Paradyne FrameSaver 9123 Installation Instructions Manual

Category
Networking
Type
Installation Instructions Manual

Paradyne FrameSaver 9123 is a high-performance router capable of connecting a T1 line interface to an Ethernet or frame relay network. The device supports a 19.2 kbps baud rate and has both Ethernet and COM ports. It also supports a variety of advanced features, including:

  • Full Service Level Management (SLM) capability for real-time and historical network performance monitoring and SLA (Service Level Agreement) reporting
  • SNMP Trap Event Log for monitoring and troubleshooting
  • IP Routing Table for managing IP traffic
  • Performance Statistics for tracking network performance
  • PVC (Permanent Virtual Circuit) connections for establishing permanent connections between two devices

Paradyne FrameSaver 9123 is a high-performance router capable of connecting a T1 line interface to an Ethernet or frame relay network. The device supports a 19.2 kbps baud rate and has both Ethernet and COM ports. It also supports a variety of advanced features, including:

  • Full Service Level Management (SLM) capability for real-time and historical network performance monitoring and SLA (Service Level Agreement) reporting
  • SNMP Trap Event Log for monitoring and troubleshooting
  • IP Routing Table for managing IP traffic
  • Performance Statistics for tracking network performance
  • PVC (Permanent Virtual Circuit) connections for establishing permanent connections between two devices
1
FrameSaver
®
9123 Router
Installation Instructions
Document Number 9123-A2-GN11-00
March 2003
Contents
Product Documentation Online ..................................................................... 2
Upgrading a Unit to the Advanced SLM Feature Set .................................... 2
Package Checklist ......................................................................................... 2
Preparation ................................................................................................... 3
Cables You May Need to Order .................................................................... 3
Safety Instructions ........................................................................................ 4
Installing the Power Supply and Cord ........................................................... 4
Connecting to an Asynchronous Terminal or PC .......................................... 5
Verifying that Self-Test Passed ..................................................................... 5
Menu Hierarchy ............................................................................................. 6
A Quick Guide to Configuration .................................................................... 9
Full Installation and Setup ............................................................................ 10
About the Installation Procedures ................................................................. 10
Minimal Installation for Service Providers (Leased Line Mode) .................... 12
Setting Up Local Management at the Central Site ........................................ 14
Automatic Configuration ................................................................................ 14
Connecting to the Network ........................................................................... 15
Configuring SNMP Trap Managers and Traps .............................................. 16
Verifying the End-to-End Path ....................................................................... 16
Connecting to the Ethernet ........................................................................... 17
Connecting to the DTE (Router or FRAD) .................................................... 18
Verifying That Data is Being Received .......................................................... 19
Checking PVC Connections .......................................................................... 19
Important Safety Instructions ....................................................................... 20
EMI Notices .................................................................................................. 21
Government Requirements ........................................................................... 21
Warranty, Sales, Service, and Training Information ...................................... 24
Document Feedback ..................................................................................... 24
Trademarks ................................................................................................... 24
Patent Notification ......................................................................................... 24
2
Product Documentation Online
Complete documentation for this product is available at www.paradyne.com.
Select
Support
Technical Manuals
FrameSaver Frame Relay Devices.
Select the following documents:
FrameSaver SLV Technical Description
(9000-A2-GB30)
FrameSaver SLV Configuration Reference
(9000-A2-GB31)
FrameSaver SLV SNMP Reference
(9000-A2-GB32)
FrameSaver SLV Operations Guide
(9000-A2-GB33)
FrameSaver SLV Router Command Line Interface
(9000-A2-GB34)
To order a paper copy of a Paradyne document, or to speak with a sales representative,
please call 1-727-530-2000.
Upgrading a Unit to the Advanced SLM Feature Set
Full Service Level Management (SLM) capability can be activated in units that have the
basic diagnostic feature set at any time. This is an optional feature that adds real-time
and historical network performance monitoring and SLA (Service Level Agreement)
reporting capabilities to your FrameSaver unit and network. Simply order a Feature
Activation Certificate and provide the model to be activated, your OpenLane
®
SLM
system license key number, and the number of FrameSaver units to be activated to SLM
capability. You can order the certificate for a single unit or for many units.
OpenLane SLM Release 5.3 or above is required to schedule activation of SLM features
in units, and to manage the number of activations remaining on the certificate.
OpenLane also provides a Certificate Summary Report to assist you in the management
of the certificate.
When the Feature Activation Certificate arrives, add the Activation Certificate Number to
your OpenLane SLM application’s database. Activations can occur at any time, for as
many units as desired, until no activations remain for the certificate. When ready to
activate units, simply select the units to be activated and schedule the activations. The
activations occur when scheduled, and OpenLane updates the certificate information.
Contact your sales representative for additional information.
Package Checklist
Verify that your package contains the following:
FrameSaver Router
Power cord with a wall-mount 120 VAC power transformer
Self-mounting tie wrap for power cord strain relief
RJ48C modular cable for U.S. network access
Be sure to register your warranty at www.paradyne.com/warranty.
3
Preparation
Make sure you have:
A dedicated, grounded power outlet that is protected by a circuit breaker within
6 feet of the FrameSaver unit
A clean, well-lit, and ventilated site that is free from environmental extremes
One to two feet of clearance for cable connections
A physical connection to the frame relay T1 network
An asynchronous terminal or PC (personal computer)
If desired, an operable Ethernet LAN (Local Area Network) connection for access
by an NMS (Network Management System)
Configuration information for the FrameSaver unit being installed or replaced
Appropriate cables (see
Cables You May Need to Order
, below)
For additional information, see the
FrameSaver SLV Technical Description
(9000-A2-GB30)
.
Cables You May Need to Order
Contact your sales representative to order cables.
If connecting to . . . Order a . . .
Feature
Number Part Number
T1 line interface/
connector
For use in Canada.
T1 line interface cable,
RJ48C-to-CA81A
(20feet/6.1meters)
3100-F1-510 035-0221-2031
Asynchronous
terminal or PC with an
8-pin modular
interface/connector
Standard EIA-232
straight-through cable,
8-pin modular-to-DB25
(14feet/4.3meters)
3100-F2-540 035-0314-1431
PC with a D-Sub9
interface/connector
Standard EIA-232
straight-through cable,
D-Sub9-to-DB25
(14feet/4.3meters)
3100-F2-550 035-0313-1431
External device
(such as a modem)
Standard EIA-232-D
crossover cable
(14feet/4.3meters)
9008-F1-550 035-0336-1431
4
Safety Instructions
Please refer to the
Important Safety Instructions
on page 19.
Installing the Power Supply and Cord
Procedure
1. Insert the power cords plug into the POWER jack.
2. Plug the power supply into the grounded power outlet and check the LEDs.
If any LEDs light, you have power. If not, refer to
Troubleshooting
in the
FrameSaver
SLV Operations Guide (9000-A2-GB33)
for possible explanations.
3. Insert the self-mounting tie wrap in the leftmost hole (hole with a dark circle around
it) until it snaps securely into place. The tie wrap provides strain relief for the power
cord.
4. Loop the tie wrap around the power cord, thread it through the hole at the base of
the wrap, and pull it snugly around the cord.
00-16684
Grounded
Power
Outlet
OK
OK
ALM
TEST
FR
SIG
OOF
ALM
NetworkSystem
Por t
FrameSaver
TM
SLV
FrameSaver
®
FLEX
9123-C
OK
ALM
System
P
O
R
T
COM
NET
POWER
ETHERNET
5
Connecting to an Asynchronous Terminal or PC
A VT100-compatible asynchronous terminal or a PC providing VT100 terminal
emulation must be used to set up access to and management of the unit.
Procedure
1. Configure the terminal or PC so it is compatible with the FrameSaver unit:
Baud Rate set to 19.2 kbps.
Character length set to 8 data bits.
Parity set to none.
Stop bit set to 1.
Flow Control set to None.
2. Insert the DB25 end of the EIA-232 cable into the FrameSaver unit’s COM port.
3. Insert the other end of the cable into the terminal or PC.
4. Tighten the screws on each side of the connector to secure the cable.
5. Press Enter on the keyboard to display the Main Menu.
If the Main Menu does not appear, recheck the terminal or PC settings (see Step 1),
or press the Enter key. Refer to
Troubleshooting
in the
FrameSaver SLV Operations
Guide (9000-A2-GB33)
for other possible explanations.
Verifying that Self-Test Passed
To verify that the unit passed its self-test, go to the System and Test Status screen.
Main Menu
Status
System and Test Status
The results of the self-test appear directly under the screen title.
If any failure messages appear, reset the unit by disconnecting, then reconnecting the
power cord. The unit will perform the self-test again. If the failure reappears, call your
service representative for assistance.
P
0
R
T
COM
NET
POWER
ETHERNET
COM
Port
00-16685
6
Menu Hierarchy
The Menu Hierarchy shows the organization of the FrameSaver units screens. Support
for all features may not be available in the firmware release you are running.
S t at u s
System and Test
Status
Self-Test Results
Last Reset
Health and Status
Tes t St a t u s
LMI Reported
DLCIs
DLCI
Status
CIR (bps)
IP Path
Connection Status
Device Name
IP Address
Status
Discovery Source
PVC Connection
Status
Source Link, DLCI, EDLCI
Primary Destination Link, DLCI, EDLCI,
Status
Timeslot
Assignment Status
Network Timeslot Assignment Status
IP Routing Table
(Management
Traffic)
Destination
Mask
Gateway
Hop
Typ e
Interface
TTL
Performance
Statistics
Service Level Verification
DLCI
Frame Relay
ESF Line
Ethernet
Clear All Statistics
Tr a p E v e n t L o g Number of Trap Events
Time of Day
Event
Display LEDs and
Control Leads
I d e n t i t y System
NAM
7
Test
Network PVC Tests PVC Loopback
Send Pattern
Monitor Pattern
Network Physical
Tests
Local Line Loopback
Local Payload Loopback
Remote Send Line Loopback
Send Pattern
Monitor Pattern
IP Ping
Lamp Test
Abort All Tests
Configuration
System Frame Relay and LMI
PPP
Class of Service Definitions
Service Level Verification
General
Network Physical
Frame Relay
PPP
DLCI Records
Virtual Router
Ports
PPP
DLCI Records
Time Slot
Assignments
Link Layer Network Assignments
Clear Assignments
PVC Connections Source Link, DLCI, EDLCI
Primary Destination Link, DLCI, EDLCI
IP Path List Add and Display Static Paths
Management and
Communication
Options
Node IP
Management PVCs
General SNMP Management
Telnet and FTP Sessions
SNMP NMS Security
SNMP Traps
Ethernet Management
Communication Port
External Modem (on COM Port)
Auto-
Configuration
Frame Relay Discovery Mode
Automatic Circuit Removal
8
Control
System
Information
Device Name
System Name, Location, Contact
Date
Time
Administer Logins Login ID
Password
Access Level
Change Operating
Mode
Back-to-Back Mode
Standard Mode
Select Software
Release
Current Release
Alternate Release
Switch & Reset
LMI Packet
Capture Utility
Capture Interface
Packet Capture Start/Stop
Status
Packets in Buffer
Display LMI Trace Log
Clear Device Fail
Telnet
Reset Device
Easy Install
Service Type
Node IP Address
Node Subnet Mask
TS Access
Create Dedicated Network Mgmt Link
Ethernet Management Options Screen
Time Slot Assignment Screen
Network 1 Line Framing Format
Network 1 Line Build Out
Network 1 Line Coding Format
DS0 Base Rate
9
A Quick Guide to Configuration
The FrameSaver unit should operate using the default (factory-set) configuration
options, with exception to the changes specified in these installation instructions. Refer
to the following table for help in navigating through the menus.
As an example, follow these steps to go to the Configuration Edit/Display menu so you
can start setting up the unit.
To load a configuration for editing:
1. From the Main Menu, press the down arrow key twice so the cursor is on
Configuration.
2. Press Enter to display the Configuration menu. The Load Configuration From menu
appears.
3. Press Enter to select Current Configuration (the cursor is already on this selection).
The Configuration Edit/Display menu appears.
This sequence of steps would be shown as the menu selection sequence:
Main Menu Configuration
To save a configuration option change:
1. Press Ctrl-a to switch to the function keys area at the bottom of the screen.
2. Typ e s or S (S
ave) and press Enter. The Save Configuration To menu appears.
3. Press Enter again to save your changes to the Current Configuration.
4. Press Esc until the Configuration Edit/Display menu reappears to continue
configuring the unit.
Press Ctrl-a, type m (M
ainMenu), and press Enter to return to the Main Menu.
In the sections that follow, only the minimum option changes required are included so
you will have a quick and trouble-free installation. See the
FrameSaver SLV
Configuration Reference (9000-A2-GB31)
for more information.
Press the . . . To . . .
Esc key Go back one screen or menu level. To see a visual
representation of the menu levels, see
Menu Hierarchy
on
page 6.
Tab key, or
Up ( ), Down ( ),
Left ( ) and Right ( )
Arrow keys
Move the cursor from one menu item to the next.
Enter or Return key Complete the menu or option selection.
Spacebar Display the next available setting when changing a
configuration option. All the available settings for an option
appears at the bottom of the screen.
10
About the Installation Procedures
There are two methods for installing and setting up the FrameSaver unit.
One person can install and set up the unit. If this is the case, see
Full Installation
and Setup
.
An installer can physically install and set up access to the unit, and the network
operation center (NOC) can complete the setup. If this is the case, see
Minimal
Installation for Service Providers
on page 12.
Certain procedures are common to both the full installation and minimal methods. These
procedures are referenced in the full and minimal installation instructions (starting with
Setting Up Local Management at the Central Site
on page 13
Full Installation and Setup
An Easy Install screen is provided to simplify installation and setup. The Easy Install
feature can be used when one person installs and sets up the FrameSaver unit from
beginning to end.
Procedure
1. Select the Easy Install feature.
Main Menu Easy Install
About the Installation Procedures
There are two methods for installing and setting up the FrameSaver unit.
One person can install and set up the unit. If this is the case, see
Full Installation
and Setup
.
An installer can physically install and set up access to the unit in leased line mode,
and the network operation center (NOC) can switch the unit to frame relay mode
and complete the setup. If this is the case, see
An installer can physically install and set up access to the unit, and the network
operation center (NOC) can complete the setup. If this is the case, see
Minimal
Installation for Service Providers
on page 12.
Certain procedures are common to both the full installation and minimal methods. These
procedures (starting with
Setting Up Local Management at the Central Site
on page 13)
are referenced in the full and minimal installation instructions. Refer to them, as needed.
Easy Install Screen Example
2. Verify that the Service Type is Frame Relay.
main/easy_install 9123
Device Name: Node A 12/27/2002 10:32
EASY INSTALL
Node IP Address: 000.000.000.000 Clear
Node Subnet Mask: 000.000.000.000 Clear
TS Access: DLCI 980
Create a Dedicated Network Management Link
Ethernet Port Options Screen
Time Slot Assignment Screen
Network 1 Line Framing Format: ESF
Network 1 Line Build Out (LBO): 0.0
Network 1 Line Coding Forma B8ZS
DS0 Base Rate (Kbps): Nx64
-----------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
Save
11
3. Enter the Node IP Address and Subnet Mask.
4. Set TS Access to DLCI, then select a DLCI on the network interface that will be
used for the troubleshooting access link.
5. Create a Dedicated Network Management Link, selecting a DLCI for the
management link at the Which DLCI would you like to Create a
Dedicated Network Management Link on? prompt, which will be used by
the NOC to access the unit.
6. Select the Ethernet Port Options Screen and configure the following:
Enable Interface Status. If the NMS will be on a different subnet than the unit,
enter Y
es at the Would you like to set the Node's Default IP
Destination to Ethernet? prompt. Otherwise, enter No.
If the IP Address and Subnet Mask are unique to the interface, enter them for
the port; otherwise, the Node IP Address and Subnet Mask will be used.
Enter the Default Gateway Address; the IP Address that will be used for
packets without a route.
Enable Proxy ARP if the unit will proxy for downstream FrameSaver units
learned via the proprietary RIP (Routing Information Protocol) feature.
Press the Esc key to return to the Easy Install screen.
7. Configure the T1 network interface options to match the service provider’s settings.
8. S
ave the configuration.
9. Install the network cable (see
Connecting to the Network
on page 15). The
FrameSaver unit starts discovering DLCIs and network time slots (see
Automatic
Configuration
on page 14).
10. Install the Ethernet cable (see
Connecting to the Ethernet
on page 17).
The remaining steps are optional, depending upon the application. They are performed
from the Main Menu.
11. If the unit will be enforcing CIR (Committed Information Rate) and EIR (Excess
Information Rate) on network frame relay links, enable Traffic Policing.
Main Menu Configuration Network Frame Relay
You can change other Frame Relay and LMI default settings, if necessary.
12. Configure the network interface according to the local management interface (LMI)
and assigned line conditions supplied by the service provider.
Configuration Network Frame Relay
13. Set up SNMP management and local management (see
Setting Up Local
Management at the Central Site
on page 13).
14. If SNMP traps are wanted, set up managers and select the desired traps (see
Configuring SNMP Trap Managers and Traps
on page 16).
The FrameSaver installation is complete.
12
Minimal Installation for Service Providers
Verify with your service provider that frame relay service is turned on at the site. Follow
Step 1 through Step 10 of
Full Installation and Setup
on page 10.
Physical installation of the unit is complete; the NOC can now remotely access the unit
for additional configuration.
Completing Setup of the Unit From the NOC
Procedure
1. Access the remote FrameSaver unit using the dedicated management link, using
the Node IP Address that was entered.
2. Configure specific frame relay options, like CIR (committed information rate), and
any other configuration options requiring input or changes from the default settings.
3. Configure the network interface according to the local management interface (LMI)
and assigned line conditions supplied by the service provider.
Configuration Network Frame Relay
4. If SNMP traps are wanted, set up managers, select the desired traps, and configure
trap dial-out if desired (see
Configuring SNMP Trap Managers and Traps
on
page 16).
5. Save the configuration.
6. Verify that data is being received (see
Verifying That Data is Being Received
on
page 18).
7. Verify that all PVCs, including Management PVCs, are configured; and see whether
the PVC is active or not (see
Checking PVC Connections
on page 18).
The FrameSaver installation is complete.
13
Setting Up Local Management at the Central Site
Procedure
1. Create a DLCI for the virtual router port.
Configuration Virtual Router Ports DLCI Records
2. Save the configuration.
3. Create a Management PVC using the virtual router port DLCI just created.
Configuration Management and Communication Management PVC
Minimally, enter the following options:
Name for the management PVC
Interface IP Address and Subnet Mask, if different from the Node’s
Primary Link for this Management PVC (the virtual router data port)
Primary DLCI (the virtual router port DLCI)
4. S
ave the configuration.
14
Automatic Configuration
The FrameSaver unit provides several automatic configuration features. Frame Relay
Discovery and configuration is one of these features.
Main Menu Auto-Configuration
The default discovery mode is 1PPort. In this mode:
Auto-Configuration is enabled on the virtual router port.
A virtual router port DLCI is created for each network DLCI and automatically
cross-connected to it.
Payload management is configured for the network DLCI and assigned the Node IP
Address.
NOTE:
When auto-configuration creates a multiplexed DLCI, but a standard DLCI is
needed, change the DLCI to Standard from the network DLCI Records screen:
Configuration Network DLCI Records
Other modes can be selected. See
Setting Up Automatic Configuration
in
Configuration
of the
FrameSaver SLV Configuration Reference (9000-A2-GB31)
for information about
other modes and how the Frame Relay Discovery Mode can be changed.
No automatic configuration occurs until the network cable is connected. If you do not
want management links configured or automatic configuration, change the default
setting for the Frame Relay Discovery feature.
Time Slot Assignment
Network time slots are discovered automatically when Time Slot Discovery is enabled
(the default setting) on the Frame Relay Network 1 Assignments screen. This feature
can be disabled if you want to manually configure time slots.
See
Assigning Time Slots/Cross Connections
in the
FrameSaver SLV Configuration
Reference (9000-A2-GB31)
for additional information about this feature.
15
Connecting to the Network
Now that the FrameSaver unit is set up, the unit can be connected to the network.
Procedure
1. Insert the 8-pin connector of the RJ48C network cable into the network interface.
2. Insert the other end of the cable into the RJ48C modular jack.
NOTE:
After connecting the network cable, wait about a minute to allow
Auto-Configuration a chance to discover the operating rate and the DLCIs.
3. Verify that the Network signal (SIG) LED is green, and that the Network
out-of-frame (OOF) and alarm (ALM) LEDs are off. If so, the network interface is set
up correctly and is operational. If not, make sure both ends of the network cable are
properly seated.
4. Check Health and Status messages in the left column of the System and Test
Status screen.
Main Menu Status System and Test Status
Verify that LMI is up. If LMI Down, Network appears for more than three
minutes, or any other network-related status message appears, refer to the status
information in the
FrameSaver SLV Operations Guide (9000-A2-GB33)
for possible
reasons and resolutions.
P
0
R
T
COM
NET
POWER
ETHERNET
00-16686
RJ48C
Jack
16
Configuring SNMP Trap Managers and Traps
Once the FrameSaver unit is connected to the network, SNMP trap managers and
SNMP traps can be configured.
Procedure
To enter SNMP managers and configure traps:
1. Select SNMP Traps.
Main Menu Configuration Management and Communication
SNMP Traps
2. Configure the following:
Enable SNMP Traps.
Identify the total Number of Trap Managers.
Specify the IP address of the NMS(s) to which traps will be sent.
Specify the Initial Route Destination for the Trap Manager(s).
Select desired trap categories.
3. S
ave the configuration.
4. Return to the Main Menu.
17
Connecting to the Ethernet
Procedure
1. Insert one 8-pin connector of the Ethernet cable into the Ethernet port.
2. Insert the other end of the cable into the Ethernet interface of the LAN where the
NMS resides.
3. Check Health and Status messages in the left column of the System and Test
Status screen to verify that there are no Ethernet-related Health and Status
messages.
Main Menu
Status System and Test Status
If the Ethernet Link Down message appears, make sure both ends of the
Ethernet cable are properly seated.
P
O
R
T
COM
NET
POWER
ETHERNET
00-16687
NMS
LAN
18
Verifying That Data is Being Received
Procedure
1. Return to the Main Menu.
2. Select Performance Statistics, and select an interface’s frame relay statistics.
Main Menu Status Performance Statistics Frame Relay Net1-FR1
3. Verify that the Frames Received and Characters Received counts under the
Frame Relay Link statistics are incrementing, and there are no errors under the
Frame Relay LMI statistics.
If count increments occur after refreshing the screen, the unit is receiving data.
If data is not being received, recheck the cable connections, and replace or
repair a damaged cable. Recheck LMI status; you may need to contact your
service provider. Next, check the DLCI’s status.
Checking PVC Connections
Check PVC connections to verify that all PVCs, including management PVCs, are
configured, and to see whether the PVC is active or not.
Procedure
1. Press Esc to return to the Status menu.
2. Select PVC Connection Status.
The PVC Connection Status screen shows all PVC connections; the interface
source and DLCI number of the incoming data linked to the interface and DLCI
number for the outgoing data. You can also see whether the PVC is active.
3. Verify that each PVC is active.
If active, the FrameSaver unit should be passing data.
If not active, no data traffic can be carried by the PVC. If the PVC is configured
correctly, the circuit may be down.
Provisioning the Router Interface
The FrameSaver SLV 9123 Router defaults to bridge mode. Routing without bridging,
and simultaneous routing and bridging, are also options.
Use the bridge command from the router’s CLI to configure the bridge and routing
attributes. Also, enter an Ethernet IP address and a DHCP IP address. Refer to the
FrameSaver SLV Router Command Line Interface
for CLI commands and default
settings.
19
Important Safety Instructions
1. Read and follow all warning notices and instructions marked on the product or
included in the manual.
2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable
operation of the product and to protect it from overheating, these slots and
openings must not be blocked or covered.
3. Do not allow anything to rest on the power cord and do not locate the product where
persons will walk on the power cord.
4. Do not attempt to service this product yourself, as opening or removing covers may
expose you to dangerous high voltage points or other risks. Refer all servicing to
qualified service personnel.
5. General purpose cables are provided with this product. Special cables, which may
be required by the regulatory inspection authority for the installation site, are the
responsibility of the customer.
6. When installed in the final configuration, the product must comply with the
applicable Safety Standards and regulatory requirements of the country in which it
is installed. If necessary, consult with the appropriate regulatory agencies and
inspection authorities to ensure compliance.
7. A rare phenomenon can create a voltage potential between the earth grounds of
two or more buildings. If products installed in separate buildings are
interconnected, the voltage potential may cause a hazardous condition. Consult a
qualified electrical consultant to determine whether or not this phenomenon exists
and, if necessary, implement corrective action prior to interconnecting the products.
8. In addition, if the equipment is to be used with telecommunications circuits, take the
following precautions:
Never install telephone wiring during a lightning storm.
Never install telephone jacks in wet locations unless the jack is specifically
designed for wet locations.
Never touch uninsulated telephone wires or terminals unless the telephone line
has been disconnected at the network interface.
Use caution when installing or modifying telephone lines.
Avoid using a telephone (other than a cordless type) during an electrical storm.
There may be a remote risk of electric shock from lightning.
Do not use the telephone to report a gas leak in the vicinity of the leak.
!
20
EMI Notices
UNITED STATES – EMI NOTICE:
!
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case, the user
will be required to correct the interference at his own expense.
The authority to operate this equipment is conditioned by the requirements
that no modifications will be made to the equipment unless the changes or
modifications are expressly approved by Paradyne.
CANADA – EMI NOTICE:
!
This Class A digital apparatus meets all requirements of the Canadian
interference-causing equipment regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du
règlement sur le matériel brouilleur du Canada.
Government Requirements
Certain governments require that instructions pertaining to connection to the telephone
network be included in the user documentation. Specific instructions are listed in the
following sections.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Paradyne FrameSaver 9123 Installation Instructions Manual

Category
Networking
Type
Installation Instructions Manual

Paradyne FrameSaver 9123 is a high-performance router capable of connecting a T1 line interface to an Ethernet or frame relay network. The device supports a 19.2 kbps baud rate and has both Ethernet and COM ports. It also supports a variety of advanced features, including:

  • Full Service Level Management (SLM) capability for real-time and historical network performance monitoring and SLA (Service Level Agreement) reporting
  • SNMP Trap Event Log for monitoring and troubleshooting
  • IP Routing Table for managing IP traffic
  • Performance Statistics for tracking network performance
  • PVC (Permanent Virtual Circuit) connections for establishing permanent connections between two devices

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI