• Fullyinsulatedliningandburnerbox
• 1-1/4"frontgasmanifoldand1"reargasconnection
• 5"highstainlesssteelueriser
• Freebattery-designassistance
• Warranty:twoyearsonspeciedoperationalpartsandone
yearonlaborfromdateofpurchase
Standard Features of Cabinet-Base Model
• Stainlesssteelcabinetwithremovabledoorsthatopenfrom
thecenter
Exterior Finish:Front,sides,rearandexteriorbottom
constructedof#3polished430and304stainlesssteel.
Range: 24"-widefront-manifoldsectionalrangewith
64,000BTUNAT(56,000BTULP)full-widthcharbroilerwith
removablecastirongratesandoperatingsurfacetemperature
ofupto600°F(315°C).
Front Rail: 9-1/4"deepfrontrail.
Flue Riser: 5"highstainlesssteelueriser
Battery: Unitcanbeinanypositioninabattery.Iftheunitis
attheendofthebattery,theendsidewillbesolid(ratherthan
haveacoverplateovertheendofthefrontmanifold).
Legs:6"stainlesssteeladjustablelegsstandard.
Model 24C:Stainlesssteelcabinetbasewithtworemovable
doorsthatopenfromthecenter.
PrintedinUSA
FormP24-CCRev3(September/2009)
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Models:
REAR VIEW
7" (178)
FRONT VIEW
24" (610)
37-1/2"
(953)
24"
(610)
60"
(1524)
41"
(1041)
72"
(1829)
5" Flue Riser
24" Flue Riser
36" Flue Riser
36"
(914)
TOP VIEW
20"
(508)
Optional
Rear Gas
Connection
SIDE VIEW
37-1/2" (953)
34" (864)
40" (1016)
43-1/2" (1105)
10-1/2"
(267)
33-3/4"
(857)
5" (128)
SIDE VIEW of MODULAR MODEL
Front Gas
Manifold
9-1/4"
(235)
8-1/2" (216)
Optional extra-deep flue riser (cooking area is
same as for models with standard flue riser).
P24N-CC P24C-CC
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
OPTIONS and ACCESSORIES
MISCELLANEOUS
UTILITY INFORMATION
GAS:Eachunithasa1-1/4"frontmanifoldthatcouplestothe
adjacentsectionalunit(s),anda1"reargasconnectionwithamale
NPTconnector.Minimumgassupplypressureis7"W.C.fornatural
gasand11"W.C.forpropane.Allsectionalunitsrequirearegulated
gassupply(apressureregulatormustbeorderedseparately).If
usingaexible-hosegasconnection,theinsidediameterofthehose
mustnotbesmallerthantheconnectorontheunitandmustcomply
withANSIZ21.69,providinganadequatemeansofrestraintto
preventunduestrainonthegasconnection.
• Ifcastersareusedwithaexible-hosegasconnection,a
restrainingdeviceshouldbeusedtopreventunduestrain
onthehose.
• Minimumclearancefromnoncombustibleconstructionis
zero.Installationnexttocombustibleconstructionisnot
recommended.
• Installationunderaventedhoodisrecommended.
• Checklocalcodesforreandsanitaryregulations.
NOTICE:
Southbendhasapolicyofcontinuousproductresearchand
improvement.Wereservetherighttochangespecicationsand
productdesignwithoutnotice.Suchrevisionsdonotentitlethebuyer
tocorrespondingchanges,improvements,additionsorreplacements
forpreviouslypurchasedequipment.
Externalpressureregulator
Frontrailoptions:
Cutoutsinfrontrailforsaucepans
7-1/4"deepfrontrail(tomatchold
stylesectional)
Squarebellybarmountedon7-1/4"
deepfrontrail
Casters(fronttwocasterslock)
Cablerestraintkit(torestrict
movementwhenoncasters)
24"or36"highueriser
Open-framebasewithcastersfor
battery
Extra-deeprear-extendingueriser
Removableshelfinsidecabinet
Platedshgrids
FormP24-CCRev3(September/2009)
Dimensionsshownininchesand(millimeters)
Shipping Crate DimenSionS & Weight
moDel WiDth height Depth Volume Weight
P24N-CC
39"
(991)
21"
(533)
44"
(1118)
20.9cuft
(0.59cum)
260lbs
(117.9kg)
P24C-CC
39"
(991)
45"
(1143)
44"
(1118)
44.7cuft
(1.27cum)
400lbs
(181.4kg)
moDel
gaS (Btu/hour)
natural propane
P24N-CC 64,000 56,000
P24C-CC 64,000 56,000
  • Page 1 1
  • Page 2 2

Southbend P24C-CC Datasheet

Category
Cookers
Type
Datasheet
This manual is also suitable for

Ask a question and I''ll find the answer in the document