Kichler Lighting 44344WNWLED User manual

Type
User manual
IS-44344-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
1) Pass wire through stems[A] and small threaded tubes[B]
and screw stems into couplings[G] on top of xture body[H].
NOTE: Thread locking compound must be applied to all stem
threads as noted with symbol (4) to prevent accidental
rotaon of xture during cleaning,relamping, etc.
2) Pass xture wire through remaining stems and screw stems
together.
3) On one side of xture, pass xture wire through one small
threaded pipe[K]. Screw each small threaded pipe onto top of
stem on each side.
4) On one side of xture, pass xture wires through each hole in
canopy[F]. Lower canopy down towards stems. Pass each hole
in canopy over end of each threaded pipe on top of stems.
5) On one side of xture, pass xture wire through
lockwasher[P]. Thread lockwasher onto end of threaded
pipe protruding from inside canopy. Pass xture wire through
hexnut[Q]. Thread hexnut onto end of threaded pipe.
6) Repeat to other threaded pipe.
7) Aach mounng plate[D] to outlet box[C] using the strap
mounng screws[E]. Mounng strap can be adjusted to suit
posion of xture.
8) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a hole
and two raised dimples, wrap ground wire from outlet
box around green ground screw, and thread into hole.
b) On xtures where a cupped washer is provided, aach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounng strap.
If xture is provided with ground wire, connect xture ground
wire to outlet box ground wire with wire connector (not
provided.) aer following the above steps. Never connect
ground wire to black or white power supply wires.
9) Cut the wire to length for wiring and make wire connecons
to the driver aer stems[A] have been installed per wiring
Diagram “A’ in view above the canopy[F] using supplied wire
nuts[R].
10) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply Wire
to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or Black
without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other than
green) with silver conductor
*Note: When parallel wire (SPT 1 &
SPT 2) are used. The neutral wire
is square shaped or ridged and the
other wire will be round in shape or
smooth (See illus.)
Neutral Wire
11) Push xture to ceiling, carefully passing mounng screws
through holes in canopy. NOTE: Be certain wires do not get
pinched between mounng strap and canopy.
12) Secure xture to ceiling with the four (4) at head machine
screws[L] through the sides of the canopy as shown.
13) Install the six (6) glass spacers[M] with pads on the top as
shown.
14) Carefully install the glass[N] by raising up to the sides and
using the decorave knobs[O] secure the glass into place as
shown.
Installaon Instrucons – Loop/Chain Link Mount
1) Follow steps 1 and 4 from Rigid Stem Mount Instrucons.
2) Thread one small threaded pipe[K] into end of each small
loop[J].
3) Pass xture wire through rst loop. Thread rst loop onto end
of each last stem.
4) On one side of xture, pass xture wire through second loop
and through hole in canopy[F]. Pass threaded pipe at end of
second loop through hole in canopy.
5) Pass xture wire through lockwasher[P]. Thread lockwasher
onto end of threaded pipe protruding from inside canopy.
6) Pass xture wire through hexnut[Q]. Thread hexnut onto end
of threaded pipe.
7) On other side of xture, pass xture wire through second
loop and through hole in canopy. Pass threaded pipe at end of
second loop through hole in canopy.
8) Pass xture wire through lockwasher. Thread lockwasher onto
end of threaded pipe protruding from inside canopy.
9) Pass xture wire through hexnut. Thread hexnut onto end of
threaded pipe.
10) Aach locking link[I] to small loop at end of each stem and to
each loop on canopy.
11) Follow steps 7 - 14 from Rigid Stem Mount Instrucons.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons – Rigid Stem Mount
[A] Stems
[B] Small
Threaded
Tubes
[C] Outlet Box
[D] Mounting
Plate
[E] Strap
Mounting
Screws
[F] Canopy
[G] Couplings
[H] Fixture Body
[I] Chain Locking
Link
[J] Small Loop
[K] Small
Threaded Pipe
[L] Flat Head
Screws
[M] Glass Spacers
[N] Glass
[O] Decorative
Knobs
[P] Lockwasher
[Q] Hexnut
[R] Wire nuts
AC INPUT
N:WHITE L:BLACK
DC OUTPUT
DC+:RED
DC-:BLUE
AC INPUT
N:WHITE L:BLACK
DC OUTPUT
DC+:RED
DC-:BLUE




WIRING DIAGRAM "A"
INPUT:
120Vac, 50/60HZ
L
C
D
E
R
R
Q
P
F
K
J
I
O
N
M
A
B
G
This device complies with part 15 of the FCC Rules. Operaon is
subject to the following two condions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including
interference that may cause undesired operaon.
Note: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protecon
against harmful interference in a residenal installaon. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instrucons,
may cause harmful interference to radio communicaons. However,
there is no guarantee that interference will not occur in a parcular
installaon. If this equipment does cause harmful interference to
radio or television recepon, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separaon between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for
help.
FCC Informaon:
IS-44344LED-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
1) Pass wire through stems[A] and small threaded tubes[B]
and screw stems into couplings[G] on top of xture body[H].
NOTE: Thread locking compound must be applied to all stem
threads as noted with symbol (4) to prevent accidental
rotaon of xture during cleaning,relamping, etc.
2) Pass xture wire through remaining stems and screw stems
together.
3) On one side of xture, pass xture wire through one small
threaded pipe[K]. Screw each small threaded pipe onto top of
stem on each side.
4) On one side of xture, pass xture wires through each hole in
canopy[F]. Lower canopy down towards stems. Pass each hole
in canopy over end of each threaded pipe on top of stems.
5) On one side of xture, pass xture wire through
lockwasher[P]. Thread lockwasher onto end of threaded
pipe protruding from inside canopy. Pass xture wire through
hexnut[Q]. Thread hexnut onto end of threaded pipe.
6) Repeat to other threaded pipe.
7) Aach mounng plate[D] to outlet box[C] using the strap
mounng screws[E]. Mounng strap can be adjusted to suit
posion of xture.
8) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a hole
and two raised dimples, wrap ground wire from outlet
box around green ground screw, and thread into hole.
b) On xtures where a cupped washer is provided, aach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounng strap.
If xture is provided with ground wire, connect xture ground
wire to outlet box ground wire with wire connector (not
provided.) aer following the above steps. Never connect
ground wire to black or white power supply wires.
9) Cut the wire to length for wiring and make wire connecons
to the driver aer stems[A] have been installed per wiring
Diagram “A’ in view above the canopy[F] using supplied wire
nuts[R].
10) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply Wire
to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or Black
without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other than
green) with silver conductor
*Note: When parallel wire (SPT 1 &
SPT 2) are used. The neutral wire
is square shaped or ridged and the
other wire will be round in shape or
smooth (See illus.)
Neutral Wire
11) Push xture to ceiling, carefully passing mounng screws
through holes in canopy. NOTE: Be certain wires do not get
pinched between mounng strap and canopy.
12) Secure xture to ceiling with the four (4) at head machine
screws[L] through the sides of the canopy as shown.
13) Install the six (6) glass spacers[M] with pads on the top as
shown.
14) Carefully install the glass[N] by raising up to the sides and
using the decorave knobs[O] secure the glass into place as
shown.
Installaon Instrucons – Loop/Chain Link Mount
1) Follow steps 1 and 4 from Rigid Stem Mount Instrucons.
2) Thread one small threaded pipe[K] into end of each small
loop[J].
3) Pass xture wire through rst loop. Thread rst loop onto end
of each last stem.
4) On one side of xture, pass xture wire through second loop
and through hole in canopy[F]. Pass threaded pipe at end of
second loop through hole in canopy.
5) Pass xture wire through lockwasher[P]. Thread lockwasher
onto end of threaded pipe protruding from inside canopy.
6) Pass xture wire through hexnut[Q]. Thread hexnut onto end
of threaded pipe.
7) On other side of xture, pass xture wire through second
loop and through hole in canopy. Pass threaded pipe at end of
second loop through hole in canopy.
8) Pass xture wire through lockwasher. Thread lockwasher onto
end of threaded pipe protruding from inside canopy.
9) Pass xture wire through hexnut. Thread hexnut onto end of
threaded pipe.
10) Aach locking link[I] to small loop at end of each stem and to
each loop on canopy.
11) Follow steps 7 - 14 from Rigid Stem Mount Instrucons.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons – Rigid Stem Mount
[A] Stems
[B] Small
Threaded
Tubes
[C] Outlet Box
[D] Mounting
Plate
[E] Strap
Mounting
Screws
[F] Canopy
[G] Couplings
[H] Fixture Body
[I] Chain Locking
Link
[J] Small Loop
[K] Small
Threaded Pipe
[L] Flat Head
Screws
[M] Glass Spacers
[N] Glass
[O] Decorative
Knobs
[P] Lockwasher
[Q] Hexnut
[R] Wire nuts
AC INPUT
N:WHITE L:BLACK
DC OUTPUT
DC+:RED
DC-:BLUE
AC INPUT
N:WHITE L:BLACK
DC OUTPUT
DC+:RED
DC-:BLUE




WIRING DIAGRAM "A"
INPUT:
120Vac, 50/60HZ
L
C
D
E
R
R
Q
P
F
K
J
I
O
N
M
A
B
G
This device complies with part 15 of the FCC Rules. Operaon is
subject to the following two condions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including
interference that may cause undesired operaon.
Note: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protecon
against harmful interference in a residenal installaon. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instrucons,
may cause harmful interference to radio communicaons. However,
there is no guarantee that interference will not occur in a parcular
installaon. If this equipment does cause harmful interference to
radio or television recepon, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separaon between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for
help.
FCC Informaon:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Kichler Lighting 44344WNWLED User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI