Scholtes B 402TC/CS BNV F User guide

Type
User guide
B...
BB...
B.../CS
BB.../CS
Istruzioni per l'uso e l'installazione
Instructions for use and installation
Instructions pour l'emploi et l'installation
Gebrauchs- und Installationsanleitungen
Instructies voor het gebruik en het installeren
Piano di cottura
Hob
Plan de cuisson
Kochplatte
Kookplaat
33
33
3
BB 402TC - B 402TC
BB 10TC - B 10TC
BB 20 A - B 2 0A
BB 20 R - B 2 0R
BB 40 - B 4 0
B 2 0TCD CD R
B 40DCDR
B 40 TC - BB 4 0TC
A
C
B
I
G
D
H
A
B
D
BB
B
B
BB
B
BB
D
D
D
A
A
A
C
C
CC C
I
H
H
H H
H
H
H
G G G G
G
G
G
BB
D
A
C
H
G
BB 402TC/CS - B 402TC/ CS
BB 1 0 TC/ CS - B 1 0 TC/ CS
BB 20 A/ CS - B 2 0 A/ CS
BB 40/CS - B 40/CS
BB 20 R/ CS - B 2 0R/ CS
B 20TCDCDR/ CS
B 40DCDR/ CS
BB 40 TC/ CS - B 4 0TC/ CS
D
B
A
B
C
B
B
A
C
BB
A
C
B
B
A
C
I
B
I
C
D
H
G
H
G
H
G
H
G
H
G
H
G
H
G
H
G
B 40 TC I
C
B
D
A
B
D
BB 402TC.1
C
B
G
D
H
A
B
D
BB 402TC/CS.1
D
D
B
B
A
C
H
G
E
F
Descrizione dei piani di cotturaDescrizione dei piani di cottura
Descrizione dei piani di cotturaDescrizione dei piani di cottura
Descrizione dei piani di cottura
A
Bruciatore gas AusiliarioBruciatore gas Ausiliario
Bruciatore gas AusiliarioBruciatore gas Ausiliario
Bruciatore gas Ausiliario
B
Bruciatore gas SemirapidoBruciatore gas Semirapido
Bruciatore gas SemirapidoBruciatore gas Semirapido
Bruciatore gas Semirapido
C
Bruciatore gas RapidoBruciatore gas Rapido
Bruciatore gas RapidoBruciatore gas Rapido
Bruciatore gas Rapido
D
Bruciatore gas Tripla CoronaBruciatore gas Tripla Corona
Bruciatore gas Tripla CoronaBruciatore gas Tripla Corona
Bruciatore gas Tripla Corona
I
Bruciatore gas DC-DRBruciatore gas DC-DR
Bruciatore gas DC-DRBruciatore gas DC-DR
Bruciatore gas DC-DR
E
Candela di accensione dei bruciatori gasCandela di accensione dei bruciatori gas
Candela di accensione dei bruciatori gasCandela di accensione dei bruciatori gas
Candela di accensione dei bruciatori gas
F
Dispositivo di sicurezzaDispositivo di sicurezza
Dispositivo di sicurezzaDispositivo di sicurezza
Dispositivo di sicurezza Interviene in caso di spegni-
mento accidentale della fiamma (trabocco di liquidi,
correnti d'aria, ...) bloccando l'erogazione del gas al
bruciatore.
G
Manopole di comando dei bruciatori gasManopole di comando dei bruciatori gas
Manopole di comando dei bruciatori gasManopole di comando dei bruciatori gas
Manopole di comando dei bruciatori gas
H
Griglie di supporto per recipienti di cotturaGriglie di supporto per recipienti di cottura
Griglie di supporto per recipienti di cotturaGriglie di supporto per recipienti di cottura
Griglie di supporto per recipienti di cottura
GRIGLIE APPARECCHI BB... GRIGLIE APPARECCHI B... GRIGLIE APPARECCHI B...BNV
1010
1010
10
THESE INSTRUCTIONS ARE ONLY VALID FOR THE COUNTRIES OF DESTINATION WHOSE SYMBOLS ARETHESE INSTRUCTIONS ARE ONLY VALID FOR THE COUNTRIES OF DESTINATION WHOSE SYMBOLS ARE
THESE INSTRUCTIONS ARE ONLY VALID FOR THE COUNTRIES OF DESTINATION WHOSE SYMBOLS ARETHESE INSTRUCTIONS ARE ONLY VALID FOR THE COUNTRIES OF DESTINATION WHOSE SYMBOLS ARE
THESE INSTRUCTIONS ARE ONLY VALID FOR THE COUNTRIES OF DESTINATION WHOSE SYMBOLS ARE
SHOWN IN THE BOOKLET AND ON THE APPLIANCE RATING PLATE.SHOWN IN THE BOOKLET AND ON THE APPLIANCE RATING PLATE.
SHOWN IN THE BOOKLET AND ON THE APPLIANCE RATING PLATE.SHOWN IN THE BOOKLET AND ON THE APPLIANCE RATING PLATE.
SHOWN IN THE BOOKLET AND ON THE APPLIANCE RATING PLATE.
1.1.
1.1.
1.
This appliance has been designed for private,This appliance has been designed for private,
This appliance has been designed for private,This appliance has been designed for private,
This appliance has been designed for private,
non-professional use in normal dwellings.non-professional use in normal dwellings.
non-professional use in normal dwellings.non-professional use in normal dwellings.
non-professional use in normal dwellings.
2.2.
2.2.
2.
Carefully read the recommendations in thisCarefully read the recommendations in this
Carefully read the recommendations in thisCarefully read the recommendations in this
Carefully read the recommendations in this
instruction booklet, as they give important adviceinstruction booklet, as they give important advice
instruction booklet, as they give important adviceinstruction booklet, as they give important advice
instruction booklet, as they give important advice
regarding safe installation, use and maintenance.regarding safe installation, use and maintenance.
regarding safe installation, use and maintenance.regarding safe installation, use and maintenance.
regarding safe installation, use and maintenance.
Keep this booklet in a safe place for further referenceKeep this booklet in a safe place for further reference
Keep this booklet in a safe place for further referenceKeep this booklet in a safe place for further reference
Keep this booklet in a safe place for further reference
when requiredwhen required
when requiredwhen required
when required
..
..
.
3. After removing the packaging, check that the appliance
is intact. If in doubt, do not use the appliance and contact
professionally qualified personnel.
4. All installation and adjustment operations should be
carried out by qualified engineers in accordance with
current regulations. Specific directions are given in the
“installation instructions” paragraph.
5. Periodically check the condition of the gas connection
pipe and have it replaced by a qualified technician as
soon as it shows any signs of wear or anomaly.
6. Under no circumstances should the user replace the power
supply cable or the gas connection pipe of this appliance.
In the event of damage or the necessity for replacement,
only contact an authorised service centre.
7. Before connecting the appliance, make sure that the data
on the rating plate (situated on the bottom part of the
appliance and on the last page of the booklet) correspond
to those of the mains electricity and gas supplies.
8. Check that the capacity of the electrical system and the
power outlets are suitable for the maximum power of the
appliance, indicated on the rating plate. If in doubt, consult
a professionally qualified technician.
9. Do not leave the appliance plugged in if it is not in use.
Switch off the main switch and gas supply when you are
not using the hob.
10. The gas burners and pan supports remain heated for a
long time after use. Take care not to touch them.
11. To avoid accidental spillage do not use cookware with
uneven or deformed bottoms on the burner.
12. Never use flammable liquids such as alcohol or gasoline,
etc. near the appliance when it is in use.
RecommendationsRecommendations
RecommendationsRecommendations
Recommendations
Congratulations!Congratulations!
Congratulations!Congratulations!
Congratulations!
You have just purchased an electrical household appliance that has been made using advanced technology and quality
materials. As time passes, you will appreciate its practicality and safety, which are constant features of our production.
Disposal of old electrical appliancesDisposal of old electrical appliances
Disposal of old electrical appliancesDisposal of old electrical appliances
Disposal of old electrical appliances
The European Directive 2002/96/EC on Waste Electrical and
Electronic Equipment (WEEE), requires that old household
electrical appliances must not be disposed of in the normal
unsorted municipal waste stream. Old appliances must be
collected separately in order to optimise the recovery and
recycling of the materials they contain and reduce the impact
on human health and the environment. The crossed out
“wheeled bin” symbol on the product reminds you of your
obligation, that when you dispose of the appliance it must be
separately collected.
Consumers may take their old appliance to public waste
collection areas, other communal collection areas, or if
national legislation allows return it to a retailer when
purchasing a similar new product.
All major household appliance manufacturers are active in
the creation of systems to manage the collection and disposal
of old appliances.
13. do not use steam cleaners to clean your oven.
14.The appliance must be used by adults only for the
preparation of food, in accordance with the instructions
outlined in this booklet. Any other use of the appliance
(e.g. for heating the room) constitutes improper use and
is dangerous. The manufacturer may not be held liable
for any damage resulting from improper, incorrect and
unreasonable use of the appliance.
15.The appliance is not intended to be operated by means
of an external timer or separate remote-control system.
16.The appliance should not be operated by people
(including children) with reduced physical, sensory or
mental capacities, by inexperienced individuals or by
anyone who is not familiar with the product. These
individuals should, at the very least, be supervised by
someone who assumes responsibility for their safety or
receive preliminary instructions relating to the operation
of the appliance.
17.Do not let children play with the appliance.
1111
1111
11
Hob descriptionHob description
Hob descriptionHob description
Hob description
A
Auxiliary gas burnerAuxiliary gas burner
Auxiliary gas burnerAuxiliary gas burner
Auxiliary gas burner
B
Semi-rapid gas burnerSemi-rapid gas burner
Semi-rapid gas burnerSemi-rapid gas burner
Semi-rapid gas burner
C
Rapid gas-burnerRapid gas-burner
Rapid gas-burnerRapid gas-burner
Rapid gas-burner
D
Triple ring gas burnerTriple ring gas burner
Triple ring gas burnerTriple ring gas burner
Triple ring gas burner
I
DC-DR gas burnerDC-DR gas burner
DC-DR gas burnerDC-DR gas burner
DC-DR gas burner
E
Ignitor for gas burnersIgnitor for gas burners
Ignitor for gas burnersIgnitor for gas burners
Ignitor for gas burners
F
Safety deviceSafety device
Safety deviceSafety device
Safety device Activates if the flame accidentally goes
out (spills, drafts, etc.), interrupting the delivery of gas to
the burner.
G
Control knobs for gas burnersControl knobs for gas burners
Control knobs for gas burnersControl knobs for gas burners
Control knobs for gas burners
H
Pan supportsPan supports
Pan supportsPan supports
Pan supports
BB 402TC - B 402TC
BB 10 TC - B 1 0TC
BB 20 A - B 2 0A
BB 20 R - B 2 0 R
BB 40 - B 4 0
B 20TCDCDR
B 40DCDR
B 40 TC - BB 4 0TC
A
C
B
I
G
D
H
A
B
D
BB
B
B
BB
B
BB
D
D
D
A
A
A
C
C
CC C
I
H
H
H H
H
H
H
G G G G
G
G
G
BB
D
A
C
H
G
BB 402TC/CS - B 402TC/ CS
BB 1 0 TC/ CS - B 1 0 TC/ CS
BB 20 A/ CS - B 2 0 A/ CS
BB 40 / CS - B 4 0/ CS
BB 20 R/ CS - B 2 0R/ CS
B 20TCDCDR/ CS
B 4 0D CDR/ CS
BB 4 0 TC/ CS - B 4 0 TC/ CS
D
B
A
B
C
B
B
A
C
BB
A
C
B
B
A
C
I
B
I
C
D
H
G
H
G
H
G
H
G
H
G
H
G
H
G
H
G
B 40 TC I
C
B
D
A
B
D
BB 40 2TC.1
C
B
G
D
H
A
B
D
BB 4 0 2TC/ CS.1
D
D
B
B
A
C
H
G
E
F
PAN SUPPORTS FOR BB... PAN SUPPORTS FOR B... PAN SUPPORTS FOR B...BNV
1212
1212
12
Instructions for useInstructions for use
Instructions for useInstructions for use
Instructions for use
No
te
Adjusting the flame levelAdjusting the flame level
Adjusting the flame levelAdjusting the flame level
Adjusting the flame level
The flame level is adjusted by pressing the control knob
and turning it anticlockwise to the following positions:
Black circle = off
full flame
small flame
The symbols near the knobs show the position of the relative
burner on the hob. The burners are fitted with automatic
ignition and thermocouple safety device, which automatically
cuts off the gas from the burner in a few seconds if the
flame accidentally goes out during operation.
To
ignite a burnerignite a burner
ignite a burnerignite a burner
ignite a burner, proceed as follows:
turn the relative knob counter-clockwise until the pointer is
on the high-flame symbol;
• press the knob down fully to activate the automatic gas
ignition ;
keep the knob pressed down for about 10 seconds with
the flame lit to allow the safety thermocouple to be heated;
release the knob, checking that the flame is stable. If it is
not, repeat the operation.
! Some models have a Double Flame burner. In this case, to
activate it, simply start by turning the knob so that it is aligned
with the symbol, then press it all the way in and hold it in
this position for approximately 6 seconds, until the automatic
device keeping the flame alight has heated up.
For minimum power, turn the knob towards the low flame
symbol. Intermediate positions are possible by putting the
knob anywhere between the high and the low flame symbol.
To turn off the burner, turn the knob clockwise to the off
position " " .
Important:Important:
Important:Important:
Important:
Do not activate the automatic ignition device for more than
15 consecutive seconds.
Difficulty in ignition is sometimes due to air inside the gas
duct.
If a burner flame accidentally goes out, the gas continues
to exit for a few moments before the safety device
activates. Turn the control knob to the off position and do
not attempt ignition again for at least 1 minute, thereby
letting the gas disperse, which could otherwise be a
danger.
When the appliance is not in operation, check that the knobs
are in the off position " ". The main gas supply cut-off
cock should also be closed.
Using the burnersUsing the burners
Using the burnersUsing the burners
Using the burners
To obtain maximum efficiency from the burners, it is
advisable to only use pans with a diameter suitable for the
burner being used, so that the flame does not extend beyond
the pan base (see following table).
When a liquid starts boiling, it is advisable to turn the flame
down just enough to keep the liquid simmering.
Note When there is no electricity supply, the burners can be
lit with a match after turning the control knob to the flame
position.
To turn on one of the burners, place a lighted match or lighter
near the burner, press the knob all the way in and turn it anti-
clockwise to the "High" setting.
! Make sure the pans do not overlap the edges of the hob
while it is being used.
! If the racks are unstable, they have been positioned
incorrectly.
The “separate double flame” burnerThe “separate double flame” burner
The “separate double flame” burnerThe “separate double flame” burner
The “separate double flame” burner
This burner consists of two concentric burners which can
operate either together or separately.
Use of the double flame on the maximum setting gives a
very high power which reduces cooking times with respect to
conventional burners.
Moreover the double flame crown provides a more uniform
distribution of heat on the bottom of the pan, when using
both burners on minimum.
Pots and pans of all sizes can be used. In the case of the
smaller pots and pans we recommend the use of only the
internal burner.
There is a separate control knob for each of the “separate
double flame” burners.
The knob
marked
by the symbol operates the external
burner;
The knob
marked
by the symbol operates the internal
burner.
To turn on one of the rings, press the relative knob in all the
way and turn it anti-clockwise to the high setting . The burner
is fitted with an electronic igniter that automatically starts when
the knob is pressed in.
Since the burner is equipped with a safety device "F"Since the burner is equipped with a safety device "F"
Since the burner is equipped with a safety device "F"Since the burner is equipped with a safety device "F"
Since the burner is equipped with a safety device "F",
after lighting the burner keep the knob pressed in for about 6
seconds to allow the device which keeps the flame lit
automatically to heat up.
To turn off a burner,To turn off a burner,
To turn off a burner,To turn off a burner,
To turn off a burner, turn the knob clockwise until it stops (it
should be on the “ ” setting).
To obtain the best results with the cooktop, several
fundamental rules should be followed while cooking or
preparing food. Use cookware with a flat bottom to make
certain that the pot sets properly on the cooking area.
Burner ø Pan Diameter (cm)
A.Auxiliary 6 – 14
B.Semi-rapid 15 – 20
C.Rapid 21 – 26
D. Triple ring 24 - 26
I.Double ring DC-DR (inner) 10 - 14
I.Double ring DC-DR (outer) 24 - 28
1313
1313
13
Cleaning and maintenanceCleaning and maintenance
Cleaning and maintenanceCleaning and maintenance
Cleaning and maintenance
To ensure long life of the appliance, it is essential to carry
out a thorough general clean frequently, taking into account
that:
The appliance should be disconnected from the mainsThe appliance should be disconnected from the mains
The appliance should be disconnected from the mainsThe appliance should be disconnected from the mains
The appliance should be disconnected from the mains
supply before starting cleaning operationssupply before starting cleaning operations
supply before starting cleaning operationssupply before starting cleaning operations
supply before starting cleaning operations.
Avoid cleaning appliance parts when they are still warm.
The enamelled or chromed or glass parts must be washed
with warm water without using abrasive powders or corrosive
substances which could ruin them.
The steel parts, especially in areas with the screen-printed
symbols, should not be cleaned with diluents or abrasive
detergents; preferably use just a soft cloth moistened with
warm water and liquid detergent for washing dishes (wipe
the cloth over the steel in the same direction as the satin-
finish).
Denatured alcohol may be used to remove stubborn dirt.
Stainless steel can be stained if it remains in contact with
agressive detergents (containing phosphorus) or water with
a high lime content. After washing the stainless steel parts
they should be rinsed and dried with a soft cloth
(washleather).
• After cleaning, some special treatments are available to
bring back the shine to steel and to prevent it from yellowing;
for this purpose, we recommend you use the specific
“special cream detergent for steel care” available from our
Assistance Centres.
Avoid leaving acid liquids (vinegar, lemon juice, aggressive
detergents, etc.) on enamelled or painted parts.
• The removable parts of the burners should be washed
frequently with warm water and soap, making sure to remove
caked-on substance. Check that the gas outlet slits are
not clogged. Dry the burners carefully before using them
again.
Frequently clean the end part of the automatic glow plugs
of the hob.
Greasing the tapsGreasing the taps
Greasing the tapsGreasing the taps
Greasing the taps
As time passes, a tap may lock or become difficult to turn. In
this case it will be necessary to clean inside and replace the
grease.
This procedure must be performed by a technicianThis procedure must be performed by a technician
This procedure must be performed by a technicianThis procedure must be performed by a technician
This procedure must be performed by a technician
authorized by the manufacturer.authorized by the manufacturer.
authorized by the manufacturer.authorized by the manufacturer.
authorized by the manufacturer.
1414
1414
14
The ventilation aperture must have the following
characteristics (Fig.2A):
· total free cross section of passage of at least 6 cm² for
every kW of rated heating capacity of the appliance, with a
minimum of 100 cm² (the heating capacity is indicated on
the
rating platerating plate
rating platerating plate
rating plate);
· it must be made in such a way that the aperture, both on
the inside and outside of the wall, cannot be obstructed;
· it must be protected, e.g. with grills, wire mesh, etc. in
such a way that the above-mentioned free section is not
reduced;
· it must be situated as near to floor level as possible.
Detail A Adjacent Room to be
room ventilated
A
Examples of ventilation holes Enlarging the ventilation slot
for comburant air between window and floor
Fig. 2A Fig. 2B
The air inflow may also be obtained from an adjoining room,
provided the latter is not a bedroom or a room where there is
a risk of fire, such as garages, mews, fuel stores, etc. and is
ventilated in compliance with the standards in force.
Air from the adjoining room to the one to be ventilated may
be made to freely pass through permanent apertures with a
cross section at least equal to that indicated above. These
apertures may also be obtained by increasing the gap between
the door and the floor (Fig.2B). If an electric fan is used for
extracting the combustion products, the ventilation aperture
must be increased in relation to its maximum performance.
The electric fan should have a sufficient capacity to guarantee
an hourly exchange of air equal to 3-5 times the volume of
the kitchen. Prolonged, intensive use of the appliance may
require extra ventilation, e.g. an open window or a more
efficient ventilation system by increasing the extraction power
of the electric fan if installed. Liquid petroleum gas descends
towards the floor as it is heavier than air. Apertures in the
outside walls in rooms containing LPG cylinders should
therefore be at floor level, in order to allow any gas from
leaks to be expelled. Do not store LPG cylinders (even when
empty) in basements/rooms below ground level; it is advisable
to keep only the cylinder in use in the room at any one time
and connected far from heat sources which could raise its
temperature to above 50 °C.
The following instructions are provided for qualified installers
so that they may accomplish installation, adjustment and
technical maintenance operations correctly and in compliance
with current regulations and standards.
Important: the hob should be disconnected from theImportant: the hob should be disconnected from the
Important: the hob should be disconnected from theImportant: the hob should be disconnected from the
Important: the hob should be disconnected from the
mains electricity supply before any adjustment,mains electricity supply before any adjustment,
mains electricity supply before any adjustment,mains electricity supply before any adjustment,
mains electricity supply before any adjustment,
maintenance, etc. is carried out.maintenance, etc. is carried out.
maintenance, etc. is carried out.maintenance, etc. is carried out.
maintenance, etc. is carried out. Maximum caution should
be used whenever it is necessary to keep the appliance
connected to the electricity supply.
The hobs have the following
technical characteristics:technical characteristics:
technical characteristics:technical characteristics:
technical characteristics:
-Category II 2H3+-Category II 2H3+
-Category II 2H3+-Category II 2H3+
-Category II 2H3+
- Class 1: - Class 1:
- Class 1: - Class 1:
- Class 1: all models whose edges are higher than/equal to
75 mm (see following page, fig. 4, detail H3).
- Class 3: - Class 3:
- Class 3: - Class 3:
- Class 3: all models whose edges are lower than/equal to 75
mm (see following page, fig. 4, detail H1 and H2).
PositioningPositioning
PositioningPositioning
Positioning
This appliance may only be installed and operated in
permanently ventilated rooms in compliance with provisions
laid down by current regulations and standards. The following
requirements must be observed:
The appliance must discharge combustion products into a
special hood, which must be connected to a chimney, flue
pipe or directly to the outside (Fig.1).
If it is impossible to fit a hood, the use of an electric fan is
permitted, either installed on a window or on an external
wall, which must be switched on at the same time as the
appliance.
In a chimney stack or branched flue Directly to the outside
(exclusively for cooking appliances)
Kitchen ventilationKitchen ventilation
Kitchen ventilationKitchen ventilation
Kitchen ventilation
The air flow into the room where the appliance is installed
must equal the quantity of air that is required for regular
combustion of the gas and for ventilating the same room.
Air must be taken in naturally through permanent apertures
made in the outside walls of the room or through single or
branching collective ventilation ducts in compliance with the
standards in force.
The air must be taken directly from the outside, from an area
far from sources of pollution.
instructions for the installerinstructions for the installer
instructions for the installerinstructions for the installer
instructions for the installer
FigFig
FigFig
Fig.1
1515
1515
15
Hobs installationHobs installation
Hobs installationHobs installation
Hobs installation
FigFig
FigFig
Fig.3
Make sure you take all the necessary precautions to
guarantee proper installation in compliance with the
applicable norms in force regarding accident-prevention for
electrical connection. For the correct operation of the
appliance when built into the cabinet, it is vital that the
minimum distances illustrated in Fig. 3 be respected. The
hob features a type Y degree of protection against
overheating in compliance with norms. All surfaces adjacent
to the cabinet and the back panel should be made of
materials resistant to a temperature of 65°C.
Min.
700mm
5
0 mm
50 m
m
Securing the appliance to the cabinetSecuring the appliance to the cabinet
Securing the appliance to the cabinetSecuring the appliance to the cabinet
Securing the appliance to the cabinet
There are three different groups of appliance as far as
installation is concerned:
BUILT-IN HOB
HEIGHT= STEEL THICKNESS
BUILT-IN HOB
STEEL TICKNESS <HEIGHT <75 mm
SIT ON - ON HOB
HEIGHT >75 mm
1- Built-in hobs to be slotted in (Class 3 - see1- Built-in hobs to be slotted in (Class 3 - see
1- Built-in hobs to be slotted in (Class 3 - see1- Built-in hobs to be slotted in (Class 3 - see
1- Built-in hobs to be slotted in (Class 3 - see
figure 4, detail H1).figure 4, detail H1).
figure 4, detail H1).figure 4, detail H1).
figure 4, detail H1). In this case it is necessary to make
a hole in the worktop whose measurements match those of
the hob. The measurement at the side should be reduced
by 2 cm so as to ensure that 1 cm of the perimeter of the
hob overlaps with and rests on top of the supporting surface.
To slot in the hob flush with the worktop, the cut-out on this
supporting surface must be lowered (see figure 5), so that
both the edge of the hob and the seal under it can be
positioned there. Before fitting the hob to the worktop,
position the seal
"X""X"
"X""X"
"X" provided along the perimeter of the
hob, as illustrated in figure 5.
fig.5
X
20 mm
1.5
mm
1.5
mm
A
B
C
X
mm
fig.6
2-Built-in hobs (Class 3) with edges lower than 752-Built-in hobs (Class 3) with edges lower than 75
2-Built-in hobs (Class 3) with edges lower than 752-Built-in hobs (Class 3) with edges lower than 75
2-Built-in hobs (Class 3) with edges lower than 75
mm (see figure 4, detail H2). mm (see figure 4, detail H2).
mm (see figure 4, detail H2). mm (see figure 4, detail H2).
mm (see figure 4, detail H2). To install this type of hob,
a hole large enough to accommodate the whole lower casing
of the appliance must be made on the worktop intended to
be under the hob. Remember to leave a gap of at least 1 cm
between the lower casing and the worktop around the whole
perimeter of the appliance (the underside of the casing can,
however, touch the surface below it). To fit the appliances,
follow the instructions given above in point 1 or use any
supplementary instruction leaflet that is provided in special
cases.
3-Sit-on hobs (Class 1) with edges higher than 75 mm3-Sit-on hobs (Class 1) with edges higher than 75 mm
3-Sit-on hobs (Class 1) with edges higher than 75 mm3-Sit-on hobs (Class 1) with edges higher than 75 mm
3-Sit-on hobs (Class 1) with edges higher than 75 mm
(see figure 4, detail H3).(see figure 4, detail H3).
(see figure 4, detail H3).(see figure 4, detail H3).
(see figure 4, detail H3). In this case, the lower casing of the
hob does not protrude further than the edge of the appliance.
Even when the hob is resting on the worktop, it will suffice to
leave space for the gas supply tube and electricity supply
cable. To fit this type of hob, follow the instructions below (fig.
6):
• Fix the two screws provided "A" at a distance from the
back panel as shown in figure 6, leaving the heads of the
screws sticking out of the wood by 1.5 mm.
• Hook the hob onto the two screws "A" and push it towards
the back.
• Fix the appliance to the cabinet at the rear, using the two
brackets "B" and the four screws "C" (these are all provided).
N.B.: to make maintenance operations more efficient, theN.B.: to make maintenance operations more efficient, the
N.B.: to make maintenance operations more efficient, theN.B.: to make maintenance operations more efficient, the
N.B.: to make maintenance operations more efficient, the
area around the hob must be easily accessible after itarea around the hob must be easily accessible after it
area around the hob must be easily accessible after itarea around the hob must be easily accessible after it
area around the hob must be easily accessible after it
has been installed (i.e. there are no completely shut-offhas been installed (i.e. there are no completely shut-off
has been installed (i.e. there are no completely shut-offhas been installed (i.e. there are no completely shut-off
has been installed (i.e. there are no completely shut-off
elements).elements).
elements).elements).
elements).
1616
1616
16
Gas supply connectionGas supply connection
Gas supply connectionGas supply connection
Gas supply connection
Check that the appliance is set for the type of gas available
and then connect it to the mains gas piping or the gas
cylinder in compliance with current regulations and
standards.
This appliance is designed and set to work with the gas
indicated on the label situated on the actual hob. If the gas
supply is other than the type for which the appliance has
been set, proceed with replacing the corresponding nozzles
(provided), following instructions given in the paragraph
“Adaptation to different types of gas”.
For trouble-free operation, suitable use of energy and longer
life of the appliance, make sure that the supply pressure
complies with the values indicated in the table 1 "burners
and nozzles specifications, otherwise install a special
pressure regulator on the supply pipe in compliance with
current standards and regulations.
Connect in such a way that the appliance is subjected to
no strain whatsoever.
Either a rigid metal pipe with fittings in compliance with the
standards in force must be used for connecting to the nipple
union (threaded ½"G male fitting) situated at the rear of the
appliance to the right (Fig.7), or flexible steel pipe in
compliance with the standards in force, which must not
exceed 2000 mm in length. Should it be necessary to turn
the fitting, the gasket (supplied with the appliance) must be
replaced. Upon completion of installation, check the gas
circuit, the internal connections and the taps for leaks using
a soapy solution (never a flame). Also check that the
connecting pipe cannot come into contact with moving parts
which could damage or crush it. Make sure that the natural
gas pipe is adequate for a sufficient supply to the appliance
when all the burners are lit
Important:Important:
Important:Important:
Important: A pressure regulator, in compliance with the
standards in force, must be inserted when connecting to a
liquid gas supply (in a cylinder).
Adaptation to a different type of gasAdaptation to a different type of gas
Adaptation to a different type of gasAdaptation to a different type of gas
Adaptation to a different type of gas
If the hob is to be converted for use with a type of gas other
than that for which it was set in the factory (indicated on the
label to be found on the hob), the burner nozzles should be
replaced as follows:
Remove the pan supports and the burners.
• Unscrew the nozzles “
AA
AA
A” (Fig.7) using a 7 mm socket
wrench and replace them with the ones which have a
diameter suitable for the type of gas to be used, according
to the table 1 "burners and nozzles specifications).
• On completing the operation, replace the old rating label
with the one showing the new type of gas; the sticker is
available from our Service Centres.
Adjusting the low flameAdjusting the low flame
Adjusting the low flameAdjusting the low flame
Adjusting the low flame
· Put the tap to the low flame position;
· Remove the tap knob and turn the adjusting screw, situated
inside of the tap stem (Fig.8), using a screwdriver
(loosening the screw increases the height of the flame,
tightening decreases it).
note:note:
note:note:
note: the adjusting screw must be fully screwed down for
liquid gas.
· Having obtained the low flame setting required and with
the burner lit, abruptly change the position of the knob
several times from minimum to maximum and vice versa
and check that the flame does not go
Gas supply connectionGas supply connection
Gas supply connectionGas supply connection
Gas supply connection
Replacing the nozzles on separate “double flame “Replacing the nozzles on separate “double flame “
Replacing the nozzles on separate “double flame “Replacing the nozzles on separate “double flame “
Replacing the nozzles on separate “double flame “
burners:burners:
burners:burners:
burners:
remove the grids and slide the burners from their housings.
The burner consists of 2 separate parts (Fig. C and fig.
D);
unscrew the burers with a 7 mm wrench spanner. The
internal burner has a nozzle, the external burner has two
(of the same size). Replace the nozzle with models suited
to the new type of gas (see table 1).
replace all the components by repeating the steps in
reverse order.
Fig. C Fig. D
Regulation of Air Supply to the BurnerRegulation of Air Supply to the Burner
Regulation of Air Supply to the BurnerRegulation of Air Supply to the Burner
Regulation of Air Supply to the Burner
The burners do not need a primary air regulator.
Minimum RegulationMinimum Regulation
Minimum RegulationMinimum Regulation
Minimum Regulation
• Turn the gas valve to minimum.
• Remove the tap knob and turn the adjusting screw, situated
inside of the tap stem (Fig.9), using a screwdriver (loosening
the screw increases the height of the flame, tightening
decreases it).
N.B.:N.B.:
N.B.:N.B.:
N.B.: In the case of liquid gas, the regulation screw must
be fully screwed in (clockwise).
• Make sure that, when the knob is turned rapidly high to
low, the flame does not go out.
• In the event of a malfunction on appliances with the security
device (thermocouple) when the gas supply is set at
minimum, increase the minimum supply levels using the
regulator screw.
Once the adjustment has been made, apply sealing wax, or
a suitable substitute, to the old seals on the by-pass.
fig.8
fig.7
fig.9
1717
1717
17
Burners and nozzles specificationsBurners and nozzles specifications
Burners and nozzles specificationsBurners and nozzles specifications
Burners and nozzles specifications
This appliance conforms with the following EuropeanThis appliance conforms with the following European
This appliance conforms with the following EuropeanThis appliance conforms with the following European
This appliance conforms with the following European
Economic Community directives:Economic Community directives:
Economic Community directives:Economic Community directives:
Economic Community directives:
- 2006/95/
EECEEC
EECEEC
EEC of 12/12/06 (Low Voltage) and subsequent
modifications;
- 2004/108/
EECEEC
EECEEC
EEC of 15/12/04 (Electromagnetic Compatibility)
and subsequent modifications;
- 2009/142/
EECEEC
EECEEC
EEC of 30/11/09 (Gas) and subsequent
modifications;
- 93/68/
EECEEC
EECEEC
EEC of 22/07/93 and subsequent modifications.
* At 15°C and 1013 mbar-dry gas
Propane G31 H.s. = 50,37 MJ/kg
Butane G30 H.s. = 49,47 MJ/kg
Methane G20 H.s. = 37,78 MJ/m
3
Electrical connectionElectrical connection
Electrical connectionElectrical connection
Electrical connection
THE APPLIANCE MUST BE EARTHED
The hobs are designed to work with alternating current at the
supply voltage and frequency indicated on the rating plate
(situated under the hob or at the end of the instruction booklet).
Make sure that the local supply voltage corresponds to the
voltage indicated on the rating plate.
Connecting the supply cable to the mains electricityConnecting the supply cable to the mains electricity
Connecting the supply cable to the mains electricityConnecting the supply cable to the mains electricity
Connecting the supply cable to the mains electricity
supplysupply
supplysupply
supply
For models supplied without a plug, fit a standard plug,
suitable for the load indicated on the rating plate, onto the
cable and connect to a suitable socket.
To connect directly to the mains supply, a double-pole switch
with a contact separation of at least 3 mm suitable for the
load and complying with current standards and regulations,
must be fitted between the appliance and the mains supply
outlet. The yellow-green earth wire must not be interrupted
by the switch. The supply cable must be in such a position
that no part of it can reach a temperature of 50 °C above
room temperature. For installation above a built-under oven,
the hob and the oven must be connected separately to the
electricity supply both for safety reasons and for easy removal
of the oven if necessary. Do not use adapters or shunts as
they could cause heating or burning.
Before connecting to the power supply, make sure that:
the limiter valve and the domestic system can withstand
the load from the appliance (
see rating platesee rating plate
see rating platesee rating plate
see rating plate);
the supply system is efficiently earthed according to
standards and laws in force;
the socket or double-pole switch are easily accessible when
the appliance is installed.
Important:Important:
Important:Important:
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
- Earth- Earth
- Earth- Earth
- Earth
Blue
- Neutral- Neutral
- Neutral- Neutral
- Neutral
Brown
- Live- Live
- Live- Live
- Live
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to terminal marked “
EE
EE
E” or
or coloured Green or Green & Yellow. Connect the Brown
wire to the terminal marked “
LL
LL
L” or coloured Red. Connect the
Blue wire to the terminal marked “
NN
NN
N” or coloured Black.
FAILURE TO OBSERVE THE ACCIDENT-PREVENTION
REGULATIONS RELIEVES THE MANUFACTURER OF ALL
LIABILITY.
Replacing the cableReplacing the cable
Replacing the cableReplacing the cable
Replacing the cable
Use a rubber cable of the type H05RR-F (H05VV-F for mod.
not .../CS) with a suitable cross section 3 x 0.75 mm². The
yellow-green earth wire must be 2-3 cm longer than the other
wires.
Table 1 Liquid gas Natural gas
BURNER
Diameter
(mm)
Thermal power
kW (H.s.*)
By-pass
1/100
(mm)
Injector
1/100
(mm)
Flow *
g/h
Injector
1/100
(mm)
Flow*
l/h
Nomin. Reduc. G30 G31 G20
D. Triple Ring 130 3.25 1.30 57 91 236 232 124 309
C.Rapid 100 3.00 0.70 40 86 218 214 116 286
C.Rapid (for model B20R/CS
BNV...)
100 3.00 0.70 40 82 196 193 116 286
B. Semi-rapid 75 1.65 0.40 30 64 120 118 96 157
A. Auxiliary 55 1.00 0.40 30 50 73 71 71 95
I. Double flame DC DR (internal) 30 0.90 0.40 30 44 65 64 70 86
I. Double Flame DC DR (external) 130 4.10 1.30 57 70 298 293 110 390
Supply pressure
Nominal
Minimum
Maximum
28-30
20
35
37
25
45
20
17
25
1919
1919
19
Description du plan de cuissonDescription du plan de cuisson
Description du plan de cuissonDescription du plan de cuisson
Description du plan de cuisson
A
Brûleur gaz AuxiliaireBrûleur gaz Auxiliaire
Brûleur gaz AuxiliaireBrûleur gaz Auxiliaire
Brûleur gaz Auxiliaire
B
Brûleur gaz Semi rapideBrûleur gaz Semi rapide
Brûleur gaz Semi rapideBrûleur gaz Semi rapide
Brûleur gaz Semi rapide
C
Brûleur gaz RapideBrûleur gaz Rapide
Brûleur gaz RapideBrûleur gaz Rapide
Brûleur gaz Rapide
D
Brûleur gaz Triple couronneBrûleur gaz Triple couronne
Brûleur gaz Triple couronneBrûleur gaz Triple couronne
Brûleur gaz Triple couronne
I
Brûleur gaz DC-DRBrûleur gaz DC-DR
Brûleur gaz DC-DRBrûleur gaz DC-DR
Brûleur gaz DC-DR
G
Manettes de commande des brûleurs gazManettes de commande des brûleurs gaz
Manettes de commande des brûleurs gazManettes de commande des brûleurs gaz
Manettes de commande des brûleurs gaz
E
Bougie d'allumage des brûleurs gazBougie d'allumage des brûleurs gaz
Bougie d'allumage des brûleurs gazBougie d'allumage des brûleurs gaz
Bougie d'allumage des brûleurs gaz
F
Dispositif de sécurité Dispositif de sécurité
Dispositif de sécurité Dispositif de sécurité
Dispositif de sécurité Intervient en cas d'extinction
accidentelle de la flamme (débordement de liquides,
courants d'air, ...) en interrompant automatiquement
l'arrivée de gaz.
H
Grilles support de casserolesGrilles support de casseroles
Grilles support de casserolesGrilles support de casseroles
Grilles support de casseroles
BB 402TC - B 402TC
BB 10 TC - B 1 0TC
BB 20A - B 20A
BB 20R - B 20R
BB 40 - B 4 0
B 2 0TCD CD R
B 40DCDR
B 40 TC - BB 4 0TC
A
C
B
I
G
D
H
A
B
D
BB
B
B
BB
B
BB
D
D
D
A
A
A
C
C
CC C
I
H
H
H H
H
H
H
G G G G
G
G
G
BB
D
A
C
H
G
BB 402TC/CS - B 402TC/ CS
BB 1 0 TC/ CS - B 1 0 TC/ CS
BB 20 A/ CS - B 2 0 A/ CS
BB 40 / CS - B 4 0/ CS
BB 20 R/ CS - B 2 0R/ CS
B 2 0TCD CD R/ CS
B 4 0D CDR/ CS
BB 4 0 TC/ CS - B 4 0 TC/ CS
D
B
A
B
C
B
B
A
C
BB
A
C
B
B
A
C
I
B
I
C
D
H
G
H
G
H
G
H
G
H
G
H
G
H
G
H
G
B 40TC I
C
B
D
A
B
D
BB 402TC.1
C
B
G
D
H
A
B
D
BB 402TC/CS.1
D
D
B
B
A
C
H
G
E
F
GRILLES POUR TABLES GRILLES POUR TABLES GRILLES POUR TABLES
DE CUISSON BB... DE CUISSON B... DE CUISSON B...BNV
3535
3535
35
Omschrijving van de kookplaatOmschrijving van de kookplaat
Omschrijving van de kookplaatOmschrijving van de kookplaat
Omschrijving van de kookplaat
A
Hulp gasbranderHulp gasbrander
Hulp gasbranderHulp gasbrander
Hulp gasbrander
B
Halfsnelle gasbranderHalfsnelle gasbrander
Halfsnelle gasbranderHalfsnelle gasbrander
Halfsnelle gasbrander
C
Snelle gasbranderSnelle gasbrander
Snelle gasbranderSnelle gasbrander
Snelle gasbrander
D
Drioevoudige Ring gasbranderDrioevoudige Ring gasbrander
Drioevoudige Ring gasbranderDrioevoudige Ring gasbrander
Drioevoudige Ring gasbrander
I
DC-DR gasbranderDC-DR gasbrander
DC-DR gasbranderDC-DR gasbrander
DC-DR gasbrander
E
Bougies van de automatische ontstekingBougies van de automatische ontsteking
Bougies van de automatische ontstekingBougies van de automatische ontsteking
Bougies van de automatische ontsteking
F
VeiligheidsmechanismeVeiligheidsmechanisme
VeiligheidsmechanismeVeiligheidsmechanisme
Veiligheidsmechanisme Dit treedt in werking als de
vlam per ongeluk is uitgegaan (overkoken, tocht enz.)
door de gastoevoer van de brander te blokkeren.
G
Bedieningsknoppen van de gasbrandersBedieningsknoppen van de gasbranders
Bedieningsknoppen van de gasbrandersBedieningsknoppen van de gasbranders
Bedieningsknoppen van de gasbranders
H
Roosters voor de pannenRoosters voor de pannen
Roosters voor de pannenRoosters voor de pannen
Roosters voor de pannen
BB 402TC - B 402TC
BB 10TC - B 10TC
BB 20 A - B 2 0 A
BB 20 R - B 2 0 R
BB 40 - B 4 0
B 20TCDCDR
B 40DCDR
B 40 TC - BB 4 0 TC
A
C
B
I
G
D
H
A
B
D
BB
B
B
BB
B
BB
D
D
D
A
A
A
C
C
CC C
I
H
H
H H
H
H
H
G G G G
G
G
G
BB
D
A
C
H
G
BB 402TC/ CS - B 402TC/ CS
BB 10 TC/ CS - B 1 0TC/ CS
BB 20A/CS - B 20A/CS
BB 40 / CS - B 4 0/ CS
BB 20 R/ CS - B 2 0R/ CS
B 20TCDCDR/ CS
B 4 0D CDR/ CS
BB 40 TC/ CS - B 4 0TC/ CS
D
B
A
B
C
B
B
A
C
BB
A
C
B
B
A
C
I
B
I
C
D
H
G
H
G
H
G
H
G
H
G
H
G
H
G
H
G
B 40 TC I
C
B
D
A
B
D
BB 402TC.1
C
B
G
D
H
A
B
D
BB 4 0 2 TC/ CS.1
D
D
B
B
A
C
H
G
E
F
ROOSTERS APPARATEN BB... ROOSTERS APPARATEN B... ROOSTERS APPARATEN B...BNV
Conformément à nos conditions générales de vente, nous nous réservons la faculté de modifier nos
modèles sans préavis: et cette brochure ne peut être considérée comme un document contractuel.
Conformemente alle nostre condizioni generali di vendita, ci riserviamo la facoltà di modificare i nostri
modelli senza preavviso. Questo opuscolo non può essere considerato come un documento contrattuale.
In conformity with our general conditions of sale, we reserve the right to modify our models without
notice and this booklet can in no way be considered as a binding document.
Overenkomstig onze verkoopvoorwaarden behouden wij ons het recht voor onze modellen zonder voorafgaande
kennisgeving te vjzigen: dit boekje kan niet als cen contractueel dokument worden beschouwd.
This document is printed by
Xerox Fabriano - 07/2010
Document number:
195035548.06
Viale Aristide Merloni, 47
60044 Fabriano (AN) Italy
Tel. +39 0732 6611
www.scholtes.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Scholtes B 402TC/CS BNV F User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI