Output Input
OutputVoltAmpCapacity(VA)
OutputWattCapacity(watts)
NominalOutputVoltage(s)
Supported
FrequencyCompatibility
OutputVoltageRegulation
(linemode)
Built-inUPSOutput
Receptacles
750
500
100V,110V,120V
60Hz
-13%,+15%
85-15Routlet(s)
Ratedinputcurrent
(atmaximumload)
Nominalinputvoltage(s)
supported
UPSinputconnectiontype
UPSinputcordlength()
Recommendedelectrical
service
Voltagecompatibility(VAC)
5.4A(120V),5.8A(110V),
6.4A(100V)
100VAC,110VAC,120VAC
5-15P
6
120V,15A
120
Battery Voltage Regulation
Fullloadruntime(minutes)
Halfloadruntime(minutes)
Expandable battery runtime
External battery pack
compatibility
DCSystemVoltage(VDC)
Batteryrechargerate
(includedbatteries)
Replacementbattery
cartridge(internalUPS
batteryreplacement)
Batteryaccess
10minutes(500W)
27minutes(250W)
Runtimeisexpandablewith
BP24V28-2U(limit1)or
BP24V70-3U(multi-pack
compatible)
BP24V15RT2U
24
Less than 4.5 hours from
10%to90%
RBC24-SLT
Supports battery access
and hot-swap replacement
without powering connected
equipmento
Voltageregulation
description
Overvoltage correction
Undervoltagecorrection
AutomaticVoltage
Regulation(AVR)circuits
maintain clean, regulated
computer-grade120,
110,100Vnominaloutput,
without using battery
power, during brownouts
95V(120V),87V(110V),
83V(100V)
Inputvoltagesbetween127V
and145V(120V),116and
133(110V),111and121
(100V)arereducedby12%
Voltageboostof14%
applieswheninputis95
–108(120V),87–99
(110V),83–90(100V)
LEDs Alarms and Switches Surge/Noise Suppression
LED Indicators
Alarms
Switches
9LEDsindicatelinepower,
batterypower,AVR,
overload and replace battery
status—with a 3-LED level
meter for load and battery
charge level
Audible alarm warns of
power failure condition
Includes two pushbutton
switchesforon/opower
control and self-test/
alarm cancel functions.
Also includes two dip switch
controls for setting the
nominal voltage
UPSACsuppressionjoule
rating
EMI/RFIACnoise
suppression
ACsuppressionresponsetime
Dataline suppression
570J
Yes
Instantaneous
Includes8-wireRJ45jack;
pins1,2,3and6provide
10baseTEthernetline
surge suppression with
7.5Vclamping;pins4and
5 provide single-line tel/
DSL line surge suppression
startingat260V
SPECIFICATIONS
• Line-interactiveAutomaticVoltageRegulation(AVR)
maintainsselectable120V,110Vor100Vnominaloutput
duringbrownoutsaslowas83Vandovervoltagesto145V
• Networkinterfacessupportsimultaneouscommunications
viabuilt-inUSBport,DB9serialportandSNMPWEBCARDslot
• HID-compliantUSBinterfaceenablesintegrationwith
built-in power management and auto shutdown features of
Windows
®
and Mac OS X
• IncludedPowerAlertUPSmonitoringsowaresupports
safe unattended shutdown, monitoring and control via local
connected servers, plus any number of additional servers
over IP
• UPSinterfacesupportson-battery,low-battery,
power-restored,AC-voltage,DC-voltage,outputcurrent
monitoring, battery charge current, battery capacity, timed
invertershuto,activateself-testandoutputpower
control
• NEMA5-15Pinputplug;8battery-supportedNEMA5-15R
output receptacles
• Datalinesurgesuppressionprotectsdialup,DSLor
network Ethernet connection
• FrontpanelLEDsoercurrentmonitoring,voltage
regulation and battery charge level information
• UPSshipsfullyassembledinfullcompliancewithDOT
regulations; no time-consuming connection of internal
batteries by user required
• 2-yearwarranty;
$
250,000UltimateLifetimeInsurance
(U.S.andCanadaonly)