Chief Manufacturing CMA-345 User manual

  • Hello! I am an AI chatbot trained to assist you with the Chief Manufacturing CMA-345 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
CHIEF MANUFACTURING INC. 8803-000019
1-800-582-6480 952-894-6280 FAX 952-894-6918 2003 Chief Manufacturing
12800 HIGHWAY 13 SOUTH, SUITE 500 www.chiefmfg.com
SAVAGE, MINNESOTA 55378 USA 01/03
INSTALLATION INSTRUCTIONS
STRUCTURAL CEILING PLATE WITH FLEX JOINTS
CMA-345
The CMA-345, Structural Ceiling Plate with Flex Joint minimizes the transfer of shock and extreme
vibration from the plate to the equipment. By using any length of standard 1 1/2” NPT pipe threaded on both
ends, or extension column, you can extend the height capabilities to meet your needs.
WARNING: IMPROPER INSTALLATION MAY RESULT IN SERIOUS PERSONAL INJURY!
When mounting Chief Manufacturing accessories, the structural system and mounting method
MUST be capable of supporting 5 times the combined weight of the total installation.
The maximum weight to be installed on the ceiling plate is 500 pounds (226.8 Kg).
Unpack and check contents:
(1) Structural Ceiling Plate CMA-345 (1) 5/16-18 Allen Set Screw
(1) 5/32” Allen Wrench
INSTALLATION INSTRUCTIONS
1. Secure ceiling plate to structural member. (SEE WARNING ABOVE) Bolt hole spacing is shown on
Figure 1.
2. Thread your standard NPT 1 1/2” pipe or extension column into ceiling plate, tighten securely.
3. . Install and securely tighten the 5/16 – 18 socket set screw.
3.13
6.25
3.25
6.50
6X %%c.38
3.36
7.25
7.25
1 1/2" NPT
Figure 1. CMA-345 Dimensions
/