Phase Technologies ES3R, ES series, Essential Series Operation & Installation Manual

  • Hello! I am an AI chatbot trained to assist you with the Phase Technologies ES3R Operation & Installation Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Operation & Installation Manual
1/3 HP to 2 HP
120 V or 240 V
Single Phase
2-Wire & 3-Wire Motors
Essential Series
Variable Frequency Drive
ii | P a g e
2020 © Copyright.V1.4 All rights reserved. All contents are property of Phase Technologies, LLC.
No portion of this publication or its contents may be duplicated by any means, electronic or otherwise, without the
express written consent of Phase Technologies, LLC.
V1.4_06022020
231 E. Main Street North
Rapid City, SD 57701
Phone: 605-343-7934
Fax: 605-343-7943
Toll Free: 866-250-7934
www.phasetechnologies.com
Essential Series
Variable Frequency Drive
iii | P a g e
SAFETY MESSAGES AND WARNINGS
To ensure safe and reliable operation of the Essential Series drives, it is important to
carefully read this manual and to observe all warning labels attached to the unit before
installing. Please follow all instructions exactly and keep this manual with the unit for
quick and easy reference.
Definitions of Warning Signs and Symbols
CAUTION: Indicates a potentially hazardous situation that could result in injury or
damage to the product.
WARNING: Indicates a potentially hazardous situation that could result in serious
injury or death.
HIGH VOLTAGE: The voltage associated with the procedures referenced could
result in serious injury or death. Use caution and follow instructions carefully.
READ THESE WARNINGS BEFORE INSTALLING
OR OPERATING EQUIPMENT!
WARNING: Risk of electric shock. More than one disconnect switch may be
required to de-energize the equipment before servicing.
WARNING: Risk of electric shock. De-energize the unit by disconnecting all
incoming sources of power, then wait 10 minutes for internal charges to dissipate
before servicing the equipment.
HIGH VOLTAGE: This equipment is connected to line voltages that can create a
potentially hazardous situation. Electric shock could result in serious injury or death.
This device should be installed only by trained, licensed, and qualified personnel.
Follow instructions carefully and observe all warnings.
WARNING: This equipment should be installed and serviced by qualified
personnel familiar with the type of equipment and experienced in working with
dangerous voltages.
WARNING: Installation of this equipment must comply with the National Electrical
Code (NEC) and all applicable local codes. Failure to observe and comply with these
codes could result in risk of electric shock, fire, or damage to the equipment.
CAUTION: Circuit breakers, fuses, proper ground circuits, and other safety
equipment and their proper installation are not provided by Phase Technologies, LLC,
and are the responsibility of the end user.
iv | P a g e
CAUTION: Failure to maintain adequate clearance may lead to overheating of
the unit and cause damage or fire.
WARNING: Input power connections should be made by a qualified electrician
into circuit with adequate voltage and current carrying capacity for the model. Branch
circuit protection to the unit should be provided by appropriately sized fuses or a 2-
pole circuit breaker.
CAUTION: Use 600 V vinyl-sheathed wire or equivalent. The voltage drop of the
leads needs to be considered in determining wire size. Voltage drop is dependent on
wire length and gauge. Use only copper conductors.
CAUTION: Wires fastened to the terminal blocks shall be secured by tightening
the terminal screws to a torque value listed in Table 4.
CAUTION: The input wire gauge must be sized to accommodate the single-
phase input current, which will be significantly larger than the three-phase output
current to the load.
CAUTION: The maximum wire gauge for the input terminals is listed in Table 4.
CAUTION: Never allow bare wire to contact metal surfaces.
CAUTION: Never connect AC main power to the output terminals Red, Blk/Yel,
and Blk.
WARNING: Under certain conditions, the motor load may automatically restart
after a trip has stopped it. Make sure power to the drive has been disconnected before
approaching or servicing the equipment. Otherwise, serious injury may occur.
v | P a g e
TABLE OF CONTENTS
INTRODUCTION ..............................................................................................................................1
RATINGS .........................................................................................................................................2
INSTALLATION ...............................................................................................................................4
3.1 MOUNTING YOUR NEW ESSENTIAL SERIES VFD ...........................................................................4
3.2 PROPER VENTILATION .................................................................................................................4
3.3 SOURCE BRANCH CIRCUIT PROTECTION ......................................................................................4
3.4 GROUNDING ...............................................................................................................................5
3.5 WIRE SIZING...............................................................................................................................5
3.6 CONNECTING THE LOAD ..............................................................................................................5
3.7 CONNECTING TO FIELD WIRING TERMINALS ..................................................................................6
3.8 ROUTING POWER CABLES ...........................................................................................................6
3.9 CONTROL WIRING .......................................................................................................................7
USING THE KEYPAD AND DISPLAY ......................................................................................... 12
4.1 DISPLAY MODES ...................................................................................................................... 12
4.2 PASSWORD PROTECTING THE KEYPAD ...................................................................................... 12
4.3 KEYPAD DISPLAY MESSAGES ................................................................................................... 13
4.4 KEYPAD MAIN MENU ITEMS ...................................................................................................... 13
4.5 CHANGE PARAMETER VALUES .................................................................................................. 14
4.6 READ MEASURED VALUES ........................................................................................................ 15
4.7 READ TIMERS .......................................................................................................................... 17
4.8 CLEAR MEMORY ...................................................................................................................... 18
4.9 RESTART LOG ......................................................................................................................... 18
ADJUSTABLE PARAMETERS .................................................................................................... 20
5.1 CHANGING PARAMETER VALUES ............................................................................................... 20
5.2 RESTORE DEFAULT PARAMETER SETTINGS ............................................................................... 21
5.3 AUTO RESTARTS ..................................................................................................................... 22
5.4 ALL PARAMETERS LIST ............................................................................................................. 22
5.5 CHANGED PARAMETERS LIST ................................................................................................... 22
OPERATION ................................................................................................................................. 29
6.1 COMMISSIONING THE UNIT ........................................................................................................ 29
6.2 GROUND FAULT DETECTION ..................................................................................................... 29
6.3 DRY WELL/DEADHEAD PROTECTION & LOW PRODUCTION WELL CONTROL ................................. 31
6.4 MOTOR OVERLOAD PROTECTION .............................................................................................. 31
6.5 SYSTEM CONFIGURATION ......................................................................................................... 32
6.6 START-UP AND SHUT-DOWN RAMP TIMES ................................................................................ 32
CONSTANT PRESSURE SYSTEMS ........................................................................................... 33
7.1 CONTROL PRINCIPLES OF CONSTANT PRESSURE SYSTEMS ........................................................ 33
7.2 DIGITAL PRESSURE SWITCH ..................................................................................................... 35
7.3 DIGITAL CONSTANT PRESSURE SYSTEMS .................................................................................. 36
7.4 PERFECTPRESSURE SETUP ANALOG CONSTANT PRESSURE ................................................ 38
7.5 ANALOG CONSTANT PRESSURE SYSTEMS ................................................................................. 39
7.6 BASIC ANALOG CONSTANT PRESSURE INSTALLATION PROCEDURES: .......................................... 40
7.7 PRE-CHARGE MODE ................................................................................................................ 41
7.8 TANK SIZING ............................................................................................................................ 42
7.9 TROUBLESHOOTING CONSTANT PRESSURE SYSTEMS ................................................................ 42
TROUBLESHOOTING.................................................................................................................. 43
8.1 FAULT CODES.......................................................................................................................... 43
1 | P a g e
INTRODUCTION
Essential Series variable frequency drives (VFDs) are inverter based devices that provide
speed control for two- and three-wire, single-phase, AC motors. The drives offer advanced
motor control features through an intuitive, easy-to-use interface.
Essential Series Design
The diagrams in Figure 1 and Figure 2 illustrate the basic function of the Essential Series
drives for 2 & 3 wire single phase motors.
Figure 1 Essential Series 2-Wire Block Diagram
Figure 2 Essential Series 3-Wire Block Diagram
2 | P a g e
RATINGS
Product Specifications
Table 1 General Specifications
ES3R
HP
1/3 - 2
Motor Style
2-Wire or 3-Wire
Nominal Input Voltage
120/240 VAC
Input Voltage Range
96 132 VAC
190 265 VAC
Max. Input Current
24 A
Output Voltage
Equal to Input
Max. Output Current
13.1 A
Output Power
2 kW
Enclosure Type
NEMA 3R
Operating Temperature
1/3 HP to 1-1/2 HP -20 °C to 50 °C (-4 °F to 122 °F)
2 HP -20 °C to 40 °C (-4 °F to 104 °F)
Storage Temperature
-13 °F 165 °F
(-25 °C 74 °C)
Dimensions (H x W x D)*
12.25 in x 9.25 in x 4.68 in
Weight
7 lbs
* Detailed dimensions on next page.
