LOOMFIELD INTEGRITY 9012CA

Wunderbar LOOMFIELD INTEGRITY 9012CA, 9003-D3, BLOOMFIELD INTEGRITY 9003, BLOOMFIELD INTEGRITY 9003CA, BLOOMFIELD INTEGRITY 9010, BLOOMFIELD INTEGRITY 9012, BLOOMFIELD INTEGRITY 9016, BLOOMFIELD INTEGRITY 9016EX, Decanter Style 9012D3F, Decanter Style 9016D3F Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Wunderbar LOOMFIELD INTEGRITY 9012CA Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
10 Sunnen Drive
St. Louis, MO 63143
telephone: 314-678-6336
fax: 314-781-2714
www.bloomfieldworldwide.com
p/n 2M-75815 Rev. J M601 120511
OWNERS MANUAL
for
INTEGRITY
DECANTER
COFFEE BREWERS
MODELS
9003
9010 9012
9016
Includes:
Installation
Use & Care
Servicing Instructions
Model 9016 Brewers
with optional
8900-Series Glass Decanters
601
NOTE: For your protection, please note that equipment in
this shipment was carefully inspected and packaged by skilled
personnel before leaving the factory.
Upon acceptance of this shipment, the transportation
company assumes full responsibility for its safe delivery.
IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any
visible loss or damage is noted on the freight bill
or express receipt, and that the note of loss or damage
is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY:
Regardless of the extent of the damage.
3. CONCEALED LOSS OR DAMAGE: if damage is
unnoticed until the merchandise is unpacked, notify the
transportation company or carrier immediately, and
the delivery was made to you. Be sure to retain the
container for inspection.
incurred in transit. We will, however, at your request, supply
you with the necessary documents to support your claim.
WARRANTY STATEMENT
SERVICE POLICY AND PROCEDURE GUIDE
ADDITIONAL WARRANTY EXCLUSIONS
SHIPPING DAMAGE CLAIMS PROCEDURE
1. Resetting of safety thermostats, circuit breakers,
overload protectors, or fuse replacements.
2. All problems due to operation at voltages other than
correct voltage must be the customer’s responsibility.
3. All problems due to electrical connections not made in
accordance with electrical code requirements and
wiring diagrams supplied with the equipment.
4. Replacement of items subject to normal wear, to
include such items as knobs and light bulbs. Normal
maintenance functions including adjustment of
thermostats, microswitches, and replacement of fuses
and indicating lights are not covered under warranty.
6. All problems due to mineral/calcium deposits, or
considered a preventative maintenance function and is
not covered by warranty.
All electrical equipment manufactured by BLOOMFIELD is
warranted against defects in materials and workmanship
for a period of (1 year labor, two year parts) from the date
purchaser, except that:
a. airpots carry a 30 day parts warranty only.
b. dispensers; i.e., tea and coffee carry a 90 days parts
warranty only, excludes decanters.
c. decanters are not covered by this warranty
THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN
IN LIEU OF ANY OTHER WARRANTIES, EXPRESSED
OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, WHICH ARE HEREBY EXCLUDED.
BLOOMFIELD, LLC SHALL NOT BE LIABLE FOR
INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES
OR LOSSES FROM ANY CAUSE WHATSOEVER.
This warranty is void if it is determined that upon inspection
by an authorized service agency that the equipment has
It also does not apply if the serial nameplate has been
removed or unauthorized service personnel perform service.
upon the limitations in this warranty. Seller’s obligation under
this warranty is limited to the repair of defects without charge
to the closest authorized service agency, transportation
charges prepaid, for services.
principal cities.
This warranty is valid in the United States, Canada and void
or your food service equipment dealer; or, for information and
other details concerning warranty, write to:
Service Parts Department
10 Sunnen Drive, St. Louis, MO 63143
Phone: (314) 678-6336... Fax: (314) 781-2714
7. Full use, care and manuals may or may not be sent with
each unit, only a condensed version. Please visit our
web site to download the full version.
agencies.
9. All labor shall be performed during normal working hours.
Overtime premium shall be charged to the customer.
warranted equipment. Any use of non-genuine
11. Installation, labor and job checkouts are not considered
warranty.
12. Charges incurred by delays, waiting time or operating
restrictions that hinder the service technicians ability
to perform services are not covered by warranty.
This includes institutional and correctional facilities.
xi
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
TABLE OF CONTENTS
Thank You for purchasing this
WARRANTY STATEMENT xi
SPECIFICATIONS 1
FEATURES & OPERATING CONTROLS 2
PRECAUTIONS & GENERAL INFORMATION 3
AGENCY APPROVAL INFORMATION 3
INSTALLATION INSTRUCTIONS 4
OPERATION 6
BREWING COFFEE 8
CLEANING INSTRUCTIONS 9
TROUBLESHOOTING SUGGESTIONS 10
SERVICING INSTRUCTIONS 11
EXPLODED VIEWS & PARTS LISTS 18
WIRING DIAGRAMS 22
SPECIFICATIONS
1
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
MODEL STYLE VOLTS WATTS AMPS 1ø POWER SUPPLY CORD
9003
3W IN-LINE, POUR-OVER
120 1800 15 NEMA 5-15P
*9003CA 120 1500 12.5 NEMA 5-15P
9010
3W IN-LINE, FAUCET
120 2300 19 NEMA 5-20P
9012 120 1800 15 NEMA 5-15P
*9012CA 120 1500 12.5 NEMA 5-15P
9016 120/240 3800 17 NOT PROVIDED
9016EX 220-240 3800 16.5 NOT PROVIDED
FEATURES AND OPERATING CONTROLS
Fig. 1 Features & Operating Controls
2
IL1614a
HOT WATER FAUCET
(certain models)
WATER LINE CONNECTION
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
PRECAUTIONS AND GENERAL INFORMATION
WARNING: ELECTRIC SHOCK HAZARD
WARNING: INJURY HAZARD
WARNING: ELECTRIC SHOCK HAZARD
WARNING: BURN HAZARD
WARNING
CAUTION:
EQUIPMENT DAMAGE
Installation
Instructions
CAUTION:
BURN HAZARD
AGENCY APPROVAL INFORMATION
3
WARNING
WARNING
WARNING
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
C
INSTALLATION INSTRUCTIONS
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION
LEVELING THE UNIT
PLUMBER’S INSTALLATION INSTRUCTIONS
POTABLE WATER, COLD
WATER
DO NOT
IMPORTANT:
CAUTION:
EQUIPMENT DAMAGE
DO NOT
CAUTION:
UNSTABLE
EQUIPMENT HAZARD
NOTE:
4
Fig. 2 Water Supply
Installation
IL1615
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
INSTALLATION INSTRUCTIONS (continued)
NOTE:
WARNING:
SHOCK HAZARD
IMPORTANT:
IMPORTANT:
water hammer arrester in
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
IMPORTANT:
Models 9003, 9010 & 9012
IMPORTANT:
Models 9016
IMPORTANT:
Models 9016EX
IMPORTANT:
Fig. 3 115/240 Volt Terminal Block
IL1616
WARNING
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
OPERATION
Fig. 4 Brewer Operation Diagram
START-UP
ON
BEFORE
THE WATER TANK MUST
BE FILLED
A.
IMPORTANT:
is NOT COVERED BY
WARRANTY
6
IL1617
IL1618
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
OPERATION (continued)
WATER HEATER
WATER FLOW
POUR-OVER FEATURE
AUTOMATIC OPERATION
HOT WATER FAUCET
OPEN.
Fig. 6 Water Flow Diagram
Fig. 5 Heat Control Diagram
7
IL1619
IL1620
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
BREWING COFFEE
CAUTION:
BURN HAZARD
CAUTION:
BURN HAZARD
CAUTION:
BURN HAZARD
NOTE:
PREPARATION
POUR-OVER OPERATION
NOTE:
EMPTY
C. AUTOMATIC OPERATION (certain models)
EMPTY
A.
Fig. 7 Brew Chamber
8
IL1605
PAPER
FILTER
BREW
CHAMBER
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
CLEANING INSTRUCTIONS
PROCEDURE: Clean Coffee Brewer
PRECAUTIONS:
FREQUENCY:
TOOLS:
INSIDE
CAUTION:
BURN HAZARD
CAUTION:
SHOCK HAZARD
IMPORTANT:
DO NOT
Fig. 8 Cleaning
9
IL1599
GASKET
SPRAY
DISK
LIFT EARS UP
TURN LEFT TO
REMOVE
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
10
TROUBLESHOOTING SUGGESTIONS
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
Water won’t heat
Brewer unplugged or circuit breaker
tripped
Check power supply cord Check /
reset circuit breaker
Thermostat set too low Set for desired temperature
Hi-Limit thermostat tripped
Allow to cool, Reset hi-limit (8786,
8788)
Damaged internal component or
wiring
Examine wiring & connectors,
thermostat and heating element,
Repair/replace as needed
Trips hi-limit safety at start-up
No Water or too little water added at
start-up energizing
Coffee level low (pour-over)
Not enough water poured in Increase water amount
Too much coffee grounds Adjust amount of grounds
Coffee level too high or low (automatic) Timer out of adjustment Adjust timer
paper per brew
Brew chamber dispense hole plugged Thoroughly clean brew chamber
Adjust coffee amount and grind
Sprays water from brew head
Spray gasket improperly installed
Check/reinstall gasket on INSIDE of
brew head
Spray disk plugged Clean spray disk
No brew (automatic)
Water supply OFF Turn water supply ON
Solenoid strainer plugged Clean strainer
Bad BREW switch Replace switch
Damaged internal component or
wiring
Examine wiring & connectors, brew
switch and solenoid Repair/replace as
needed
Faucet valve turned OFF Turn faucet valve ON
Faucet plugged Disassemble faucet, clean
Poor coffee quality
Water not hot enough
Adjust water temp 195-205ºF
supply, and replace cartridges regularly. Use a quality coffee with a consistent
roast. Use proper grind and amount of coffee per brew.
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
SERVICING INSTRUCTIONS
ACCESS PANELS
CAUTION:
SHOCK HAZARD
Fig. 9 Access Panels
11
IL1621a
SOLENOID
DOOR
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
CAUTION:
SHOCK HAZARD
NOTE:
IMPORTANT:
SERVICING INSTRUCTIONS (continued)
TEMPERATURE ADJUSTMENT
Fig. 10 Checking and Adjusting Brew Temperature
Table 1 Boiling Temperature by Altitude
12
Fig. 11 Adjust Thermostat
IL1606
IL1601
BOILING
POINT OF
WATER
ELEVATION (feet above sea level)
210
205
200
195
190
MAXIMUM
TEMPERATURE
SETTING
IDEAL
BREWING
TEMPERATURE
TEMP ( F)
IL1602
ELEVATION (meters above sea level)
100
0
150
300
450
600
750
900
1,050
1,200
1,500
1,650
1,800
1,950
1,350
97
94
91
88
BOILING
POINT OF
WATER
MAXIMUM
TEMPERATURE
SETTING
IDEAL
BREWING
TEMPERATURE
TEMP ( C)
IL1607
DIAL-TYPE
THERMOMETER
IN VENT HOLE
THERMOSTAT
ADJUSTING
SHAFT
TANK LID
ASSEMBLY
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
SERVICING INSTRUCTIONS (continued)
13
IMPORTANT:
IMPORTANT:
DO NOT OVER-TIGHTEN
IMPORTANT:
TIMER ADJUSTMENT
REMOVE TANK LID ASSEMBLY
OFF OFF
REPLACE THERMOSTAT
OFF OFF
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
SERVICING INSTRUCTIONS (continued)
14
REPLACE HEATING ELEMENT
REPLACE SOLENOID
NOTE
IMPORTANT:
CLEAN SOLENOID SCREEN
OFF OFF
OPEN END FIRST
Fig. 12 Clean Strainer Screen
Fig. 11 Remove Faucet
Supply from Solenoid
IMPORTANT:
STRAINER
SCREEN
WASHER
WATER INLET
FITTING
IL1608
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
SERVICING INSTRUCTIONS (continued)
IMPORTANT:
NOTE:
REPLACE TIMER ASSEMBLY
REPLACE HOT WATER FAUCET COIL
REPAIR HOT WATER FAUCET
REPLACE BREW READY LIGHT or BREW BUTTON
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
CAUTION:
CHEMICAL
BURN HAZARD
This
IMPORTANT:
IMPORTANT: DO NOT al
NOTE:
PROCEDURE: Delime the Water Tank
SERVICING INSTRUCTIONS (continued)
16
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
NOTE:
SERVICING INSTRUCTIONS (continued)
17
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
18
EXPLODED VIEW & PARTS LIST
HOT WATER TANK ASSEMBLY
IL1622
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
ITEM PART NO. DESCRIPTION USED ON
13 2C-70134 HOLD-DOWN STRAP 9010, 9012(CA), 9016(EX)
14 2C-73457 NUT, HEX 8-32 KEPS 9010, 9012(CA), 9016(EX)
50
WS-8512-51 THERMOSTAT (BLACK BODY - INCL. SEAL & MOUNTING SCREWS)
9010, 9012(CA), 9016(EX)
WS-86280 THERMO (ALT) (GRAY BODY - INCL. TUBE & MOUNTING SCREWS)
52 2C-70174 SEAL WASHER, THERMO CAP TUBE (ONLY) 9010, 9012(CA), 9016(EX)
54 2I-70147 TANK COVER GASKET 9010, 9012(CA), 9016(EX)
55 2C-70175 NUT HEX 1/2-20 BRASS 9010, 9012(CA), 9016(EX)
56 2I-70152 SEAL GASKET, ELEMENT OR WATER COIL 9010, 9012(CA), 9016(EX)
57 2C-70151 NUT HEX 7/16-20 BRASS
58 2N-70149 HOT WATER COIL 9010, 9012(CA), 9016(EX)
59 2K-70101 TUBE, BASIN OUTLET/TANK INLET, SILICONE 9010, 9012(CA), 9016(EX)
60 2V-70102 TUBE, VENT, SILICONE 9010, 9012(CA), 9016(EX)
61 2K-70103 ELBOW, TANK OUTLET, SILICONE 9010, 9012(CA), 9016(EX)
62 A6-70142 TAN COVER, PLATE ONLY, 8 HOLES 9010, 9012(CA), 9016(EX)
63
2T-47499 THERMOSTAT, HI-LIMIT 9012(CA)
2T-70716 THERMOSTAT, HI-LIMIT RESET 9010, 9016(EX)
66 2V-70144 WATER INLET TUBE 9010, 9012(CA), 9016(EX)
66a 2C-70146 NUT, HEX 4-40 SS 9010, 9012(CA), 9016(EX)
66b 2C-70146 SCREW 4-40 x 1 PAN HEAD 9010, 9012(CA), 9016(EX)
67
2N-70167UL HEATING ELEMENT (120V, 1200W) 9012CA
2N-70143UL HEATING ELEMENT (120V, 1500W) 9010, 9012
2N-70715UL HEATING ELEMENT (240V, 3500W) 9016, 9016EX
2N-70173UL HEATING ELEMENT (240V, 1800W) 230V Units
68 2D-70110 TANK BODY 9010, 9012(CA), 9016(EX)
70 A6-70625 BRACKET, HI LIMIT THERMOSTAT 9010, 9016 (EX)
TANK COVER ASSEMBLY
WS-8541WF-300
INCLUDES: MOUNTED THERMO, HI-LIMIT, 120V 1500W HEATING
ELEMENT & HOT WATER COIL)
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer
/