Sorel LHCC S45 24V Owner's manual

Category
Heat pumps
Type
Owner's manual
Heating Controller LHCC
Heating circuit controller for heating and cooling systems
Installation and operating instructions
Read carefully before installation, commissioning and operation
CONTENT
Safety Instructions 5
EU-Conformity 5
General instructions 5
Explanation of Symbols 5
Changes to the Unit 6
Warranty and Liability 6
Disposal and Pollutants 6
Description LHCC 7
Specifications 7
About the Controller 8
Scope of Supply 8
Hydraulic Variants 9
Wall Installation 11
Installation 12
Electrical Terminals 12
Additional Information 13
External relay at signal output V(X) (0-10V / PWM) 13
Electrical Terminals 13
Electrical Connection 23
Installing the Temperature Sensors 23
Temperature Resistance Table for Pt1000 Sensors 23
Combining multiple SOREL products 23
CAN bus 23
°CALEON Room Controllers 24
RC21 Room thermostat with remote control 26
Operation 28
Display and Input 28
Commissioning help 29
1. Measurement values 29
2. Statistics 30
Today 30
28 days 30
Operating hours 30
Heat quantity 30
Graphic overview 30
Notifications 30
Reset / Clear 30
3. Periods 31
Time & Date 31
Daylight saving time 31
Heating Circuit (Day) 31
Heating Circuit Comfort 31
DHW enable 31
DHW comfort 31
4. Operating mode 32
Manual 32
Mode Circuit (X) 32
5. Settings 33
Heating Circuit (X) 33
Operating mode 33
Season switch 34
S/W Day 34
S/W Night 34
Curve 34
Day Correction 34
Night Correction 34
Comfort Temperature Boost 35
Min. Flow 35
Max. Flow 35
Reference/Actual - 35
Reference/Actual + 35
Variant 35
Heating circuit off 35
Room hysteresis 35
Buffer sensor 36
Insulation factor 36
Overload protection 36
Min. Flow cooling 36
Max. flow cooling 36
Dew Point protection 36
Dew point correction 36
Room Controller Heating Circuit (X) 36
Room Controller 38
Smart grid 1/ PV contact 38
Smart grid 2 38
Settings Domestic Hot Water (DHW) 38
Operating mode 38
Hot water minimum 38
DHW reference 38
DHW comfort 39
DHW hysteresis 39
Buffer DHW load 39
DHW priority 39
DHW sensor 39
Smart grid 1/ PV contact 39
6. Protective Functions 39
Seizing Protection 39
Frost Protection 39
Discharge Protection 40
Dew point correction 40
Pressure Monitoring 40
RPS1 / RPS2 40
RPS Min 40
RPS Max 40
Protective functions for Solar 40
System protection 40
Collector protection 40
Recooling 40
Frost Protection 41
Collector alarm 41
7. Special Functions 41
Program selection 41
Pump settings V(X) 41
Signal type 41
Profile 41
Output Signal 41
PWM / 0-10V off 41
PWM / 0-10V on 41
PWM / 0-10V max. 42
Show signal 42
Speed control 42
Variant 42
Purging time 42
Sweep time 42
Max. Speed 42
Min. Speed 42
Setpoint 42
Sensor Calibration 42
Relay functions 43
Heat quantity 43
Flow temperature sensor (X) 43
Return flow sensor 43
Glycol type 43
Glycol percentage 43
Flow rate supply flow (X) 43
Offset ∆T 43
VFS (X) 43
VFS - Position 44
Reference sensor 44
Commissioning 44
Factory Settings 44
Eco Display Mode 44
Network 44
Access Control 44
Ethernet 44
Datalogger Version 45
CAN bus ID 45
Sensor send interval 45
8. Menu Lock 46
9. Service Values 46
10. Language 46
Function overview 47
Mixer 47
Direction 47
Mixer turn time 47
Mixer off factor 47
Mixer increase 47
Mixer run time 47
Signal type 47
Cooling valve Heating circuit 1/ Heating circuit 2 47
Heating Circuit 2 47
Free Cooling 47
RFI mixer 48
Operating mode 48
Reference flow sensor 48
Tref: 48
Return flow sensor: 48
Storage sensor: 48
Direction: 48
Min off time: 48
On-time: 48
Off factor: 48
Increase: 48
Max one direction: 48
Signal type 48
Difference 48
Δ T Difference 49
DF-Source 49
Tmin Source 49
DF-Drain 49
Tmax Drain 49
Heat transfer 49
Δ T Heat transfer 49
HT Tmax 49
HT Tmin 49
Source 49
Drain 49
Thermostat 49
DHW request 50
Heating Circuit request 50
Tset 50
Hysteresis 50
Energy Saving Mode 50
Delay 50
Thermostat sensor 1 50
Thermostat sensor 2 50
Thermostat enable 50
Electric heating rod (auxiliary heating) 50
DHW request 50
HC request 50
TH Set 50
Delay 50
Hysteresis 51
Eco mode 51
Sensor 1 51
Sensor 2 51
Electric heating rod approval times 51
Anti-legionella heating rot 51
Dissipation (Cooling) 51
Tset 51
Cooling sensor 51
Delay 51
Season switch 51
Off hysteresis 51
On hysteresis 52
Cool storage 52
Buffer sensor 52
Solid fuel boiler 52
Solid fuel boiler Tmax 52
Solid fuel boiler Tmin 52
ΔT Solid fuel boiler 52
Boiler sensor of this function 52
Storage sensor 52
Solar 52
Tmin Collector 52
ΔT Solar 53
Tmax Storage 53
Starting aid 53
Purging time 53
Increase 53
Protective Functions 53
Collector 53
Solar storage 53
Solar bypass 53
Variant 53
Bypass sensor 53
Booster Pump 54
Charge time 54
Zone valve 54
Tmax storage 2 54
Solar storage 2 54
Heat exchanger 54
Heat exchanger sensor 54
Burner 54
DHW request 54
Heating Circuit request 54
Burner sensor 54
Delay 54
Burner offset 54
Eco mode (during solar charge) 54
Tmax 55
Boiler base temperature 55
Base hysteresis 55
Enable 55
Anti Legionella 55
Boiler pump 55
Boiler pump Tmin 55
Compressor 55
DHW request 55
HC request 55
Cooling request 55
Eco mode (during solar charge) 55
Heating circuit offset 55
Min heat pump runtime 56
Heat pump idle time 56
Heat pump delay 56
Storage charge pump (SLP) overshoot 56
Bivalent temperature 56
Min. outdoor temperature 56
Periods 56
Anti Legionella 56
Loading pump 56
Storage charge pump (SLP) overshoot 56
Glycol pump 56
Gylcol pump lag 56
Return flow increase 56
Return flow increase Tmin 57
Return flow increase Tmax 57
ΔT return flow 57
Return flow sensor 57
Storage sensor 57
Domestic hot water valve 57
Circulation 57
Tmin 57
Hysteresis 57
Circulation sensor 57
Circulation pause time 57
Purging time 57
Circulations periods 57
Anti Legionella 57
Error Messages 58
Error message 58
Pressure monitor 58
Pressure monitor 58
RPS-Type 58
RPS Max 58
RPS Min 58
Dehumidifier 58
Operating mode 58
Reference humidity 58
Hysteresis 58
Dehumidifier periods 59
Parallel operation 59
Parallel operation 59
Parallel to 59
Delay 59
Follow-up time 59
Remote 59
Relay status 59
Title 59
Always on 59
Anti Legionella 59
Malfunctions/Maintenance 61
Tips 62
Support Guideline 62
Appendix 62
Signal 62
Output Signal 62
PWM / 0-10V off 62
PWM / 0-10V on 62
PWM / 0-10V max. 63
Speed when „On“ 63
Example for signal settings 63
Technical data PWM and 0-10V 63
Show signal 63
Final Declaration 64
Safety Instructions
EU-Conformity
By affixing the CE mark to the unit the manufacturer declares that theLHCC conforms to the following relevant safety regulations:
lEU low voltage directive 2014/35/EU
lEU electromagnetic compatibility directive 2014/30/EU
conforms. Conformity has been verified and the corresponding documentation and the EU declaration of conformity are kept on file by the
manufacturer.
General instructions
Please read carefully!
These installation and operating instructions contain basic instructions and important information regarding safety, installation, com-
missioning, maintenance and the optimal use of the unit. Therefore these instructions must be read and understood completely by the
installation technician/specialist and by the system user before installation, commissioning and operation of the unit.
This unit is an automatic, electrical Heating circuit controller for heating and cooling systems for/inHeating system and similar applications.
Install the device only in dry rooms and under environmental conditions as described under "Technical Data".
The valid accident prevention regulations, VDE regulations, the regulations of the local power utility, the applicable DIN-EN standards and
the installation and operating instruction of the additional system components must also be observed.
Under no circumstances does the unit replace any safety devices to be provided by the customer!
Installation, electrical connection, commissioning and maintenance of the device may only be carried out by an appropriately trained spe-
cialist. Users: Make sure that the specialist gives you detailed information on the function and operation of the unit. Always keep these
instructions in the vicinity of the unit.
The manufacturer does not take over any liability for damage caused through improper usage or non-compliance of this manual!
Explanation of Symbols
Danger
Failure to observe these instructions can result in electrocution.
Danger
Failure to observe these instructions can result in serious damage to health such as scalding or life-threatening injuries.
Caution
Failure to observe these instructions can result in destruction of the unit or the system, or environmental damage.
Caution
Information which is especially importation for the function and optimal use of the unit and the system.
5
Changes to the Unit
lChanges, additions to or conversion of the unit are not permitted without written permission from the manufacturer.
lIt is likewise forbidden to install additional components that have not been tested together with the unit.
lIf it becomes clear that safe operation of the unit is no longer possible, for example because of damage to the housing, turn the Unit off
immediately.
lAny parts of the unit or accessories that are not in perfect condition must be exchanged immediately.
lUse only original spare parts and accessories from the manufacturer.
lMarkings made on the unit at the factory must not be altered, removed or made illegible.
lOnly the settings described in these instructions may be set using the Unit.
Changes to the unit can compromise the safety and function of the unit or the entire system.
Warranty and Liability
The unit has been manufactured and tested with regard to high quality and safety requirements. The unit is subject to the statutory guarantee
period of two years from the date of sale. The warranty and liability shall not include, however, any injury to persons or material damage that
is attributable to one or more of the following causes:
lFailure to observe these installation and operating instructions.
lImproper installation, commissioning, maintenance and operation.
lImproperly executed repairs.
lUnauthorised structural changes to the unit.
lUse of the device for other than its intended purpose.
lOperation above or below the limit values listed in the ‚Specifi cations‘ section.
lForce majeure.
Disposal and Pollutants
The unit conforms to the European RoHS 2011/65/EU for 2011/65/EUthe restriction of the use of certain hazardous substances in electrical
and electronic equipment.
Under no circumstances may the device be disposed of with the normal household waste. Dispose of the unit only at appropriate
collection points or ship it back to the seller or manufacturer.
6
Description LHCC
Specifications
Model LHCC Heating Controller
Temperature controller class VI
Energy efficiency 4%; When operating at min. 3 ° CALEONs or RC20
a energy efficiency of 5% is achieved
Standby loss 0,5 W
Request type heater On / off operation or modulating
Electrical specifications:
Power supply 100 - 240VAC,50 - 60 Hz
Power consumption / standby 0.5 - 2.5 W/0,5 W
Total switched power 2 A
Switched power per relay 460VA
Internal fuse 1 2 A slow 250V
Protection Class IP40
Protection class / overvoltage category II / II
Inputs/Outputs Measuring range
Sensor inputs 6 Pt1000 -40 °C ... 300 °C
Sensor inputs VFS 2Grundfos Direct Sensor 0°C-100°C (-25°C /120°C short term)
Outputs mechanical relay 4
of relay potential free R4 1
Mechanical relay R1 - R4 460VA for AC1 / 460VA for AC3
0-10V/PWM output V1 - V2 for 10 k Ω working resistance 1 kHz, level 10 V
+ Terminal/
Voltage output
+Max. load by external devices 24V/6W (e.g. power supply of 3
°CALEON room controllers)
Max. cable length
VFS/RPS sensors < 3 m
CAN < 3 m; at >= 3 m, a shielded twisted pair cable must be used. Isolate
shielding and connect it to the protective conductor of only one of the
devices. Max. cable length of the complete system 200 m.
0-10V/PWM < 3 m
24 VDC < 30 m
mechanical relay < 10 m
Interface
Fieldbus CAN
Permissible Ambient Conditions
for controller operation 0 °C - 40 °C, max. 85 % rel. humidity at 25 °C
for transport/storage 0 °C - 60 °C, no moisture condensation permitted
Other Specifications and Dimensions
Housing Design 2-part, ABS plastic
Installation Methods Wall installation, optionally panel installation
Overall dimensions 163 mm x 110 mm x 52 mm
Aperture installation dimensions 157 mm x 106 mm x 31 mm
Display Fully graphical display, 128 x 64 dots
Light diode multicolour
Real Time Clock RTC with 24 hour power reserve
Operation 4 entry keys
7
About the Controller
The Heating circuit controller for heating and cooling systems LHCC facilitates efficient use and function control of your Heating system pos-
sible while its handling is intuitive. After every input step the suitable functions are matched to the keys and explained in a text above. In the
menu 'measurement values and settings' are help text and graphics in addition to key words.
The LHCC can be used for the various system variants.
Important characteristics of the LHCC are:
lDepiction of graphics and texts using a lit display.
lSimple viewing of the current measurement values.
lStatistics and system monitoring by means of statistical graphics
lExtensive setting menus with explanations.
lMenu block can be activated to prevent unintentional setting changes.
lResetting to previously selected values or factory settings.
Scope of Supply
lHeating ControllerLHCC
l3 screws 3,5 x 35 mm and 3 plugs 6 mm for wall installation.
lLHCC Installation and operating instructions
Optionally contained depending on design/order:
lOutdoor sensor: TA55 (87005)
lEthernet connection: optionally possible via datalogger (77701)
lPt1000 temperature sensor: e.g. TR / S2 (81220)
lRoom Controller: °CALEON (70001) / °CALEON Clima (70002)
lCAN Bus Accessories: e.g. CAN Connection kit 1.00m (89211)
8
Hydraulic Variants
The following illustrations should be regarded only as schematic representations of the respective hydraulic systems and do not claim to be complete. Under no cir-
cumstances should the controller replace any safety devices. Depending on the specific application, additional system and safety components such as check
valves, non-return valves, safety temperature limiters, scalding protectors, etc., may be required.
Heating circuit and burner Mixed heating circuit Mixed PWM heating circuit
Mixed heating circuit and burner Mixed heating circuit, burner
and solar Mixed heating circuit and heat
pump
Mixed heating circuit, heat pump and
solar
mixed heating circuit and solid fuel
solid fuel boiler
Mixed heating circuit, heat pump
and cooling function
2 heating circuits, combined water
tank, DHW-valve and burner
Mixed heating circuit, unmixed heat-
ing circuit
and burner
Mixed heating circuit, DHW-valve
and burner
2 mixed PWM heating circuit Mixed PWM-Hc, DHW, solar, burner
and zone valve
Mixed heating circuit and
combination storage
9
Mixed PWM heating circuit and solid
fuel boiler
Mixed heating circuit, solid fuel boiler,
and burner
Mixed heating circuit, DHW and
Heat transfer
Mixed heating circuit, DHW and heat
transfer
Mixed PWM heating circuit, DHW, and
heat transfer
Mixed heating circuit, DHW,
heat transfer and burner
Mixed heating circuit, DHW, heat trans-
fer and heat pump
Mixed heating circuit with unmixed
heating circuit, solid fuel boiler
Heating circuit and burner
Mixed heating circuit and burner Heating circuit, burner and DHW load-
ing pump
Mixed PWM heating circuit, burner
and DHW loading pump
10
Wall Installation
1. Unscrew cover screw completely.
2. Carefully pull upper part of housing from lower part. During the
removal, the brackets are released as well.
3. Set upper part of housing aside. Do not touch the electronics.
4. Hold the lower part of the housing in the selected position and
mark the 3 mounting holes. Make sure that the wall surface is as
even as possible so that the housing does not become distorted
when screwed on.
5. Using a drill and size 6 bit, drill three holes at the points marked
on the wall and push in the plugs.
6. Insert the upper screw and screw it in lightly.
7. Fit the upper part of the housing and insert the other two screws.
8. Align the housing and tighten the three screws.
1. Open the terminal cover.
2. Strip lines a max. of 55 mm, assemble the strain reliefs, strip wire
ends 8-9 mm.
3. Open clamps with a fitting screwdriver and connect electrical sys-
tem to the controller.
4. Clip on the terminal cover again and close it with the screw.
5. Turn on mains supply and put the controller into operation.
If problems occur with the operation of the terminals, our video on our YouTube page can help you:
http://www.sorel.de/youtube
11
Installation
Electrical Terminals
Low voltages
max. 24 VAC / DC
Mains voltages
230 VAC 50 - 60 Hz
Terminal: Connection for:
- GND bridge on the lower ground terminal block
S1 Temperature Sensor 1
S2 Temperature Sensor 2
S3 Temperature Sensor 3
S4 Temperature Sensor 4
S5 Temperature Sensor 5
V1 0-10V / PWM signal output e.g. for controlling high-effi-
ciency pumps
V2 0-10V / PWM signal output e.g. for controlling high-effi-
ciency pumps
S6 Temperature Sensor 6 (outdoor)
+ Terminal/
Voltage out-
put
24V voltage output
Max. load by external devices 24V / 6W
The connection of the ground wire is made at the lower gray terminal
block.
Terminal: Connection for:
N Neutral conductor N
L Network outer conductor L
R1 Relays 1
R2 Relays 2
R3 Relays 3
R4| Relay 4 | (potential-free contact)
R4 Relay 4 (potential-free contact)
The neutral conductor N must be connected to the N terminal
block.
The PE protective conductor must be connected
to the PE metal terminal block!
For high-efficiency pumps with 0-10V / PWM sig-
nal input, the power can be provided (V1 /V2 par-
allel operation) over a free relay.
On the control board
VFS1 Grundfos Direct Sensor "Connection of PWM pumps"
PWM pumps are connected to the controller with 2 wires 1)
PWM Input (default: brown) 2) GND (default: blue). Some pumps
have a third wire (PWM Output Signal (default: black)). This is
not used for the connection!
VFS2 Grundfos Direct Sensor
CAN CAN bus connection (1=high,2=low)
CAN CAN bus connection (1=high,2=low)
12
Additional Information
External relay at signal output V(X) (0-10V / PWM)
With the help of an external relay (art. no. 77502), a 0-10V/PWM output
V(X) (V1, V2) can be used to obtain a switching capacity of 230 VAC (I)
or a potential-free change-over contact (II). The external relay is then
activated via the signal output (0V = "off" (0 VAC or open or closed), 10V
= "on" (230VAC or closed or open).
1. Connect external 0-10V relay to signal output, e.g. V1.
2. Assign additional function to signal V1. See " Relay functions " on
page 43
3. Disable the speed control for the corresponding 0-10V / PWM output
(Off). See " Variant " on page 42
Electrical Terminals
For high-efficiency pumps with 0-10V / PWM signal input, the power can be provided (V1 /V2 parallel operation) over a free
relay.
The connection of the ground wire is made at the lower gray terminal block. The neutral conductor N is connected to terminal
block N. The PE protective conductor must be connected to the PE metal terminal block!
Program 1 heating circuit and burner
Terminal: Connection: Terminal: Connection:
- GND N Neutral con-
ductor N
S2 Buffer sensor L Network outer
conductor L
S5 Flow sensor R1 Heating cir-
c.pump/ Cir-
culation pump
S6 Outdoor sensor R4| Burner
+24V 24V voltage output
Max. external devices 24V/6W
R4 Burner
13
Program 2 mixed heating circuit
Terminal: Connection: Terminal: Connection:
- GND N Neutral con-
ductor N
S2 Buffer sensor L Network outer
conductor L
S5 Flow sensor R1 Heating cir-
c.pump/ Cir-
culation pump
S6 Outdoor sensor R2 Mixer open
+24V 24V voltage output
Max. external devices 24V/6W
R3 Mixer close
Program 3 mixed PWM heating circuit
Terminal: Connection: Terminal: Connection:
- GND N Neutral con-
ductor N
S2 Buffer sensor L Network outer
conductor L
S5 Flow sensor R1 Heating cir-
c.pump/ Cir-
culation pump
V1 PWM Mixer (external power
supply)
S6 Outdoor sensor
+24V 24V voltage output
Max. external devices 24V/6W
Program 4 mixed heating circuit and burner
Terminal: Connection: Terminal: Connection:
- GND N Neutral con-
ductor N
S2 Buffer sensor L Network outer
conductor L
S5 Flow sensor R1 Heating cir-
c.pump/ Cir-
culation pump
S6 Outdoor sensor R2 Mixer open
+24V 24V voltage output
Max. external devices 24V/6W
R3 Mixer close
R4| Burner
R4 Burner
14
Program 5 mixed heating circuit, burner and solar
Terminal: Connection: Terminal: Connection:
- GND N Neutral conductor N
S1 Solar storage sensor L Network outer con-
ductor L
S2 Buffer sensor R1 Heating circ.pump/
Circulation pump
S4 Collector sensor R2 Mixer open
S5 Flow sensor R3 Mixer close
V1 Solar pump (external
power supply)
R4| Burner
S6 Outdoor sensor R4 Burner
+24V 24V voltage output
Max. external devices
24V/6W
Program 5 mixed heating circuit and heat pump
Terminal: Connection: Terminal: Connection:
- GND N Neutral con-
ductor N
S2 Buffer sensor L Network outer
conductor L
S5 Flow sensor R1 Heating cir-
c.pump/ Cir-
culation pump
S6 Outdoor sensor R2 Mixer open
+24V 24V voltage output
Max. external devices
24V/6W
R3 Mixer close
R4| Compressor
R4 Compressor
Program 7 mixed heating circuit, heat pump and solar
Terminal: Connection: Terminal: Connection:
- GND N Neutral conductor N
S1 Solar storage sensor L Network outer con-
ductor L
S2 Buffer sensor R1 Heating circ.pump/
Circulation pump
S4 Collector sensor R2 Mixer open
S5 Flow sensor R3 Mixer close
V1 Solar pump (external
power supply)
R4| Compressor
S6 Outdoor sensor R4 Compressor
+24V 24V voltage output
Max. external devices
24V/6W
15
