KitchenAid KDRP487M User manual

  • Hello! I am an AI chatbot trained to assist you with the KitchenAid KDRP487M User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
48" Commercial Style Dual Fuel Range
with self-cleaning thermal/convection oven
®
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
KDRP487M
Gas supply: Use 3/4" rigid pipe gas supply line
to the range location. A smaller size pipe on long
runs may result in insufficient gas supply. With
L.P. gas, piping or tubing size can be 1/2"
minimum. If local codes permit, it is
recommended that new flexible metal tubing,
design-certified by AGA or CSA, 4-5 feet long,
5/8-inch I.D., be used for connecting the range to
the rigid gas supply line. A 1/2" male pipe thread is
needed for connection to pressure regulator
female pipe threads. An individual manual shutoff
valve must be located in the same room, but
external to the range.
Electrical: A four-wire or three-wire, single
phase, 240-volt, 60-Hz, AC-only, electrical supply
is required on a separate 50 amp circuit, fused on
both sides of the line. A time-delay fuse or circuit
breaker is recommended.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8302571
12-07-04
*NOTE: 49" (124.5 cm) min. when bottom of wood or metal
cabinet is protected by not less than 1/4" (0.64 cm) flame
retardant millboard covered with not less than No. 28 MSG
sheet steel, 0.015" (0.4 mm) stainless steel, 0.024"
(0.6 mm) aluminum or 0.020" (0.5 mm) copper.
55" (139.7 cm) min. clearance between the top of the
cooking platform and the bottom of an unprotected wood
or metal cabinet.
13" (33 cm) max.
upper cabinet depth
48" (121.9 cm) min.
upper cabinet width
48-1/4" (122.6 cm)
opening width
20"
(50.8 cm)
12"
(30.5 cm)
5-1/2" (14 cm)
8"
(20.3 cm)
18" (45.7 cm)
upper cabinet
to countertop
gas line opening to be
located in this area
junction box to be
located in this area
12" (30.5 cm) min.
clearance from both sides
of range to side wall or
other combustible material
above cooking surface
0" (0 cm) clearance from
both sides and back of
range to adjacent
combustible construction
below cooking surface
For minimum
clearance to top of
range, see NOTE.*
40"
(101.6 cm)
4"
(10.2 cm)
3" (7.6 cm) maximum
gas line height
3-1/2" (8.9 cm)
maximum junction
box height
48" (121.9 cm)
cooktop width
48" (121.9 cm)
width
13-1/2"
(34.3 cm)
36" (91.4 cm)
cooktop
height with
feet loosened
3/4 turns
NOTE: regulator
located at center
bottom of range.
48" (121.9 cm) range with
all sealed burners shown
49-1/2" (125.7 cm)
overall height
1/4" (6.4 mm)
spacer
26-1/2" (67.3 cm)
depth with
control panel
/