Airpura P700 User guide

Type
User guide

Airpura P700 is a powerful air purifier designed to clean and improve indoor air quality. Equipped with a true HEPA filter, it effectively removes 99.97% of airborne particles as small as 0.3 microns, including dust, pollen, and bacteria. The activated carbon filter absorbs odors and harmful chemicals, such as VOCs and smoke. With a variable speed control, you can adjust the airflow to your desired level, ensuring a quiet and efficient operation. Ideal for use in homes, offices, and other indoor spaces, the Airpura P700 promotes a healthier and cleaner environment for you and your family.

Airpura P700 is a powerful air purifier designed to clean and improve indoor air quality. Equipped with a true HEPA filter, it effectively removes 99.97% of airborne particles as small as 0.3 microns, including dust, pollen, and bacteria. The activated carbon filter absorbs odors and harmful chemicals, such as VOCs and smoke. With a variable speed control, you can adjust the airflow to your desired level, ensuring a quiet and efficient operation. Ideal for use in homes, offices, and other indoor spaces, the Airpura P700 promotes a healthier and cleaner environment for you and your family.

OPER ATING
&
FILTER REPLACEMENT
DIRECTIONS
P700
To close the lter chamber
Replace
the gasket
Position the
indentation in the cover
into the center of the
HEPA lter
Replace
the 4 screws
and tighten
Turn the Airpura
back on casters
Insert the tube
into the lter
chamber inside
the Prelter
Let the spiral
open to ll
the opening
Open the top of the
spiral to make a
slight funnel
Insert the
Carbon canister into
the funnel and hold it
straight
Position the
Prelter inside
the lter
chamber
Place a felt gasket at
the bottom of the
lter chamber
Unfold the lter slider
(Supplied with replacement
lters or on request
Part#6F 001)
Roll it
into a spiral
Let the canister
slide down
thelter slider
Pull the lter slider up
out of the cavity using
both hands and let the
canister slide to the
bottom of the cavity
Remove the lter
slider and fold it
for further use
Slide in the
Hepa lter
To open the lter chamber
Turn over
the Airpura
Remove the 4
retaining screws
Take off
the cover
Remove
the gasket
Air puriers models and lter congurations
Technical specications
HEPA 600RVHU Filter
(99.97 % ecient @ 0.3 Microns)
3 to 5 years
P714 : HEPA 14 Filter
(99.99% ecient @ 0.3 Microns)
P700+ : HEPA 600 Filter w/ TiO2
(99.97% ecient @ 0.3 Microns)
P714+ : HEPA 14 Filter
(99.99% ecient @ 0.3 Microns) +
TiO2
18 lbs, Coconut Shell Carbon
Filter (100% Blend)
24 months
Titanclean
18-20 months
UV bulb
18-20 months
Poly Prelter 600 2-pack
12 months
Particle removal
Over 100 ft2 true HEPA
(Measured only 1 side)
12 pleats per inch
Pleats warm rolled with separators
Activated carbon lter
18 lbs carbon lter
13"H X 13.25"OD X 9"ID
Carbon Bed
2” deep X 570 sq. surface
Air Flow 635 cfm
More cfm than any other
home unit available
Prelter
570 in2 x 1 in
Housing
Powder coat steel
Size
23 in x 15 in
Weight
35 lbs total
Watts
120 on high / 40 on low
Sound Level
30.2* db on low (at 6 feet)
63.0 db on high (635 cfm)
*at test conditions
Voltage options
115 or 220 volts
Prelter Particule Carbon
Alternates Cotton Prelter
TarBarrier Prelter 18 lbs anthracite carbon lter (100%)
Upgrade HEPA 14 Filter (99.99  %
ecient @ 0.3 Microns)
ULPA Filter (99.9999  %
ecient @ 0.1 Microns)
18 lbs impregnated carbon
18 lbs carbon (17% potassium permaga-
nate carbon, 83% coconut shell
TO BEGIN USING YOUR
AIRPURA
Inspect the exterior of your Airpura to verify there is no damage from shipping.
If any damage is noted, please follow the instructions from the distributor returns
policy.
Wipe the unit with a damp cloth to remove any dust from packaging
Plug the unit into a regular grounded 110 volt outlet 2 Turn the unit on
Turn on the unit to MAX and allow it to run for at least 30 minutes
Set the variable speed control to the level you wish
Always maintain a humidity level of 40% in your home to ensure the
unit is operating at optimal levels. When using purifer with a
dehumidier, please keep dehumidier at least 6 feet away.•.It is recommended to run your
purifier at low speeds, 24 hours a day, 7 days a week. Running it at a low speed allows for
maximum dwell time of chemicals and VOCs in the air through both the carbon and
HEPA filters thus delivering superior filtration.
MaxMin
Off
MaxMin
Off
MaxMin
Off
Replacing the UV bulb
Open the lter chamber following
the instructions
Pull the bulb upward out of the
connector
Push the replacement bulb rmly
into the connector
Close the lter chamber following
instructions
The Prelter
Can be vacuumed from the exterior of the
unit once a month or more often.
Should be replaced at least after 12
months of use
To vacuum the Prelter
Use the brush attachment on your
vacuum cleaner
Vacuum slowly around the mesh surface
of the lter chamber
IMPORTANT SAFETY NOTE
Please ensure air purier is turned OFF when plugging into a power
source.
Failure to do so may result in motor potentially stalling and/or burning.
FILTER MAINTENANCE AND REPLACEMENT
3067330 60950
Airpura Industries - 5510 Boul. des Rossignols, Laval, QC, Canada. H7L 5W6
EPA Est.:100723-CAN-1
  • Page 1 1
  • Page 2 2

Airpura P700 User guide

Type
User guide

Airpura P700 is a powerful air purifier designed to clean and improve indoor air quality. Equipped with a true HEPA filter, it effectively removes 99.97% of airborne particles as small as 0.3 microns, including dust, pollen, and bacteria. The activated carbon filter absorbs odors and harmful chemicals, such as VOCs and smoke. With a variable speed control, you can adjust the airflow to your desired level, ensuring a quiet and efficient operation. Ideal for use in homes, offices, and other indoor spaces, the Airpura P700 promotes a healthier and cleaner environment for you and your family.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI