INSTALLATION
1. Unscrewexisngshowerheadfromshowerarm.
2. Screwfilterhousing(Back)ontoshowerarm.
3. Screwshowerheadontofilterhousing(Front).
4. Donotusewithashut‐offvalve.
OPERATION
BEFOREENTERINGTHESHOWER
1. Acvatefilterbyrunninghotwaterthroughtheshower
system.
2. COOLTODESIREDTEMPERATUREBEFOREENTERING
SHOWER.
3. Replacethefiltercartridge(modelHOC)every25,000
gallonsor1year,whichevercomesfirst.
MAINTENANCE
1. Reversefiltercartridgeperiodicallytoensureproper
filtraonperformanceandwaterflow.
2. ReplaceHOCfiltercartridgeevery25,000gallonsor1
year,whichevercomesfirst.
FILTERCARTRIDGEREPLACEMENT(HOC)Replacefiltercar‐
tridgeevery25,000gallonsor1year,whichevercomesfirst.
1. Toopen,unscrewshowerfilterhousing.
2. Removeusedfiltercartridge.
3. CleanandlubricateO‐ringswithpetroleumjelly.
4. Toclose,screwhousingstogether.
RECYCLEFILTERCARTRIDGE
1. Carefullypokeaholeinthescreenofthe
filtercartridgeandemptycontentsintogarden
soil.
2. Placethefiltercartridgeinwithrecyclables.
USE&CAREINSTRUCTIONS
HIGH‐OUTPUTSHOWERFILTER
ModelHO2
SpriteIndustries,Inc.
TheShowerFilterCompany
1791RailroadSt,Corona,CA92880‐2511
Phone:800‐327‐9137Fax:951‐735‐1016
PERFORMANCEDATA:(ModelHO2)
RatedServiceFlow–2.5gallonsperminute/9.5litersper
minute
RatedServiceLifeforFreeChlorineremoval–25,000gallons/
94,635litersor1year(whichevercomesfirst)
MaximumWorkingPressure–125poundspersquareinch/
860kilopascals.
MaximumOperangTemperature‐120°Fahrenheit/49°Cel‐
sius.
• While tesƟng was performed under laboratory condiƟons.
Actual performance may vary.
• This system is not intended to be used as a drinking water
treatment unit.
• Both the system and installaƟon must comply with appli-
cable state and local regulaƟons.
ThisSpriteShowerFiltraonSystemhasbeentestedaccording
toNSF/ANSI177forreduconoffreechlorine.Theconcentra‐
on of free available chlorine in water entering the system
wasreducedtoaconcentraonless than
orequalto theper‐
missiblelimitforwaterleavingthesystem,asspecifiedinNSF/
ANSI177.Thissystemhasnotbeenevaluatedforfreechlorine
reduconinthepresenceofchloramines.Freechlorinereduc‐
onperformancemaybeimpactedbythepresenceofchlora‐
minesin
thewatersupply.
NotesonNSFTestProtocol:
Minimum chlorine reducon per NSF/ANSI 177
shall be listed as≥50% free available chlorine
(FAC) when used with an influent challenge water
of2mg/L FAC. Averageconcentraonsshall bethe arithmec
meanofallreportedinfluentchallengeorproductwatercon‐
centraons(thedetecon
limitvalueshallbeusedforanynon
‐detectable concentraon). The specified average percent re‐
duconshallnot begreaterthanthe reducon calculated us‐
ing the arithmec means of the influent challenge and the
productwaterconcentraonsrespecvely.