Salda Ptouch User manual

Type
User manual
Ragainės g. 100, LT-78109 Šiauliai, Lithuania
Tel. (+370 41) 540415
Fax. (+370 41) 540417
www.salda.lt
•Remotecontrolpanel
Ptouch
Usermanual
MCB
Art.-no. PRGPU081
MCB_P0097_AZ_0001
1GENERALINFORMATION...................................................................................................... 3
2USERMANUAL.......................................................................................................................... 3
2.1 Main window ..................................................................................................................... 3
2.2 Temperature setting window ...................................................................................... 4
2.3 Operation mode selection window .......................................................................... 5
2.4 Menu .................................................................................................................................... 6
2.5 Device status window .................................................................................................... 7
2.6 Night cooling ..................................................................................................................... 9
2.7 Fans boost ........................................................................................................................ 10
2.8 Set points ......................................................................................................................... 11
2.9 Filter timer ........................................................................................................................ 12
2.10 Heating season settings ............................................................................................13
2.11 Date and time ............................................................................................................... 14
2.11 Weekly scheduler .........................................................................................................15
2.12 Holiday scheduler ....................................................................................................... 16
2.14 Alarms ............................................................................................................................. 17
2.15 Settings menu .............................................................................................................. 17
2.15.1 Language selection ..........................................................................................18
2.15.2 Theme selection .................................................................................................19
2.15.3 Child protection lock settings .......................................................................19
2.15.4 Screen brightness and dimming settings ................................................ 20
2.15.5 Sound settings ................................................................................................... 21
TABLE OF
CONTENTS
3
GENERAL INFORMATION 1
Ptouchremotecontrolpanelisdesignedfor:
• SALDA ventilation units and other devices based on PRV, MCB or ECO controllers;
• Modbus-controlled devices.
Remote control panels guarantee optimal comfort of operation, monitoring, maintenance and service. All
operations can be performed using remote panel, which displays the status of the system, fault reports
and service settings.
Features:
• Simple use;
• Surface mounted;
• 4.3” touch-screen;
• Display of functions and set points;
• Acoustic response to touch;
• Maximum fan speed setting for limited time period (BOOST);
• Blocking (locking) - protection from children;
• User menu for fan speed, mode, status, CO2 control settings.
Packageincludes:
• 1x Ptouch control panel;
• 1x Cable;
• 1x Manual;
• 2x Fastening elements (screw 3,9 x 25 DIN 7981 – 2 pcs nylon plug 5x25 – 2 pcs, hammered steel plug
12x30 – 2 pcs).
USER MANUAL 2
2.1Mainwindow
EN
B1
I7
I6
B5
I4
B3
B4
B2
I1
I2
I5
I3
4
Number Function
Date and time.
Information / alert / status box.
Operating mode (comfort, max boost, stand-by, building protection
or economy).
Temperature of outside air
Desired room temperature (in comfort mode) or selected operating
mode icon.
Temperature of extracted air (room temperature).
Temperature of supplied air.
Number Function
Menu button.
Click to set a desired room temperature.
Click to choose the operating mode (comfort, max boost, stand-by,
building protection or economy).
Show previous indicators.
Show next set of indicators.
I1
B1
I2
B2
I3
B3
I4
B4
B5
2
EN
B1
I3
B3
I2
I1
B2
2.2Temperaturesettingwindow
I5
I6
I7
5
2
Number Function
Window name.
Time.
Newly set desired room temperature (extracted air temperature).
Number Function
Back. Return to previous window.
Decrease set temperature.
Increase set temperature.
I1
B1
I2
B2
I3
B3
B1
B4
B5
B2
I1
EN
2.3Operationmodeselectionwindow
Number Function
Current operating mode.
Number Function
STANDBY – AHU is stopped.
BUILDING PROTECTION maintain minimal air movement. Tempera-
ture can be maintained depending on settings in Menu Set Points.
ECONOMY use decreased fan speed. Temperature can be maintained
depending on settings in Menu Set Points.
COMFORT - use normal fan speed. Temperature is maintained.
MAX BOOST Fans operate at maximum power (for a specied
period).
I1
B1
B2
B3
B4
B5
B3
6
B2
B12
B11
B15
B6
B1
B5
Number Function
Device status window.
Night cooling settings.
Period setting for max boost operating mode.
Review or modify set temperatures for all modes.
Filter maintenance status.
Heating season settings.
Set AHU control unit‘s date and time.
B1
B4
B2
B5
B3
B6
B7
B3
B4
B7
B10
2.4Menu
B8
2
EN
B9
B13
B14
7
B8
B9
B10
2
EN
Weekly scheduler: status and modication.
Show previous menu row.
Show next menu row.
Holiday scheduler: status and modication.
List of current faults.
User interface settings.
Adjuster menu.
Service menu.
B11
B12
B13
B14
B15
2.5Devicestatuswindow
I1
I2
I6
I5
I4
I3
I7
I8
Number Function
Supplied air temperature.
Exhausted air temperature.
Extracted air temperature.
Outside air temperature.
Current operating mode.
Max boost function state.
Speed of the air supplying fan.
Speed of the air extracting fan.
I1
I2
I5
I6
I3
I7
I4
I8
8
I1
I2
I6
I5
I9
I4
I3
I7
I8
2
EN
Number Function
Calculated required temperature of supply air.
Supplied air relative humidity.
CO2 quantity in supplied air.
Extracted air relative humidity.
CO2 quantity in extracted air.
Dierential pressure in supply duct.
Dierential pressure in extract duct.
Version of AHU’s control unit software.
I1
I2
I5
I6
I3
I7
I4
I8
I9
9
I1
B1
Number Function
Function state: green strip – on; gray – o.
Set temperature indication.
I1
F1
F2
2.6Nightcooling
Number Function
Minimum day temperature for a night cooling to be used.
Maximum night temperature for a night cooling to be used.
Desired room temperature at night.
F1
F2
F3
B3
F3
2
EN
I2
B2
I2
Number Function
Function on/o switch.
Buttons to increase value.
Buttons to decrease value.
B1
B2
B3
10
B1
B2
Number Function
Click to increase/decrease the „BOOST function time
B1 B2
Number Function
Max period of boost (in seconds).
F1
F1
2.7Fansboost
2
EN
I1
Number Function
Set temperature indication.
I1
11
Number Function
Room air temperature during building protection mode.
Room air temperature during economy mode.
Room air temperature during comfort mode.
F1
F2
F3
B2
F1 F3
F2
2.8Setpoints 2
EN
I2
B3
B4
I3 I1
B1
Number Function
Set temperatures indication.
State of temperature maintaining function during building protection
mode: green strip – on; gray strip – o.
State of temperature maintaining function during economy mode:
green strip – on; gray strip – o.
I1
I2
I3
Number Function
Buttons to increase value.
Buttons to decrease value.
On/o switch for temperature maintaining function during building
protection mode.
On/o switch for temperature maintaining function during economy
mode.
B1
B4
B2
B3
12
2
EN
B1
Number Function
Button to reset lter timer. Use only after lter replacement and at
Your own risk.
B1
Number Function
Days remaining till lter service.
I1
I1
2.9Filtertimer
13
EN
Number Function
Current setting indication.
I1
2
Number Function
Heating season mode:
By 3 days outside temperature average: heating season is selected
if average outside temperature exceeds the threshold;
By date: heating season starts and ends at specied days;
Heating: heating season is always active;
Cooling: heating season is never active;
Temperature threshold. Lower 3-day average of outside tempera-
ture will activate select heating season. Higher 3-day average of
outside temperature will cancel heating season.
Range: [0-30 °C]
F1
F2
F5
F1
F2
2.10Heatingseasonsettings
I1
14
2
EN
Number Function
Buttons to increase value.
Buttons to decrease value.
B1
B2
Number Function
Year.
Month.
Day.
Hour (24h format).
Minute.
F1
F4
F2
F5
F3
F1 F5
F2
B2
F4
F3
2.11Dateandtime
I1
B1
Number Function
Set date & time indication.
I1
15
EN
2
2.12Weeklyscheduler
Number Function
Selected event (light color).
On/o indicator for selected event (green strip – event is on).
New mode. The mode with a green strip will be set as current on oc-
currence of selected event.
Active weekdays (green strips); inactive weekdays (gray strips).
Event time (24h format).
I1
I5
I2
I3
I4
Number Function
Event scrolls (10 weekly events available).
Select event.
Event on/o switch.
Buttons to select mode. This mode will be activated on occurrence
of selected event.
Buttons to select active weekdays for selected event.
Dials to set event hour and minute.
B1
B2
B3
B4
I1
B5
B3
I2
B1
B2
I2
B1
B4
I3
I5
B6
B6
I3
B5
B6
16
2
EN
2.13Holidayscheduler
Number Function
Selected event (light color).
On/o indicator for selected event (green strip – event is on).
Selected mode. The mode with a green strip will be set as current on
occurrence of selected event.
Day and time to start selected event. Selected mode will be set as
current.
Day and time to end selected event. Previous mode will be reset as
current.
I1
I5
I2
I3
I4
Number Function
Event scrolls (10 holiday events available).
Select event.
Event on/o switch.
Buttons to select mode. This mode will be activated on occurrence
of selected event.
Dials to set event starting hour and minute.
Dials to set event ending and minute.
B1
B2
B3
B4
I1
B5
B1
B2
I2
B1
I5
B6
B6
B5
B6
I4
B5
I3
B4
17
EN
2
2.14Alarms
I1 B1
Number Function
Button to refresh the alarm list.
B1
Number Function
List of current active alarms.
I1
NOTE: All active alarms are also shown on a main window.
B2
B1
B5
B3
B4
2.15Settingsmenu
18
2
EN
Number Function
User interface language selection.
User interface theme selection.
Child protection lock settings.
Screen brightness and dimming settings.
Sound settings.
B1
B2
B3
B4
B5
B1
2.15.1Languageselection
Number Function
Buttons to select the language for user interface
B1
19
B1
2.15.2Themeselection
Number Function
Buttons to select the theme for user interface
B1
F1 F5
I1
F2 F4
F3
2.15.3Childprotectionlocksettings
Number Function
Current setting indication
I1
20
Number Function
Lock delay. Inactivity time to trigger the lock screen
Range: [OFF or 10-1200 s]
Unlock PIN code. Digit 1
Range: [0-9]
Unlock PIN code. Digit 2
Range: [0-9]
Unlock PIN code. Digit 3
Range: [0-9]
Unlock PIN code. Digit 4
Range: [0-9]
F1
F4
F2
F5
F3
Number Function
Current setting indication
I1
Number Function
Screen brightness for normal active mode
Range: [70-100 %]
Dimming level for dimmed mode
Range: [30-70 %]
F1
F2
2.15.4Screenbrightnessanddimmingsettings
F1 F5
F2 F4
F3
I1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Salda Ptouch User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI