Pelco Sarix SNMP Operations Manual

  • Hello! I am an AI chatbot trained to assist you with the Pelco Sarix SNMP Operations Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Introduction
This document defines the OID tree structure for Pelco Sarix IP cameras with 1.6 firmware or later.
NOTE: Refer to the Pelco web site at www.pelco.com for the most up-to-date MIB information.
VALIDITY
The MIBs described in this document apply to the following Pelco products:
Sarix IX, ID, IE and IM series
NET 540x Encoders
Spectra IV IP h.264
Esprit IP
Exsite IP
•Spectra HD
Sarix TI
Esprit TI
Pelco Camera MIB
Figure 1. Pelco Camera MIB
Table A. Pelco Camera OID Names and Descriptions
OID Name OID Description
Pelco-Camera-MIB .1.3.6.1.4.1.25066.1 The top level Pelco camera MIB
Pelco-Camera-Diagnostic-MIB .1.3.6.1.4.1.25066.1.1 MIB for camera diagnostic information
Pelco-Camera-Accessory-MIB .1.3.6.1.4.1.25066.1.3 MIB for camera accessory information
Pelco-Camera-MIB
.1.3.6.1.4.1.25066.1
Pelco-Camera-Diagnostic-MIB
.1.3.6.1.4.1.25066.1.1
Pelco-Camera-Accessory-MIB
.1.3.6.1.4.1.25066.1.3
PROGRAMMING
Sarix SNMP
C5648M (2-13-2013)
2 C5648M (2/13)
PELCO CAMERA DIAGNOSTIC MIB
Figure 2. Pelco Camera Diagnostic MIB
Table B. Pelco Camera Diagnostic OID Names and Descriptions
OID Name OID Description Return Value Accessibility
Model Number .1.3.6.1.4.1.25066.1.1.1 Model number for camera String Read-Only
Model Name .1.3.6.1.4.1.25066.1.1.2 Model name of the camera String Read-Only
Serial Number .1.3.6.1.4.1.25066.1.1.3 Serial number of the camera String Read-Only
Firmware Version .1.3.6.1.4.1.25066.1.1.4 Firmware version of the camera String Read-Only
Software Version .1.3.6.1.4.1.25066.1.1.5 Software version of the camera String Read-Only
Hardware Version .1.3.6.1.4.1.25066.1.1.6 Hardware version of the camera String Read-Only
System Temperature .1.3.6.1.4.1.25066.1.1.7 Temperature of the camera near the lens;
if a trap is configured, the camera will send an SNMP trap
message to the NMS when a temperature threshold is met
Unsigned32 Read-Only
Power Status .1.3.6.1.4.1.25066.1.1.8 Displays power status of the camera: Good (0) or Bad (1);
will also send a fault if power is below the threshold
Integer (0 or 1) Read-Only
Voltage Status .1.3.6.1.4.1.25066.1.1.9 Displays voltage status of camera: Good (0) or Bad (1);
will also send a fault if voltage is below the threshold
Integer (0 or 1) Read-Only
Reboot Device .1.3.6.1.4.1.25066.1.1.100 Set this OID to “1” to initiate a camera reboot;
this OID reverts back to “0” after the reboot is complete
Integer (0 or 1) Read/Write
Pelco-Camera-Diagnostic-MIB
.1.3.6.1.4.1.25066.1.1
ModelNumber
.1.3.6.1.4.1.25066.1.1.1
ModelName
.1.3.6.1.4.1.25066.1.1.2
RebootDevice
.1.3.6.1.4.1.25066.1.1.100
Voltage
.1.3.6.1.4.1.25066.1.1.9
Power
.1.3.6.1.4.1.25066.1.1.8
SystemTemperature
.1.3.6.1.4.1.25066.1.1.7
HardwareVersion
.1.3.6.1.4.1.25066.1.1.6
SoftwareVersion
.1.3.6.1.4.1.25066.1.1.5
FirmwareVersion
.1.3.6.1.4.1.25066.1.1.4
SerialNumber
.1.3.6.1.4.1.25066.1.1.3
C5648M (2/13) 3
PELCO CAMERA ACCESSORY MIB
Figure 3. Pelco Camera Accessory MIB
1
Each Return Value in the Alarm Table has the following format: Alarm Bank Name (string), Alarm Index (integer), Alarm State (integer).
2
Each Return Value in the Relay Table has the following format: Relay Bank Name (string), Relay Index (integer), Relay State (integer).
Table C. Pelco Camera Accessory OID Names and Descriptions
OID Name OID Description Return Value Accessibility
Alarm Table .1.3.6.1.4.1.25066.1.3.1 Table storing the state of each alarm on the camera Table
1
Read-Only
Relay Table .1.3.6.1.4.1.25066.1.3.2 Table storing the state of each relay on the camera Table
2
Read-Only
Pelco-Camera-Accessory-MIB
.1.3.6.1.4.1.25066.1.3
Alarm
.1.3.6.1.4.1.25066.1.3.1
Relay
.1.3.6.1.4.1.25066.1.3.2
Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pelco, Inc. or its affiliates. © Copyright 2013, Pelco, Inc.
ONVIF and the ONVIF logo are trademarks of ONVIF Inc. All other product names and services are the property of their respective companies. All rights reserved.
Product specifications and availability are subject to change without notice.
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.
Pelco by Schneider Electric 3500 Pelco Way Clovis, California 93612-5699 United States
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150
International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120
www.pelco.com www.pelco.com/community
/