LP SmartSide 27819 Installation guide

Type
Installation guide

This manual is also suitable for

G
• TherearenoNationalStandardsforwoodcompositesubstratetrim.
• LPSmartSidetrimandfasciacanbeapplieddirectlyovermaterials
suchassiding,ornaileddirectlytostructuralmembersupto
24in.O.C.
•
Allfasciamustbesupportedwithsolidwoodsubfascia. Strand based
fascia may be installed without subfascia if it is 6 in. 540 series or
larger.
• TRIMMUSTNOTBEINDIRECTCONTACTWITHMASONRY,
CONCRETE,BRICK,STONE,STUCCOORMORTAR.
• Minimum6in.clearancemustbemaintainedbetweentrim
andfinishgrade.
• Trimappliedadjacenttoporches,patios,walks,etc.musthavea
clearanceofatleast1in.aboveanysurfacewherewatermightcollect.
Thesurfacemustbeslopedorotherwisedesignedtoprovideproper
drainagesothetrimisatnotimedirectlyexposedtostandingwater.
• Trimandfasciaarenotdesignedforsiding;orstructuralapplications
andshouldnotbeusedasastructuralmemberinconstructionsuch
asatrellis,railingorfencing.
• Anon-corrosivedrip-edgeordrip-capmustbeappliedatbottomedge
ofroofingwhereitmeetsthefascia.
• Trimandfasciamustnotbeappliedtogreenorcrookedstructural
framingmembers.Donotapplytrimand/orfasciaoverrainsoakedor
buckledsheathingmaterials.
• DO NOT USE STAPLES
M
• Moisturecontrolandwatervaporcontrolarecriticalelements
ofproperhousingdesign.Checkyourlocalbuildingcodesfor
applicationproceduresforhandlingmoistureandwatervapor
inyourarea.
• Followallapplicablebuildingcodespecificationsrelatingto
preventionofmoistureintrusionintothewallassembly.LP
SmartSidetrimandfasciaisawoodproduct,and,aswithallwood
products,mustbekeptfreefromconstantsourcesofmoisture.
Lackofproperventilation;exposuretorepetitivesourcesofwater
suchassprinklers,condensation,inadequateflashing;improper
sealing;orfailuretofollowcommonbuildingpracticesthatprevent
moistureintrusionintothewall-system;maycausedamage,and
willvoidthewarranty.
C
• Forthecleanestcutandlongerbladelife,afine-toothcarbide
tippedbladeisrecommended.
• Trimandfasciaaremanufacturedwithaspecialedge
coatingwhichreducesmoisture-relatedissues.Avoidripping
androutingthetrimandfascia,asitwillleavetheedges
unprotected.Ifthetrimorfasciamaterialsmustberippedyou
must,takespecialcaretoprime,paintandsealallexposed
woodfiberasdescribedinthefinishingsection.
 
TRIM AND FASCIA
190, 440, 540, 2000 SERIES
S
• Storeoffthegroundonaflatsurface,underarooforseparate
waterproofcovering.
• Keeptrimandfasciacleananddry.Inspectpriortoapplication.
G, S  J
• Sealallgapswithahigh-quality,non-hardening,paintable
sealant.Followthesealantmanufacturer’sinstructionsfor
application.
• Useahigh-qualityexteriorsealantmeetingtheASTMC920,
minimumClass25sealant.
•
Installkick-outashingtodirectthewaterintothegutter
•
Installstepashingwithminimum4in.upperleg
•
Properlyintegrateashingwiththesecondarywater-resistive
barrier.Usehousewrap,ashingtape,z-ashing,orotheritems
asneededtomaintainthecounterashingprinciple.
•
DONOTextendthesidingortrimintothekick-outashingor
gutter
•
Maintainaclearancebetweentheendofthegutterandthe
adjoiningwalltoallowforpropermaintenanceofthesiding
•
PrimeandpaintALLexposedcutedges
K-O F
LP Siding
Minimum 1" clearance
between trim and roofing
Clean rain
gutter
Do not run trim or siding inside
of the kick out flashing
Application instructions (cont.)
F, W, D  O
• Allopeningsmustbesealedandflashedinamannerthat
preventsmoistureintrusionorwaterbuildup.Several
examplesthataccomplishthisareshown.
•
Inahorizontalbrickfriezeorbandboardapplicationwherethe
trimoverlapsthemasonryleavea3/16-inchminimumairspace
oralayerofflashingbetweenthetrimandthemasonry.
•
Horizontaltrimorbandsshallbeflashedwithadripcapto
redirectwaterawayfromthewallassembly.
space siding 3/16 in.
from corner of wall
Minimum 2 in.
overlap
PREFERRED OUTSIDE CORNER DETAIL
Trim must extend beyond face of siding.
Minimum
/ . Gap
(if necessary, increase
spacing according to siding
requirements)
INSIDE CORNER DETAIL
Figure 1
Figure 2
ALTERNATE OUTSIDE CORNER DETAIL
Minimum
/ . Gap
(if necessary,
increase spacing
according
to siding
requirements)
Trim must extend
beyond face of siding.
Figure 3
Snug
Flush
Visible fiber
Countersunk
/
/ .
Countersunk more
than
1
/8 in.
CONDITION CORRECTION
OK
OK
Paint
Apply sealant
Apply sealant and
re-nail
N I
•
Useaminimum8d(0.113in.diametershank),hot-dipped
galvanizednail,withaminimum0.270in.diameterhead.
•Penetratestructuralframingorwoodstructuralpanelsand
structuralframingaminimumof1in.
•
Spacenailsmaximum24in.O.C.withminimumof2nailsperstud.
• Leave
3
/16in.gapwheretrimbuttsintoothermaterialsandat
buttjoints,miterjointsandends.Whereedgesoftrimmeet
sidingmaterial,windows,doorsorotherfinishedopenings,
leaveaminimum
3
/16in.gaptoallowforpropersealing.
Provideincreasedspacingalongthetrimifspecifiedbythe
sidinginstallationinstructions.
• Leave1in.clearancebetweentrimandroofingmaterialsat
roofrake.
• Foredge-nailing,allnailholesmustbepre-drilled.Donot
attempttoedge-nailwithoutpre-drilling.
• Whenappliedasrake,cornerorbandboard,nailsmust
bespacednofurtherthan12in.apartonalternatingedges.
Nailsmustbe
3
/8in.fromtheedge.
• Climbcutthesurfaceofthesidingsuchthattherotationofthe
bladecutsdownwardontheprimedorprenishedsurface.
• Wheretrimbuttswindow,doorcasingsandmasonry,etc.leavea
3/16in.gapandseal.
• Attachmentoftrimasbattenstripswherethetrimisunableto
beattachedtoframingwillrequireadditionalsupportfroma
constructionadhesive.Useanexteriorgradeconstructionadhe-
sivethatmeetsthefollowingspecicationsandapplyaccording
totheadhesivemanufacture’sspecications.Attachthetrim
mechanicallywithhotdippedgalvanizedring-shanknailsno
smallerthan0.090inchshankdiameter.Thenailsmustattach
thetrimsucientlytosecurethetrimtothestructurewhilethe
constructionadhesivecompletesitscuringprocess.
ConstructionAdhesiveSpecications:
•Minimumbondstrength:300psi
•Minimumapplicationtemperature:40oF
•Paintablegrade
Insulated Sheathings
LPSmartSideSidingsmaybeinstalledoverlow-compressionrigid
foamorexteriorgypsum.Thefollowingprecautionsmustbefollowed:
•
AdequatebracingofthewallinaccordancewiththeInterna-
tionalCodesorotherrulingbuildingcodeisrequired.
•
Forrigidfoamsheathingupto1in.(25.4mm)thick,siding
maybenaileddirectlytothefoamsheathingunlessadrainage
planeisrequiredbythelocalbuildingcode.Naillengthmust
bein-creasedtoensureaminimum1-1/2in.(38.1mm)fastener
penetrationintothestructuralframing.
•
Forrigidfoamsheathinggreaterthan1in.(25.4mm),aminimum
1-1/2in.(38.1mm)thickby3-1/2in.(88.9mm)widevertical
strappingorfurringstripmustbeinstalledoverthesheathing
toprovideasolid,levelnailingbaseforthesiding.Thestrap-
pingmustbesecurelyfastenedtostructuralframingspacedno
greaterthan16in.O.C.(406mm)withaminimumnailpenetra-
tionof1-1/2in.(38.1mm)andamaximumnailspacingnogreater
thanthewidthofthesiding.
Louisiana-Pacicwillassumenoresponsibilityforanydamageor
conditionarisingfromtheuseofrigidfoamorexteriorgypsum.
Application instructions (cont.)
G
/

.
BUTT JOINT DETAIL
4 in. Vertical Flashing
Trim
Nail Fin (do not damage)
DOORS & WINDOWS
Glass
Minimum
/ . Gap
(if necessary, increase spacing
according to siding requirements)
/ . Space
Figure 4
Figure 5
Siding
HORIZONTAL
TRIM AND
BAND BOARD
Trim
Flashing
Brick
Flashing
/ . Space
/ . Space
Weather
Resistant
Barrier
Shim
Figure 6
J D
• Endsmustbespacedandjointsmaylightlytouchinrunsless
than16feet.Buttjointsrequirea3/16in.gapinruns16feetor
greater.Sealwithahighqualitynon-hardeningpaintablelong-
lifesealant.
•Buttjointsrequirefour(4)nailswithtwonailsoneithersideof
thejointateachedge.
TRIMBOARD 3/16 IN. JOINT DETAIL
Figure 8
Space
and seal with
sealant
Figure 9
• End-to-endjointsinverticaltrimshouldbeinstalledso
thattheyshedwater.
• Do not miter corner joints of band boards, fascia, etc.
• Allowtheendofthetrimtolapovertheendofthe
adjoiningtrim,gap3/16in.andcaulkwithsealant.
Figure 7
VINYL SIDING
Allowdrainagebetween
horizontaltrimandJ-channel
whenadjoiningvinylsiding
Window
Framing
Trim
Water release
Z flashing
Vinyl
Siding
• Donotusescarfjoints.
TheLouisiana-PacificCorporation(“LP”)LPSmartSidetrimandfascia
(the“Products”)limitedwarranty(the“Warranty”)appliesonlyto
structuresonwhichtheProductshavebeenapplied,finishedand
maintainedinaccordancewiththepublishedapplication,finishing
andmaintenanceinstructionsineffectatthetimeofapplication.
Thefailuretofollowsuchapplication,finishingormaintenance
instructionswillvoidtheWarrantyastotheportionoftheProducts
affectedbythevariance(the“AffectedProducts”).
LPassumesnoliabilityforanylossordamagesustainedbythe
AffectedProductsandisexpresslyreleasedbythepurchaseror
ownerfromanysuchlossorliability.
AnymodificationoftheWarranty’sapplication,finishingor
maintenancerequirementsisvoidandunenforceableunless
approvedinwritingpriortoapplicationbytheSidingGeneralManager
orhisdesigneeandamemberoftheLPLegalDepartment.
Foracopyofthewarrantyorforinstallationandtechnicalsupport,visitthe
LPSmartSideproductsupportWebsiteat:
orforadditionalsupportcall800-450-6106.
www.lpsmartside.com
WARRANTYREMEDIESARENOTAVAILABLEIF
REQUIREMENTSARENOTFOLLOWED.
NEVER NAIL INTO
EDGES WITHOUT
PRE DRILLING
DO NOT MITER
EDGES
SEAL AND PAINT
M
• Donotmitertrimedges.45degreemiteringoftrimends
arounddoorandwindowopeningsisacceptable,aswellas
joining.
DO NOT MITER
CUT THE
CORNER JOINT
G E
• Atgableends,abackerboard(suchasabargerafter)shouldbe
usedunderfasciatoprovidemaximumsupportalongthelength
oftheproduct(seeFigures10and11.)
• Iftrimandfasciaisinstalleddirectlytolookoutsonan
overhangingrake,thelookoutsmustbeinstallededgewiseand
mustbespacednowiderthan24in.O.C.(seeFigures10and
11).THISAPPLICATIONAPPLIESTOMINIMUM6in.540SERIES
STRANDTRIMONLY.
FASCIA DETAIL
FASCIA
SOFFIT
TRIM
Installdrip-edgeor
drip-captoprevent
waterbuildupbehind
fasciaandtrim.
Ridge
First
common rafter
End or verge
rafter
Barge rafter
2x or 4x lookouts
Fascia
Ridge
First
common rafter
End or verge
rafter
Barge rafter
2x or 4x lookouts
Fascia
F  R B  C
• Alljointsmustbesupportedby
framing.
• Donotnailfromthefaceofone
trimmemberintotheedgeof
another.
• Donotmitercutthecornerjoint.
F
DO
• Primeandpaintallexposedsurfacesincludingalldrip
edges or where water will hang.
• Applyfinishcoatassoonaspossibleorwithin180days
ofapplication.
• High-qualityacryliclatexpaint,speciallyformulatedforuseon
woodandengineeredwoodsubstrates,ishighlyrecommended.
Semi-glossorsatinfinishoiloralkydpaintsareacceptable.For
flatalkydpaint,pleasecheckwiththecoatingmanufacturerfor
theirrecommendationsforuseoncompositewoodsiding.
• Followthecoatingmanufacturer’sapplicationand
maintenanceinstructions.
DO NOT USE
• Semi-transparentandtransparentstains.
• Shakeandshinglepaints.
• Vinyl-basedresinformulassuchasvinylacetate,PVA,
vinylacetate/acryliccopolymerpaints.
HANDLE PREFINISHED LP SMARTSIDE PRODUCTS WITH
EXTREME CARE DURING STORAGE AND APPLICATION. TOUCH
UP ANY DAMAGE TO THE FINISH THAT MAY OCCUR DURING
APPLICATION PER PREFINISHERS SPECIFICATIONS.
TrimBoard
TrimBoard
2" x 6"
Blocking
Rafter
Cal. Prop 65 Warning: Use of this product may result in exposure to
wood dust, known to the State of California to cause cancer.
Application instructions (cont.)
©2014Louisiana-PacificCorporation.Allrightsreserved.LP,SmartSide,SilverTechandSmartFinish
areregisteredtrademarksofLouisiana-PacificCorporation.PrintedinU.S.A.
NOTE:Louisiana-PacificCorporationperiodicallyupdatesandrevisesitsproductinformation.
Toverifythatthisversioniscurrent,call800-450-6106.
 LPZB05211/14
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

LP SmartSide 27819 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI