Beckett CF2500 Owner's manual

Category
Stoves
Type
Owner's manual

This manual is also suitable for

www.beckettcorp.com
BECKETT
CF2500
COMMERCIAL OIL BURNER
R.W. Beckett Corporation
Elyria, Ohio
Speci cations
Fuels
U.S. #1 or #2 heating oil only (ASTM D396)
Canada #1 stove oil or #2 furnace oil only
DO NOT USE
GASOLINE,
CRANKCASE OIL, OR ANY OIL
CONTAINING GASOLINE.
Firing Range
CF2500A - 17.0 to 19.9 gph
CF2500 - 17.0 to 25.0 gph
Motor
2 HP 3450 rpm
208/230/60 Hz Standard
13.4 amps @ 230 VAC
Optional Voltages:
208, 230, 480, 575 VAC/3-PH,
50 or 60 Hz
Ignition Trans.
Continuous Duty, 120V/12,000V
Housing
Cast aluminum
Fuel Unit
100 to 300 psig
Oil Nozzle
45
o
to 70
o
Solid
Two-pipe Oil Flow
Features
S - Standard O - Optional N/A - Not Available
On/Off N/A
Linkageless Low/High/Low or Low/High/Off S
Air Proving Switch S
Direct Spark Ignition of Main Flame S
Flame Safeguard with UV Sensor or Light Sensor O
Customized Electrical Cabinet O
UL/CUL - CSD1 - XL GAPS
1
S
FM O
IRI (old standard) O
22.5
12.7
6.5
26.8 Min.
38.5 Max.
5.3
14.7
2
1
3
5
6
8
4
7
Standby
Motor-off
Delay
Valve-on
Delay
Trial for
Ignition
Ignition
Carryover
Run
Lockout
Recycle
9
Pump
Prime
Typical Burner Sequence of Operation - 7505
Overall Dimensions
200 - 300
PSIG
200 - 300
PSIG
Typical Wiring (Honeywell RM7897A control)
Combustion Chamber Dimensions
Firing Rate
(gph)
Minimum Dimensions
AL
17 10.5” 48.0”
22 11.5” 58.0”
27 12.5” 66.0”
32 12.5” 73.0”
35 13.0” 77.0”
2305
A
L
  • Page 1 1