Essential Series drives are capable of operating several types of systems, including:
Simple ON/OFF motor control from the keypad or remote switches
Digital constant pressure water systems
Analog constant pressure water systems
Analog speed potentiometer controlled systems
Pump Up or Pump Down water systems
The drive contains a wide range of settings and parameters allowing the user to easily
configure the drive for many applications. Detailed information on setting System
Configuration can be found in Section 6.5, on page 32.
3 | P a g e
Enclosure Dimensions
Figure 3 Essential Series Enclosure Dimensions
4 | P a g e
INSTALLATION
3.1 Mounting Your New Essential Series VFD
Proper installation of the unit is important to the performance and normal operating life of
the unit. It should be installed in a location free from:
Corrosive gases or liquids
Excessive vibration
Airborne metallic particles
Mount the unit to a solid, non-flammable surface capable of bearing the weight using the
mounting bracket provided on the unit.
3.2 Proper Ventilation
In order to maintain air circulation for adequate cooling, minimum clearance around the unit
must be maintained. Allow six inches on each side and top, and 18 inches below.
Ensure air intake and exhaust openings are not obstructed. If the unit is mounted in a small
room, cabinet, or building, ensure there is adequate ventilation to provide sufficient cooling
for the unit.
3.3 Source Branch Circuit Protection
Branch circuit protection must be installed in the circuit sourcing the drive. See Table 2 for
recommended circuit breaker sizing, which is based on 125% of the rated input current.
Fuses may be used for circuit protection; consult local electrical code for proper sizing.
Installation of a disconnection means within sight of the drive is recommended.
Table 2 Fuse/Breaker Recommendations
Motor HP
Input Current
Fuse/Breaker
1/3
8 A
10 A
1/2
12 A
15 A
1
24 A
30 A
1/2
6 A
10 A
3/4
9 A
15 A
1
12 A
15 A
1 1/2
18 A
25 A
2
24 A
30 A
5 | P a g e
3.4 Grounding
Properly ground the drive according to local electrical code.
Connect the ground lug to the branch circuit or service ground conductor.
Table 3 Ground Wire Specifications
Model
Recommended
Ground Wire Size
ES3R
10 AWG
3.5 Wire Sizing
Wire size must comply with all NEC and local electrical code requirements. The voltage
drop from the supply to the drive should be limited to 3% to ensure proper starting and
operation of motor loads. Increase the wire gauge to provide adequate voltage to the load.
Ensure the wire gauge is suitable for the terminal block, see Table 4.
Use the following formula to calculate line voltage drop.






See Table 2 for guidelines on fuse and breaker sizes. Installations must comply with all
NEC and local electrical code requirements.
3.6 Connecting the Load
Overload, ground fault, and short circuit protection functions are built into the drive to
protect the load side conductors and motor, as well as the drive itself, from faults.
Table 4 Input and Output Power Terminal Specifications
Power Terminals: Allowed Wire
Range and Minimum Torque
Wire Size
Torque
14 6 AWG
10.5 in-lb
6 | P a g e
3.7 Connecting to Field Wiring Terminals
To open the door, unscrew the fastener on the bottom right corner. The door will slide down
onto the hinge and then rotate open to gain access to the wiring panel. For 2-wire motor
and 3-wire motor connections, see Table 5 below.
a. Field Terminal Overview
b. Field Terminal Close-Up
Figure 4 ES Field Wiring Terminals
Table 5 Power Terminal Descriptions
Terminal Name
Description
L1, L2
Input power terminals
BLK, BLK/YEL
2-wire output power terminals
RED, BLK/YEL, BLK
3-wire output power terminals
RED
Auxiliary/Start/Run Winding
BLK/YEL
Motor Winding Common
BLK
Main Winding
GND
Earth ground
3.8 Routing Power Cables
Note: Continuous metal conduit should be used for all power cables to reduce radiated
electromagnetic interference (EMI). The conduit must be securely connected to the drive
enclosure drive and the motor case for proper grounding. Consult local electrical code for
proper grounding methods.
Route power cables through the supplied openings in the bottom of the enclosure. Use
appropriate conduit or strain relief devices. Conduit hubs should be IMC or rigid steel
conduit and should be UL listed. Conduit hub locations are shown in Figure 5.
Important Note: Remove all metal shavings after cutting new openings.
7 | P a g e
Figure 5 Essential Series Conduit Locations
3.9 Control Wiring
WARNING! When the drive is turned OFF using a control switch connected
to the AUX terminals, dangerous voltage may still be present on the input lines and
elsewhere inside the enclosure.
The output of the drive can be controlled with a switch connected between the AUX1 and
COM terminals and/or the AUX2 and COM terminals. When AUX1 to COM and AUX2 to
COM are closed, the drive enters run mode after a delay of approximately three seconds. If
AUX1 and AUX2 are closed when the unit is powered on, the output is energized after a
delay of approximately 16 seconds. When AUX1 or AUX2 to COM are open, the drive is
stopped.
To use a 0-5 VDC transducer or a 4-20 mA analog transducer, the optional analog I/O
board is required. Contact Phase Technologies if this upgrade is needed. Figure 6 shows
control terminal locations.
a. AUX1, AUX2, and COM next to field
wiring terminals
b. Analog control terminals, located on
optional analog I/O board.
Figure 6 Control Terminal Locations
Table 6 describes the control wiring terminals. See connection diagrams in Figure 7,
Figure 8, and Figure 9.
8 | P a g e
Table 6 - Control Terminal Ratings and Descriptions
Terminal
Description
Rating
Comments
AUX1
Auxiliary Input 1
Dry contact
type
Pullup
Voltage
< 5 volts,
galvanically
isolated
Digital input. Commonly used for
RUN/STOP command. Controlled by
parameters AUX1 SELECT and
AUX2 SELECT.
AUX2
Auxiliary Input 2
COM
Common
Common for AUX terminals.
The following terminals are only available with upgraded I/O board.
5VO
0-5 VDC Output
0-5 VDC
5 VDC supply to provide power to a
potentiometer. Refer to Table 14 for
details. See Figure 9 for connection
diagram.
VIN
0-5 VDC Input
Analog input for motor speed control.
Speed is relative to scale of signal
from 0 Hz to Max Frequency, set in
Adjustable Parameter menu (default
60 Hz). Connect the wiper terminal of
a potentiometer to this terminal as
shown in Figure 9.
COM
Common
Common for 0-5 VDC.
I+
4-20 mA positive
4-20 mA
Analog transducer connection for
analog constant pressure or
proportional motor speed control from
a current source. Refer to Table 14
for details. See Figure 8 for a
connection diagram.
I-
4-20 mA negative
4-20 mA
CAUTION! Electrostatic discharge (ESD) can damage electronic components.
Discharge ESD prior to touching the board or to making connections. To discharge ESD,
touch your hand to unpainted metal on the enclosure.
9 | P a g e
Digital Pressure Switch (standard with Essential Series drives)
Follow these steps to connect a digital pressure switch:
1. Using the keypad, set the value of parameter SYSTEM CONFIG to 1. Refer to Table
14, Interface Parameters, or Section 6.5, System Configuration, for details.
2. Connect either wire of digital pressure switch to AUX1
3. Connect second wire of digital pressure switch to COM
The following steps detail connecting an overpressure switch (not provided by Phase
Technologies).
4. Connect one wire of overpressure switch to AUX2
5. Connect second wire of overpressure switch to COM
6. If using overpressure switch, change AUX2 SELECT to 0
CAUTION: By default, AUX1 is programmed such that OPEN=STOP, CLOSED=RUN
and AUX2 is programmed such that OPEN=RUN, CLOSED=STOP. When SYSTEM
CONFIG = 2 (Analog CP), AUX1 and AUX2 are programmed such that OPEN=RUN,
CLOSED=STOP. See parameters AUX1 SELECT and AUX2 SELECT to change this
setting.
Figure 7 Connection Diagram for Digital Pressure Switch. Digital pressure switch
connected to AUX1 and COM, overpressure switch connected to AUX2 and COM.
See Section 7.2 for information on changing the pressure set point of the digital pressure
switch.
Digital
Pressure
Switch
Overpressure
Switch
10 | P a g e
4-20 mA Analog Transducer (Available with optional analog I/O board)
Follow these steps to connect a 4-20 mA transducer:
1. Using the keypad, set the value of parameter SYSTEM CONFIG to 2. See Section
6.5, System Configuration, and Section 7, Constant Pressure Systems, for more
information.
2. Connect the positive lead of the transducer to terminal I_1+.
3. Connect the negative lead of the transducer to terminal I_1-.
CAUTION: If the I+ and I- sensor cable is short circuited or if the sensor fails, the
drive will stop and indicate a fault, SENSOR CONNECTION FAIL. Disconnect input power
to the drive and fix the short circuit or replace the sensor.
Figure 8 Connection Diagram for 4-20 mA Analog Transducer
Control Tip: Turbulence near pressure switch or transducer can result in poor
pressure control. For best results, pressure switches and transducers should be placed at
least 6 inches away from pressure tanks, check valves, and pipe elbows.
+
-
4-20mA
Transducer
11 | P a g e
0-5 VDC Potentiometer (Available with optional analog I/O board)
Follow these steps to connect a 0-5 VDC potentiometer:
1. Using the keypad, set the value of parameter SYSTEM CONFIG to 3. Refer to Table
14, Interface Parameters, or Section 6.5, System Configuration, for details.
2. Connect the negative lead of the potentiometer to control terminal COM
3. Connect the wiper terminal of the potentiometer to the V IN terminal
4. Connect the positive lead of the potentiometer to the 5 VO terminal.
CAUTION: By default, AUX1 is programmed such that OPEN=STOP, CLOSED=RUN
and AUX2 is programmed such that OPEN=RUN, CLOSED=STOP. When SYSTEM
CONFIG = 2 (Analog CP), AUX1 and AUX2 are programmed such that OPEN=RUN,
CLOSED=STOP. See parameters AUX1 SELECT and AUX2 SELECT to change this
setting.
CAUTION: The resistance value of the transducer must be from 5k Ohms to 2k
Ohms. Resistance below 5k Ohms will produce a high current in the circuit and may
damage components in the circuit.
Figure 9 Connection Diagram for 0-5 VDC Potentiometer
12 | P a g e
USING THE KEYPAD AND DISPLAY
Essential Series drives are capable of many advanced, easy-to-use features that allow the
user to protect the motor load from damage, monitor load conditions, log motor run time,
troubleshoot the system, and more. The keypad is easy to use and understand, with 32
character text messages and an intuitive interface specifically tailored for pumping
applications.
Figure 10 Graphic Display and Keypad
4.1 Display Modes
After two minutes of keypad inactivity, the display will revert to the default display mode.
Information on the display will vary based on the operating mode of the drive. When
operating in AUTO mode with the factory default System Configuration 0, the display will
indicate output kilowatts (kW), output amps (A), output frequency (Hz) and the status of the
AUX1 and AUX2 inputs.
4.2 Password Protecting the Keypad
The keypad can be set up with a password to prevent unauthorized changes in adjustable
parameters. The parameter PASSWORD SETUP (Table 14, Interface Parameters) is used
to protect the keypad. When this parameter has a value of zero the keypad is not protected.
To password protect the keypad, enter a password consisting of a number between 1 and
99 as the parameter value. Contact customer service at 605-343-7934 if you lose or forget
the password.
ENTER key selects
menu items and
saves parameter
values after scrolling
to desired setting
RUN and
STOP keys to
control motor in
manual mode
UP and
DOWN keys
scroll through
menu items
HOME key
toggles Main
Menu and
Home screen
MANUAL and
RUN/AUTO
selects OFF,
MANUAL, or
AUTO mode
BACK key
returns to
previous
screen
13 | P a g e
4.3 Keypad Display Messages
Essential Series VFDs have several operating modes: AUTO, MANUAL, and OFF. The
factory default operating mode is OFF. Operating Modes are detailed in Table 7.
Table 7 Operating Modes
MODE
DESCRIPTION
AUTO
In AUTO mode, the motor load will automatically run if both AUX1 and AUX2
remote switches are closed. Open AUX1 or AUX2 to stop the motor or push
STOP/OFF key.
The parameter, ENABLE RESTARTS, must be set to YES to allow automatic
re-starts. See Table 15, Auto-Restart Parameters for details.
CAUTION: By default, AUX1 is programmed such that OPEN=STOP,
CLOSED=RUN and AUX2 is programmed such that OPEN=RUN,
CLOSED=STOP. When SYSTEM CONFIG = 2 (Analog CP), AUX1 and
AUX2 are programmed such that OPEN=RUN, CLOSED=STOP. See
parameters AUX1 SELECT and AUX2 SELECT to change this setting.
MANUAL
Activate MANUAL mode by pushing the MANUAL key until MANUAL appears
on top left of the display. In MANUAL mode the motor load is controlled by
using the RUN and STOP keys, which will override the AUX1 and AUX2
remote switches.
Manual control of the drive through the keypad can be disabled through the
parameter DISABLE MANUAL. See Table 14, Interface Parameters, for
details.
CAUTION: Operating the system in MANUAL mode on the keypad
overrides signals from the pressures switches. Operating the system in this
mode may lead to dangerous pressures in closed plumbing systems.
CAUTION: If the 4-20 mA or 0-5 VDC control terminals are short
circuited, power will be lost to the keypad. If the drive is in MANUAL RUN
mode the drive will not respond to a STOP command on the keypad.
Disconnect input power to the drive to stop the motor and then fix the short
circuit.
OFF
The factory default operating mode is OFF. The adjustable parameter,
ENABLE RESTARTS, must be set to 1 to allow automatic re-starts. To exit
AUTO mode, press the STOP/OFF key until OFF appears on top left of the
display. If the motor is running, it will stop. To restart the motor, revert to either
AUTO mode or MANUAL mode. Certain faults can also be cleared by
pressing the up and down arrow keys at the same time and holding for one
second.
4.4 Keypad Main Menu Items
The HOME key toggles between the Home screen (operating status screen) and the Main
Menu items. Use the UP and DOWN arrows to scroll through the Main Menu items. Press
ENTER to view or edit a Main Menu item.
Figure 11 contains a brief description of Main Menu items, followed by in-depth instructions
on the use and function of each Main Menu item.
14 | P a g e
Figure 11 - Navigating Main Menu Items
Table 8 Main Menu Items
DISPLAY MESSAGE
DESCRIPTION
CHANGE
PARAMETER VALUES
Allows the user to set values for functions such as motor
overload settings, dry well condition, time to restart after
a fault, etc.
READ MEASURED
VALUES
Displays measured values such as output current, input
voltage, load power factor, etc.
READ TIMERS
Records motor run time and drive on time.
RESTART LOG
A re-settable fault log that records the number of times a
particular fault has occurred. The number of faults
counted in this log can be cleared through the CLEAR
MEMORY menu.
CLEAR MEMORY
This function clears the Restart Log and Timers. All fault
counters in the Restart Log will be reset to zero. If any
number of automatic restarts have been allowed through
parameters in the Auto Restart Parameters (Table 15),
the counter on these faults will be set to zero.
4.5 Change Parameter Values
The Main Menu item, CHANGE PARAMETER VALUES, leads to several sub-menus that
contain adjustable operating parameters. These parameters provide basic functions such
as motor overload protection and advanced features that allow you to customize operation
of the drive to fit your application.
The following Section 5, Adjustable Parameters, contains a complete list of the parameters
along with a description of their function and instructions on setting them.
CHANGE
PARAMETER
VALUES
MANUAL
OFF
AUX1
8HP 12A
READ
MEASURED
VALUES
READ
TIMERS
FAULT
LOG
Press HOME, then use UP and DOWN arrow
keys to scroll through Main Menu items
Press ENTER key to
view or edit a Main
Menu item
Press BACK key to
escape back to the
Main Menu items
15 | P a g e
Figure 12 Change Parameter values
4.6 Read Measured Values
The display can provide a variety of measured values related to the performance of the
drive and its load, such as currents, horsepower, and power factor. To read measured
values:
1. Press the HOME key to access Main Menu items, and then scroll with arrow keys
until READ MEASURED VALUES appears on the display.
2. Press ENTER to access this menu item.
3. Use the up and down arrow keys to scroll through the various values that you
wish to read.
Programming Tip
Press the HOME key at any time to return Home screen (operating status screen).
READ
MEASURED
VALUES
CHANGE
PARAMETER
VALUES
Press either arrow
key to scroll list of
Main Menu items.
Press ENTER
key to view sub-
menus of
Adjustable
Parameters.
OPERATING
PARAMETERS
AUTO RESTART
PARAMETERS
Scroll through
sub-menus
with arrow
keys
Press BACK key to go
back to Main Menu Items
ENABLE
RESTARTS
Press ENTER
key to access a
parameter list in
a sub-menu.
Scroll through
list of
parameters
with arrow
To change a parameter value,
scroll to the parameter, press
ENTER, and then use the
arrow keys to change the
value. Press ENTER to save
the change, or BACK to
escape without saving the
change.
ENABLE
RESTARTS
YES
/