Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if
instructions are not followed.
WARNING: A WARNING indicates a potential for property damage, personal
injury, or death.
____________________
© 2013 Dell Inc.
Trademarks used in this text: Dellâ„¢, the DELL logo, and PowerEdgeâ„¢ are trademarks of Dell Inc.
2013 - 09
Rev. A01
book.book Page 2 Friday, March 7, 2014 1:35 PM
Contents 3
Contents
1 About Your System. . . . . . . . . . . . . . . . . . 11
Accessing System Features During Startup. . . . . . . 11
Front-Panel Features and Indicators
. . . . . . . . . . 12
Back-Panel Features and Indicators . . . . . . . . . . 14
Guidelines for Connecting External Devices
. . . . . . 15
NIC Indicator Codes
. . . . . . . . . . . . . . . . . . . 16
Diagnostic Lights . . . . . . . . . . . . . . . . . . . . 17
System Messages
. . . . . . . . . . . . . . . . . . . . 19
Warning Messages
. . . . . . . . . . . . . . . . . . . 22
Diagnostics Messages
. . . . . . . . . . . . . . . . . 22
Alert Messages . . . . . . . . . . . . . . . . . . . . . 22
Other Information You May Need
. . . . . . . . . . . . 23
2 Using the System Setup Program
and Boot Manager . . . . . . . . . . . . . . . . . 25
Choosing the System Boot Mode . . . . . . . . . . . . 25
Entering the System Setup Program
. . . . . . . . . . . 26
Responding to Error Messages
. . . . . . . . . . . 26
System Setup Options
. . . . . . . . . . . . . . . . . . 27
book.book Page 3 Friday, March 7, 2014 1:35 PM
4 Contents
Main Screen . . . . . . . . . . . . . . . . . . . . 27
Memory Settings Screen . . . . . . . . . . . . . . 29
Processor Settings Screen
. . . . . . . . . . . . . 29
SATA Settings Screen
. . . . . . . . . . . . . . . . 30
Boot Settings Screen . . . . . . . . . . . . . . . . 31
Integrated Devices Screen
. . . . . . . . . . . . . 31
PCI IRQ Assignments Screen
. . . . . . . . . . . . 32
Serial Communication Screen . . . . . . . . . . . 33
Power Management Screen
. . . . . . . . . . . . 34
System Security Screen
. . . . . . . . . . . . . . 35
Exit Screen . . . . . . . . . . . . . . . . . . . . . 37
Entering the Boot Manager . . . . . . . . . . . . . . . 37
Using the Boot Manager Navigation Keys
. . . . . 38
Boot Manager Screen . . . . . . . . . . . . . . . 38
Boot Settings Screen
. . . . . . . . . . . . . . . . 39
System Utilities Screen
. . . . . . . . . . . . . . . 39
System and Setup Password Features
. . . . . . . . . . 40
Using the System Password
. . . . . . . . . . . . 40
Using the Setup Password . . . . . . . . . . . . . 42
Embedded System Management. . . . . . . . . . . . . 43
Baseboard Management Controller Configuration
. . . 44
Entering the BMC Setup Module
. . . . . . . . . . 44
iDRAC6 Configuration Utility
. . . . . . . . . . . . . . . 45
Entering the iDRAC6 Configuration Utility
. . . . . 45
3 Installing System Components . . . . . . . 47
Recommended Tools. . . . . . . . . . . . . . . . . . . 47
Inside the System
. . . . . . . . . . . . . . . . . . . . . 48
book.book Page 4 Friday, March 7, 2014 1:35 PM
Contents 5
Front Bezel (Optional) . . . . . . . . . . . . . . . . . . 49
Removing the Front Bezel
. . . . . . . . . . . . . 49
Installing the Front Bezel . . . . . . . . . . . . . . 49
Opening and Closing the System . . . . . . . . . . . . 50
Opening the System
. . . . . . . . . . . . . . . . 50
Closing the System . . . . . . . . . . . . . . . . . 51
Optical Drive (Optional) . . . . . . . . . . . . . . . . . 52
Removing an Optical Drive
. . . . . . . . . . . . . 52
Installing an Optical Drive . . . . . . . . . . . . . 54
Filler Panel. . . . . . . . . . . . . . . . . . . . . . . . 54
Removing a Filler Panel
. . . . . . . . . . . . . . . 55
Installing a Filler Panel . . . . . . . . . . . . . . . 55
Hard Drives. . . . . . . . . . . . . . . . . . . . . . . . 56
Removing a 3.5-Inch Hard Drive
. . . . . . . . . . 56
Installing a 3.5-Inch Hard Drive. . . . . . . . . . . 58
Removing a 3.5-Inch Hard Drive From a
Hard-Drive Carrier . . . . . . . . . . . . . . . . . 59
Installing a 3.5-Inch Hard Drive Into a
Hard-Drive Carrier
. . . . . . . . . . . . . . . . . 60
Expansion Card
. . . . . . . . . . . . . . . . . . . . . 61
Expansion Card Installation Guidelines
. . . . . . 61
Removing an Expansion Card
. . . . . . . . . . . 61
Installing an Expansion Card . . . . . . . . . . . . 62
Expansion-Card Riser . . . . . . . . . . . . . . . . . . 63
Removing an Expansion-Card Riser
. . . . . . . . 63
Installing an Expansion-Card Riser
. . . . . . . . . 65
Internal USB Memory Key
. . . . . . . . . . . . . . . . 65
Cooling Shroud
. . . . . . . . . . . . . . . . . . . . . . 66
Removing the Cooling Shroud
. . . . . . . . . . . 67
book.book Page 5 Friday, March 7, 2014 1:35 PM
6 Contents
Installing the Cooling Shroud . . . . . . . . . . . . 69
System Memory
. . . . . . . . . . . . . . . . . . . . . 69
General Memory Module
Installation Guidelines
. . . . . . . . . . . . . . . 69
Mode-Specific Guidelines . . . . . . . . . . . . . 70
Installing Memory Modules
. . . . . . . . . . . . . 71
Removing Memory Modules
. . . . . . . . . . . . 73
Cooling Fans
. . . . . . . . . . . . . . . . . . . . . . . 74
Removing a Cooling Fan
. . . . . . . . . . . . . . 74
Installing a Cooling Fan
. . . . . . . . . . . . . . . 75
iDRAC6 Express Card (Optional)
. . . . . . . . . . . . . 76
Installing an iDRAC6 Express Card
. . . . . . . . . 76
Removing an iDRAC6 Express Card
. . . . . . . . . 78
iDRAC6 Enterprise Card (Optional)
. . . . . . . . . . . 79
Installing an iDRAC6 Enterprise Card
. . . . . . . . 79
Removing an iDRAC6 Enterprise Card
. . . . . . . 81
VFlash Media (Optional)
. . . . . . . . . . . . . . . . . 82
Installing a VFlash Media Card
. . . . . . . . . . . 82
Removing a VFlash Media Card . . . . . . . . . . 82
Processor. . . . . . . . . . . . . . . . . . . . . . . . . 82
Removing a Processor
. . . . . . . . . . . . . . . 82
Installing a Processor. . . . . . . . . . . . . . . . 86
Power Supply . . . . . . . . . . . . . . . . . . . . . . 87
Removing the Power Supply
. . . . . . . . . . . . 87
Installing the Power Supply. . . . . . . . . . . . . 89
System Battery
. . . . . . . . . . . . . . . . . . . . . . 89
Replacing the System Battery
. . . . . . . . . . . 89
Control Panel Assembly
. . . . . . . . . . . . . . . . . 91
book.book Page 6 Friday, March 7, 2014 1:35 PM
Contents 7
Removing the Control Panel Assembly. . . . . . . 91
Installing the Control Panel Assembly . . . . . . . 93
System Board . . . . . . . . . . . . . . . . . . . . . . 93
Removing the System Board
. . . . . . . . . . . . 93
Installing the System Board . . . . . . . . . . . . 95
4 Troubleshooting Your System . . . . . . . . . 97
Safety First—For You and Your System . . . . . . . . . 97
Troubleshooting System Startup Failure
. . . . . . . . 97
Troubleshooting External Connections
. . . . . . . . . 97
Troubleshooting the Video Subsystem . . . . . . . . . 98
Troubleshooting a USB Device
. . . . . . . . . . . . . 98
Troubleshooting a Serial I/O Device
. . . . . . . . . . 99
Troubleshooting a NIC
. . . . . . . . . . . . . . . . . . 99
Troubleshooting a Wet System . . . . . . . . . . . . . 100
Troubleshooting a Damaged System
. . . . . . . . . . 101
Troubleshooting the System Battery
. . . . . . . . . . . 102
Troubleshooting Power Supply . . . . . . . . . . . . . 103
Troubleshooting System Cooling Problems
. . . . . . . 103
Troubleshooting a Fan
. . . . . . . . . . . . . . . . . . 103
Troubleshooting System Memory
. . . . . . . . . . . . 104
Troubleshooting an Internal USB Key
. . . . . . . . . . 106
Troubleshooting an Optical Drive
. . . . . . . . . . . . 107
book.book Page 7 Friday, March 7, 2014 1:35 PM
8 Contents
Troubleshooting a Hard Drive . . . . . . . . . . . . . 108
Troubleshooting an Expansion Card
. . . . . . . . . . 109
Troubleshooting the Processor
. . . . . . . . . . . . 110
5 Running the System Diagnostics. . . . . . 111
Using Online Diagnostics . . . . . . . . . . . . . . . 111
Embedded System Diagnostics Features
. . . . . . . 111
When to Use the Embedded System Diagnostics
. . . 112
Running the Embedded System Diagnostics . . . . . 112
System Diagnostics Testing Options
. . . . . . . . . . 112
Using the Custom Test Options
. . . . . . . . . . . . 113
Selecting Devices for Testing
. . . . . . . . . . . 113
Selecting Diagnostics Options
. . . . . . . . . . 113
Viewing Information and Results . . . . . . . . . 113
6 Jumpers and Connectors. . . . . . . . . . . . 115
System Board Jumpers. . . . . . . . . . . . . . . . . 115
System Board Connectors
. . . . . . . . . . . . . . . 116
Disabling a Forgotten Password
. . . . . . . . . . . . 118
7 Getting Help. . . . . . . . . . . . . . . . . . . . . . 119
Contacting Dell. . . . . . . . . . . . . . . . . . . . . 119
book.book Page 8 Friday, March 7, 2014 1:35 PM
Contents 9
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
book.book Page 9 Friday, March 7, 2014 1:35 PM
10 Contents
book.book Page 10 Friday, March 7, 2014 1:35 PM
About Your System 11
3
About Your System
Accessing System Features During Startup
The following keystrokes provide access to system features during startup.
Keystroke Description
<F2> Enters the System Setup program. See "Using the System Setup
Program and Boot Manager" on page 25.
<F10> Enters System Services, which opens the Dell Unified Server
Configurator (USC). The Dell USC allows you to access utilities such
as embedded system diagnostics. For more information, see the
Unified Server Configurator documentation at
support.dell.com/manuals.
<F11> Enters the Boot Manager, depending on the system’s boot
configuration. See "Using the System Setup Program and Boot
Manager" on page 25.
<F12> Starts PXE boot.
<Ctrl><E> Enters the Baseboard Management Controller (BMC) or Integrated
Dell Remote Access Controller (iDRAC) Configuration Utility, which
allows access to the System Event Log (SEL) and configuration of
remote access to the system. For more information, see the BMC or
iDRAC user documentation at support.dell.com/manuals.
<Ctrl><C> Enters the SAS Configuration Utility. For more information, see your
SAS adapter documentation.
<Ctrl><R> Enters the RAID configuration utility. For more information, see the
documentation for your SAS RAID card.
<Ctrl><S> Enters the utility to configure NIC settings for PXE boot. For more
information, see the documentation for your integrated NIC.
book.book Page 11 Friday, March 7, 2014 1:35 PM
12 About Your System
Front-Panel Features and Indicators
Figure 3-1. Front-Panel Features and Indicators
Item Indicator, Button, or
Connector
Icon Description
1Power-on indicator/
power button
The power-on indicator lights when the
system power is on.
The power button controls the DC
power supply output to the system.
When the system bezel is installed, the
power button is not accessible.
NOTE: When powering on the system, the
video monitor can take from several
seconds to over 2 minutes to display an
image, depending on the amount of
memory installed in the system.
NOTE: On ACPI-compliant operating
systems, turning off the system using the
power button causes the system to
perform a graceful shutdown before
power to the system is turned off.
2 NMI button Used to troubleshoot software and
device driver errors when using certain
operating systems. This button can be
pressed using the end of a paper clip.
Use this button only if directed to do so
by qualified support personnel or by the
operating system's documentation.