Program 8 mixed heating circuit and solid fuel boiler
Terminal: Connection: Terminal: Connection:
- GND N Neutral con-
ductor N
S2 Buffer sensor L Network outer
conductor L
S4 Sensor solid fuel boiler R1 Pump
S5 Flow sensor R2 Mixer open
S6 Outdoor sensor R3 Mixer close
+24V 24V voltage output
Max. external devices 24V/6W
R4| Solid fuel boiler
R4 Solid fuel boiler
Program 9 mixed heating circuit, heat pump and cooling function
Terminal: Connection: Terminal: Connection:
- GND N Neutral conductor
N
S2 Buffer sensor L Network outer con-
ductor L
S4 Buffer sensor 2 R1 Heating circ.pump/
Circulation pump
S5 Flow sensor R2 Mixer open
V1 Season switch R3 Mixer close
S6 Outdoor sensor R4| Compressor
+24V 24V voltage output
Max. external devices 24V/6W
R4 Compressor
Program 10 2 heating circuits, combined storage, DHW valve and burner
Terminal: Connection: Terminal: Connection:
- GND N Neutral conductor
N
S2 Buffer sensor L Network outer con-
ductor L
S3 DHW sensor R1 Heating circ.pump/
Circulation pump
heating circuit 2
S4 Flow sensor heating circuit 2 R2 Heating circ.pump/
Circulation pump
heating circuit 1
S5 Flow sensor heating circuit 1 R3 DHW valve
S6 Outdoor sensor R4| Burner
+24V 24V voltage output
Max. external devices 24V/6W
R4 Burner
16
Program 11 mixed heating circuit, unmixed heating circuit and burner
Terminal: Connection: Terminal: Connection:
- GND N Neutral conductor
N
S2 Buffer sensor L Network outer con-
ductor L
S4 Flow sensor heating circuit 2 R1 Heating circ.pump/
Circulation pump
heating circuit 1
S5 Flow sensor heating circuit 1 R2 Mixer open
V1 Heating circ.pump/
Circulation pump heating cir-
cuit 2
R3 Mixer close
S6 Outdoor sensor R4| Burner
+24V 24V voltage output
Max. external devices 24V/6W
R4 Burner
Program 12 mixed heating circuits, DHW valve and burner
Terminal: Connection: Terminal: Connection:
- GND N Neutral conductor
N
S2 Buffer sensor L Network outer con-
ductor L
S3 DHW sensor R1 Heating cir-
c.pump/ Cir-
culation pump
S5 Flow sensor R2 Mixer open
V1 DHW valve (via external relay) R3 Mixer close
S6 Outdoor sensor R4| Burner
+24V 24V voltage output
Max. external devices 24V/6W
R4 Burner
Program 13 2 mixed PWM heating circuits
Terminal: Connection: Terminal: Connection:
- GND N Neutral conductor N
S2 Buffer sensor L Network outer con-
ductor L
S4 Flow sensor heating cir-
cuit 2
R1 Heating circ.pump/ Cir-
culation pump heating
circuit 2
S5 Flow sensor heating cir-
cuit 1
R2 Heating circ.pump/ Cir-
culation pump heating
circuit 1
V1 PWM mixer heating cir-
cuit 1 (external power sup-
ply)
V2 PWM mixer heating cir-
cuit 2 (external power sup-
ply)
S6 Outdoor sensor
+24V 24V voltage output
Max. external devices
24V/6W
17
Program 14 mixed PWM heating circuit, DHW, solar, burner and zone
valve
Terminal: Connection: Terminal: Connection:
- GND N Neutral conductor N
S1 Solar storage sensor L Network outer conductor
L
S2 Buffer sensor R1 Heating circ.pump/ Cir-
culation pump
S3 DHW sensor R2 Solar pump
S4 Collector sensor R3 DHW valve
S5 Flow sensor R4| burner
V1 PWM Mixer (external
power supply)
R4 burner
S6 Outdoor sensor
+24V 24V voltage output
Max. external devices
24V/6W
Program 15 mixed heating circuit, and combination storage
Terminal: Connection: Terminal: Connection:
- GND N Neutral conductor N
S2 Buffer sensor L Network outer con-
ductor L
S3 DHW sensor R1 Heating circ.pump/ Cir-
culation pump
S5 Flow sensor R2 Mixer open
S6 Outdoor sensor R3 Mixer close
+24V 24V voltage output
Max. external devices
24V/6W
R4| DHW-pump
R4 DHW-pump
Program 16 mixed PWM heating circuit and storage
Terminal: Connection: Terminal: Connection:
- GND N Neutral conductor N
S2 Buffer sensor L Network outer conductor
L
S3 DHW sensor R1 Heating circ.pump/ Cir-
culation pump
S5 Flow sensor R2 DHW-pump
V1 PWM mixer
S6 Outdoor sensor
+24V 24V voltage output
Max. external devices
24V/6W
18
Program 17 mixed heating circuit, storage and burner
Terminal: Connection: Terminal: Connection:
- GND N Neutral con-
ductor N
S2 Buffer sensor L Network outer
conductor L
S3 DHW sensor R1 Heating cir-
c.pump/ Cir-
culation pump
S5 Flow sensor R2 Mixer open
V1 DHW-pump R3 Mixer close
S6 Outdoor sensor R4| Burner
+24V 24V voltage output
Max. external devices 24V/6W
R4 Burner
Program 18 unmixed heating circuit, DHW and storage transfer
Terminal: Connection: Terminal: Connection:
- GND N Neutral con-
ductor N
S2 Buffer sensor L Network outer
conductor L
S3 DHW sensor R1 Heating cir-
c.pump/ Cir-
culation pump
S5 Flow sensor R2 DHW-pump
S6 Outdoor sensor
+24V 24V voltage output
Max. external devices 24V/6W
Program 19 mixed heating circuit, DHW and storage transfer
Terminal: Connection: Terminal: Connection:
- GND N Neutral con-
ductor N
S2 Buffer sensor L Network outer
conductor L
S3 DHW sensor R1 Heating cir-
c.pump/ Cir-
culation pump
S5 Flow sensor R2 Mixer open
S6 Outdoor sensor R3 Mixer close
+24V 24V voltage output
Max. external devices 24V/6W
R4| DHW-pump
R4 DHW-pump
19
Program 20 mixed PWM heating circuit, DHW and storage transfer
Terminal: Connection: Terminal: Connection:
- GND N Neutral con-
ductor N
S2 Buffer sensor L Network outer
conductor L
S3 DHW sensor R1 Heating cir-
c.pump/ Cir-
culation pump
S5 Flow sensor R2 DHW-pump
V1 PWM mixer
S6 Outdoor sensor
+24V 24V voltage output
Max. external devices 24V/6W
Program 21 mixed heating circuit, DHW, storage transfer and burner
Terminal: Connection: Terminal: Connection:
- GND N Neutral conductor
N
S2 Buffer sensor L Network outer con-
ductor L
S3 DHW sensor R1 Heating circ.pump/
Circulation pump
S5 Flow sensor R2 Mixer open
V1 DHW-pump R3 Mixer close
S6 Outdoor sensor R4| Burner
+24V 24V voltage output
Max. external devices 24V/6W
R4 Burner
Program 22 mixed heating circuit. DHW, storage transfer and heat pump
Terminal: Connection: Terminal: Connection:
- GND N Neutral conductor
N
S2 Buffer sensor L Network outer con-
ductor L
S3 DHW sensor R1 Heating circ.pump/
Circulation pump
S5 Flow sensor R2 Mixer open
V1 DHW-pump R3 Mixer close
S6 Outdoor sensor R4| Compressor
+24V 24V voltage output
Max. external devices 24V/6W
R4 Compressor
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Sorel LHCC S45 24V Owner's manual

Category
Heat pumps
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI