10
Low Water Level Warning;
WhenwaterlevelinthetankisbelowMin.,UFOConvectorstopshumidifying,then
warnstheuservisuallybyashing“HUMIDITYERR”and“drop”iconsonthe
screen,followinganaudiblewarningwitha“beep”soundfor2secondslong.
Inthiscase,youcanreactivatethehumidierbyfollowingthe3stepsdescribed
below;
•FillthetankwithwatertotheMax.level.
•Whentheapplianceisin“On”position,keeptouchingthe“Humidier”
buttonuntilalltherelatedwarningsdisappearfromthescreen.
•Touchthe“Humidier”buttonagaintoreactivatethefunction.
CAUTION!Donotactivatethehumidierifthetanklackswater.Whenactivated
withoutaddingwater,theappliancewilldetectthe“lowwaterlevel”andrepeat
thewarnings.Makesurethatthewaterlevelisabove“Min”beforerestartingthe
humidierfunction.
Cleaning:
Dependingonthecontentofwaterusedinthe“HumidierTank”,limeordirt
maybuildupontheresistanceorinsidethetank.SeeChapter5(Cleaningand
Maintenance)forcleaninginstructionsofthehumidiertank.
b. Setting the On-Off Timer (PRG Function)
UFOCONVECTORcanbeprogrammedtooperateatadenedtimeperiod.Sothat
itheatsonlyduringtheprogrammedtime.
Donotforgettosetthecorrecttimebeforeactivatingthisfunction.“PRG”function
operatesdependingonthetimeyouset.
CAUTION! UFOCONVECTORheatsonlyattheprogrammedtimeintervalswhen
“PRG”functionisactivated.Exceptthistimeinterval,itwillnotoperateevenifthe
roomtemperatureisbelowthesettemperature.
Touchthe“PRG”buttonfor4secondswhentheapplianceisin
“On”position.
PRG”and“ONTIME”iconsstartashingontheLCDdisplay.
Setthe‘on’timebytouchingthe“Arrow”buttons.Thesetting
speedcanbeincreasedbytouchingcontinuously.
Whenthe‘on’timeisset,touch“OK”buttontosaveit.
Then“TIMEOFF”iconstartsashingindicatingthatyou
shouldsetan‘off’time.Setthe‘off’timebyusingthe
“Arrow”buttons.
Saveitbytouchingthe“OK”button.
TEMP°C(orTEMP°F)willstartashingontheLCDscreen.
Adjustthedesiredroomtemperatureforthistimeinterval
byusingthe“Arrow”buttons.
Touchthe“OK”buttontonishtheprogramming.
“PRG”iconappearsonLCDscreenandtellsyouthattheapplianceisprogrammed
tooperateforthesettimeonly.
PRG
OK
OK
OK