41368-0-0120 Page 5
Instructions to Installer
1. Leave instruction manual with owner.
2. HaveownerlloutandmailProductRegistrationCard
suppliedwiththereplace.
3. Showownerhowtostartandoperatethereplace.
Thisdirect-ventgasreplaceheaterisdesignedtooperatewith
all combustion air being siphoned from the outside of the building
andallexhaustgasesexpelledtotheoutsideofthebuilding.The
information contained in this manual pertains to all models and
gas control systems unless otherwise noted.
Appliance Certication
WARNING
This replace is not for use with solid fuels. Solid fuels
could cause personal injury or property damage.
ThisreplaceisdesigncertiedinaccordancewithAmerican
NationalStandard/CSAStandardANSIZ21.88/CSA2.33andby
UnderwritersLaboratoriesasaDirectVentGasFireplaceHeater
and shall be installed according to these instructions.
Consult your local building code agency, prior to installation,
to ensure compliance with local codes-including permits and
inspections.
Thereplace,wheninstalled,mustbeelectricallygroundedin
accordance with local codes or, in absence of local codes, with
the National Electric Code ANSI/NFPA 70 or Canadian Electric
code,CSAC22.1,ifanexternalelectricalsourceisutilized.
Thesemodelsmaybeinstalledinabedroomorbed-sittingroom
intheU.S.A.andCanada.
Qualied Installing Agency
Installation and replacement of gas piping, gas utilization
equipment or accessories and repair and servicing of equipment
shallbeperformedonlybyaqualiedagency.Theterm“qualied
agency”meansanyindividual,rm,corporationorcompany
which either in person or through a representative is engaged
in and is responsible for (a) the installation or replacement of
gas piping or (b) the connection, installation, repair or servicing
of equipment, who is experienced in such work, familiar with all
precautions required and has complied with all the requirements
of the authority having jurisdiction.
Commonwealth of Massachusetts: Theinstallationmustbe
madebyalicensedplumberorgastterintheCommonwealth
of Massachusetts.
WARNING
ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS
CAN BE DANGEROUS.
Improper installation or use of the replace can cause
serious injury or death from re, burns, explosions, or
carbon monoxide poisoning.
Theinstallationmustconformwithlocalcodesor,intheabsence
of local codes, with the National Fuel Gas Code ANSI Z223.1/
NFPA 54* Natural Gas and Propane Installation Code, or CSA
B149.1 in Canada. *Available from the American National
Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10036.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
Important
AllcorrespondenceshouldrefertocompleteModelNumber,
SerialNumberandtypeofgas.
High Altitude
Wheninstallingthisreplaceatanelevationabove2000feet
(intheUnitedStates)itmaybenecessarytodecreasetheinput
ratingbychangingtheexistingburneroricetoasmallersize.
Generally, input should be reduced 4 percent for each 1000
feet above sea level. However, if the heating value of the gas
has been reduced, this general rule may not apply. Check with
EmpireComfortSystemsforproperoricesizeidentication.
Canadian High Altitude
Altitude:0-4500feet(0-1370m)
Wheninstallingthisreplaceatanelevationabove4500feet(in
Canada),checkwithEmpireComfortSystemsforassistancein
determiningtheproperoriceforlocation.
Preparation
Thisdirectventgasreplaceanditscomponentsaretestedand
safe when installed in accordance with this installation manual.
Reporttoyourdealeranypartsdamagedinshipment,specically
checkglasscondition.Donotinstallreplacewithdamaged,
incomplete, or substitute parts. Read all instructions before
starting installation and follow these instructions carefully during
installationtoinsuremaximumbenetandsafety.Failureto
followthemwillvoidyourwarrantyandmaypresentarehazard.
Thewarrantywillbevoidedby,andthewarranterdisclaimsany
responsibilityforthefollowingactions:
• Installationofanydamagedreplaceorventsystem
component.
• Modicationofthereplaceordirectventsystem.
• Installation other than as instructed by Empire Comfort
SystemsInc.
• Improper positioning of the glass door, or decorative
accessories including logs, rocks, crushed glass or other
approved media.
• Installation and/or use of any component part not
manufactured or approved by manufacturer.
INTRODUCTION