Maxon BMR-CS Maintenance Manual

Type
Maintenance Manual
M-14-23
REV. A
FEBRUARY 2016
© MAXON Lift Corp. 2016
Maintenance Manual Contains:
• Warranty Information
• Warnings
• Service Time Chart
• Periodic Maintenance Checklist
• Service and Maintenance Instructions
• Decals
• Hydraulic & Electrical System Diagrams
• Troubleshooting
LIFT CORP.
11921 Slauson Ave.
Santa Fe Springs, CA. 90670
CUSTOMER SERVICE:
TELEPHONE (562) 464-0099 TOLL FREE (800) 227-4116
FAX: (888) 771-7713
WARRANTY/ RMA POLICY & PROCEDURE
NOTE: For latest version of all Manuals (and replacements), download the
Manuals from Maxon’s website at www.maxonlift.com.
LIFTGATE WARRANTY
Type of Warranty: Full Parts and Labor
Term of Warranty: Standard Liftgates - 2 years from ship date or 6,000 cycles
Premium Liftgates - 2 years from ship date or 10,000 cycles
This warranty shall not apply unless the product is installed, operated and maintained in accordance with MAXON Lift’s speci cations as set forth in
MAXON Lift’s Installation, Operation and Maintenance manuals. This warranty does not cover normal wear, maintenance or adjustments, damage or
malfunction caused by improper handling, installation, abuse, misuse, negligence, or carelessness of operation. In addition, this warranty does not
cover equipment that has had unauthorized modi cations or alterations made to the product.
MAXON agrees to replace any components which are found to be defective during the rst 2 years of service, and will reimburse for labor based on
MAXON’s Liftgate Warranty Flat Rate Schedule. (Copy of the Flat Rate is available at www.maxonlift.com.)
All warranty repairs must be performed by an authorized MAXON warranty facility. For any repairs that may exceed $500, including parts and labor,
MAXON’s Technical Service Department must be noti ed and an “Authorization Number” obtained.
All claims for warranty must be received within 30 Days of the repair date, and include the following information:
1. Liftgate Model Number and Serial Number
2. The End User must be referenced on the claim
3. Detailed Description of Problem
4. Corrective Action Taken, and Date of Repair
5. Parts used for Repair, Including MAXON Part Number(s)
6. MAXON R.M.A. # and/or Authorization # if applicable (see below)
7. Person contacted at MAXON if applicable
8. Claim must show detailed information i.e. Labor rate and hours of work performed
Warranty claims can also be placed online at www.maxonlift.com. Online claims will be given priority processing.
All claims for warranty will be denied if paperwork has not been received or claim submitted via Maxon website for processing by MAXON’s Warranty
Department within 30 days of repair date.
All components may be subject to return for inspection, prior to the claim being processed. MAXON products may not be returned without prior written
approval from MAXON’s Technical Service Department. Returns must be accompanied by a copy of the original invoice or reference with original
invoice number and are subject to a credit deduction to cover handling charges and any necessary reconditioning costs. Unauthorized returns will be
refused and will become the responsibility of the returnee.
Any goods being returned to MAXON Lift must be pre-approved for return, and have the R.M.A. number written on the outside of the package in plain
view, and returned freight prepaid. All returns are subject to a 15% handling charge if not accompanied by a detailed packing list. Returned parts
are subject to no credit and returned back to the customer. Defective parts requested for return must be returned within 30 days of the claim date for
consideration to:
MAXON Lift Corp.
10321 Greenleaf Ave., Santa Fe Springs, CA 90670
Attn: RMA#__
MAXON’s warranty policy does not include the reimbursement for travel time, towing, vehicle rental, service calls, oil, batteries or loss of income due to
downtime. Fabrication or use of non Maxon parts, which are available from MAXON, are also not covered.
MAXON’s Flat Rate Labor Schedule takes into consideration the time required for diagnosis of a problem.
All Liftgates returned are subject to inspection and a 15% restocking fee. Any returned Liftgates or components that have been installed or not returned
in new condition will be subject to an additional reworking charge, which will be based upon the labor and material cost required to return the Liftgate or
component to new condition.
PURCHASE PART WARRANTY
Term of Warranty: 1 Year from Date of Purchase.
Type of Warranty: Part replacement only. MAXON will guarantee all returned genuine MAXON replacement parts upon receipt and inspection of parts
and original invoice.
All warranty replacements parts will be sent out via ground freight. If a rush shipment is requested, all freight charges will be billed to the requesting
party.
TABLE OF CONTENTS
SUMMARY OF CHANGES: M-14-23, REVISION A ............................................................. 6
WARNINGS ........................................................................................................................... 7
PERIODIC MAINTENANCE .................................................................................................. 9
DECALS - WELDING CAUTION ........................................................................................... 9
DECALS .............................................................................................................................. 10
PREVENTATIVE MAINTENANCE CHECKLIST ................................................................. 12
PERIODIC MAINTENANCE CHECKS ................................................................................ 14
BMR LUBRICATION DIAGRAM .......................................................................................... 15
CHECKING HYDRAULIC FLUID ........................................................................................ 16
CHANGING HYDRAULIC FLUID ........................................................................................ 18
BLEEDING HYDRAULIC SYSTEM ..................................................................................... 19
REPLACING PARTS ..........................................................................................................20
CLOSING CYLINDER REPLACEMENT ............................................................................ 20
LIFTING CYLINDER REPLACEMENT ............................................................................... 22
RUNNER REPLACEMENT ................................................................................................. 26
HYDRAULIC SYSTEM DIAGRAMS ................................................................................... 45
PUMP & MOTOR SOLENOID OPERATION - GRAVITY DOWN ........................................ 45
PUMP & MOTOR SOLENOID OPERATION - POWER DOWN .......................................... 46
GRAVITY DOWN HYDRAULIC SCHEMATIC ..................................................................... 47
GRAVITY DOWN HYDRAULIC LINES IDENTIFICATION .................................................. 48
POWER DOWN HYDRAULIC SCHEMATIC ....................................................................... 50
POWER DOWN HYDRAULIC LINES IDENTIFICATION .................................................... 52
ELECTRICAL SYSTEM DIAGRAMS ................................................................................. 54
INTERCONNECTING ELECTRICAL SCHEMATIC ............................................................. 54
SINGLE PUMP BOX ELECTRICAL SCHEMATIC - GRAVITY DOWN ............................... 55
DUAL PUMP BOX ELECTRICAL SCHEMATIC - GRAVITY DOWN ................................... 56
SINGLE PUMP BOX ELECTRICAL SCHEMATIC - POWER DOWN ................................. 57
DUAL PUMP BOX ELECTRICAL SCHEMATIC - POWER DOWN ..................................... 58
WIRING HARNESS CONNECTOR IDENTIFICATION ....................................................... 59
WIRING HARNESS TWIST-LOCK CONNECTORS ........................................................... 60
TROUBLESHOOTING ........................................................................................................ 61
PLATFORM WILL NOT RAISE & MOTOR WILL NOT RUN ............................................... 61
PLATFORM WILL NOT RAISE & MOTOR RUNS ............................................................... 62
PLATFORM WILL NOT RAISE LOAD AT RATED CAPACITY ............................................ 64
PLATFORM RAISES AND LOWERS UNEVENLY .............................................................. 66
PLATFORM RAISES HALFWAY & STOPS......................................................................... 68
PLATFORM WILL NOT FOLD ............................................................................................. 70
PLATFORM WILL NOT UNFOLD ........................................................................................ 72
POWER OPEN/CLOSE RELIEF VALVE PRESSURE SETTING ....................................... 74
LIFTING LINE RELIEF VALVE PRESSURE SETTING ....................................................... 75
TROUBLESHOOTING - GRAVITY DOWN ......................................................................... 76
PLATFORM WILL NOT LOWER ......................................................................................... 76
PLATFORM LOWERS SLOWLY ......................................................................................... 78
TROUBLESHOOTING - POWER DOWN ........................................................................... 80
RELIEF VALVE PRESSURE SETTING .............................................................................. 80
PLATFORM WILL NOT LOWER ......................................................................................... 82
PLATFORM LOWERS SLOWLY ........................................................................................ 84
PAGE DESCRIPTION OF CHANGE
COVER Updated REV and date.
49,53
Added hose information for 28 foot extension. Added NOTE about hose with yellow
bands.
55-58 Relay fuse changed to 2 AMP on electrical schematics.
SUMMARY OF CHANGES: M-14-23, REVISION A
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
7
Do not stand, or allow obstructions, under the platform when lowering the Liftgate. Be sure your
feet are clear of the Liftgate.
• Keep ngers, hands, arms, legs, and feet clear of moving Liftgate parts (and platform
edges) when operating the Liftgate.
Disconnect Liftgate power cable from battery before repairing or servicing Liftgate.
Comply with the following WARNINGS and SAFETY INSTRUCTIONS while maintaining
Liftgates. See Operation Manual for operating safety requirements.
If it is necessary to stand on the platform while maintaining the Liftgate, keep your feet and any
objects clear of the inboard edge of the platform. Your feet or objects on the platform can become
trapped between the platform and the Liftgate extension plate.
WARNING
!
• Correctly stow platform when not in use. Extended platforms could create a hazard for
people and vehicles passing by.
Recommended practices for welding on steel parts are contained in the current AWS (American
Welding Society) D1.1 Structural Welding Code - Steel. Damage to Liftgate and/or vehicle, and
personal injury could result from welds that are done incorrectly.
Recommended practices for welding on aluminum parts are contained in the current AWS
(American Welding Society) D1.2 Structural Welding Code - Aluminum. Damage to Liftgate
and/or vehicle, and personal injury could result from welds that are done incorrectly.
WARNINGS
Welding on galvanized parts gives off especially hazardous fumes. Comply with WARNING decal
on the galvanized part (
FIG. 7-1). To minimize hazard remove galvanizing from weld area, provide
adequate ventilation, and wear suitable respirator.
FIG. 7-1
Remove all rings, watches and jewelry before doing any electrical work.
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
8
If an emergency situation arises (vehicle or Liftgate) while operating the Liftgate, release the con-
trol switch to stop the Liftgate.
A correctly installed Liftgate operates smoothly and reasonably quiet. The only noticeable noise
during operation comes from the power unit while the platform is raised. Listen for scraping, grat-
ing and binding noises and correct the problem before continuing to operate Liftgate.
Use only Maxon Authorized Parts for replacement parts. Provide Liftgate model and serial num-
ber information with your parts order. Order replacement parts from:
MAXON LIFT CORP. Customer Service
11921 Slauson Ave., Santa Fe Springs, CA 90670
Online: www.maxonlift.com
Express Parts Ordering: Phone (800) 227-4116 ext. 4345
Email: Ask your Customer Service representative
Keep decals clean and legible. If decals are illegible or missing, replace them. Free replacement
decals are available from Maxon Customer Service.
Consider the safety and location of bystanders and location of nearby objects when operating the
Liftgate. Stand to one side of the platform while operating the Liftgate.
Wear appropriate safety equipment such as protective eyeglasses, faceshield and clothing while
performing maintenance on the Liftgate and handling the battery. Debris from drilling and contact
with battery acid may injure unprotected eyes and skin.
Do not allow untrained persons or children to operate the Liftgate.
Be careful working by an automotive type battery. Make sure the work area is well ventilated and
there are no ames or sparks near the battery. Never lay objects on the battery that can short the
terminals together. If battery acid gets in your eyes, immediately seek rst aid. If acid gets on your
skin, immediately wash it off with soap and water.
Read and understand the instructions in this Maintenance Manual before performing mainte-
nance on the Liftgate.
Before operating the Liftgate, read and understand the operating instructions in Operation
Manual.
Comply with all WARNING and instruction decals attached to the Liftgate.
SAFETY INSTRUCTIONS
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
9
Comply with welding CAUTION decals on Lift-
gate runners.
CAUTION
NOTE: See following pages to nd the other decals on
Liftgate.
PERIODIC MAINTENANCE
FIG. 9-1
DECALS - WELDING CAUTION
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
10
PERIODIC MAINTENANCE
FIG. 10-1
NOTE: Ensure there is no residue, dirt, or corrosion where decals are attached. If
necessary, clean surface before attaching decals.
FAMILY OWNED DECAL
(2 PLACES)
P/N 283445-01
SERIAL PLATE
FAMILY OWNED
DECAL
P/N 283445-01
DECAL “C”
DECAL “A”
DECAL “F”
DECAL “B”
YELLOW
ALIGNMENT TAPE
P/N 090175-14
DECAL “D”
CAUTION DECAL
(2 PLACES)
P/N 260552
WARNING DECAL
P/N 288966-01
NOTE: Preferred decal layout is shown. De-
cals on the Liftgate are attached at the
factory. If vehicle does not permit this
layout, decals in the manual and de-
cal kit must be applied so that they are
easily visible when approaching vehi-
cle to operate Liftgate. Use good com-
mon sense when locating these decals
on vehicle.
STOW WARNING
DECAL
P/N 282847-01
DECALS
DECAL “E”
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
11
DECAL SHEET
FIG. 11-1
MODEL ORDER P/N DECAL “C”
BMRB-CS35 289163-01 3500 LBS. [1600 KG]
BMRB-CS44 289163-02 4400 LBS. [2000 KG]
DECAL SHEET PART NUMBERS
TABLE 11-1
(REFER TO TABLE 11-1)
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
12
MAXON BMR-CS LIFTGATE
PREVENTATIVE MAINTENANCE CHECKLIST
PERIODIC MAINTENANCE
PM Interval: Quarterly / Annual
Date: / /
Equipment: W/O # Location:
Mechanic: Serial # Model #
Check Appropriate Box. “”
MAXON Quarterly Liftgate PM Procedures
Satisfactory Repair Required Corrected
1
Check your company’s maintenance records to verify when quarterly and
annual PM’s are due.
Satisfactory Repair Required Corrected
2
Check for oil leaks: cylinders, ttings, hoses, valves, oil lter and ttings
inside of pump box.
Satisfactory Repair Required Corrected
3
Check for damage: bent ramps, platform, columns, runners & hydraulic
tubes.
Satisfactory Repair Required Corrected
4 Check for loose or missing nuts, bolts, covers, roll pins, screws and pins.
Satisfactory Repair Required Corrected
5
Check for cracked welds: columns, runners, platform, chain arms, pump
box and door frame.
Satisfactory Repair Required Corrected
6
Check platform lowering speed: Range is 8-22 seconds with unloaded
platform. Check “D” valves for proper operation.
Satisfactory Repair Required Corrected
7 Check platform pins and couplers. Check roller assemblies.
Satisfactory Repair Required Corrected
8
Check platform raising speed: Range is 9-21 seconds with unloaded
platform.
Satisfactory Repair Required Corrected
9
Check open and close speed: Range is 4-7 seconds in either direction.
Adjust if necessary.
Satisfactory Repair Required Corrected
10 Check platform pins and couplers. Check roller assemblies on runners.
Satisfactory Repair Required Corrected
11
Check switches, circuit breaker & wiring connections on Liftgate as well as
inside pump box. Also check that ground strap connections are tight.
Satisfactory Repair Required Corrected
12 Check gear pump for unusual noise (i.e. squealing or excessive RPM).
Satisfactory Repair Required Corrected
13
Check oil level with platform stowed. Refer to oil decal inside pump cover.
The sight glass should be half full. Check oil for contamination. Change if
needed.
Satisfactory Repair Required Corrected
14 Check batteries: load test, corrosion, cables, hold downs and water level.
Satisfactory Repair Required Corrected
15 Check platform chains for wear each time maintenance is performed.
Satisfactory Repair Required Corrected
16 Check operation of retension ramps.
Satisfactory Repair Required Corrected
17 Check all charging and ground cable connections.
Satisfactory Repair Required Corrected
18
Pump EP synthetic grease in each lube tting at 2 platform pivots and the 2
roller axles on the 4 tandems. Wipe away grease seepage. Ensure each of
the tandem rollers is clean and free of grease.
Satisfactory Repair Required Corrected
19
Follow your company’s guidelines for completing PM stickers and
maintenance records for the Liftgate.
TABLE 12-1
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
13
MAXON Annual Liftgate PM Procedures
Satisfactory Repair Required Corrected
20 Replace spin-on lter in pump box. Change hydraulic uid if contaminated.
Satisfactory Repair Required Corrected
21 Inspect wear on slide pads, on the RH and LH runners.
TABLE 13-1
For more detailed information, please refer to the applicable sections in this Maintenance Manual and
the separate Parts Manual. Use only genuine Maxon replacement parts for all repairs.
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
14
NOTE: Photocopy the PM CHECKLIST on the preceding page to help keep track of peri-
odic maintenance on the Liftgate. Keep completed form with maintenance records.
Annually
Quarterly
PERIODIC MAINTENANCE CHECKS
Never operate the Liftgate if parts are loose or missing.
WARNING
Check the hydraulic uid level in the pump reservoir. Refer to the CHECKING HYDRAULIC
FLUID procedure in the PERIODIC MAINTENANCE section.
Pump EP synthetic grease in tting on 2 platform pivots and roller axels on 4 tandems.
Check for worn out links on each of the two platform chains.
Check each end of the two platform chains to make sure they are fastened properly.
Check that all roll pins are in place and protrude evenly from both sides of hinge pin col-
lar. Replace roll pins if necessary.
Check that all WARNING and instruction decals are in place and legible.
Check electrical wiring for chaf ng and make sure wiring connections are tight and free
of corrosion. MAXON recommends using dielectric grease on all electrical connections.
Check hoses and ttings for chaf ng and uid leaks. Replace if necessary.
Keep track of the grade of hydraulic uid in the pump reservoir. Never mix two different
grades of uid.
If hydraulic uid appears contaminated, refer to the CHANGING HYDRAULIC FLUID
procedure on following page.
Check for rust and oily surfaces on Liftgate. If there is rust or oil on the Liftgate, clean it
off.
Change spin-on oil lter.
Inspect for wear on slide pads on the RH & LH runners.
!
NOTE: When replacing parts, refer to Parts Manual for genuine MAXON replacement parts.
Check pump box cover seal. Replace seal if damaged.
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
15
FIG. 15-1
NOTE: Lube ttings are shown for the tandem roller axles on the LH runner and the pivot
on the LH side of platform. There are also lube ttings in the same location on the
tandem roller axles for the RH runner and the pivot on the RH side of the platform.
Refer to the PERIODIC MAINTENANCE CHECKS and PREVENTATIVE MAIN-
TENANCE CHECKLIST for the recommended grease and maintenance interval.
BMR LUBRICATION DIAGRAM
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
16
CHECKING HYDRAULIC FLUID
1. Stow the platform in the up position. Refer
to Operation Manual for instructions.
NOTE: If the hydraulic uid in the reservoir is contaminated, do the CHANGING
HYDRAULIC FLUID procedure in this section.
CAUTION
Keep dirt, water and other contaminants from entering the hydraulic system.
Before opening the hydraulic uid reservoir ller cap, drain plug and hydraulic
lines, clean up contaminants that can get in the openings. Also, protect the
openings from accidental contamination.
Never mix synthetic uids with conventional hydraulic uids. Hydraulic system
must be purged if the uids are mixed.
2. Open the pump box cover to gain
access to full line and ller cap
(FIG. 16-1).
4. Reinstall ller cap (FIG. 16-1) and close
the pump box cover.
NOTE: Exxon Univis HVI-13 hydraulic uid is recommended for operating tem-
peratures of -40 to +120° F. Refer to decal in pump box. The ISO-15 uids
in TABLE 17-1 may be used if the recommended uids are unavailable. If
necessary, the ISO-32 uids in TABLE 17-2 may be used where ordinary
seasonal temperatures are near +100° F or higher.
3. Check if hydraulic uid level
is at the full line (FIG. 16-1). If
necessary, remove ller cap (FIG.
16-1) and add the correct grade
of hydraulic uid until level rises to
the full line (FIG. 16-1).
CHECKING HYDRAULIC FLUID LEVEL
FIG. 16-1
FILLER
CAP
NOTE: Information for checking
hydraulic uid level is shown
on a decal on the pump
reservoir.
PERIODIC MAINTENANCE
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
17
ISO-32 HYDRAULIC OIL
BRAND PART NUMBER
CHEVRON HIPERSYN 32
KENDALL GOLDEN MV
SHELL TELLUS S2 V32
EXXON UNIVIS N-32
MOBIL
DTE-13M, DTE-24,
HYDRAULIC OIL-13
TABLE 17-1
TABLE 17-2
ISO-15 OR MIL-H-5606 TYPE HYDRAULIC OIL
BRAND PART NUMBER
CHEVRON FLUID A, AW-MV-15
KENDALL GLACIAL BLU
SHELL TELLUS S2 V15
MOBIL DTE-11M
ROSEMEAD THS FLUID 17111
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
18
1. Place empty 5 gallon bucket under drain plug.
GRAVITY DOWN LIFTGATES
4. Reinstall ller cap (FIG. 18-1).
POWER DOWN LIFTGATES
1. Place empty 5 gallon bucket under drain plug.
CHANGING HYDRAULIC FLUID
PERIODIC MAINTENANCE
3. Remove ller cap (FIG. 18-1).
Re ll reservoir until hydraulic
uid level until level rises to the
full line (FIG. 18-1).
FULL LINE
CAUTION
Keep dirt, water and other contaminants from entering the hydraulic system.
Before opening the hydraulic uid reservoir ller cap, drain plug and hydraulic
lines, clean up contaminants that can get in the openings. Also, protect the
openings from accidental contamination.
Never mix synthetic uids with conventional hydraulic uids. Hydraulic system
must be purged if the uids are mixed.
NOTE: Exxon Univis HVI-13 hydraulic uid is recommended for operating tem-
peratures of -40 to +120° F. Refer to decal in pump box. The ISO-15 uids
in TABLE 17-1 may be used if the recommended uids are unavailable. If
necessary, the ISO-32 uids in TABLE 17-2 may be used where ordinary
seasonal temperatures are near +100° F or higher.
2. Open and lower platform. Remove the drain plug
(FIG. 18-1). Drain hydraulic uid from system.
Reinstall drain plug.
FILLER CAP
DRAIN PLUG
SINGLE PUMP BOX
FIG. 18-1
5. Reinstall ller cap (FIG. 18-1).
4. Remove ller cap (FIG. 18-1).
Re ll reservoir until hydraulic
uid level until level rises to the
full line (FIG. 18-1).
3. Open and lower platform. Remove the drain plug
(FIG. 18-1). Drain hydraulic uid from system.
Reinstall drain plug.
2. Press the POWER DOWN ON DEMAND button
on the column switch to set the Liftgate in Grav-
ity Down mode. Refer to Operation Manual for
instructions.
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
19
BLEEDING HYDRAULIC SYSTEM
1. Use UP/DOWN toggle switch to lower the
opened platform to the ground.
2. Loosen, but do not disconnect, the nut
connecting hydraulic line to tting on
pressure compensated ow control valve
(FIG. 19-1) at top of both cylinders.
3. Set the UP/DOWN switch on the RH runner in
the UP position for approximately one second
and then release the switch. Wait ten seconds
and then switch to UP and release. Repeat
this step until there is no air bubbling from the
loosened line ttings.
5. Use UP/DOWN toggle switch to raise and
lower the platform to make sure the Liftgate
operates correctly.
4. Tighten nut on hydraulic line (FIG. 19-1).
FIG. 19-1
NOTE: Perform this procedure at a place where Liftgate platform can be
lowered to lowest point of travel. Get a helper to operate Liftgate
control switch.
PRESSURE COMPENSATED
FLOW CONTROL VALVE
NUT
(HYDRAULIC
LINE)
FITTING
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
20
CLOSING CYLINDER REPLACEMENT
1. UNFOLD the platform. Lower the
platform (DOWN) to comfortable
height for work. Upper pin must be
lower than the bottom of the column
(see FIG. 20-1).
2. Disconnect the hydraulic hoses from
lower end of cylinder (FIG. 20-2). Plug
hoses to prevent spills.
3. Remove the upper roll pin (FIG. 20-2)
from the runner and then remove the
upper pin.
FIG. 20-2
RUNNER
HYDRAULIC HOSE
ROLL PIN
UPPER PIN
REPLACING PARTS
FIG. 20-1
UPPER PIN
(CLOSING
CYLINDER)
COLUMN
CYLINDER
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86

Maxon BMR-CS Maintenance Manual

Type
Maintenance Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI