MAN# 650447:A
Troubleshooting guide.
Additional troubleshooting tips on the BIM-19-2 can be found in its separate manual.
Problem Possible cause Solution
Gauge will not light up Red wire does not have Connect to a location that has power.
power.
BLACK wire is not getting Connect ground to a different location.
a good ground.
Gauge is damaged. Return gauge for repair. (see instructions)
Gauge lights up, but displays BIM-19 is not connected. Connect a BIM-19 using the power/data cable.
“NO SENDERS FOUND” BIM-19 is not powered. Check power connections on BIM-19.
Data cable is not plugged in Check both ends of the data cable.
securely.
Gauge lights up, but displays BIM-19 is not connected. Connect a BIM-19 using the power/data cable.
“BIM-19 SIGNAL ERROR” BIM-19 is not powered. Check power connections on BIM-19.
Data cable is not plugged in Check both ends of the data cable.
securely.
A BIM module other than a The ODYR-19-7 is only compatible with the
BIM-19 is connected. BIM-19.
Gauge lights up, but Sender is not connected Connect wires from sender to BIM-19
displays “EE”. to BIM-19. terminals.
Wires are crossed or shorted. Verify sender connection to BIM-19.
Wire between BIM-19 and Test and replace wire.
sender is broken.
BIM-19 is damaged. Return gauge for repair. (see instructions)
Sender is damaged. Return for replacement. (see instructions)
Gauge lights up, but Sender wire is shorted to Check wire for damaged insulation, replace
displays “--”. ground. if necessary.
Wire between BIM-19 and Test and replace wire.
sender is broken.
BIM-19 is damaged. Return gauge for repair. (see instructions)
Sender is damaged. Return for replacement. (see instructions)
Gauge lights up, but does Loose connection on Reconnect wire going to PWR terminal.
not read correctly. power wire.
Poor sender ground. Make sure gauge and BIM are getting a solid
ground.
Poor ground connection. Move ground to different location
Incorrect sender type. Make sure sender has been replaced with
the correct type (SEN-03-9).
Gauge flashes constantly. Warning limits are not set Reset warning limits.
properly.
Vehicle has improper air Check air level and air pump.
pressure.
External warning indicator Indicator not connected Check indicator wiring connections.
does not work. properly.
Indicator does not work. Repair or replace indicator.
Gauge output has been Return gauge for repair. (see instructions)
damaged.
Gauge will not dim. BLUE wire is not connected Check wiring connections.
correctly.
Gauge is damaged. Return gauge for repair. (see instructions)
Gauge remains dim at all BLUE wire is getting power Connect BLUE wire to location that only
times. all of the time. has power when the headlights are on.
Battery is very low. Recharge or replace vehicle battery.
Gauge is damaged. Return gauge for repair. (see instructions)