Whitehall Manufacturing WHD2898-SO Panel Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Whitehall Manufacturing WHD2898-SO Panel Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
TM
Dignity Suite Ligature Resistant
Recessed Sensor Operated
Flush Valve Cover Assembly
®
6900-223-001 Rev A: 10/03/2022
NOTES:
1. In-wall Mounting Frame
2. Upper and Lower Access Panels
3. Infra-red Sensor Plate/ Pushbutton Override
4. 1/4” Vandal Resistant Fasteners
5. Whitehall WHD-GB36 Grab Bar (Shown for reference only)
6. Whitehall BestCare Toilet WH2142-ADA-W (Shown for reference only)
®
5
6
SIDE VIEW
FRONT VIEW
MODEL# WHD2898-SO
2"
[49]
1
24"
[609]
93
4"
[248]
12 1
2"
[317]
13
4"
[44]
31
4"
[82]
14"
[355]
12"
[308]
C
L
2
3
2
4
22"
[559]
WHD2898-SO
Note: 120/24 VAC Transformer
protected with a GFCI is required and
shall be provided by others
Refer to Flush Valve Manufacture’s
complete Installation Instructions for
details.
C he c k l o ca l E l ec t r ic a l C o de
requirements to ensure compliance.
2
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
2
1
2
4
3
12
[311]
1
4"
22 1
8"
[562]
MINIMUM OF 6” DEPTH
TO ACCOMMODATE
IN-WALL FLUSH VALVE
19” TO 20”
SEE NOTE**
5
WHD2898-SO FIXTURE ANCHORING
1
2
Install Finished Wall and ensure a Wall Opening with the
dimensions shown.
Finished Wall (Suggested Thickness = 0.5” ± 0.25”)
Mounting Frame Assy.
Finished Floor
2
1
3
Install 12” x 22” Mounting Frame Assembly into Wall Opening and Secure
using Installer Provided Fasteners (12) Places. Ensure frame is level.
Stud Wall Reference
Mounting Frame Assembly
Blockout Area
2
1
3
Installer Provided Fasteners
to suit wall conditions
4
N O T E : A c c e s s a b i l i t y
standards may dictate
grab bar height for reach
range. Verify requirements.
NOTE** RECOMMENDED HEIGHT
T O P O S I T I O N W H I T E H A L L
WHD-GB AT 34.5” TO 35.5” TO TOP
OF GRIPPING SURFACE.
Finished Floor
5
INSTALLATION, OPERATION & MAINTENANCE MANUAL WH2898D-SO
71
2"
[191]
4
[102]
"
10 1
2"
[267]
19” TO 20”
SEE NOTE**
1
2
3
12
[305]
"
3
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
3
WHD2898-SO FIXTURE ANCHORING
3
4
Install Flush Valve Upper Access and Lower Access Panels to
Mounting Frame and Secure using 1/4” Screws (Provided).
Install SLOAN Sensor onto Flush Valve Lower Access Panel using
3/8” Screws (Provided).
Sensor Operated Flush Valve
Lower Access Panel
3/8” Screws (Provided)
SLOAN Sensor
2
1
3
1
2
3
Flush Valve Upper Access Panel
Sensor Operated Flush Valve
Lower Access Panel
1/4” Screws (Provided)
2
1
3
Mounting Frame Assembly
4
1
4
3
2
N O T E : A c c e s s a b i l i t y
standards may dictate
grab bar height for reach
range. Verify requirements.
INSTALLATION, OPERATION & MAINTENANCE MANUAL WH2898D-SO
/