7
Additional requirements for ABB motors of types other than M2_, M3_, M4_,
HX_ and AM_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Additional requirements for the braking applications . . . . . . . . . . . . . . . . . . . . . . . 69
Additional requirements for ABB high-output and IP23 motors . . . . . . . . . . . . . . . 69
Additional requirements for non-ABB high-output and IP23 motors . . . . . . . . . . . 70
Additional data for calculating the rise time and the peak line-to-line voltage . . . . 71
Additional note for sine filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Selecting the power cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
General rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Typical power cable sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Alternative power cable types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Recommended power cable types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Power cable types for limited use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Not allowed power cable types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Motor cable shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Additional US requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Armored cable / shielded power cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Planning the braking system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Selecting the control cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Shielding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Signals in separate cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Signals allowed to be run in the same cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Relay cable type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Control panel cable length and type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Routing the cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Separate control cable ducts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Continuous motor cable shield or enclosure for equipment on the motor cable . . . . . 77
Implementing thermal overload and short-circuit protection . . . . . . . . . . . . . . . . . . . . . . 78
Protecting the drive and input power cable in short-circuits . . . . . . . . . . . . . . . . . . . . 78
Protecting the motor and motor cable in short-circuits . . . . . . . . . . . . . . . . . . . . . . . . 78
Protecting the drive and the input power and motor cables against thermal
overload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Protecting the motor against thermal overload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Protecting the drive against ground faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Residual current device compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Implementing the emergency stop function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Implementing the Safe torque off function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Implementing Prevention of unexpected start-up function (option +Q957) . . . . . . . . . . . 80
Implementing ATEX-certified Safe disconnection function (option +Q971) . . . . . . . . . . 80
Implementing the functions provided with the safety functions module FSO-11
(option +Q973) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Implementing the Power-loss ride-through function . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Units with main contactor (option +F250) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Supplying power for the auxiliary circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Using power factor compensation capacitors with the drive . . . . . . . . . . . . . . . . . . . . . . 81
Implementing a safety switch between the drive and the motor . . . . . . . . . . . . . . . . . . . 82
Using a contactor between the drive and the motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Implementing a bypass connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Example bypass connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Switching the motor power supply from drive to direct-on-line . . . . . . . . . . . . . . . 84
Switching the motor power supply from direct-on-line to drive . . . . . . . . . . . . . . . 84
Protecting the contacts of relay outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84