12345 8
9
1067 9
book.book Page 12 Friday, March 7, 2014 1:35 PM
About Your System 13
3 Video connector Connects a monitor to the system.
4 Hard-drive activity
indicator
Lights up when the hard drive is in use.
5 Diagnostic indicator
lights (4)
The four diagnostic indicator lights
display error codes during system
startup. See "Diagnostic Lights" on
page 17.
6System status
indicator
Lights blue during normal
system operation.
Lights amber when the system needs
attention due to a problem.
7 System identification
button
The system identification buttons on
the front and back panels can be used to
locate a particular system within a rack.
When one of the buttons is pushed, the
system status indicators on the front and
back panels light blue until one of the
buttons is pushed again.
8 USB connectors (2) Connect USB devices to the system. The
ports are USB 2.0-compliant.
9 System identification
panel
A slide-out panel for system information
including the Express Service Tag,
embedded NIC MAC address, and
iDRAC6 Enterprise card MAC address.
Space is provided for an additional label.
10 Optical drive
(optional)
One optional slim-line SATA
DVD-ROM or DVD+/-RW drive, or
combination CD-RW/DVD drive (when
available).
NOTE: DVD devices are data only.
Item Indicator, Button, or
Connector
Icon Description
book.book Page 13 Friday, March 7, 2014 1:35 PM
14 About Your System
Back-Panel Features and Indicators
Figure 3-2 shows the controls, indicators, and connectors located on the
system's back panel.
Figure 3-2. Back-Panel Features and Indicators
Item Indicator, Button, or
Connector
Icon Description
1 iDRAC6 Enterprise
port (optional)
Dedicated management port for the
optional iDRAC6 Enterprise card.
2 VFlash media slot
(optional)
Connects an external SD memory card
for the optional iDRAC6 Enterprise
card.
3PCIe expansion card
slot
Connects a PCI Express expansion
card.
4 Serial connector Connects a serial device to the system.
5 Video connector Connects a VGA display to the system.
6 eSATA Connects additional storage devices.
7 USB connectors (2) Connect USB devices to the system.
The ports are USB 2.0-compliant.
8 Ethernet connectors (2) Embedded 10/100/1000 NIC
connectors.
12 4
13
5678 91011 12
3
book.book Page 14 Friday, March 7, 2014 1:35 PM
About Your System 15
Guidelines for Connecting External Devices
• Turn off power to the system and external devices before attaching a new
external device. Turn on any external devices before turning on the system
(unless the documentation for the device specifies otherwise).
• Ensure that the appropriate driver for the attached device has been
installed on the system.
• If necessary to enable ports on your system, use the System Setup program.
S
ee "Entering the System Setup Program" on page 26.
9 System status indicator Lights blue during normal
system operation.
Lights amber when the system needs
attention due to a problem.
10 System identification
button
The system identification buttons on
the front and back panels can be used
to locate a particular system within a
rack. When one of the buttons is
pushed, the system status indicators on
the front and back panels light blue
until one of the buttons is pushed
again.
11 System identification
connector
Connects the optional system status
indicator assembly through the
optional cable management arm.
12 Power supply 250 W power supply.
13 Retention clip Secures the power cable.
Item Indicator, Button, or
Connector
Icon Description
book.book Page 15 Friday, March 7, 2014 1:35 PM
16 About Your System
NIC Indicator Codes
Figure 3-3. NIC Indicator Codes
1 link indicator 2 activity indicator
Indicator Indicator Code
Link and activity
indicators are off
The NIC is not connected to the network.
Link indicator is green The NIC is connected to a valid network link at 1000
Mbps.
Link indicator is amber The NIC is connected to a valid network link at 10/100
Mbps.
Activity indicator is green
blinking
Network data is being sent or received.
1
2
book.book Page 16 Friday, March 7, 2014 1:35 PM
About Your System 17
Diagnostic Lights
The four diagnostic indicator lights on the system front panel display error
codes during system startup. Table 3-1 lists the causes and possible corrective
actions associated with these codes. A highlighted circle indicates the light is
on; a non-highlighted circle indicates the light is off.
Table 3-1. Diagnostic Indicator Codes
Code Causes Corrective Action
The system is in a normal
off condition or a possible
pre-BIOS failure has
occurred.
The diagnostic lights are
not lit after the system
successfully boots to the
operating system.
Plug the system into a working
electrical outlet and press the
power button.
The system is in a normal
operating condition after
POST.
Information only.
BIOS checksum failure
detected; system is in
recovery mode.
See "Getting Help" on page 119.
Possible processor failure. See "Troubleshooting the
Processor" on page 110.
Memory failure. See "Troubleshooting System
Memory" on page 104.
Possible expansion card
failure.
See "Troubleshooting an
Expansion Card" on page 109.
Possible video failure. See "Getting Help" on page 119.
book.book Page 17 Friday, March 7, 2014 1:35 PM
18 About Your System
Hard drive failure. Ensure that the diskette drive and
hard drive are properly connected.
See "Hard Drives" on page 56 for
information on the drives
installed in your system.
Possible USB failure. See "Troubleshooting a USB
Device" on page 98.
No memory modules
detected.
See "Troubleshooting System
Memory" on page 104.
System board failure. See "Getting Help" on page 119.
Memory configuration
error.
See "Troubleshooting System
Memory" on page 104.
Possible system board
resource and/or system
board hardware failure.
See "Getting Help" on page 119.
Possible system resource
configuration error.
See "Getting Help" on page 119.
Other failure. Ensure that the optical drive and
hard drives are properly
connected. See "Troubleshooting
Your System" on page 97 for the
appropriate drive installed in your
system. If the problem persists,
see "Getting Help" on page 119.
Code Causes Corrective Action
book.book Page 18 Friday, March 7, 2014 1:35 PM
About Your System 19
System Messages
System messages appear on the screen to notify you of a possible problem
with the system.
NOTE: If you receive a system message not listed in the table, check the
documentation for the application that is running when the message appears or the
operating system's documentation for an explanation of the message and
recommended action.
Message Causes Corrective Actions
BIOS
MANUFACTURING
MODE detected.
MANUFACTURING
MODE will be
cleared before
the next boot.
System reboot
required for
normal
operation.
System is in manufacturing
mode.
Reboot to take the system
out of manufacturing mode.
Caution!
NVRAM_CLR jumper
is installed on
system board.
Please run
SETUP.
NVRAM_CLR jumper is
installed in the clear setting.
CMOS has been cleared.
Move the NVRAM_CLR
jumper to the default
position (pins 3 and 5). See
Figure 8-1 for jumper
location. Restart the system
and re-enter the BIOS
settings. See "Using the
System Setup Program and
Boot Manager" on page 25.
Invalid
configuration
information -
please run SETUP
program.
An invalid system
configuration caused a
system halt.
Run the System Setup
program and review the
current settings. See "Using
the System Setup Program
and Boot Manager" on
page 25.
Keyboard
controller
failure.
Faulty keyboard controller;
faulty system board.
See "Getting Help" on
page 119.
book.book Page 19 Friday, March 7, 2014 1:35 PM
20 About Your System
Keyboard data
line failure.
Keyboard stuck
key failure.
Keyboard cable connector is
improperly connected or the
keyboard is defective.
Reseat the keyboard cable. If
the problem persists, see
"Troubleshooting a USB
Device" on page 98.
Manufacturing
mode detected.
System is in manufacturing
mode.
Reboot to take the system
out of manufacturing mode.
Memory
Initialization
Warning: Memory
size may be
reduced.
Invalid memory
configuration. The system
will run but with less
memory than is physically
available.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines" on
page 69.
No boot device
available.
Faulty or missing optical
drive subsystem, hard drive,
or hard-drive subsystem, or
no bootable USB key
installed.
Use a bootable USB key, CD,
or hard drive. If the problem
persists, see
"Troubleshooting a USB
Device" on page 98,
"Troubleshooting an Optical
Drive" on page 107, and
"Troubleshooting a Hard
Drive" on page 108. See
"Using the System Setup
Program and Boot Manager"
on page 25 for information
on setting the order of boot
devices.
PCI BIOS failed
to install.
PCIe device BIOS (Option
ROM) checksum failure
detected during shadowing.
Cables to expansion card
loose; faulty or improperly
installed expansion card.
Reseat the expansion card.
Ensure that all appropriate
cables are securely connected
to the expansion card. If the
problem persists, see
"Troubleshooting an
Expansion Card" on
page 109.
Message Causes Corrective Actions
book.book Page 20 Friday, March 7, 2014 1:35 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126

Dell R210 II User manual

Category
Servers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI