Gima 30627 Owner's manual

Type
Owner's manual
GB‐32
MA391b_EN
Instruction’sManual
Informationabouteliminationofthisproduct
(ApplicableintheEuropeanUnionandotherEuropeancountrieswith
separatecollectionsystems)
On the end of the life, the present product mustn’t be
eliminated as urban refusal, but it must be eliminated in a
separated collection.
If the product is eliminated in unsuitable way, it is possible
that some parts of the product (for example some
accumulators) could be negative for the environment and
for the human health.
The symbol on the side (barred dustbin on wheel) denotes
that the products mustn’t throw into urban refuses container
but it must be eliminated with separate collection.
In case of abusive elimination of this product, could be
foreseen sanctions.
DIATERMO5080
GIMASpA
EN‐31
MA391b_EN
Instruction’sManualManualed’Istruzioni
DEUTSCHPORTUGUES FRANCOIS ESPANOL ENGLISH ITALIANO
DIATERMO 80
COAG
0
20
40
60
0 1020304050
SET
POWER
POWER
DiagramsofoutputpowerCOAGversusnominal
value
MICRO
0
5
10
15
20
25
0 5 10 15 20
SET
POWER
POWER
DiagramsofoutputpowerMICROversusnominal
value
CUT
0
50
10 0
15 0
200
250
300
350
400
450
500
0 1020304050607080
SET
Vp
VOLTAGE
DiagramsofCUTmaximummainsvoltage
outputversusVp
BLEND
0
50
10 0
15 0
200
250
300
350
400
450
500
550
0 102030405060
SET
Vp
VOLTAGE
DiagramsofBLENDmaximummainsvoltage
outputversusVp
COAG
0
50
10 0
15 0
200
250
300
350
400
450
500
550
0 1020304050
SET
Vp
VOLTAGE
DiagramsofCOAGmaximummainsvoltage
outputversusVp
MICRO
0
50
10 0
15 0
200
250
300
350
400
450
500
05101520
SET
Vp
VOLTAGE
DiagramsofMICROmaximummainsvoltage
outputversusVp
GB‐30
MA391b_EN
Instruction’sManual
DIATERMO 80
CUT
0
20
40
60
80
100
0 250 500 750 1000 1250 1500 1750 2000
LOAD
POWER
CUT100% CUT50%
Diagramsofhalfandmaximumoutputpower
versusimpedanceload1002000
CUT
BLEND
0
20
40
60
80
0 250 500 750 1000 1250 1500 1750 2000
LOAD
POWER
BLEND100% BLEND50%
Diagramsofhalfandmaximumoutputpower
versusimpedanceload1002000
BLEND
COAG
0
20
40
60
0 250 500 750 1000 1250 1500 1750 2000
LOAD
POWER
COAG100% COAG50%
Diagramsofhalfandmaximumoutputpower
versusimpedanceload1002000
COAG
MICRO
0
10
20
30
0 250 500 750 1000 1250 1500 1750 2000
LOAD
POWER
MICRO100% MICRO50%
Diagramsofhalfandmaximumoutputpower
versusimpedanceload1002000
MICRO
CUT
0
20
40
60
80
10 0
0 10 2030405060 7080
SET
POWER
POWER
DiagramsofoutputpowerCUTversusnominal
value
BLEND
0
20
40
60
80
0 102030405060
SET
POWER
POWER
DiagramsofoutputpowerBLENDversusnominal
value
DIATERMO5080
GIMASpA
EN‐29
MA391b_EN
Instruction’sManualManualed’Istruzioni
DEUTSCHPORTUGUES FRANCOIS ESPANOL ENGLISH ITALIANO
DIATERMO 50
0
10
20
30
40
50
0 10203040
POWER
SET
CUT2
POWER
DiagramsofoutputpowerCUT2versusnominal
value
0
10
20
30
40
50
0 10203040
POWER
SET
COAG
POWER
DiagramsofoutputpowerCOAGversusnominal
value
0
50
100
150
200
250
300
350
400
450
500
0 1020304050
Vp
SET
CUT
DiagramsofCUTmaximummainsvoltage
outputversusVp
0
50
100
150
200
250
300
350
400
450
500
0153045
Vp
SET
CUT1
DiagramsofCUT1maximummainsvoltage
outputversusVp
0
50
100
150
200
250
300
350
400
450
500
0 10203040
Vp
SET
CUT2
DiagramsofCUT2maximummainsvoltage
outputversusVp
0
50
100
150
200
250
300
350
400
450
500
0 10203040
Vp
SET
COAG
DiagramsofCOAGmaximummainsvoltage
outputversusVp
GB‐28
MA391b_EN
Instruction’sManual
DIAGRAMS
DIATERMO 50
0
10
20
30
40
50
60
0 250 500 750 1000 1250 1500 1750 2000
POWER
LOAD
CUT
CUT100%
CUT50%
Diagramsofhalfandmaximumoutputpower
versusimpedanceload1002000
CUT
0
10
20
30
40
50
0 250 500 750 1000 1250 1500 1750 2000
POWER
LOAD
CUT1
CUT1-100%
CUT1-50%
Diagramsofhalfandmaximumoutputpower
versusimpedanceload1002000
CUT1
0
10
20
30
40
50
0 250 500 750 1000 1250 1500 1750 2000
POWER
LOAD
CUT2
CUT2-100%
CUT2-50%
Diagramsofhalfandmaximumoutputpower
versusimpedanceload1002000
CUT2
0
10
20
30
40
50
0 250 500 750 1000 1250 1500 1750 2000
POWER
LOAD
COAG
COAG100%
COAG50%
Diagramsofhalfandmaximumoutputpower
versusimpedanceload1002000
COAG
0
10
20
30
40
50
60
01020304050
POWER
SET
CUT
POWER
DiagramsofoutputpowerCUTversusnominal
value
0
10
20
30
40
50
0 5 10 15 20 25 30 35 40 45
POWER
SET
CUT1
POWER
DiagramsofoutputpowerCUT1versusnominal
value
DIATERMO5080
GIMASpA
EN‐27
MA391b_EN
Instruction’sManualManualed’Istruzioni
DEUTSCHPORTUGUES FRANCOIS ESPANOL ENGLISH ITALIANO
CheckingoftheEquipmentBeforeEachUse
Eachtimetheuseoftheelectrosurgicalequipmentisplannedacheckofthemost
importantsafetyaspectshastobeimplementedconsideringatleastthefollowing:
Checktheintegrityofcords,connections,wiresbreakage,etc.
Assurethatalltheelectricalequipmentisproperlygrounded.
Assurethatalltheaccessoriesthatshouldbeusedareavailableandsterilized.
OnlyforDIATERMO80check,bydisconnectingtheneutralelectrodecable,the
functioningoftheOClight.ActiveunitandcheckOClightandsoundalarm
warning.
Check,byactivatingthepowerswitch,thefunctioningoftheemissionsounds
warnings.
FunctionandSafetyCheckandTest
Atleastonceayear,thebiomedicalengineeringdepartmentorotherqualified
personnelshoulddothefollowingcheckandtest:
Checkoftheconnectorsandmainssupplycordconditions.
Visualcheckofthemechanicalprotections.
Checkoftheprotectionsagainstthedangerduetoliquid'spouring,dripping,
moisture,liquid'spenetration,cleanliness,sterilizationanddisinfection.
CheckoftheEquipment'sDataontheLabel.
CheckoftheavailabilityoftheInstruction'sManual.
CheckthefunctioningoftheH.F.outputcontrols.
Checktheuniformityoftheresistancethroughthesurfaceofthepatientplate.
Testtheearthconductivityresistance.
Testtheearthleakagecurrent.
TestH.F.leakagecurrent.
Controloftheneuromuscularstimulation.
Controloftheaccuracyoftheoutputpower.

GB‐26
MA391b_EN
Instruction’sManual
ProblemsProbableCause Solution
ErrorCode94Errorinthedataconversion
circuit.
CallforService.
ErrorCode95Errorofthereferencevoltage
value.
Verifythemainvoltage.
CallforService.
ErrorCode99Errorintheoutputpower
activationcircuit. CallforService.
Repairs
Highfrequencycablesandelectrodeholderhandlecannotberepaired.Always
substituteadamagedpartwithanewone.
FusesSubstitution
Beforesubstitutingthefuse,disconnecttheunitfromthemainssystem
Onlyusefuseofthekind5x20,proceedasfollows:
(AB)Extractthefuseholderdrawerfromthepowermodule.
(C)Insertthefusesmakingreferencetothefollowingchart:
DIATERMO50
MainsVoltage 110120V DelayedFuse2xT2A/5x20mm
MainsVoltage220240VDelayedFuse2xT1A/5x20mm
DIATERMO80
MainsVoltage 110120V DelayedFuse2xT4A/5x20mm
MainsVoltage220240VDelayedFuse2xT2A/5x20mm
(D)Extractandrotatethedetachablepartinwaytoreadthecorrectvoltageinthe(E)
windowreinsertthefuseholderinthemodule.
DIATERMO5080
GIMASpA
EN‐25
MA391b_EN
Instruction’sManualManualed’Istruzioni
DEUTSCHPORTUGUES FRANCOIS ESPANOL ENGLISH ITALIANO
MAINTENANCE
General
Nouseradjustablepartsarewithintheequipment,eitherforcalibrationorservice
purposes.
Theequipmenthousingmustnotbeopened:thewarrantyisinvalidatedbyany
unauthorizedentryintotheunit.Intheeventanyrepairoradjustmentworkbeing
necessary,thewholeequipmentshouldbereturnedtotheLEDSpAServiceCentre
04011APRILIA(LT)‐ITALY,ortoanotherAuthorizedCentre,togetherwitha
descriptionofthefault.
Maintenanceworkbytheuserismainlythecleaningoftheexteriorofthecabinet,
cleaningandsterilizationoftheaccessoryitemsandcheckingoftheequipmentbefore
eachuse.Carryingoutfunctionandsafetycheckforverificationoftheparametersis
demandedtospecializedtechnicalpeople.
CleaningoftheCabinet
Switchtheequipmentoffcompletelyanddisconnectthemainssupplybeforeany
cleaningisundertaken.Cleantheoutsideofthecabinetwithadampcloth.Nochemical
shouldbeused;amildnonabrasivecleansermaybeusedwhennecessary.
CleaningandSterilizationoftheAccessoriesItem
Thebestthingtodoistouseonlyonetimeuseaccessoriesanddiscardthemafteruse.
Sincesomeoftheaccessoryitemsaretobeusedmorethanonceitismandatoryto
cleancarefullyandsterilizethoseaccessoriesbeforethenewuse.Thebestwayto
cleanandsterilizethereusableitemsistofollowthedirectionofthesupplierofeach
item.WhenoriginalreusableaccessoriessuppliedbyLEDSpAareapplied,thecleaning
byusingdeepcleanserandsterilizationthroughsteamsterilizationat121°C/134°Cis
recommended.
GuidetotheSolutionoftheProblems
Incaseofproblemsbeforeallitisadvisedtocheckforthecorrectinstallationofthe
unitandforthecorrectconnectionoftheaccessories.
ProblemsProbableCause Solution
Theequipmentdoesn't
switchon.
Interruptionorabsenceofthe
mainfeeding.
Verifytheconnectionofthemain
cable.
Verifythefusesandreplacethem,
wherenecessary,withnewonesof
theproprietype.
AlarmOCalwaysactive
(onlyforDIATERMO80)
Interruptionorlackofcontact
ontheneutralelectrodecircuit.
Checktheconnectionofthecable
totheneutralelectrode.
Replacethecableofconnectionof
theneutralelectrode.
Theunitdoesn't
respondtothe
commandofactivation
Breakdownofthepedal.‐
Wrongconnectionofthepedal.
Replacethepedal.
Verifytheconnectionofthepedal.
ErrorCode91Currentdeliverycontrol
activatedduringswitchingon.
Disconnectthepedalandswitchon
theunitagain.
ErrorCode92Errorinthemanagementboard. CallforService.
ErrorCode93Errorinthemanagementboard. CallforService.
GB‐24
MA391b_EN
Instruction’sManual
Toll.DescrizioneDIATERMO
50 80
PatientcircuitFF
DutyCycle(action/pause)inseconds 10/30 10/30
Outputpowercontrolfootswitch footswitch
Defibrillationproof  
Equipotentialbinding  
ABScabinet 
=PRESENT =NOTPRESENT
DIATERMO5080
GIMASpA
EN‐23
MA391b_EN
Instruction’sManualManualed’Istruzioni
DEUTSCHPORTUGUES FRANCOIS ESPANOL ENGLISH ITALIANO
TECHNICALCHARACTERISTICS
Toll.DescrizioneDIATERMO
50 80
Electrosurgicalunitcode GMA10100.051 GMA10100.081
±0%Minimumpresectablepower 0 0
Levelstep1 1
Digitalleveldisplay  
±20%MaximumoutputpowerCUT(W) 50→40080→400Ω
±20%MaximumoutputpowerCUT1(W) 45→400
±20%MaximumoutputpowerCUT2(W) 40→400
±20%MaximumoutputpowerBLEND(W) 60→400Ω
±20%MaximumoutputpowerCOAG(W) 40→40050→400Ω
±20%MaximumoutputpowerMICRO(W) 20→600Ω
±5%ModulationfactorCUT Pure100% Pure100%
±5%ModulationfactorCUT1(@10kHz) Mod.90%
±5%ModulationfactorCUT2(@10kHz) Mod.80%
±5%ModulationfactorBLEND(@10kHz) Mod.70%
±5%ModulationfactorCOAG(@10kHz) Mod.60% Mod.50%
±5%ModulationfactorMICRO(@10kHz) Mod.50%
0.1+0.2CrestFactorCUT1.5 1.5
±0.3CrestFactorCUT11.8
±0.3CrestFactorCUT22.1
±0.3CrestFactorBLEND 1.9
±0.3CrestFactorCOAG 2.3 2.2
±0.3CrestFactorMICRO 2.2
±10%Workingfrequency 600kHz 700kHz
±15%MaximumoutputvoltageCUT(Vpp) 1000 1000
±15%MaximumoutputvoltageCUT1(Vpp) 1000
±15%MaximumoutputvoltageCUT2(Vpp) 1000
±15%MaximumoutputvoltageBLEND(Vpp) 1000
±15%MaximumoutputvoltageCOAG(Vpp) 1000 1000
±15%MaximumoutputvoltageMICRO(Vpp) 900
±0.5WeightKg2.5 2.5
±10SizeWxHxDmm190x85x239 190x85x239
±5%Selectablepower(Vac) 115
23
0
115
23
0
±1%Mainsfrequency(Hz) 5060 5060
Fuses(230Vac)5x20typeTIMED 2xT1A 2xT2A
Fuses(115Vac)5x20typeTIMED 2xT2A 2xT4A
±10%Electricalinputpower(VA) 200 230
±10%Electricalinputcurrent(A)230Vac 0.9 1
±10%Electricalinputcurrent(A)115Vac 1.8 2
Selfcheck 
Splitornotsplitpatientplateallowed
Lastworkingconditionstoring  
ElectricalClass(EN606011) ICF ICF
MDD93/42/ECClass IIbIIb
EN55011(CISPR11)Class(Class/Group)2/B 2/B
GB‐22
MA391b_EN
Instruction’sManual
BackPanel
1Fusesholder/Voltageselector 2PowerOnOffswitch
3Mainsvoltageconnector 4Equipotentialconnector
PowerSupplyModuleandVoltageSelector
Powersupplymoduleistheconnectionpointofmainsvoltagefeedingtotheunit.This
moduleisprovidedwithlinefusesandthevoltageselector.
WARNING:beforeswitchontheunit,operatorhastoverifythatrequestedmains
voltagecorrespondstothevoltageavailablefromtheelectricalnet.(seechapter
INSTALLATION).
PowerOnOffSwitch
ThePOWERON/OFFmechanicalswitchisusedtocontrolpowertotheequipment.To
powertheequipment,presstheswitchinthedirectionofthe1.Whentheequipment
ispoweredthefrontpanelwillilluminate.Pressingtheswitchinthe0directionwillcut
powertotheequipment,thisoperationallowsittobeusedasanemergencystop
switch,intheeventofanyfault.
DIATERMO5080
GIMASpA
EN‐21
MA391b_EN
Instruction’sManualManualed’Istruzioni
DEUTSCHPORTUGUES FRANCOIS ESPANOL ENGLISH ITALIANO
AdjustmentoftheAcousticSignalLevel
Tomodifytheemissionacousticsignalitisnecessarytofollowthoseindications:
1. SwitchontheunitthroughthemainsswitchwhiletheCUTpushbuttonis
maintainedpressed.
2. Whentheunithasfinishedtocheckinternalparameters,onthedisplayappears
themessage S +valueofthepresetlevel(exampleS3).Now,theCUT
pushbuttoncanbereleased.
3. Throughtheknobitispossiblevaryingtheemissionacousticlevel.Duringthe
variationthesoundemittedbytheunitcorrespondstothepresetlevel.
4. PresstheCUTpushbuttontoconfirmthelevel.
LevelSoundemissionuntil1mdistance
fromthefrontalpanel
S155dBA
S260dBA
S365dBA
S470dBA
S575dBA
Connectors
NeutralElectrodeConnector
Thisisthepointofconnectionoftheneutralelectrode.
HandleConnector
Thisisthepointofconnectionofelectrodehandle.
FootswitchConnector
Ontheleftpartofthefrontpanelitisfootswitchconnector.
GB‐20
MA391b_EN
Instruction’sManual
DIATERMO80
CutCurrent(CUT)
Thebestcurrentforthecutisthepuresinusoidalwavewithoutmodulationthat
meanswithdutycycle100%.Suchcurrent,properforcutwithoutcoagulation.
CoagulatedCutCurrent(BLEND)
Thecoagulatedcutcurrent(BLEND)itissuitedforcoagulatedcutwhenadeep
coagulationtogetherthecutisdesired.Withthisblending,acurrentsuitedforcut
coagulatedinabsenceofescharandcarbonizationisobtained.
(OnlyforDIATERMO80)
CoagulationCurrent(COAG)
ThemodulatedcurrentCOAGitischaracterizedbygoodpropertyofsurface
coagulationbehavingatthetimeitprobableproductionofescharandpartial
carbonizationofthetissue.Theadvantageofthistypeofcoagulationresidesin
therapiditywithwhichtheeffectisgotten.

MicroCoagulationCurrent(MICRO)
ModulatedcurrentMICROissuitableforlittlebloodvesselcoagulation.The
coagulationprocessismorecheckedandexactinthiscase.
(OnlyforDIATERMO80)
SignalingofExcessiveImpedanceintheCircuitofNeutral
Electrode(OC)
OnlyforDIATERMO80.Forthemeaningofthiswarningsignalpleaserefertothe
previousdescriptionoftheneutralelectrodecircuit.
DIATERMO5080
GIMASpA
EN‐19
MA391b_EN
Instruction’sManualManualed’Istruzioni
DEUTSCHPORTUGUES FRANCOIS ESPANOL ENGLISH ITALIANO
Inordertoreducetheacousticpollution,thesoundalarmispresentonlywhenpressed
thefootswitch.
Ifasingleplateelectrodesusewatchedonlytheconnectionoftheneutralelectrode
platetotheunit.
PreselectingoftheDeliverableCurrent
Thedeliverablecurrentforthesurgicaloperationscanhavepreselectedthroughpush
buttonfor:
DIATERMO50
CutCurrent(CUT)
Thebestcurrentforthecutisthepuresinusoidalwavewithoutmodulationthat
meanswithdutycycle100%.Suchcurrent,properforcutwithoutcoagulation.
CoagulatedCutCurrent1(CUT1)
Thecoagulatedcutcurrent(CUT1)itissuitedforcoagulatedcutwhenamedium
coagulationtogetherthecutisdesired.
(OnlyforDIATERMO50)
CoagulatedCutCurrent2(CUT2)
Thecoagulatedcutcurrent(CUT2)itissuitedforcoagulatedcutwhenamore
coagulationtogetherthecutisdesired.
(OnlyforDIATERMO50)
CoagulationCurrent(COAG)
ThemodulatedcurrentCOAGitischaracterizedbygoodpropertyofsurface
coagulationbehavingatthetimeitprobableproductionofescharand
partialcarbonizationofthetissue.Theadvantageofthistypeofcoagulation
residesintherapiditywithwhichtheeffectisgotten.
GB‐18
MA391b_EN
Instruction’sManual
FrontalPanelDIATERMO80
1Levelcontrol
2Levelindications
3SelectionkeyandlightforCUTfunction
4SelectionkeyandlightforBLENDfunction
5SelectionkeyandlightforCOAGfunction
6SelectionkeyandlightforMICROfunction
7OCAlarm indicatorforexcessiveimpedanceintheneutralelectrodecircuit
8Connectorforneutralelectrodeconnection
9Handleconnectorforactiveelectrodeholder
10Footswitchconnector
OperationMode
SwitchOn
Whenswitchedontheelectrosurgicalunitperformsautomaticallyatesttoestablish
thecorrectoperationofitselfandoftheconnectedaccessoriesaswell.Incaseanomaly
isfounditisshowncodedaccordingtothechartcodesbroughtinthechapter
MAINTENANCE.Attheendofthecontroltheequipmentrestoreslastuseoperational
conditions.
DIATERMO80NeutralElectrode’sCircuit
OnlyfortheDIATERMO80,theneutralelectrodeiscontinuallywatchedbyaspecial
circuitthatpreventsdangerofburnstothepatientduethelossofcontactbetweenthe
neutralelectrodeandthepatientskin,ifsplitelectrodeisused.Iftheimpedancevalue
ofthepatientcircuitismorethan200ohmthevalueisnotaccepted,inthiscasethe
OCindicatorlightflashingandiftheoutputcircuitisactivatednopoweroutandthere
isasoundalarm.
DIATERMO5080
GIMASpA
EN‐17
MA391b_EN
Instruction’sManualManualed’Istruzioni
DEUTSCHPORTUGUES FRANCOIS ESPANOL ENGLISH ITALIANO
MeaningofGraphicsSymbols
ThemeaningofthegraphicsymbolsprintedonDIATERMO’scabinetisthefollowing:
1‐ FloatingPatient'splate:neitheratlowfrequencynorathighfrequencyearth
connected.
2‐TheequipmentisCFclass,protectedagainstCardiacDefibrillatordischarge.
3‐NotIonizingRadiationemitted.
4‐CorrespondingtotheDirectiveMedicalDevice93/42/EC(2007/47/EC).
5‐ Theproductmustn’tbethrewinthecontainersforurbanwastesbutitmustbe
swallowedbyaseparatepicking
6‐Manufacturer
7‐SerialNumber
8‐Followinstructionsforuse
1 2 3 4 5 6 7 8
FrontalPanelDIATERMO50
1Levelcontrol
2Levelindications
3SelectionkeyandlightforCUTfunction
4SelectionkeyandlightforCUT1function
5SelectionkeyandlightforCUT2function
6SelectionkeyandlightforCOAGfunction
7Connectorforneutralelectrodeconnection
8Handleconnectorforactiveelectrodeholder
9Footswitchconnector
GB‐16
MA391b_EN
Instruction’sManual
Beforeusingtheunit,itisnecessaryconnectthecabletothepatientplate,and
theseconnectedtounit.Theneutralelectrodemustapplytopatient(seeSafety
chapter).
PerilDIATERMO80Elettrodineutrimonopartitiebipartitipossonoessere
utilizzati.Conl’unitàaccesa,seilvaloredell’impedenzalettodall’apparecchiaturaè
accettabile,l'indicatoreluminosoOCcesseràdilampeggiare.
All'accensione,effettuataattraversol’interruttorepostosulretronelmodulodi
alimentazione,l'apparecchiaturadopoavereseguitouncontrollodeiparametri
internisaràimpostataconlafunzioneeilivellidipotenzautilizzatiall’ultima
accensione(allaprimaaccensioneilivellisaranno00).
DIATERMO50‐80typicalconfiguration
CONNECTORANDCONTROLS
Labelonthebottomofunit
TherequirementsforthesafetyofH.F.surgicalequipmentaskdataandgraphic
symbolsmustbeprintedonthecabinetoronatleastoneofthepanelsofgenerator
unittodefineitsfeaturesandoverseeitsconditionofwork.
Manufacturer’sIdentificationData
DIATERMO50andDIATERMO80HFelectrosurgicalunitaredesigned,manufactured
andtestedbytheLEDSpAinitsownlaboratoriesinAprilia(LT)Italy.
DIATERMO5080
GIMASpA
EN‐15
MA391b_EN
Instruction’sManualManualed’Istruzioni
DEUTSCHPORTUGUES FRANCOIS ESPANOL ENGLISH ITALIANO
INSTALLATION
Inspecttheunitfordamagesduringtransport.Theclaimsforpossibledamageswill
beacceptedonlyincasetheyareimmediatelycommunicatedtothecarrier;the
damagesthatarefoundmustbewrittendownandpresentedtoLEDSpAorto
yourownretailer.IftheunitisreturnedtotheLEDSpAortoyourownretailer,itis
necessarytousetheoriginalequipment’spackageoranotherequivalentone,to
guaranteethesafetyduringthetransport.
Unpacktheequipmentandcarefullystudythedocumentationandoperating
instructionsupplied.Mainsvoltage,indicatedabovetheinlet,mustagreewiththe
localmainsvoltage(mainsvoltagefrequency:5060Hz).Thecorrectvoltage(see
above)settingisselectedasshowninfig.E.Insertthecorrectfusesinthemodule
referringtothevaluewrittenonthelabel.
Thepredispositionofthecorrectmainsvoltageisperformedinthefollowingway:
(AB)Extractthefuseholderdrawerfromthepowermodule.
(C)Insertthefusesmakingreferencetothefollowingchart:
DIATERMO50
MainsVoltage 110120V DelayedFuse2xT2A/5x20mm
MainsVoltage220240VDelayedFuse2xT1A/5x20mm
DIATERMO80
MainsVoltage 110120V DelayedFuse2xT4A/5x20mm
MainsVoltage220240VDelayedFuse2xT2A/5x20mm
(D)Extractandrotatethedetachablepartinwaytoreadthecorrectvoltagein
the(E)windowreinsertthefuseholderinthemodule.
Connectmainscabletoamainsoutlethavinggoodhearthconnection.
OPERATIONOFTHEEQUIPMENTWITHOUTEARTHCONNECTIONISFORBIDDEN.
Theunitmustbeinstalledonalevelsurface,withdimension,atleast,
correspondenttothoseofthebaseoftheunititself.Aroundtheunitmustbelefta
spaceof25cm,atleast.
Connectthemainscabletothemainssocketontherearpaneloftheunit.
Connect,ifrequest,theequipotentialbindingpostlocatedattheleftoftheunit’s
backpaneltoeventualequipotentialsocketoftheplant.
Connectthesinglefootswitchtotheconnectoronthefrontpanel.
Connecthandleonthebuckleindicated“ACTIVE”.
Letunitworkindryenvironmentonly.Anyverifiedcondensatemustbelet
evaporatebeforeputtinginoperationtheunit.Don'texceedthetemperature
environmentortheallowedmoisture.
Conditionenvironments:
Temperature:10/40°C
Relativemoisture:30/75%
Pressure:70/106kPa
GB‐14
MA391b_EN
Instruction’sManual
CorrectPositionofNeutralElectrode
Theuseoftheneutralelectrode(orpatientplatefortheleakageofcurrent)is
necessaryinthemonopolartechnique,becauseitallowsthe“return”ofthecuttingor
coagulationcurrenttothescalpel.Thetypesoftheneutralelectrodearetwo:
neutralelectrodebysinglesurface (withjointcables)wherethereisnotacheckonthe
contactbetweenneutralelectrodeandpatient.
neutralelectrodebytwosurfaces(withdividedcables)wherethereisacheckonthe
contactbetweenneutralelectrodeandpatient.OnlyforDIATERMO80.
Keepattentiononthecorrectpositionofthepatientplatetoavoidburnsandother
risksforthepatient,werecommendedregardtothisbythefollowinginformation.
(CORRECTapplication)
InthispictureitisshowntheCORREC
T
positionoftheneutralelectrodebythetwo
surfaces.Thepatientplatemustbeplaced
perpendicularlytotheoperativefield.Itis
importanttoavoidthetransversalwayand
prefertheverticalordiagonalone,thereby
itisallowedauniformdistributionofthe
currentonalltwosurfacesandreducesthe
riskofburnsforthepatient.
(WRONGapplication)
Neutralelectrodeisoftenappliedinan
INCORRECTway,inparalleltotheoperative
field.Sothecurrentdistributionisnot
uniformonthetwosurfaces.
Beforetoapplytheneutralelectrode,cleanandeliminateanyexternalsubstancesfrom
itssurface.
Donotapplytheneutralelectrodeoncicatix,bonyprotrusionornearprosthesisor
monitoringelectrodes.Butapplyitonsprinkledtissues,suchasmusclesandnearthe
operativesite.Ifyouuseadisposableneutralelectroderespectthedateofuse,ifyou
useanotdisposableneutralelectrodemakesurethatthefixingsystemsguarantee
stability.
Itisveryimportantthattheneutralelectrodeisfirmlyappliedonitsentiresurfaceto
avoidburns.Whentheneutralelectrodeispartiallytakenofffromthepatient,the
currentdensityontheremainingappliedpartishigher.Becausethedensityofthe
currentflowundertheneutralelectrodeisnotuniform,itverifiesanotuniform
heating,especiallynearthebordersoftheneutralelectrode.
RodNeutralElectrode
OptionalRodneutralelectrodemustbeheld
solidinpatient’shand.
DIATERMO5080
GIMASpA
EN‐13
MA391b_EN
Instruction’sManualManualed’Istruzioni
DEUTSCHPORTUGUES FRANCOIS ESPANOL ENGLISH ITALIANO
Donotreduceordisabletheaudiblesignalwarningtheactivationofthegenerator.
Afunctioningactivationsignalcanminimizeorpreventpatientorstaffinjuryinthe
eventofaccidentalactivation.
Avoidverifyingthefunctioningoftheunitbyshortingtheactiveelectrodewiththe
referenceoneortheactiveelectrodewithmetallicparts.
Ifnecessaryuseasmokeplumeextractionsystem.
WARNING:Whentheelectrosurgicalunitisusedinoperatingroomsitisnecessaryto
justusewaterprooffootswitches(REF00302.00Waterproofpedal)
SafetyforthePatient
DuringtheHFelectrosurgicaloperationsthepatientisaconductorofelectricalvoltage
againstearthpotential.Soifthereisacontactbetweenpatientandelectrical
conductiveobjects(metal,wetclothes,etc..),inthecontact’spointcouldbeelectrical
currentthatcausesthermicalnecrosis.Soitisrecommendedtoinspecttheequipment
anditsaccessoriesbeforeusingandtorespectallsafetyrules.
CorrectPositionofthePatient
Itisimportanttoavoidanyintentionoraccidentalcontactbetweenpatientand
groundedmetallicpartsandtomakesurethat:
Thepatientisnotincontactwithmetallicparts(operativetable,supports..).
Theflexibletubesoftherespiratordonottouchthebodyofthepatient.
Ontheoperativetablewithgroundedconnectiontherearealwayscoatingsthat
allowdischargingtheelectrostaticcharges.
Thepatientisonathickbasictissuewithinsulatingproperties,coveredbya
sufficientnumberofnets.
Thepatientisnotincontactwithnetsorwetmattress.
Theeventualorganicsecretionsandthecleaningandotherliquidsdonotwet
thenets.
Therearenotliquidunderthepatient.
Urinarysecretionsareeliminatingbythecatheters.
Thebodyzonescharacterizedbyahighersweating,theextremitiesindirect
contactwithtrunkorthepointsofskinskincontactaredriedbythenets
interposition(arm/trunk,leg/leg,breast,skinfolds,etc.).
Allconductiveandgroundedsupports,stirrups,arecorrectlyinsulated.
Controltheanestheticsquantitytoavoidagreatsweating.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34

Gima 30627 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI