KUSSMAUL 091-45TD User manual

Type
User manual

This manual is also suitable for

INSTRUCTION MANUAL
UV-OV RELAY
PRECISE - PROGRAMMABLE VOLTAGE DETECTOR
MODEL #091-45TD
3 YEAR WARRANTY
A BATTERY SYSTEM VOLTAGE
MONITOR WHICH DETECTS OVERVOLTAGE
AND UNDERVOLTAGE CONDITIONS AND
PROVIDES A TIME DELAY FOR THE OUTPUT
KUSSMAUL ELECTRONICS CO., INC.
170 CHERRY AVE., WEST SAYVILLE, N.Y. 11796
BOOK# 09145004
OCTOBER 13, 2000
TEL: in NY 631-567-0314 TOLL FREE: 800-346-0857 FAX: 631-567-5826
Switch #1 Switch #2 Switch #3 Trips Below:
OFF OFF OFF 13.01 Volts
OFF OFF ON 12.76 Volts
OFF ON OFF 12.52 Volts
OFF ON ON 12.29 Volts
ON OFF OFF 12.07 Volts
ON OFF ON 11.85 Volts
ON ON OFF 11.64 Volts
ON ON ON 11.44 Volts
INTRODUCTION
The UV-OV Relay is a device which continuously monitors the voltage of a battery system and
detects overvoltage and undervoltage conditions. A set of contacts are provided for each of
these conditions. The values of the overvoltage and undervoltage detection points are easily
and independently programmable by accessible “DIP” switches behind the removable cover.
An adjustable time delay of 8 to 150 seconds is provided.
INSTALLATION
Figure 1 is a view of the programming switches with the snap-on top cover removed. Refer to
this figure when programming the unit.
Programming Switches
FIGURE 1
TEST/RUN
Switch
TEST
Undervoltage
Programming
Switches
Overvoltage
Programming
Switches
RUN
(a) Select the desired undervoltage trip point from the column to the far right in table 1 below.
(b) Set switches #1, #2 and #3 to the settings shown in table 1 corresponding to the
selected trip point in step (a).
TABLE 1 Undervoltage Programming
Switch #4 Switch #5 Switch #6 Trips Below:
O F F O F F O F F 15.06 Volts
O F F O F F O N 14.84 Volts
O F F O N O F F 14.63 Volts
O F F O N O N 14.42 Volts
O N O F F O F F 14.22 Volts
O N O F F O N 14.03 Volts
O N O N O F F 13.84 Volts
O N O N O N 13.66 Volts
(c) Select the desired overvoltage trip point from the column to the far right in table 2 below
(d) Set switches #4, #5, and #6 to the settings below in table 2 corresponding to the
selected trip point in step (c).
(e) Set switch #7 to “RUN” operation if it is not already in that position. This allows
approximately 1 second of time delay for the trip points to act, and filters alternator ripple.
(f) For mechanical installation, refer to figure 3 for the hole pattern and sizes.
(g) For electrical installation, refer to figure 2 which shows the connections to various
parts of the vehicle. The alarm contacts can be connected to alarm lamps via ground
or +12 volts. Figure 4 shows a scheme for a ground hookup while Figure 5 shows
a hookup for +12 volts.
TABLE 2 Overvoltage Programming
FIGURE 2 Electrical Installation
TIME DELAY ADJUSTMENT
1. Remove cover
2. Locate time adjust trimmer
3. Adjust to desired time delay, note that trimmer is factory set for 150 seconds
MAXIMUM COUNTERCLOCKWISE = 8 sec..
MID POSITION = 80 sec.
MAXIMUM CLOCKWISE = 150 sec..
FIGURE 3
A5
C1
R1
A4
R2
R3
R17
R6
R16
C3 C2
A2
A7
R9
C4
R8
Q4
U1
++
+
A1
CR2
CR1
U3
7808
R15
Q3
DS3
Q2
A6
U2
Q1
DS1
R7
VR1
CR3
CR5
S1
K1
K2 109
87654
312
J1
DS2
R10
R12
U4
R13
R11
R14
CR7
CR6
CR4
KUSSMAUL
ELECTRONI CS CO I NC
TD ADJ.
B091-45-004
HI
LO
NORMAL
FIGURE 4 Alarm Lamp Connections Via Ground
FIGURE 5 Alarm Lamp Connections Via +12 Volts
SPECIFICATION & OUTLINE
1.50
3/16" DIA.
4.25
2.00
3.50
3.75
INSTALLATION RECORD & WARRANTY
Date Installed
Installed By
Vehicle Identification
Vehicle Owner
WARRANTY
All products of Kussmaul Electronics Company Inc. are warranted to be
free of defects of material or workmanship. Liability is limited to repairing or
replacing at our factory, without charge, any material or defects which
become apparent in normal use within 3 years from the date the equipment
was shipped. Equipment is to be returned, shipping charges prepaid and will
be returned, after repair, shipping charges paid.
Kussmaul Electronics Company, Inc. shall have no liability for damages
of any kind to associated equipment arising from the installation and /or use
of the Kussmaul Electronics Company, Inc. products. The purchaser, by the
acceptance of the equipment, assumes all liability for any damages which
may result from its installation, use or misuse, by the purchaser, his or its
employees or others.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

KUSSMAUL 091-45TD User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI