Just Water Solutions Grey Power Gator Maxi 100 Installation and Operating Instructions

  • Hello! I am an AI chatbot trained to assist you with the Just Water Solutions Grey Power Gator Maxi 100 Installation and Operating Instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
WarrantyTermsandConditions
 YourGreyWaterGatorMaxi100iscoveredbya1yearreturntobasewarranty
 Ifanypartshouldfailotherthanthemainpititshouldbereturnedtothe
manufacturerforinspection.
 Warrantycommencesfromdateofpurchase.
 Unitmustbeinstalledbyalicensed
plumberorqualifiedinstaller.
 Incorrectoperationofunitisnotcoveredbywarranty.
 Labourandshippingforwarrantyclaimsarenotcoveredinthetermsofthisdocument
 Damagesincurredtopropertyorpersonsbyincorrectoperationorinstallationarenot
coveredbythiswarranty.
 Pleaseprovideproofof
purchasewithallwarrantyclaims.
 Ourtotalliabilityunderanywarrantyislimitedtoreplacingthedefectiveordamaged
goodsorrefundingthepurchaseprice.
 Weshallnotbedeemedliableforanylossbeyondourcontrol,orforanyindirector
consequentiallossofanykind
ACN 124 112 705

18RayleighAvenue
QUEENSCLIFFVictoria3225
Ph0352585193
Fax0352585193
Email:sales@justwatersolutions.com.au
www.greywatergator.com
InstallationandOperatingInstructions
Grey Water Gator Maxi 100
WMKT22111
GuidelinesfortheGREYWATERGATORMAXI100
YourJustWaterSolutionsGreyWaterGatorMaxi100™isspecificallydesignedfor
GreyWaterreusefromthelaundry,showerandbathwastewater.
 YourGreyWaterUnitmustbeinstalledbyalicensedplumberinaccordance
withregulationsAS/NZ3500.2.2.2003
 DonotconnecttoakitchensinkorToilet
asthisisclassedasBlackWaterand
isnotsuitableforthisunitorforreuse.
 OnlyconnecttosubsurfaceirrigationsuchasGreyWaterDriptubeorsullage
drainpipe.
WerecommendthatyoualsocheckwithyourlocalWaterAuthorityforapprovalof
thistypeof
SeasonalUseGreyWaterDiversiondevice.
Itismandatorythatthepowercircuittothisunitisprotectedbyaresidualcurrent
circuitbreakerandwehighlyrecommendasurgeprotectiondevicebefittedaswell.
YourGreyWaterUnitispreassembled.Pleasecheckthecontentsondeliveryas
in
transitdamagemayoccur.
INSTALLATION
Thisunitmustbeinstalledbyalicensedplumberandorserviceagent.Failureto
complywillvoidthewarranty
1.Yourplumber/installerwill installorlocateyourdedicatedGreyWater
Wastepipes.
2. Allowapprox350mmfromgroundleveltocutinpointInletpipe.
3.
Ifyourpipeworkisdeeperthanthis,optionalrisersof200mmareavailable.
4. Theoverflowpipemustbeconnectedtoasewerdischargepointsuchasa
gullytrap.
5. Excavateasuitableareaapprox800mmdeep1000mmlongand600mm
wide.
Allowenoughroomforconnectionto
pipework,electricalcableandconduit.
6. Makesurethebaseislevelusingfreeflowingpackingsand.Taketimetolevel
theunitandsetthecorrectheightsforthepipework.
7. Connectthepipeworkmakingsuretheinletandoverflowpipesarecorrectly
plumbed,inaccordancewith
AS3500.
8. Astheunithasaleadanda3pinplug,havealicensedelectricianinstalla
suitablepoweroutletadjacenttheunit.Makesuretheelectricalcableis
protectedatalltimes,andobserveelectricalregulationsinyourstate.
9. Connectthe25mmnonreturnvalveto
thedischargeoftheunit.
10. Connectthe25mmLilacpipeworktoyourirrigationsystem.
11. Afterallconnectionsarecompletedtotheregulationsyoucanbackfillthe
surroundingvoidwithsuitablematerial.(Freeflowingsandispreferred)Do
notbackfillwithsharporbrokenrocksthat
maydamageordistorttheunit.
12. Inspectthepittomakesureitisfreeofsandanddebristhatcoulddamage
thepump.
13. Youcantesttheoperationbyfillingwithwaterandobservingthewaterlevel,
SchematicDrawing
GreyWaterGatorMaxi100
1
Grey Water Gator Maxi 100 Pit
12
25mm Tank Inlet Fitting
2
Lilac Lid for Pit
13
Pump Controller Complete
3
Key for lid
13b
Magnetic Float switch
4
Blue Sub 15 High Head Pump
14
SS 6mm Allen Bolts
5
Filter set of 5
14a
Mounting Plate for Controller
6
Riser Pipe for pump
15
100mm Wallace seals
7
25mm Socket
16
100mm Bend M&F
8
25mm Threaded Pipe
17
100mm Pipe Piece x 155mm
9
25mm Swivel Elbow
18
100mm Diverter Valve
10
25mm Hex Nipple
19
Cable Gland
11
25mm Female Elbow
20
Watermark Approval Sticker
11. Donotpumptheresidualthroughtheirrigationsystem.
12. Onceeverythingiscleanedyoucannowreinstallthefilterstothetank
takingcaretofitthembackthesameastheywereremoved.
13. Youcanfilltheunitwithcleanwater tocheckoperationoffloatsand
use
thatcleanwatertoflushtheirrigationsystem.
14. Onceyouarehappytheunitisoperatingcorrectlyliftthehandleonthe
bypassvalvetoopentheflowintotheunit.
15. Refitthetopcoverandlockthelidwithyourkey.
16. Yourunitisnow
servicedandreadyforoperation.
Atthistimeitisgoodpracticetocheckoveryourirrigationsystem.
Turnonthedrainvalvesattheendofyourirrigationlinesandremoveany
sedimentthatmayhaveaccumulatedinthepipes.Checkforanyleaksor
damagetotheirrigationpipe
work.Repairasnecessary.
PumpSpecificationsGREYWA TERGATORMAXI100
YourGreyWaterGatorMaxi100unitisequippedwithaspeciallyselectedsingle
stagehighheadpumptohandlealmosteverydemandthataGreyWaterSystem
canhave.
Thispumpiscontrolledbyaninternalelectroniccontrolwhichstartsandstops
thepumpviaahighandlowmagnetic
floatswitch.
Italsoisprogrammedtooverridethefunctionofthehighfloatswitchatleastonce
ina24hourcycle.
Thiswillensuretherewillbelittleornoresidualwa terremainingintheunit.
Noelectricalconnectionsarerequiredintheunititselfotherthanan
external
powerpointneartheunit.
Pumpperformancetable:
 Maximumflowof140l/mat1metrehead.
 Ratedflowof80l/mat10metreshead.
 Maximumheadof14.5metres.
 Maximumcurrent750watts240volt.
 Warrantyis12monthsreplacement,onconditionthatitisreturned
to
 placeofpurchase,withproofofpurchase.
14. Makesurethediversionvalveisopen allowingGreyWatertoflowintotheunit.
15.Turningonafixtureinsidethehousethatisconnectedtothegreywater
pipeworkwillallowGreywatertoflowintotheunit.
16. Turnonthepowerbrieflyandcheck
thepumpisoperatingcorrectly.The
IrrigationSystemisnotconnectedatthisstage,thiswillallowtheunittobe
flushedout.
17. Installationoftheirrigationsystemcannowtakeplace
18. Yourunitisnowcommissionedandreadyforuse.
Additionalnotes
Ifamanifoldisusedontheirrigationsystem,atleastonevalvemustbeopenatall
timestopreventthepumpoperatingatclosedhead,thatisanoflowcondition.
Operationundertheseconditionswillvoidthewarranty.
Minimumpipesizefromtheunitis25mm.Using 25mm
Lilaclowdensitypolytubeor
25mmPVCpipeisrecommended.
Troubleshooting
Waterdoesnotflowintotheunit Checkthebypassvalve,makesurethehandleis
Intheraisedposition.
Theunitisfullbutthepumpisnotoperating
Checkifpumpisconnectedtothepower
sourceandcheckifpowerisavailable.
Thepumpshouldautomaticallystart
when
waterreachesthehigherfloatswitch. Ifpump
doesnotstart,cleanthetopfloatswitchand
testagain.
Thepumpcannotmaintaintherateof
Inflowingwater.
Checktoseeifirrigationsystemissized
correctly.
Atleast100MetersofTirandriptubeshouldbe
connectedto
theirrigationsystemasper
Irrigationinstructions.Theoutflowshouldbe
equaltotheinflow.Alsocheckforkinksor
Blockagesinpipeworkfromunit.
Thepumpsectionisemptywhilethewater
levelishighoninletside
Serviceandcleanthefiltermediatomaintain
flow.
GreyResidualisbuildinguparoundthe
Pump
Checkthefiltermedia,makesureitisseated
correctly andthattherearenovoidsunder
thefilterswhichwillcausebypassaround
them.
Offensiveodoursarereleasedfromyourunit Thoroughlycleantheunitandthefiltermedia.
Fillwith
freshwaterandpumpoutthrough
Irrigationsystem.
DISTRIBUTIONOFDIVERTEDGREYWATER
CurrentGovernmentRegulationsstatethatyoumustdisperseuntreatedgrey
waterviaaSubsurfaceirrigationsystem.
YoumustuseanapprovedirrigationsystemthatisspecificallydesignedforGrey
Water.
RecommendationsandGuidelinesforirrigationsystem:
ThearearequiredforyourIrrigationsystemdependsonthesoiltype.Thechartbelow
showsthesuggestedspacingrequiredbetweendripperlinesfordifferentsoiltypes,in
relationtothetotalarea.Minimumpipesizefromtheunitis25mmPVCorLow
Densitypolytube.
Makesurethemaximum
lengthofdriptubeis20metresfromthemainline
SoilTexture&StructureandDripperlineandrowspacing
Arearequiredperperson*inhousehold(m2)
12‐3‐4‐5‐6Persons
RecommendedFeatureSetbackdistance(metres)
Propertyboundaries,pedestrianpaths,driveways:1metre
Footingsofbuildings:1.5metre
Retainingwallfooting:1metre
Ingroundswimmingpoolsurrounds:1metre
Ingroundpotablewatertank:6metres
Boresintendedforhumanconsumption:30metres
Pleasealsorefertoyourlocalauthorityforregulationsastheserequirementscanvary
fromareatoarea.
WARNINGSANDPRECAUTIONSFORGREYWATERREUSE
 DonotconnectyourGreyWaterMaxitoyourkitchensink,dishwasherora
toiletsystem.ThisisallclassedasBlackwaterandmustgotosewerorseptic
waste.
 Whenwashingitemssuchassoilednappies,pleaseswitchyourdiversionvalve
todivertdirecttothesewerageorseptic
system.
SoilTypes Spacing 1 2 3 4 5 6
Gravel and Loams x.06m 30 60 90 120 150 180
Sandy Loams x 0.6m 30 60 90 120 150 180
Loams x 0.8m 40 80 120 160 200 240
Clay Loams x 0.9m 45 90 135 180 225 270
Light Clays x 1.0m 50 100 150 200 250 300
Medium to Heavy x 1.5m 75 150 225 300 375 450
 DonotdistributegreywaterfromyourGreyWaterMaxiunitviasprinklersor
allowforairbornedispersion.
 Onlyirrigatewhennecessaryandswitchunittodivertwhenraining.
 DonotletdivertedGreywatertorunofftoneig hbouringproperties.
 Donotleaveunitunattendedwhencarryingoutmaintenance
orwhenthe
coverisremoved.
 Incaseofextendedperiodsofnonoperationitisadvisedtocompletea
serviceandcleanoftheunittoavoidthepossibilityofdryingoutthesludge
onthefilters.
MAINTENANCEOFYOURGREYWATERUNIT
YourGreyWaterGatorMaxihasbeendesignedforminimummaintenance.
Duetothehighflowcapabilitiesofthe3dimensionalfiltersyoushouldonlyneedto
cleanyourunitafterapproximately40,000+litresofflowthrough.
Dependingofthenumberofoccupantsandtheamountofwaterflowingthrough
yourunitthecleaningcyclewillbebetween180360days.
Yourfiltersstillwillkeepworkingevenuptomaximumcapacity.
Someheavyloadsituationsmayrequireservicingyourunitonamorefrequentbasis.
Ifyouareconsideringnotusingyourunitforanextendedperiodof
timesuchasafew
months,pleasecarryoutafullserviceandcleanbeforedecommissioning.Thiswill
keepyourunitinoptimumconditionandeliminatebacteriabuildup.
Whenservicingandcleaningyourunitwerecommendthatyouwearprotective
rubberglovesandavoidskincontactasmuchaspossible.
1. Werecommendthataregisteredserviceagentcarryoutthemaintenanceto
thisunit.
2. Turnoffallpowertotheunit.
3. Removethelidwithyourkeyprovided.Bemindfulofanychildrenorpets
thatcouldaccidentallyfallintotheunitwhileservicing
4. Setthe
bypassvalvetotheclosedbypassposition.Thiswillprevent
Greywaterenteringtheunitwhileyouareworkingonit.
5. Youcannowaccessthefiltermedia.
6. Removerthefilterpadseitheroneatatimeortogether.
7. Takethefilterstoasuitableareaforcleaning.
8. Rinseofffiltersusingahandnozzlefromadomesticsupply.Washbothsides
untilreasonablyclean.NBthefiltersdonothavetobespotless.
9. DonotuseHighPressureCleaningequipmentonyourfiltermedia.
10. Atthistimerinsethepitandpumpandremove
theresidualwithaseparate
sumppump,orspongetheremainingresidualfromtheunit.
/