  • Hello! I am an AI chatbot trained to assist you with the LP SmartSide 2902075 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
G
• TherearenoNationalStandardsforwoodcompositesubstratetrim.
• LPSmartSidetrimandfasciacanbeapplieddirectlyovermaterials
suchassiding,ornaileddirectlytostructuralmembersupto
24in.O.C.
•
Allfasciamustbesupportedwithsolidwoodsubfascia. Strand based
fascia may be installed without subfascia if it is 6 in. 540 series or
larger.
• TRIMMUSTNOTBEINDIRECTCONTACTWITHMASONRY,
CONCRETE,BRICK,STONE,STUCCOORMORTAR.
• Minimum6in.clearancemustbemaintainedbetweentrim
andfinishgrade.
• Trimappliedadjacenttoporches,patios,walks,etc.musthavea
clearanceofatleast1in.aboveanysurfacewherewatermightcollect.
Thesurfacemustbeslopedorotherwisedesignedtoprovideproper
drainagesothetrimisatnotimedirectlyexposedtostandingwater.
• Trimandfasciaarenotdesignedforsiding;orstructuralapplications
andshouldnotbeusedasastructuralmemberinconstructionsuch
asatrellis,railingorfencing.
• Anon-corrosivedrip-edgeordrip-capmustbeappliedatbottomedge
ofroofingwhereitmeetsthefascia.
• Trimandfasciamustnotbeappliedtogreenorcrookedstructural
framingmembers.Donotapplytrimand/orfasciaoverrainsoakedor
buckledsheathingmaterials.
• DO NOT USE STAPLES
M
• Moisturecontrolandwatervaporcontrolarecriticalelements
ofproperhousingdesign.Checkyourlocalbuildingcodesfor
applicationproceduresforhandlingmoistureandwatervapor
inyourarea.
• Followallapplicablebuildingcodespecificationsrelatingto
preventionofmoistureintrusionintothewallassembly.LP
SmartSidetrimandfasciaisawoodproduct,and,aswithallwood
products,mustbekeptfreefromconstantsourcesofmoisture.
Lackofproperventilation;exposuretorepetitivesourcesofwater
suchassprinklers,condensation,inadequateflashing;improper
sealing;orfailuretofollowcommonbuildingpracticesthatprevent
moistureintrusionintothewall-system;maycausedamage,and
willvoidthewarranty.
C
• Forthecleanestcutandlongerbladelife,afine-toothcarbide
tippedbladeisrecommended.
• Trimandfasciaaremanufacturedwithaspecialedge
coatingwhichreducesmoisture-relatedissues.Avoidripping
androutingthetrimandfascia,asitwillleavetheedges
unprotected.Ifthetrimorfasciamaterialsmustberippedyou
must,takespecialcaretoprime,paintandsealallexposed
woodfiberasdescribedinthefinishingsection.
 
TRIM AND FASCIA
190, 440, 540, 2000 SERIES
S
• Storeoffthegroundonaflatsurface,underarooforseparate
waterproofcovering.
• Keeptrimandfasciacleananddry.Inspectpriortoapplication.
G, S  J
• Sealallgapswithahigh-quality,non-hardening,paintable
sealant.Followthesealantmanufacturer’sinstructionsfor
application.
• Useahigh-qualityexteriorsealantmeetingtheASTMC920,
minimumClass25sealant.
•
Installkick-outashingtodirectthewaterintothegutter
•
Installstepashingwithminimum4in.upperleg
•
Properlyintegrateashingwiththesecondarywater-resistive
barrier.Usehousewrap,ashingtape,z-ashing,orotheritems
asneededtomaintainthecounterashingprinciple.
•
DONOTextendthesidingortrimintothekick-outashingor
gutter
•
Maintainaclearancebetweentheendofthegutterandthe
adjoiningwalltoallowforpropermaintenanceofthesiding
•
PrimeandpaintALLexposedcutedges
K-O F
LP Siding
Minimum 1" clearance
between trim and roofing
Clean rain
gutter
Do not run trim or siding inside
of the kick out flashing
Application instructions (cont.)
F, W, D  O
• Allopeningsmustbesealedandflashedinamannerthat
preventsmoistureintrusionorwaterbuildup.Several
examplesthataccomplishthisareshown.
•
Inahorizontalbrickfriezeorbandboardapplicationwherethe
trimoverlapsthemasonryleavea3/16-inchminimumairspace
oralayerofflashingbetweenthetrimandthemasonry.
•
Horizontaltrimorbandsshallbeflashedwithadripcapto
redirectwaterawayfromthewallassembly.
space siding 3/16 in.
from corner of wall
Minimum 2 in.
overlap
PREFERRED OUTSIDE CORNER DETAIL
Trim must extend beyond face of siding.
Minimum
/ . Gap
(if necessary, increase
spacing according to siding
requirements)
INSIDE CORNER DETAIL
Figure 1
Figure 2
ALTERNATE OUTSIDE CORNER DETAIL
Minimum
/ . Gap
(if necessary,
increase spacing
according
to siding
requirements)
Trim must extend
beyond face of siding.
Figure 3
Snug
Flush
Visible fiber
Countersunk
/
/ .
Countersunk more
than
1
/8 in.
CONDITION CORRECTION
OK
OK
Paint
Apply sealant
Apply sealant and
re-nail
N I
•
Useaminimum8d(0.113in.diametershank),hot-dipped
galvanizednail,withaminimum0.270in.diameterhead.
•Penetratestructuralframingorwoodstructuralpanelsand
structuralframingaminimumof1in.
•
Spacenailsmaximum24in.O.C.withminimumof2nailsperstud.
• Leave
3
/16in.gapwheretrimbuttsintoothermaterialsandat
buttjoints,miterjointsandends.Whereedgesoftrimmeet
sidingmaterial,windows,doorsorotherfinishedopenings,
leaveaminimum
3
/16in.gaptoallowforpropersealing.
Provideincreasedspacingalongthetrimifspecifiedbythe
sidinginstallationinstructions.
• Leave1in.clearancebetweentrimandroofingmaterialsat
roofrake.
• Foredge-nailing,allnailholesmustbepre-drilled.Donot
attempttoedge-nailwithoutpre-drilling.
• Whenappliedasrake,cornerorbandboard,nailsmust
bespacednofurtherthan12in.apartonalternatingedges.
Nailsmustbe
3
/8in.fromtheedge.
• Climbcutthesurfaceofthesidingsuchthattherotationofthe
bladecutsdownwardontheprimedorprenishedsurface.
• Wheretrimbuttswindow,doorcasingsandmasonry,etc.leavea
3/16in.gapandseal.
• Attachmentoftrimasbattenstripswherethetrimisunableto
beattachedtoframingwillrequireadditionalsupportfroma
constructionadhesive.Useanexteriorgradeconstructionadhe-
sivethatmeetsthefollowingspecicationsandapplyaccording
totheadhesivemanufacture’sspecications.Attachthetrim
mechanicallywithhotdippedgalvanizedring-shanknailsno
smallerthan0.090inchshankdiameter.Thenailsmustattach
thetrimsucientlytosecurethetrimtothestructurewhilethe
constructionadhesivecompletesitscuringprocess.
ConstructionAdhesiveSpecications:
•Minimumbondstrength:300psi
•Minimumapplicationtemperature:40oF
•Paintablegrade
Insulated Sheathings
LPSmartSideSidingsmaybeinstalledoverlow-compressionrigid
foamorexteriorgypsum.Thefollowingprecautionsmustbefollowed:
•
AdequatebracingofthewallinaccordancewiththeInterna-
tionalCodesorotherrulingbuildingcodeisrequired.
•
Forrigidfoamsheathingupto1in.(25.4mm)thick,siding
maybenaileddirectlytothefoamsheathingunlessadrainage
planeisrequiredbythelocalbuildingcode.Naillengthmust
bein-creasedtoensureaminimum1-1/2in.(38.1mm)fastener
penetrationintothestructuralframing.
•
Forrigidfoamsheathinggreaterthan1in.(25.4mm),aminimum
1-1/2in.(38.1mm)thickby3-1/2in.(88.9mm)widevertical
strappingorfurringstripmustbeinstalledoverthesheathing
toprovideasolid,levelnailingbaseforthesiding.Thestrap-
pingmustbesecurelyfastenedtostructuralframingspacedno
greaterthan16in.O.C.(406mm)withaminimumnailpenetra-
tionof1-1/2in.(38.1mm)andamaximumnailspacingnogreater
thanthewidthofthesiding.
Louisiana-Pacicwillassumenoresponsibilityforanydamageor
conditionarisingfromtheuseofrigidfoamorexteriorgypsum.
Application instructions (cont.)
G
/

.
BUTT JOINT DETAIL
4 in. Vertical Flashing
Trim
Nail Fin (do not damage)
DOORS & WINDOWS
Glass
Minimum
/ . Gap
(if necessary, increase spacing
according to siding requirements)
/ . Space
Figure 4
Figure 5
Siding
HORIZONTAL
TRIM AND
BAND BOARD
Trim
Flashing
Brick
Flashing
/ . Space
/ . Space
Weather
Resistant
Barrier
Shim
Figure 6
J D
• Endsmustbespacedandjointsmaylightlytouchinrunsless
than16feet.Buttjointsrequirea3/16in.gapinruns16feetor
greater.Sealwithahighqualitynon-hardeningpaintablelong-
lifesealant.
•Buttjointsrequirefour(4)nailswithtwonailsoneithersideof
thejointateachedge.
TRIMBOARD 3/16 IN. JOINT DETAIL
Figure 8
Space
and seal with
sealant
Figure 9
• End-to-endjointsinverticaltrimshouldbeinstalledso
thattheyshedwater.
• Do not miter corner joints of band boards, fascia, etc.
• Allowtheendofthetrimtolapovertheendofthe
adjoiningtrim,gap3/16in.andcaulkwithsealant.
Figure 7
VINYL SIDING
Allowdrainagebetween
horizontaltrimandJ-channel
whenadjoiningvinylsiding
Window
Framing
Trim
Water release
Z flashing
Vinyl
Siding
• Donotusescarfjoints.
TheLouisiana-PacificCorporation(“LP”)LPSmartSidetrimandfascia
(the“Products”)limitedwarranty(the“Warranty”)appliesonlyto
structuresonwhichtheProductshavebeenapplied,finishedand
maintainedinaccordancewiththepublishedapplication,finishing
andmaintenanceinstructionsineffectatthetimeofapplication.
Thefailuretofollowsuchapplication,finishingormaintenance
instructionswillvoidtheWarrantyastotheportionoftheProducts
affectedbythevariance(the“AffectedProducts”).
LPassumesnoliabilityforanylossordamagesustainedbythe
AffectedProductsandisexpresslyreleasedbythepurchaseror
ownerfromanysuchlossorliability.
AnymodificationoftheWarranty’sapplication,finishingor
maintenancerequirementsisvoidandunenforceableunless
approvedinwritingpriortoapplicationbytheSidingGeneralManager
orhisdesigneeandamemberoftheLPLegalDepartment.
Foracopyofthewarrantyorforinstallationandtechnicalsupport,visitthe
LPSmartSideproductsupportWebsiteat:
orforadditionalsupportcall800-450-6106.
www.lpsmartside.com
WARRANTYREMEDIESARENOTAVAILABLEIF
REQUIREMENTSARENOTFOLLOWED.
NEVER NAIL INTO
EDGES WITHOUT
PRE DRILLING
DO NOT MITER
EDGES
SEAL AND PAINT
M
• Donotmitertrimedges.45degreemiteringoftrimends
arounddoorandwindowopeningsisacceptable,aswellas
joining.
DO NOT MITER
CUT THE
CORNER JOINT
G E
• Atgableends,abackerboard(suchasabargerafter)shouldbe
usedunderfasciatoprovidemaximumsupportalongthelength
oftheproduct(seeFigures10and11.)
• Iftrimandfasciaisinstalleddirectlytolookoutsonan
overhangingrake,thelookoutsmustbeinstallededgewiseand
mustbespacednowiderthan24in.O.C.(seeFigures10and
11).THISAPPLICATIONAPPLIESTOMINIMUM6in.540SERIES
STRANDTRIMONLY.
FASCIA DETAIL
FASCIA
SOFFIT
TRIM
Installdrip-edgeor
drip-captoprevent
waterbuildupbehind
fasciaandtrim.
Ridge
First
common rafter
End or verge
rafter
Barge rafter
2x or 4x lookouts
Fascia
Ridge
First
common rafter
End or verge
rafter
Barge rafter
2x or 4x lookouts
Fascia
F  R B  C
• Alljointsmustbesupportedby
framing.
• Donotnailfromthefaceofone
trimmemberintotheedgeof
another.
• Donotmitercutthecornerjoint.
F
DO
• Primeandpaintallexposedsurfacesincludingalldrip
edges or where water will hang.
• Applyfinishcoatassoonaspossibleorwithin180days
ofapplication.
• High-qualityacryliclatexpaint,speciallyformulatedforuseon
woodandengineeredwoodsubstrates,ishighlyrecommended.
Semi-glossorsatinfinishoiloralkydpaintsareacceptable.For
flatalkydpaint,pleasecheckwiththecoatingmanufacturerfor
theirrecommendationsforuseoncompositewoodsiding.
• Followthecoatingmanufacturer’sapplicationand
maintenanceinstructions.
DO NOT USE
• Semi-transparentandtransparentstains.
• Shakeandshinglepaints.
• Vinyl-basedresinformulassuchasvinylacetate,PVA,
vinylacetate/acryliccopolymerpaints.
HANDLE PREFINISHED LP SMARTSIDE PRODUCTS WITH
EXTREME CARE DURING STORAGE AND APPLICATION. TOUCH
UP ANY DAMAGE TO THE FINISH THAT MAY OCCUR DURING
APPLICATION PER PREFINISHERS SPECIFICATIONS.
TrimBoard
TrimBoard
2" x 6"
Blocking
Rafter
Cal. Prop 65 Warning: Use of this product may result in exposure to
wood dust, known to the State of California to cause cancer.
Application instructions (cont.)
©2014Louisiana-PacificCorporation.Allrightsreserved.LP,SmartSide,SilverTechandSmartFinish
areregisteredtrademarksofLouisiana-PacificCorporation.PrintedinU.S.A.
NOTE:Louisiana-PacificCorporationperiodicallyupdatesandrevisesitsproductinformation.
Toverifythatthisversioniscurrent,call800-450-6106.
 LPZB05211/14