SECO-LARM E-931CS22RRCQ Owner's manual

Type
Owner's manual

This manual is also suitable for

Specifications:
Troubleshooting:
Dimensions:
PITSW3
®
E-931CS22RRCQ
Retro-Reflective Photoelectric Entry Alert System
22' (7 m)
Sensor: 9-15 VDC, Chime: 9-15 VDC
100mA Max.
30mA
IR LED
-4
0
F (-20
0
C) ~ 122
0
F (50
0
C)
~1 sec. for Chime, 30 sec. for Alarm
Adjustable from 0 ~ 90 dB at 1m (max.)
Adjustable 3~30sec. for alarm
Chime / Off /Alarm (Select by switch)
All Included
Model Number
Type
Sensing Range
Voltage Supply
Total Current Consumption
Stand-by Current
Light Source
Ambient Temperature
Speaker Response Time
Speaker Volume
Alarm Time Range
Speaker Output
Mounting Brackets
Red LED does not turn on.
1) Reflector and/or sensor is misaligned.
2) No power.
1) Adjust the reflector and/or sensor for
proper alignment
2) Check power adapter and cable.
Sensor does not detect the object. Sensor not aligned properly.
Change the angle of the sensor or
reflector.
Trouble Remedy(s)Possible Origin(s)
NOTICE:
The information and specifications printed in this manual are current at the time of publication. However,
the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right
to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2016 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or
in part, without the written permission of SECO-LARM.
SECO-LARM
®
U.S.A., Inc.,
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999
Fax: 949-261-7326 Website: www.seco-larm.com E-mail: [email protected]
WARRANTY:
ENFORCER Photobeam Sensors are warranted against defects in material and workmanship while
used in normal service for a period of one (1) year from the date of sale to the original customer. Our obligation is
limited to the repair or replacement of any defective part if the unit is returned, transportation pre-paid, to SECO-LARM.
5
/
16
" (8.2mm)
2
7
/
16
" (62mm)
2
13
/
16
" (71mm)
2
3
/
8
" (60mm)
1
3
/
8
"
(35mm)
1
3
/
16
" (30mm)
2
13
/
16
" (71mm)
MiE931CS22RRCQ_181008.pdf
2
1
/
64
" (51.3mm)
2
25
/
64
" (60.3mm)
E-931CS22RRCQ
Range: 22ft. (7m)
Retro-Reflective Photoelectric
Sensor Entry Alert System
Sensor
Caution:
ENFORCER
®
Features:
••
••
Retro-reflective photoelectric sensor.
••
••
Range: Up to 22 feet (7m).
••
••
Perfect for monitoring an entrance, or for counting
foot traffic with optional counter.
••
••
Will make “ding-dong” sound or alarm sound
when the beam is interrupted.
••
••
Speaker volume can be adjusted or turned off.
••
••
When in alarm mode, sounding time is adjustable
from 3 to 30 seconds.
This sensor was not designed to prevent bodily injury or loss of life.
Use of this sensor in certain security applications may be regulated by local laws or codes.
SECO-LARM is not responsible for compliance with such laws or codes.
••
••
All components plug into each other.
No hard wiring required.
••
••
Optional counter available (E-931ACC-CQ).
••
••
Optional second speaker available (E-931ACC-SQ).
••
••
Includes the following:
Retro-reflective photoelectric sensor.
Reflector.
Speaker/electronic chime.
Power adapter.
Included:
E-931ACC-BLS4Q
Sensor Bracket
E-931ACC-BLR2Q
Reflector bracket
Power
Adapter
E-931ACC-SQ
Speaker/Electronic Chime
ENF ORCER
®
E-931CS22SQ
Transmitter/Receiver
EN FORC E R
®
E-931ACC-R2Q
Reflector
2
1
/
64
" (51.3mm)
2
1
/
64
" (51.3mm)
2
25
/
64
" (60.3mm)
INSTALLATION MANUAL
Mounting the Reflector:
Installation and Adjustment:
Sample Fixed Mounting:
Mounting the Sensor:
Mounting the Speaker/Electronic Chime:
Sample
Fixed
Mounting:
Sample
Bracket
Mounting:
Adjusting the Speaker/Electronic Chime:
LED Functions:
RED LED - When ON, it indicates the sensor is
powered and aligned properly.
Installation:
1. Mount the reflector and sensor so they face each
other at about 2' off the ground or knee high.
2. Connect the sensor to the speaker.
3. Connect power adaptor to the speaker.
For signalling in multiple rooms, add an optional
second speaker (E-931ACC-SQ).
Connect an optional counter (E-931ACC-CQ) to
the speaker output (if desired).
4. To find the correct alignment, slowly adjust the
angles of the sensor and/or reflector up and down
and right and left.
5. Do not let sunlight or any direct beam of light
enter the sensing spot of the sensor.
NOTE:Correct alignment is reached when red LED
turns ON.
Set Speaker Mode:
After the sensor and reflector have been properly
installed, the next step is to set the speaker mode.
1.
Choose between "Chime" or "Alarm" sound or "OFF".
2. If "Alarm" was chosen:
A. Set speaker to Alarm
B. Adjust the alarm sounding time from 3 to 30
seconds.
C. Set speaker Volume.
3. If "Chime" was chosen: Set speaker to Chime
4. If "OFF" was chosen:
A. Set speaker to OFF
B. The speaker will not sound when the beam is
broken.
Using the Optional Counter:
1. Automatically increases by "1" when sensor is
triggered.
2. Manually add "1" by pressing "+".
3. Manually subtract "1" by pressing "
-
".
4. Reset counter by pressing "RESET."
Testing:
1. Power up the sensor and speaker. The red LED
should be ON.
2. Pass object to be detected between the sensor
and reflector. The red LED should turn OFF and
the speaker (if connected) should sound.
Red LED
ENFORCER
®
Switch: Chime/
OFF/Alarm
Timer: 3~30 Sec.
Volume:0 ~ max.
Switch
Wall mount hole
Bracket
mounting
holes
Wiring: (one speaker, no counter)
W
e
m
e
c
l
o
Other possible applications: Offices, stores, schools, warehouse, vehicle detection, etc.
Garage
door


Sample Installations:
Main
entrance
door
Store front door
Optional Accessories:
E-931ACC-RC1Q
Round Reflector
82 x 9 mm
E-931ACC-CQ
Digital Counter
(with 32ft wire)
E-931ACC-HR1Q
Reflector Hood for
Round/Square Reflectors
Wiring: (with optional counter and second speaker)
Reflector
Sensor
Adaptor
Input
Up to 22' (7m)
Speaker
ENF ORCER
®
Counter (optional)
Speaker (optional)
ENF ORCER
®
Input
Output
Output
NOTE: a) When adding a 2nd speaker. If the application distance between speakers exceed 33 ft. (10m),
then a power adaptor is required for the 2nd speaker.
b) When there are 2 devices added to the first speaker, such as a 2nd speaker & a counter.
Then a second power adaptor is required for the 2nd speaker even when the distance is within 33 ft. (10m)
c) Speaker and counter uses a standard 1/8" stereo jacks.
E-931ACC-SQ
Speaker/Electronic Chime
(with 32ft wire)
E-931ACC-BLS8Q
Door Frame Bracket
EN FORCER
®
Mounting the Reflector:
Installation and Adjustment:
Sample Fixed Mounting:
Mounting the Sensor:
Mounting the Speaker/Electronic Chime:
Sample
Fixed
Mounting:
Sample
Bracket
Mounting:
Adjusting the Speaker/Electronic Chime:
LED Functions:
RED LED - When ON, it indicates the sensor is
powered and aligned properly.
Installation:
1. Mount the reflector and sensor so they face each
other at about 2' off the ground or knee high.
2. Connect the sensor to the speaker.
3. Connect power adaptor to the speaker.
For signalling in multiple rooms, add an optional
second speaker (E-931ACC-SQ).
Connect an optional counter (E-931ACC-CQ) to
the speaker output (if desired).
4. To find the correct alignment, slowly adjust the
angles of the sensor and/or reflector up and down
and right and left.
5. Do not let sunlight or any direct beam of light
enter the sensing spot of the sensor.
NOTE:Correct alignment is reached when red LED
turns ON.
Set Speaker Mode:
After the sensor and reflector have been properly
installed, the next step is to set the speaker mode.
1.
Choose between "Chime" or "Alarm" sound or "OFF".
2. If "Alarm" was chosen:
A. Set speaker to Alarm
B. Adjust the alarm sounding time from 3 to 30
seconds.
C. Set speaker Volume.
3. If "Chime" was chosen: Set speaker to Chime
4. If "OFF" was chosen:
A. Set speaker to OFF
B. The speaker will not sound when the beam is
broken.
Using the Optional Counter:
1. Automatically increases by "1" when sensor is
triggered.
2. Manually add "1" by pressing "+".
3. Manually subtract "1" by pressing "
-
".
4. Reset counter by pressing "RESET."
Testing:
1. Power up the sensor and speaker. The red LED
should be ON.
2. Pass object to be detected between the sensor
and reflector. The red LED should turn OFF and
the speaker (if connected) should sound.
Red LED
ENFORCER
®
Switch: Chime/
OFF/Alarm
Timer: 3~30 Sec.
Volume:0 ~ max.
Switch
Wall mount hole
Bracket
mounting
holes
Wiring: (one speaker, no counter)
W
e
m
e
c
l
o
Other possible applications: Offices, stores, schools, warehouse, vehicle detection, etc.
Garage
door


Sample Installations:
Main
entrance
door
Store front door
Optional Accessories:
E-931ACC-RC1Q
Round Reflector
82 x 9 mm
E-931ACC-CQ
Digital Counter
(with 32ft wire)
E-931ACC-HR1Q
Reflector Hood for
Round/Square Reflectors
Wiring: (with optional counter and second speaker)
Reflector
Sensor
Adaptor
Input
Up to 22' (7m)
Speaker
ENF ORCER
®
Counter (optional)
Speaker (optional)
ENF ORCER
®
Input
Output
Output
NOTE: a) When adding a 2nd speaker. If the application distance between speakers exceed 33 ft. (10m),
then a power adaptor is required for the 2nd speaker.
b) When there are 2 devices added to the first speaker, such as a 2nd speaker & a counter.
Then a second power adaptor is required for the 2nd speaker even when the distance is within 33 ft. (10m)
c) Speaker and counter uses a standard 1/8" stereo jacks.
E-931ACC-SQ
Speaker/Electronic Chime
(with 32ft wire)
E-931ACC-BLS8Q
Door Frame Bracket
EN FORCER
®
Specifications:
Troubleshooting:
Dimensions:
PITSW3
®
E-931CS22RRCQ
Retro-Reflective Photoelectric Entry Alert System
22' (7 m)
Sensor: 9-15 VDC, Chime: 9-15 VDC
100mA Max.
30mA
IR LED
-4
0
F (-20
0
C) ~ 122
0
F (50
0
C)
~1 sec. for Chime, 30 sec. for Alarm
Adjustable from 0 ~ 90 dB at 1m (max.)
Adjustable 3~30sec. for alarm
Chime / Off /Alarm (Select by switch)
All Included
Model Number
Type
Sensing Range
Voltage Supply
Total Current Consumption
Stand-by Current
Light Source
Ambient Temperature
Speaker Response Time
Speaker Volume
Alarm Time Range
Speaker Output
Mounting Brackets
Red LED does not turn on.
1) Reflector and/or sensor is misaligned.
2) No power.
1) Adjust the reflector and/or sensor for
proper alignment
2) Check power adapter and cable.
Sensor does not detect the object. Sensor not aligned properly.
Change the angle of the sensor or
reflector.
Trouble Remedy(s)Possible Origin(s)
NOTICE:
The information and specifications printed in this manual are current at the time of publication. However,
the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right
to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2016 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or
in part, without the written permission of SECO-LARM.
SECO-LARM
®
U.S.A., Inc.,
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999
Fax: 949-261-7326 Website: www.seco-larm.com E-mail: [email protected]
WARRANTY:
ENFORCER Photobeam Sensors are warranted against defects in material and workmanship while
used in normal service for a period of one (1) year from the date of sale to the original customer. Our obligation is
limited to the repair or replacement of any defective part if the unit is returned, transportation pre-paid, to SECO-LARM.
5
/
16
" (8.2mm)
2
7
/
16
" (62mm)
2
13
/
16
" (71mm)
2
3
/
8
" (60mm)
1
3
/
8
"
(35mm)
1
3
/
16
" (30mm)
2
13
/
16
" (71mm)
MiE931CS22RRCQ_181008.pdf
2
1
/
64
" (51.3mm)
2
25
/
64
" (60.3mm)
E-931CS22RRCQ
Range: 22ft. (7m)
Retro-Reflective Photoelectric
Sensor Entry Alert System
Sensor
Caution:
ENFORCER
®
Features:
••
••
Retro-reflective photoelectric sensor.
••
••
Range: Up to 22 feet (7m).
••
••
Perfect for monitoring an entrance, or for counting
foot traffic with optional counter.
••
••
Will make “ding-dong” sound or alarm sound
when the beam is interrupted.
••
••
Speaker volume can be adjusted or turned off.
••
••
When in alarm mode, sounding time is adjustable
from 3 to 30 seconds.
This sensor was not designed to prevent bodily injury or loss of life.
Use of this sensor in certain security applications may be regulated by local laws or codes.
SECO-LARM is not responsible for compliance with such laws or codes.
••
••
All components plug into each other.
No hard wiring required.
••
••
Optional counter available (E-931ACC-CQ).
••
••
Optional second speaker available (E-931ACC-SQ).
••
••
Includes the following:
Retro-reflective photoelectric sensor.
Reflector.
Speaker/electronic chime.
Power adapter.
Included:
E-931ACC-BLS4Q
Sensor Bracket
E-931ACC-BLR2Q
Reflector bracket
Power
Adapter
E-931ACC-SQ
Speaker/Electronic Chime
ENF ORCER
®
E-931CS22SQ
Transmitter/Receiver
EN FORC ER
®
E-931ACC-R2Q
Reflector
2
1
/
64
" (51.3mm)
2
1
/
64
" (51.3mm)
2
25
/
64
" (60.3mm)
INSTALLATION MANUAL
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

SECO-LARM E-931CS22RRCQ Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI