SereneLife AZPHUMDIF3 Owner's manual

Category
Humidifiers
Type
Owner's manual

This manual is also suitable for

Method of Use
·Please put the machine 2 meters away from any electrical appliances (ie. computer,
TV, Speakers, etc). Picture 1
·Please put the machine on a stationary desk; if the appliance tilts, it may cause internal
damage. Picture 2
·Please do not place the machine near any curtains or drapes. Picture 3
·Please do not put the machine in high-heat areas. This includes an area with a lot of
sunlight, a furnace or other heat sources. Picture 4
Operation Steps
x In order to use the humidifier, please place the appliance on a stationary
flat-surface or table.
x Pull out the water tank and open the tank cover. Fill the water tank up to the
designated fill-line, place the cover back on, and then place the tank smoothly
on the base. The humidifier should be powered off while filling up the tank.
x The nozzle that is located on the top should be placed in the slot of the water
tank.
x Connect the power to an outlet in a safe location. Turn the power switch on
(do not attempt to power on the unit while the water tank is being filled), the
power indicator light is lit, humidifier started to spray.
x Adjust the intensity of the mist with the knob located on the front of the
humidifier. Turning this knob will adjust the amount of mist being emitted
from the humidifier; adjust this to your personal preference.
x After a few minutes of being on, it is normal for the mist to begin to build up
around the top of the unit.
Abnormal Situations - Troubleshooting
If your humidifier doesn’t work, please check before asking for service requirements.
Fault
Reason Analysis
Troubleshooting
Power display lamp
does not work
No power
Turn on the power,
rotating the
switch clockwise
Float is stuck
Clean a
nd gently toggle the float,
making it smooth
The spray mist has
an abnormal odor
New humidifier
Open the water tank, and place it in
the open shade for 12 hours
The water
is dirty or has
been stored for a long time
Clean and change with fresh water
Decreased intensity
of misting
The atomization piece
fouling
Clean the atomization piece
Water dirty or storage for a
long time
Clean and change with fresh water
The fog mouth isn’t
properly covered
Cover the top correctly
Power Supply Schematic
Fog Volumn adjusting deviceFog Volumn adjusting device
AC220V 50Hz
AC power supply switch 2.5 A
Power Panel
Oscillation circuit board
Atomization piece
DC12V fan power
Mist intensity
adjusting device
Water shortage
protection buoy
switch
Warning: Please do not disassemble the machine. Any maintenance work should
be sent to the service center for maintenance by professionals. If not, this could be
a safety hazard.
SereneLife
Model: PHUMDIF3
Ultrasonic Humidifier
Instruction Book
Notes
A) This machine’s suitable working environment is 40-110° Fahrenheit. Please
do not use the machine below 0° Fahrenheit.
B) The water used to fill the humidifier’s tank is suggested to be at room
temperature. Please do not use water that is over 100° Fahrenheit.
C) Hold the tank steadily while adding water to avoid the tank slipping; accidents
can occur while operating this machine.
D) Place the humidifier power cord into the socket safely, making sure that it is
fully plugged in and the contact is good. Make sure your hands are not wet
while operating the plug of this device; doing so can cause electric shock.
E) Do not place the humidifier within arm’s reach of children.
F) It is strictly prohibited to use this machine in an area where there is flammable
equipment and/or gas.
G) If the water tank spills while the unit is on, please make sure to immediately cut
off the power supply by unplugging the humidifier.
H) If the machine begins to emit an abnormal sound or smell, please immediately
unplug the appliance. If the humidifier needs maintenance, it must be repaired
by the manufacturer or the manufacturer’s designated maintenance department.
I) To avoid the area surrounding the humidifier from getting wet, do not move the
mist nozzle.
J) When the humidifier is turned on, do not touch the water in the tank or the
components that are placed in the water.
K) If the humidifier is turned on while there is no water inside the water tank, this
may degrade the appliance.
L) Before cleaning or performing maintenance on this appliance, make sure that it
is powered off.
M) Please do not let the water flow in the interior of the machine; this will cause
damage to its internal parts.
N) Please do not add any additives in the water that the manufacturing company
has not approved.
O) If the power cord is damaged or aged, you should immediately stop using this
product. If the humidifier needs maintenance, it must be repaired by
manufacturer or its maintenance department related person.
P) If the humidifier will not be used for an extended period of time, please turn the
product off and unplug the power from the socket.
Q) Do not perform product maintenance by yourself; if the humidifier breaks down
or needs maintenance, please contact the service-center designated by the
manufacturer.
Cleaning and Maintenance
A) Daily Cleaning and Maintenance
In certain geographic locations, the water will contains higher levels of calcium and
magnesium. Because of this, it is important to stay on top of the cleaning and the
maintenance of your humidifier.
When using your humidifier, there may be residue of calcium after the mist that is
sprayed out of the machine dries. If this residue builds up on the nozzle, atomization
piece, or the tank surface, it can affect the humidification function of your appliance.
Make sure that you clean this build-up regularly in order to get the most out of your
humidifier.
B) Keeping the Humidifier Clean
Always use clean and clear water while cleaning and/or operating the humidifier. If you
wish to fully clean the humidifier, you may clean the spray nozzle, the tank, and the
base of the humidifier. Always change the water as frequently as possible. Do not
leave water in the tank if the machine is not being used for a long period of time.
Wipe all of the parts dry before you put it back together after cleaning.
C) Cleaning the Atomizer and the Base
Pour cleaning agent into the inside frame, and then add water so that the cleaning agent
is completely dissolved. Soak for about two minutes, and then use a brush to gently
clean the surface of the atomization piece until the calcium/mineral residue is removed.
You can also clean the base at the same time by using the same method. After
cleaning these parts with cleaning agents, make sure to clean it one final time with
water.
Please keep the cleaning agent that you are using to clean your humidifier away from
children. Do not touch your mouth or eyes after handling cleaning agents. Make
sure you wash your hands thoroughly after using a cleaning agent. If contact with a
cleaning agent is made to your mouth or eyes, immediately rinse with water and contact
a poison control center.
Expanded View
Products Parameters
Voltage
110V
Frequency
50HZ
Power
28W
Mist Output
200~1000ml/h
Capacity
4L
Noise
GE
Nozzle
Water Tank
Main Body
Adjusting Knob
Base
Dear Customer!
Congratulations on the purchase of our progressively designed humidifier. We hope that you
will enjoy our products and choose them for years to come. In order to use this product
efficiently and safely, please read this manual and save it for future reference.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

SereneLife AZPHUMDIF3 Owner's manual

Category
Humidifiers
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI