Minka Ceiling Fan Co. 84037 User manual

Type
User manual
52" Ceiling Fan for Indoor Location
Galeventi
2020
84035/84036/84037
The Minka warranty is for one (1) year from the date of purchase from an authorized Minka dealer. This warranty is only
valid to the original purchaser or user against all defects in material and workmanship (light bulbs excluded) for one (1)
full year. Additionally, Minka warrants the motor only for the lifetime of the Minka ceiling fan (excluding wall controls and
electrical components), to the original purchaser or user.
The warranty is void with the use of any non-Minka electrical devices; e.g., wall controls or electrical dimmer switches,
etc.
The warranty is void once the original purchaser or user ceases to own the fan or the fan is moved from its original
point of installation.
The warranty is void with the use of any hanger bracket (non-Minka or non-fan specific) other than the hanger bracket
supplied in the box.
7
8
9
ELECTRICAL CONNECTIONS
OPERATING THE REMOTE CONTROL
CARE OF YOUR FAN
TROUBLESHOOTING
INSTALLING THE CANOPY AND CANOPY COVER
HANGING THE FAN
10
11
12
12
13
INSTALLING THE 16W LED ASSEMBLY
9
INSTALLING THE BLADE TO THE FLYWHEEL
DL-1167RYS-02
DL-4103S
9. Flywwheel (preassembled) (1)
10. 16W LED assembly
11. Receiver(1) + wire nut (6)
12. Transmitter + holder + 2 mounting
screws + 12 V battery
3
4
5
7
11
9
6
5
A. Blade attachment hardware:
3/6" x 18mm blade screw ( 15 + 1 spare)
Fiber washer ( 15 + 1 spare)
B. Wire nut (3)
C. Balancing kit
C
6
10
8
2
12
Blade holder (5)
8.
Secure the outlet box directly to the building structure. Use appropriate fasteners and building materials. The outlet
box and its support must be able to fully support the moving weight of the fan (at least 35 Ibs.). Use a UL Listed metal
outlet box. Do not use a plastic outlet box.
You may need a longer downrod to maintain proper blade clearance when installing on a steep, sloped ceiling.
Longer downrods are available from your Minka dealer.
To hang your fan where there is an existing fixture but no ceiling joist, you may need to install a hanger bar as shown
in Fig. 4 (available at your Minka dealer).
7
5
5 6 7
8
10
6
7
8
9
9
All of the parts, hardware and components such as the hanger bracket and hanger ball have been
provided for your safety and the proper installation of your new ceiling fan. The use of other parts, hardware or
components not supplied by Minka with the fan will void the Minka Warranty.
9
10
6
seats
slot
8
11
12
13
Note: After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the
outlet box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductoron
one side of the outlet box and ungrounded conductor on the other side of the outlet box.
DIP SWITCH
13
DOWN LIGHT
11
13
(“ DOWN LIGHT”)
Step 4. Connect the groud wire (green or bare copper) from the outlet box to the ground wire of hanging ball and the
ground wire of mounting bracket. Secure wire connection with the plastic wire nut provided. (Fig.13)
12
14
FIG. 14
9
BLADE
BLADE
SCREW
FIBER
WASHER
INSTALLING THE BLADE TO THE FLYWHEEL
FLYWHEEL
FIG. 15-a
INSTALLING THE CANOPY AND CANOPY COVER
OUTLET BOX
HANGER
BRACKET
HANG
BALL
CANOPY
CANOPY
COVER
BLADE
SCREW
FIBER WASHER
FIG. 15-b
Insert the blade through the slot on the flywheel. Starting from the center hole, fasten the blade to the flywheel by using
the blade screw and fiber washer(Fig.15-a). Align blade holder to the blade (as shown in Fig.15-b) and secure using two
blade screws and two fiber washers. Repeat this step for the other four blades.
BLADE
BLADE HOLDER
10
INSTALLING THE 16W LED ASSEMBLY
Step 1. While holding the 16W LED assembly under your fan, firmly snap the wire connection plugs together.
Step 2. Attach the 16W LED assembly to the switch box by twisting tightly.
NOTE: This is an integrated LED light kit assembly and can not be disassembled to prevent electronic shock.
FIG. 16
SWITCH BOX
WIRE CONNECTION
PLUGS
16W LED ASSEMBLY
CAUTION: To Reduce The Risk Of Electric Shock, Disconnect The Electrical Supply Circuit To The Fan
Before Installing The Light Kit.
FIG. 18 FIG. 19
FIG. 20 FIG. 21 FIG. 22
17
11
: Low speed : Medium speed : High speed
The reverse switch is located under the coupling cover (Figue 20). Slide the switch to left for warm weather
operation. Slide the switch to right for cool weather operation.
22
21
summer or winter
Summer Weather (counter clockwise blade rotation)
Winter Weather (Clockwise blade rotation)
12
13
52
120
120
0.25 16.23 74 2072
0.48 56.96 160 4789
8.117.1 1.435
Estimated
Yearly Energy Cost
Cost Range of Similar Models (19” - 84”)
All estimates based on typical use, excluding lights
Cubic Feet Per Minute
ftc.gov/energy
more air the fan will move
91
Feet Per Minute Per Watt
3,516
Based on 12 cents per kWh and 6.4 hours use per day
Your cost depends on rates and use
Energy Use: 39 Watts
$
11
$
34
$
3
MINKA CEILING FAN CO.
XXXXX
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This device must accept any interference received, including
interference that may cause undesired operation.
Warning: Changes or modification to this unit not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to be comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is not guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the use is encouraged to try and correct the interference by one or more of the
following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment
and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected. Consult the dealer or an experienced radio/TV technician for help.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Minka Ceiling Fan Co. 84037 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI