Briteq Led Power Beam BRITEQ Owner's manual

Category
Stroboscopes & disco lights
Type
Owner's manual

Briteq Led Power Beam BRITEQ is a versatile lighting fixture suitable for indoor or outdoor use, providing wash or effect lighting for architectural, stage, or nightclub applications. It can also be used for signage and advertising, thanks to its dynamic functions accessible via DMX512 control. Multiple units can be connected for larger applications.

The fixture features RGB dimming, strobe effects, and automatic programs, all controllable via DMX512 or the included PiX controller.

Briteq Led Power Beam BRITEQ is a versatile lighting fixture suitable for indoor or outdoor use, providing wash or effect lighting for architectural, stage, or nightclub applications. It can also be used for signage and advertising, thanks to its dynamic functions accessible via DMX512 control. Multiple units can be connected for larger applications.

The fixture features RGB dimming, strobe effects, and automatic programs, all controllable via DMX512 or the included PiX controller.

PART 5 USING THE CONTROLLER.............................................24.
5.1--BASIC.......................................................................................25.
5.3--MENU.......................................................................................27.
5.2--SETTING UP.............................................................................27.
PART 4 USING A DMX512 CONTROLLER....................................19.
4.1--BASIC ADDRESSING.................................................................20.
4.2--CHANNEL ASSIGNMENT............................................................20.
4.3--BASIC INSTRUCTIONS FORDMX512 OPERATION......................23.
PART 3 DISPLAY PANEL OPERATION.......................................13.
3.1--BASIC........................................................................................14.
3.2--MENU........................................................................................15.
3.3--CREATING ASTATIC COLOR......................................................16.
3.4--DMX512 SETTINGS....................................................................16.
3.5--ACTIVATINGAN AUTOPROGRAM..............................................17.
3.6--CHANGING THE SETTINGS........................................................17.
3.7--ACTIVATE THE PASSWORD.......................................................18.
3.8--POWER ON/OFF.........................................................................18.
3.9--RGB CHANNEL MODEL .............................................................18.
TABLE OF CONTENTS..................................................................I.
PART 1 PRODUCT (GENERAL)....................................................1.
1.1--PRODUCT INTRODUCTION.........................................................2.
1.2--PRODUCT FEATURES.................................................................2.
1.3--TECHNICAL SPECIFICATIONS.....................................................3.
1.4--PHOTOMETRIC DATA..................................................................4.
1.5--SAFETY WARNING......................................................................5.
PART 2 INSTALLATION...............................................................6.
2.1--MOUNTING...................................................................................7.
2.3--SETTING UPWITH A DMX512 CONTROLLER.................................8.
2.3-1--DMX512 ADDRESSING WITHOUTID ADDRESSING......................................8.
2.3-2--DMX512 ADDRESSING WITHID ADDRESS..................................................8.
2.4--SETTING UPWITH THE PiXCONTROLLER...................................9.
2.4-1--SINGLE ROWAPPLICATION.........................................................................9.
2.4-2--STANDARD BLOCKAPPLICATION..............................................................10.
2.4-3--REPEAT ROW BLOCKAPPLICATION...........................................................11.
2.5--OPERATIONWITH DMX512 VsPiX CONTROLLER.......................12.
2.2--POWER CONNECTION..................................................................7.
5.4--CUSTOM PROGRAM..................................................................28.
5.5--PLAY SCHEDULE......................................................................29.
5.6--CLOCK.....................................................................................29.
5.7--SCHEDULE...............................................................................29.
5.8--SETTINGS................................................................................30.
5.9--ACTIVATETHE PASSWORD.......................................................31.
5.10--PIX CONTROLLEREXTERNAL CONTROL VIADMX512.............31.
5.11--MAINTENANCE........................................................................33.
ABLE OF CONTENTS
T
TABLE OF CONTENTS I
2007.03.10
1
1.1 PRODUCT INTRODUCTION
1.2 PRODUCT FEATURES
1.3 TECHNICAL SPECIFICATIONS
1.4 PHOTOMETRIC DATA
1.5 SAFETY WARNING
PRODUCT (GENERAL)
1 PRODUCT(GENERAL) 1
2007.03.10
1.1 PRODUCT INTRODUCTION
This product is designed for indoor or outdoor use. Suitable applications include wash or
effect lighting for architectural, stage or nightclub applications. This product can also be
installed for use in signage and advertising using the dynamic functions available with
DMX512 control. Direct input of DMX512 signal allows the units to be controlled from any
DMX512 controller. This product can be operated as a single unit or in multiple units for
large applications.
The specially developed controller that allows the product to be controlled independent of
the DMX512 controllerenables the userto create andedit a widerange of customprograms.
All programs can be touch-button displayed or scheduled to START and END at scheduled
times. When programs have been created or edited in the controller, it is also possible to
trigger these programs using the DMXIN function when connected to a DMX512 controller.
1.2 PRODUCT FEATURES
LED FIXTURE
* RGB Dimmer 0-100%
* Strobe
* Automatic programs
* IP65 protection rating
* LED display
* Display control 'lock-out'
* DirectDMX512 input
* Independant IDaddress
* Lightweight aluminium casing
* RGB Dimmer 0-100%
* Strobe
* Clock & Timer
* Automaticprograms (wash &effect)
* Custom programs
* Program Schedule
* LCD display
* Display control 'lock-out'
* DirectDMX512 input
* Lightweight plastic casing
PiX CONTROLL ER
1 PRODUCT(GENERAL) 2
2007.03.10
1.3 TECHNICAL SPECIFICATIONS
CONTR OLLER
LED MODULE
Dimensions
LED MODULE:
Voltage
Rated Power
IP65 protection rating
36pcs (12 xRED / 12x GREEN / 12 x BLUE)
Weight
LED/Unit
Output/LED
LED Beam Angle
Cooling
IP
1W
15 (30 Optional)
Direct air convection
235 x 165x 300mm
4Kg
90~250V...50/60Hz
65W
Dimensions
Weight
CONTROLLER:
Voltage
Rated Power
IP33 protection rating
180 x 125x 49mm
0.7Kg
1.5W
IP
220~240V, 50/60Hz......100~120V, 50/60Hz
1 PRODUCT(GENERAL) 3
2007.03.10
235mm
165mm
Environment Temperature
-20 ~40
1.4 PHOTOMETRIC DATA
PHOTOMETRIC DATA
WHITE
1
2
3
0
1
2
3
2(0.52) 4(1.05) 6(1.57) 8(2.10)
10Distance(m)
(2.60Diameter(m))
2750
700 320 190 145 LUX
RED
1
2
3
0
1
2
3
2(0.52) 4(1.05) 6(1.57) 8(2.10) 10Distance(m)
(2.60Diameter(m))
1145
290 130 72 50 LUX
GREEN
1
2
3
0
1
2
3
2(0.52) 4(1.05) 6(1.57) 8(2.10) 10Distance(m)
(2.60Diameter(m))
1763
570 270 158 128 LUX
BLUE
1
2
3
0
1
2
3
2(0.52) 4(1.05) 6(1.57) 8(2.10) 10Distance(m)
(2.60Diameter(m))
307
98 46 27 22 LUX
1 PRODUCT(GENERAL) 4
2007.03.10
1.5 SAFETY WARNING
IMPORTANT
ALWAYS READ THE USER MANUAL BEFORE OPERATION.
PLEASE CONFIRM THATTHE POWER SUPPLYSTATED ON THE
PRODUCT IS THE SAME AS THEMAINS POWER SUPPLYIN YOUR
AREA.
This product must be installed by a qualified professional.
Always operate the equipment as described in the user manual.
A minimum distance of 0.5m must be maintained between the equipment and
combustible surface.
The product must always be placed in a well ventilated area.
Always make sure thatthe equipment is installed securely.
DO NOT stand close to the equipment and stare directly into the LED light
source.
Always disconnect the power supply before attempting and maintenance.
Always make sure that the supporting structure is solid and can support the
combined weight ofthe products.
The earth wire must always be connected tothe ground.
Do not touchthe power cablesif your handsare wet.
ATTENTION
This product leftthe place ofmanufacture in perfect condition. In order to
maintain this condition and for safe operation, the user must always follow the
instructions and safety warnings described in this user manual.
Avoid shaking or strong impactsto any partof the equipment.
Make sure thatal parts ofthe equipment arekept clean andfree of dust.
Always make sure that the power connections areconnected correct and
secure.
If there is any malfunction of the equipment, contact your distributor
immediately.
When transferring the product, it is advisable to use theoriginal packaging in
which the productleft the factory.
Shields, lenses or ultraviolet screens shallbe changed ifthey have become
damaged tosuch an extent that their effectivenessis impaired.
The lamp (LED) shall be changed if ithas become damaged or thermally
deformed.
1 PRODUCT(GENERAL) 5
2007.03.10
2
2.1 MOUNTING
2.2 POWER CONNECTIONS
2.3 SETTING UP WITH A DMX512 CONTROLLER
2.3-1 DMX512 ADDRESSING WITHOUTID ADDRESSING
2.3-2 DMX512 ADDRESSING WITH ID ADDRESS
2.4 SETTING UP WITH THE PiX CONTROLLER
2.4-1 SINGLE ROW APPLICATION
2.4-2 STANDARD BLOCK APPLICATION
2.4-3 REPEAT ROW BLOCK APPLICATION
2.5 OPERATION: DMX512 Vs PiX CONTROLLER
INSTALLATION
6
2007.03.10
2 INSTALLATION
2.1 MOUNTING
HANGING
UPRIGHT
The LED PAR can be mounted in an upright or
sitting position usingthe supporting brackets.
The LED PAR can be mounted in a hanging position using
the supporting bracket. The bracket should be secured to
the mounting truss or structure using a standard mounting
clamp. Please note that when hanging the unit a safety
cable should also be used.
@ 220V:40 units may be connected in series
@120V: 20units may be connected in series
The LED MODULE can be mounted at any angleand in any
position. It ispossible to furtheradjust the angleof the LED
MODULE using the two adjustment knobslocated on the side of
the fixture.
2.2 POWER CONNECTIONS
7
2007.03.10
2 INSTALLATION
2.3 SETTING UP WITH A DMX512
CONTROLLER
2.3-1 DMX512 ADDRESSING WITHOUT ID ADDRESSING
The figure above shows a simple DMX512
layout with thestarting address of the first
unit setat 1, with the second set at 10 and
so on... (Note that when used in this way,
the CH8 IDfunction must be inactive (CH8=0))
DMX512
CONTROLLER
Connect the DMX512controller to theunits in series.
Each unit has 9 DMX channels so theDMX Addresses should increase by increments of
9 (e.g. 1,10,19,28...)
The ID addresshas not beenset so therefore when usingthe controller CH8must
be inactive (CH8=0 ).
Each DMX Address may beused as many times as required.
Any DMX address inthe range from 001 to 500 may beused.
2.3-2 DMX512 ADDRESSING WITH ID ADDRESS
Connect the DMX512 controller to the units in series
Each unit has 9 DMX channels so theDMX Addresses should increase by increments of
9 (e.g. 1,10,19,28...)
Each DMX Address may beused as many times as required.
Any DMX address inthe range from 001 to 500 may be used.
Each DMX addressmay carry upto 66 separateID addresses.
ID should be set in the menu on each unit in ascending values
(i.e. 1,2,3...)
ID addressesare accessible from Ch8 on the DMX512 controller.
Example:
8
2007.03.10
2 INSTALLATION
DMX Addr.1 DMX Addr.10 DMX Addr.19
DMX512
CONTROLLER
Example:
The figure above showsa simple DMX layout
which has usedthree units ateach DMX address.
The three unitshave different ID addresses which
allows the user to collectively control the whole
group ofunits at that DMX address by setting
CH8 to 0, or to control each unit independently by
first selecting the DMX address and then byusing
CH8 to locatethe target IDaddress.
2.4 SETTING UP WITH THE PiX
CONTROLLER
2.4-1 SINGLE ROW APPLICATION
Connect the fixturesto the PIXCONTROLLER in series.
ID Address should be set in the Id menu on each unit in ascending values
(i.e. 1,2,3...Not required for WASH programs).
When using thePIX CONTROLLER with the fixtures there isno need toset the DMX
address.
When usingthe Effect programs it is important to set the Range of fixtures in the
Settings menu of the PIXCONTROLLER.
Example:
In the figure above the PIX controller is connected inseries to 4 units with corresponding
ID addresses from 1to 4. In order to activatethe Effect programs in the PIXCONTROLLER,
the Range must be setto 004 in the Settings menu of the PIX CONTROLLER.
CONTROLLER
MODE SETUP UP DOWN
9
2007.03.10
2 INSTALLATION
DMX Addr.1
ID Addr.1
DMX Addr.1
ID Addr.2
DMX Addr.1
ID Addr.3
DMX Addr.10
ID Addr.1
DMX Addr.10
ID Addr.2
DMX Addr.10
ID Addr.3
ID Addr.1 ID Addr.2 ID Addr.3 ID Addr.4
Connect the fixtures to the PIX CONTROLLER in series in the direction that is required.
ID Address should be set in the Id menu on each unit in ascendingvalues
(i.e. 1,2,3...Not required for WASH programs).
When usingthe Effect programs it is important to set the Range of fixtures in the
Settings menu of the PiX CONTROLLER.
2.4-2 STANDARD BLOCK APPLICATION
In the figure above the PiX controller is connected in series to 9 units with corresponding
ID addresses from 1to 9. In order to activatethe Effect programs inthe
PIX CONTROLLER, the Range must be setto 009 in the Settings menu of
the PIX CONTROLLER. (Note: it ispossible to create differentkinds of effects by changing
the direction andposition of IDAddresses)
10
2007.03.10
2 INSTALLATION
Example:
CONTROLLER
MODE SETUP UP DOWN
ID Addr.1 ID Addr.2 ID Addr.3
ID Addr.6ID Addr.5ID Addr.4
ID Addr.7 ID Addr.8 ID Addr.9
In the figure above the PIXcontroller is connected in series to 9 fixtures with each row comprising
of 3 fixtureswith corresponding IDaddresses from 1to 3. Eachrow is repeatedso that theID
addresses appear the same was as the first row. In order to activate the Effect programs in
the PIX CONTROLLER, the Range must be setto 003 in the Settings menu of the
PIX CONTROLLER.
2.4-3 REPEAT ROW BLOCK APPLICATION
Connect the fixturesto the PIX CONTROLLER inseries.
ID Address should be set in the Id menu on eachunit in ascendingorder with
each row repeated (Not required for Wash programs).
When using thePRO-a CONTROLLER withthe fixtures there is noneed to setthe DMX
address.
When usingthe Effect programs it is important to set the Range of fixtures in the
Settings menu of the Pix CONTROLLER.
11
2007.03.10
2 INSTALLATION
Example:
CONTROLLER
MODE SETUP UP DOWN
ID Addr.1 ID Addr.2 ID Addr.3
ID Addr.3ID Addr.2ID Addr.1
ID Addr.1 ID Addr.2 ID Addr.3
2.5 OPERATION: DMX512 Vs PiX
CONTROLLER
OPERATION WITH ADMX512 CONTROLLER
DMX512 ADDRESS
ID ADDRESS
DMX512 ADDRESS
ID ADDRESS
DMX512 ADDRESS
ID ADDRESS
DMX512 ADDRESS
ID ADDRESS
X
X
X
X
AVAILABLE
FUNCTIONS
BENEFITS DRAWBACKS
No need toset
up DMX Address
or IDAddress
Must locate
previosly stored
DMX Address
Advanced
WASH &
EFFECT
programming
Basic WASH
programming
Advanced
WASH &
EFFECT
programming
Units are fully controlled
from DMX512 controller
DMX Address
ID address allowsfor
less DMX channels
when programming*
Advanced fixture
mapping
Programming requires
many DMX channels
All ID addresses
must be set
All ID addressesmust
be set
Basic WASH
Programming
Only control ofall
units at thesame time
DMX address not used
Only control ofall units
at the sametime
All ID Addresses
must be set
All ID Addresses
must be set
Play WASH auto
programs, Basic
CUSTOM
programming &
Schedule play
Play WASH auto
programs, Basic
CUSTOM
programming &
Schedule play
No need toset up
DMX Address or
ID Address
Play WASH &
EFFECT auto
programs, Advanced
CUSTOM
programming &
Schedule play
Play WASH &
EFFECT auto
programs, Advanced
CUSTOM
programming &
Schedule play
DMXAddressnotused
Controlspeedand time of
all WASH &
EFFECT programs
Create powerful
CUSTOM programs
Schedule play
Trigger autoprograms with
DMX IN
DMXAddressnotused
Controlspeedand time of
all WASH &
EFFECT programs
Create powerful
CUSTOM programs
Schedule play
Trigger autoprograms with
DMX IN
OPERATION WITH THE PiX CONTROLLER
DMX512 ADDRESS
ID ADDRESS
DMX512 ADDRESS
ID ADDRESS
DMX512 ADDRESS
ID ADDRESS
DMX512 ADDRESS
ID ADDRESS
X
X
X
X
AVAILABLE
FUNCTIONS
BENEFITS DRAWBACKS
12
2007.03.10
2 INSTALLATION
3
3.1 BASIC
3.2 MENU
3.3 ACTIVATING AUTO PROGRAMS
3.4 DMX512 SETTINGS
3.5 ID ADDRESS
3.6 EDITING CUSTOM PROGRAMS
3.7 SPECIAL SETTINGS
3.8 ACTIVATE THE PASSWORD
3.9 RGB CHANNEL MODEL
DISPLAY PANEL OPERATION
13
2007.03.10
3 DISPLAY PANEL OPERATION
3.1 BASIC
The LED fixtureis mounted witha LCD displayand 4 controlbuttons.
MENU SET UP
DOWN
enter the currently selected menu or confirm the current function value
scroll 'UP' through the menulist or increase the valueof the current function
scroll'DOWN'throughthemenulist ordecrease thevalueof thecurrentfunction
scroll through the mainmenu or return to the main menu
UPSET DOWNMENU
POWER O UTPOWER I N
DMX IN DMX OUT
14
2007.03.10
3 DISPLAY PANEL OPERATION
3.2 MENU
MENU
AUTO AT.01
AT.02
AT.10
PR.C1
PR.C2
PR.C10
dMX
d 001 512
Id
I 001 IO66
R. 0 255
G. 0 255
B. 0 255
S. 0 255
T. 0 255
F. 0 255
Edit
PR.C1
PR.C2
PR.C3
PR.C4
PR.C5
PR.C6
PR.C7
PR.C8
PR.C9
PR.C10
rEd
GrEn
bluE
Strb
TInE
FAdE
SC.01
SC.02
SC.30
SET UPLd
PASS
***
Send
End
REST
PASS
***
rEST
PASS
ARC
On
RGb
OFF
15
2007.03.10
3 DISPLAY PANEL OPERATION
3.3 ACTIVATING AUTO PROGRAMS
3.4 DMX512 SETTINGS
MENU
AUTO AT.01
AT.02
AT.10
PR.C1
PR.C2
PR.C10
dMX
d 001 512
MENU
Auto
Select the target[Auto] program andpress SET
Programs AT.01 to AT.10 are fully pre-programmed and will not be altered
by changes in EdIT mode
Programs PR.C1 to PR.10 are fully pre-programmed and can be edited
in EdIT mode
dMX
Enter the dMX mode to setthe DMXADDRESS.
16
2007.03.10
3 DISPLAY PANEL OPERATION
Id
I 001 IO66
3.5 ID ADDRESS
3.6 EDITING CUSTOM PROGRAMS
MENU
MENU
R. 0 255
G. 0 255
B. 0 255
S. 0 255
T. 0 255
F. 0 255
Edit
PR.C1
PR.C2
PR.C3
PR.C4
PR.C5
PR.C6
PR.C7
PR.C8
PR.C9
PR.C10
rEd
GrEn
bluE
Strb
TInE
FAdE
SC.01
SC.02
SC.30
Id
Enter the Id mode to setthe IDADDRESS
EdIT
Enter the EdIT mode to editthe custom programs PR.C1 to PR.10
Each custom program has 30 steps that can be edited
Each step allowsthe creation ofa scene usingRED rED , GREEN GrEn ,
BLUE bLUE , STROBE STrB , TIME TInE & FADE FAdE
17
2007.03.10
3 DISPLAY PANEL OPERATION
3.7 SPECIAL SETTINGS
3.8 A CTIVATE THE PASSWORD
MENU
SET UPLd
PASS
***
Send
End
REST
PASS
***
rEST
PASS
On
OFF
MENU
SET
Select UPLd to upload thecustom programs fromthe current MASTERunit to
the SLAVE units.
In order to activate the upload function thepassword must be entered
Password is thesame as the main accesspassword
When uploading theMASTER and SLAVE units willdisplay YELLOW
If an error occurs whenuploading the MASTERand/or SLAVE units willdisplay RED
On successful uploading of the customprograms the MASTERand SLAVE units
will display GREEN.
In order toreset custom modesto default valuesselect rEST
PASS
Enter the PASS mode to selectwhether the accesspassword is onor off.
In order toenter access passwordit is necessaryto first press SET
Access password is UP + DOWN + UP + DOWN
18
2007.03.10
3 DISPLAY PANEL OPERATION
3.9 RGB CHANNEL MODEL
ARC
RGb
MENU
RGb
Enter the RGb mode, the DMX512only receive 3channels' signal, thesequence
is channel 1 RED (0~255), channel 2 GREEN (0~255) , channel 3 BLUE
(0~255).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

Briteq Led Power Beam BRITEQ Owner's manual

Category
Stroboscopes & disco lights
Type
Owner's manual

Briteq Led Power Beam BRITEQ is a versatile lighting fixture suitable for indoor or outdoor use, providing wash or effect lighting for architectural, stage, or nightclub applications. It can also be used for signage and advertising, thanks to its dynamic functions accessible via DMX512 control. Multiple units can be connected for larger applications.

The fixture features RGB dimming, strobe effects, and automatic programs, all controllable via DMX512 or the included PiX controller.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI