5
1.4 Specifications:
- electrical parameters (tab.3)
- mechanical parameters (tab.4)
- operation safety (tab.5)
- operating parameters (tab.6)
Electrical parameters (tab. 3).
Mains supply 176÷264V AC
Current up to 0.95A@230VAC
Power frequency 50÷60Hz or DC
Supply power 100W max.
Efficiency 80%
Output voltage 13,8V DC – buffer operation
9,5V÷13,8V DC – battery-assisted operation
Output current
6 A + 1A battery charge
5 A + 2A battery charge
Output current t
AMB
<30°C 6,0 A + 1,0A battery charge - refer to chart 1
5,0 A + 2,0A battery charge - refer to chart 1
Output current t
AMB
=40°C 4,9 A + 1,0A battery charge - refer to chart 1
3,9 A + 2,0A battery charge - refer to chart 1
Voltage adjustment range 12÷14VDC
Ripple 120mV p-p max.
Battery charge current 1A/2A max. @ 65Ah (± 5%)
Short-circuit protection SCP electronic
Overload protection OLP PTC polymer fuse
Overvoltage protection OVP
U>115% ÷ 150% of the output voltage (set), power
cut off, automatic return
Excessive discharge protection UVP U<9,5 V (± 5%) –
disconnect of connection battery
LED indication:
- AC diode indicating AC power status
- AUX diode indicating DC power status at
the PSU output
- red, normal status – on, failure: off
- green, normal status – on, failure: off
Technical outputs:
- TAMPER indicates enclosure opening
- microswitch, NC contacts (enclosure closed),
0,5A@50V DC (max.)
Mechanical parameters (tab. 4).
Enclosure dimensions 405 x 355 x 170+8 (400 x 350 x 170) (WxHxD)
Fixation see figure 2
Fitting battery 65Ah/12V (SLA) max.
Net/gross weight 5,95kg/ 6,35kg
Enclosure colour RAL 9003
Closing Cheese head screw x 2 (at the front), (lock assembly possible)
Connectors Power-supply: Φ0,63-2,50 (AWG 22-10)
Outputs: Φ0,63-2,50 (AWG 22-10), battery output BAT: 6,3F-2,5
TAMPER output: wires
Notes The enclosure does not adjoin the assembly surface so that cables can be led
Operation safety (tab.5).
Protection class PN-EN 60950-1:2007 I (first)
Protection grade PN-EN 60529: 2002 (U) IP20
Electrical strength of insulation:
- between input and output circuits of the PSU (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100 MΩ, 500V/DC