Haier HEN70ETFP Installation and User Manual

Category
Dehumidifiers
Type
Installation and User Manual
TABLE OF CONTENTS
DEHUMIDIFIER SAFETY ............................................................................................................................................. 2
PARTS AND FEATURES .............................................................................................................................................. 3
INSTALLATION REQUIREMENTS ................................................................................................................................ 3
Location Requirements ...................................................................................................................................... 3
Electrical Requirements ...................................................................................................................................... 3
INSTALLATION INSTRUCTIONS ................................................................................................................................. 4
Step 1 - Unpack
Dehumidier .............................................................................................................................. 4
Step 2 - Install Direct Drain .................................................................................................................................. 4
Step 3 - Install Drain Tube to Drain Pump ............................................................................................................... 5
Step 4 - Complete Installation ............................................................................................................................. 5
CONTROL PANEL ...................................................................................................................................................... 6
Display ............................................................................................................................................................. 6
Buttons and Indicators ........................................................................................................................................ 6
DEHUMIDIFIER USE ................................................................................................................................................... 7
Defrost Mode .................................................................................................................................................... 7
DEHUMIDIFIER CARE ................................................................................................................................................ 7
Cleaning ........................................................................................................................................................... 7
Air Filters .......................................................................................................................................................... 7
Water Collection Bucket ..................................................................................................................................... 8
Storage ............................................................................................................................................................. 8
TROUBLESHOOTING ................................................................................................................................................ 8
LIMITED WARRANTY ................................................................................................................................................. 9
RECORD KEEPING ................................................................................................................................................... 10
1
ENGLISH
DEHUMIDIFIER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all
safety messages.
DANGER
WARNING
CAUTION
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will
follow the safety alert symbol and either the word “DANGER,” “WARNING” or “CAUTION.”
These words mean:
An imminently hazardous situation. You could be killed or seriously injured if you don’t
immediately follow instructions.
A potentially hazardous situation which, if not avoided, could result in death or serious
bodily injury.
A potentially hazardous situation which, if not avoided, may result in moderate or minor
injury.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what
can happen if the instructions are not followed.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of re, electrical shock, injury to persons, or damage when using the dehumidier, follow
basic precautions, including the following:
Read all instructions before using this dehumidier.
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Do not operate the
dehumidier if it has a damaged cord
or plug, if it is not working properly, or if it has been
damaged or dropped.
The dehumidier should be serviced only by qualied
service personnel. Call an authorized service company
for examination, repair, or adjustment.
Disconnect power before servicing.
Disconnect power before cleaning.
NOTE: Turning
o power by pressing the Power
button does NOT disconnect the appliance from the
power supply.
Do not install or use the dehumidier in any area where
the atmosphere contains combustible gases or where
the atmosphere is contaminated. Avoid any chemicals
coming in contact with your dehumidier.
Do not store anything directly on top of the dehumidier.
Use two or more people to move and install dehumidier.
Never operate the
dehumidier without the lters in
place.
Do not use the dehumidier near a bathtub, shower or
wash basin or other wet area.
Do not drink water collected in the water collection
bucket.
READ AND SAVE THESE INSTRUCTIONS
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
2
ENGLISH
PARTS AND FEATURES
a
f
g
c
d
b
e
i
h
A
Control Panel
B
Dehumidied Dry
Air Vent
C
Handle
D
Water Collection
Bucket
E
Casters
F
Humid Air Intake
G
Air Filter
H
Direct Drain
Outlet
I
Drain Pump
Connector
INSTALLATION REQUIREMENTS
LOCATION REQUIREMENTS
Place the dehumidier on a at, level, surface to avoid
shaking, vibration and water spilling.
The surface must be strong enough to support the
dehumidier when the collection bucket is full of water.
Maintain a minimum 8" (20 cm) clearance around the
dehumidier to dissipate the heat properly.
20"
(51 cm)
20"
(51 cm)
20"
(51 cm)
20" (51 cm)
Keep the dehumidier free of any obstructions such as
drapes, curtains, blinds, etc.
Keep all windows and doors to the outside closed when
operating the dehumidier. Humid air will increase the
dehumidier’s workload.
Do not place the dehumidier in an area where the
temperature will fall below 38°F (3°C). Lower
temperatures may cause a layer of frost to accumulate
which will decrease performance.
Do not place the dehumidier in direct sunlight or near a
heat source such as baseboard heaters, stoves, etc.
ELECTRICAL REQUIREMENTS
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove the ground prong from the power
cord plug.
Do not use an adapter.
Do not use an extension cord.
Failure to do so can result in death, fire or
electrical shock.
3
ENGLISH
POWER SUPPLY CORD
Wiring Requirements
115 Volt, 60Hz, 15-amp fused grounded 3 prong outlet
The use of a time-delay fuse or time-delay circuit breaker
is recommended.
Use a dedicated circuit only.
NOTE: Do not operate any other electrical
appliances on this circuit or you may trip the circuit
breaker/fuse.
REQUIRED GROUNDING METHOD
This dehumidier must be grounded. The dehumidier is
equipped with a power supply cord that has a 3 prong
grounding plug. The power supply cord must be plugged into
a mating, grounded 3 prong outlet, and grounded in
accordance with all local codes and ordinances.
115V
15 Amp
INSTALLATION INSTRUCTIONS
STEP 1 - UNPACK DEHUMIDIFIER
WARNING
Excessive Weight Hazard
Use two or more people to move and install
dehumidifier.
Failure to do so can result in back or other injury.
Remove packaging materials. Save the carton and the
foam packaging for storing the dehumidier when not in
use.
NOTE: There are no packing materials inside the
dehumidier to remove. Do Not open the cabinet.
Properly dispose of/recycle all packing material.
Handle the dehumidier gently.
Keep the dehumidier upright and level. Do not set the
dehumidier on its side, front, back or upside down.
STEP 2 - INSTALL DIRECT DRAIN
(Optional)
If you plan to operate your
dehumidier continuously, and
you are placing it near a oor drain, such as in a basement,
you may decide to install a direct drain to avoid having to
empty the water collection bucket.
1. Unscrew and remove the drain cover on the back of the
dehumidier.
2. Remove the soft, rubber stopper. Place the drain cover
and stopper into the water bucket for safe keeping.
b
a
A
Rubber
Stopper
B
Drain Cover
3. Connect a drain hose (not provided) to the garden-hose
style drain connection.
a
A
Drain Hose
4. Lower the drain hose horizontally into a drain.
4
ENGLISH
STEP 3 - INSTALL DRAIN TUBE TO
DRAIN PUMP
(Optional)
If you plan to operate your dehumidier continuously, and it
requires a longer hose to reach a
oor drain, or the drain is
located above the dehumidier, connect the 16 ft (4.9 m)
drain tube with drain tube tting (provided) to the drain pump
connector on the back of the dehumidier. When the level of
the water inside the collection bucket reaches the specied
level, the drain pump will automatically pump the water to
the drain.
1. Remove the drain tube from the water collection
bucket.
a
b
A
Drain Tube Fitting
B
Drain Tube (16 ft [4.9 mm] long)
2. Insert the drain tube tting into the drain pump
connector located on the back of the dehumidier.
A
Drain Tube Fitting
B
Drain Pump Connector
3. Push the drain tube tting as far as possible into the
drain pump connector.
NOTE: Make sure that the drain tube tting has
securely snapped into position.
a
A
Drain Tube Fitting
4. Insert the opposite end of the drain tube into the drain.
5. To remove the drain tube, turn the knob of the drain
pump connector clockwise 45° while pulling out the
drain tube tting.
NOTE: The drain tube tting will pop away from the
drain pump connector.
a
A
Drain Pump Connector Knob
STEP 4 - COMPLETE INSTALLATION
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove the ground prong from the power
cord plug.
Do not use an adapter.
Do not use an extension cord.
Failure to do so can result in death, fire or
electrical shock.
1. Place the dehumidier on a rm, level surface in a
suitable location. See “Location Requirements.”
2. Make sure the water collection bucket is inserted
correctly into the dehumidier.
NOTE: If the Bucket Full indicator illuminates,
remove the water bucket and check that the
oat
lever moves freely.
3. Plug the power cord into a grounded 3 prong outlet.
5
ENGLISH
CONTROL PANEL
a b c d e
fgh
BUCKET
FULL
DEFROST
HIGH
LOW
ON
OFF
CHECK
FILTER
% RH
POWER SPEED TIMER HUMIDITY / TIME FILTER RESET
DISPLAY
Displays the current room humidity as a percent, or the
hours remaining in a Time Delay. The corresponding indicator
light will illuminate.
BUTTONS AND INDICATORS
A
POWER BUTTON
Press the Power button to turn On/O the
dehumidier.
NOTE: Turning o power by pressing the Power
button does NOT disconnect the appliance from the
power supply.
B
FAN SPEED BUTTON
The fan speed can be adjusted from Low to High speed.
Press the Fan Speed button to toggle among the two
speeds. The corresponding fan speed indicator will
illuminate.
C
TIMER BUTTON
Auto Turn ON/Auto Turn OFF
Program a time from (1-hour to 24-hours) for the
dehumidier to turn O or On. When a Time Delay is
programmed, the Timer ON indicator light will
illuminate.
While the dehumidier is operating:
1. Press the Timer button.
2. Press the Up Arrow/Down Arrow buttons to select
the number of hours you want the dehumidier to
continue to operate before turning O.
NOTE: After displaying the time, the Display
will revert to showing the current humidity after
10 seconds have passed.
While the dehumidier is o:
1. Press the Timer button.
2. Press the Up Arrow/Down Arrow buttons to select
the number of hours you want the dehumidier to
remain o before turning On.
NOTE:
After displaying the time, the Display
will revert to showing the current humidity after
10 seconds have passed.
To cancel the timer:
Press the Timer button once, the hours remaining
will ash, press the timer button again and the timer
will be cancelled.
D
HUMIDITY/TIME (Up and Down Arrow) BUTTONS
Adjusts the Humidity or Hours in Time Delay.
To Set the Humidity Level:
The humidity can be set between 30% Relative Humidity
(RH) and 90% RH. The humidity can be adjusted in
increments of 5% by each press of a button.
Press the Up Arrow/Down Arrow buttons to select
the desired Relative Humidity (RH).
NOTE: After setting the humidity level, the
display will revert to the current humidity after
10 seconds have passed.
E
FILTER RESET BUTTON
Press this button to reset the air lter timer and to
turn O the Check Filter indicator.
F
FILTER STATUS
After 250 hours of operation, the lter indicator light will
illuminate to remind you to clean the air lter. Clean the
air lter. See “Cleaning.”
G
BUCKET FULL
When the water collection bucket is full the indicator
illuminates to remind you to empty the bucket.
H
DEFROST
When the room temperature is low, the dehumidier
enters defrost mode and the indicator illuminates.
6
ENGLISH
DEHUMIDIFIER USE
IMPORTANT: If the dehumidier has been tilted on its
side, wait 24 hours before turning on the dehumidier to
allow the oil to return to the compressor. This will
prevent the dehumidier from failing prematurely.
Allow 20" (51 cm) of space around the unit for proper air
circulation.
Do Not operate the dehumidier without an air lter in
place.
Do not spill liquid on the control panel; it may cause an
electrical short to the interior electronic parts that would
either disable them or cause them to function
improperly.
When the unit is operated in high humidity conditions,
you may need to empty the water bucket more
frequently.
When the water collection bucket is full, the dehumidier
will stop operating automatically. The Bucket Full
indicator illuminates to alert you of this condition. Empty
the water collection bucket. See “Cleaning.”
When the empty water collection bucket is replaced
properly, the dehumidier will restart and operate
normally.
DEFROST MODE
If the dehumidier is operated at temperatures below
54°F (12°C), but above 41°F (5°C), the surface of the
evaporator may accumulate a layer of frost which would
reduce the eciency of the dehumidier. So, the
dehumidier will enter periodic defrost mode. The time
to defrost may vary. If the dehumidier freezes up, turn it
o at the power supply and restart.
NOTE: If the room temperature remains below 41°F
(5°C), the dehumidier should be turned OFF.
DEHUMIDIFIER CARE
WARNING
Electrical Shock Hazard
Disconnect power before cleaning.
Failure to do so can result in death or electrical shock.
CLEANING
1. Unplug dehumidier or disconnect power.
2. Use only a soft cloth dampened with water to clean the
cabinet.
NOTE:
Do not use a liquid or spray cleaner to clean the
dehumidier.
Do not wash with a hose or immerse in water.
DO NOT use chemicals, abrasives, ammonia,
chlorine bleach, concentrated detergents,
solvents or scouring pads. Some of these
chemicals/items may damage and/or discolor
your
dehumidier.
3. Wipe dry with a soft cloth.
4. Plug in or reconnect power.
AIR FILTERS
Your dehumidier features a removable air lter located at
the back of the unit behind the humid air intake grille.
IMPORTANT:
DO NOT use your dehumidier without
the air lter in place.
1. Unplug or disconnect power.
2. Pull on the tabs to slide out the lters from the back of
the dehumidier.
NOTE: The secondary lters are accessible once
the main lters are removed.
b
a
A
Air Filter
B
Humid Air
Intake Grille
3. Wash or vacuum the dust from the air lters.
NOTE: If washed, gently shake the lter to remove
the excess water and dust particles trapped in the
lter.
4. Reinstall the lters.
5. Plug in or reconnect power.
7
ENGLISH
WATER COLLECTION BUCKET
WARNING
Sickness Hazard
Do not drink water collected in water bucket.
Doing so can result in sickness.
The Bucket Full indicator illuminates, when the water
collection bucket has lled with water.
To Empty the Water Collection Bucket:
1. Unplug the dehumidier or disconnect power.
2. Using two hands, slowly slide the water collection
bucket from the front of the dehumidier.
a
A
Water
Collection
Bucket
3. Empty the water collection bucket.
4. Replace the empty water collection bucket into the
dehumidier.
5. Plug in or reconnect power.
STORAGE
If the unit is not being used for a long period of time:
1. Unplug the
dehumidier or disconnect power.
2. Drain the water from the water bucket. See
“Dehumidier Care.”
3. Use the original packaging to repack the unit to avoid a
buildup of dust or dirt.
4. Store the
dehumidier in a cool, dry location.
TROUBLESHOOTING
First try the solutions suggested here to possibly avoid the cost of a service call.
PROBLEM POSSIBLE CAUSE SOLUTION
Unit does not start or
operate
Power supply cord is not plugged into an
outlet.
Plug dehumidier into a grounded 3 prong
outlet.
The Power button has not been pressed. Press the Power button on the Control Panel or
Remote Control to turn ON the dehumidier.
There is no power to the electrical outlet. Plug a working lamp into the outlet to check
for power.
A household fuse has blown or a circuit
breaker has tripped.
Replace the fuse or reset the circuit breaker.
The control was programmed for a Time Delay. Cancel the Time Delay. See “Control Panel.”
The batteries in the remote control are dead. Replace the batteries.
The water bucket is full.
NOTE: The dehumidier automatically
turns o, and the Bucket Full indicator
illuminates to alert you of this condition.
Empty the water bucket. See “Dehumidier
Care.”
8
ENGLISH
PROBLEM POSSIBLE CAUSE SOLUTION
Dehumidier is working
but the room is still
humid.
The room is humid.
NOTE: On extremely hot and humid days,
the dehumidier will take longer to
dehumidify the room.
Allow time for the room to dehumidify when
you rst turn on the unit.
Make sure the dehumidier has an adequate
BTU rating for the size of the room being
cooled.
Airow is restricted. Remove any obstacles to the airow and
redirect airow for uniform cooling.
RH Level set too high Lower the set humidity level.
Air lters are dirty or restricted. Clean the air lter. See “Dehumidier Care.“
Doors and windows are open. Close the doors and windows to the room
being cooled to prevent cooled air from
escaping.
FOR MORE HELP, VISIT HAIERAMERICA.COM OR CALL THE CONSUMER HELP LINE AT 1-877-337-3639.
LIMITED WARRANTY
IN-HOME SERVICE
FULL ONE YEAR WARRANTY
12 Months on Parts, Labor and Sealed System
For 12 months from the date of original retail purchase, Haier
will replace any part free of charge that fails due to a defect in
materials or workmanship.
Haier may replace at their sole discretion any part, sub
system including the entire product.
LIMITED WARRANTY
NOTE: This warranty commences on the date the item
was purchased, and the original purchase receipt must
be presented to the authorized service representative.
Exceptions: Commercial Use Warranty
90 days parts from date of original purchase
No other warranty applies.
FOR WARRANTY SERVICE
All parts must be provided by a Haier authorized service
center. For the name and telephone number of the nearest
authorized service center, please call 1-877-337-3639.
Before calling please have available the following
information:
Model number and serial number of your appliance. The
name and address of the dealer you purchased the unit from
and the date of purchase.
A clear description of the problem.
A proof of purchase (sales receipt).
This warranty covers home appliance services within the
contiguous United States and Canada and where available
in Alaska, Hawaii and Puerto Rico.
What is not covered by this warranty:
Replacement or repair of household fuses, circuit breakers,
wiring or plumbing.
A product whose original serial number has been removed or
altered.
Any service charges not specically identied as normal such
as normal service area or hours.
Damage incurred in shipping.
Damage caused by improper installation or maintenance.
Damage from misuse, abuse, accident, re, ood, or acts of
nature.
Damage from service other than an authorized Haier dealer
or service center.
Damage from incorrect electrical current, voltage or supply.
Damage resulting from any product modication, alteration
or adjustment not authorized by Haier.
Adjustment of consumer operated controls as identied in
the owner’s manual.
Labor, service transportation, and shipping charges for the
removal and replacement of defective parts beyond the
initial 12-month period.
Damage from other than normal household use.
Any transportation and shipping charges.
THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL
OTHER WARRANTIES, EXPRESSED OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE.
The remedy provided in this warranty is exclusive and is
granted in lieu of all other remedies.
9
ENGLISH
This warranty does not cover incidental or consequential
damages, so the above limitations may not apply to you.
Some states do not allow limitations on how long an implied
warranty lasts, so the above limitations may not apply to you.
This warranty gives you specic legal rights, and you may
have other rights, which vary from state to state.
Haier America
Wayne, NJ 07470
RECORD KEEPING
Thank you for purchasing this Haier product. This user manual will
help you get the best performance from your new dehumidier.
For future reference, record the model and serial number located
on the label on the side of your dehumidier, and the date of
purchase.
Staple your proof of purchase to this manual to aid in obtaining
warranty service if needed.
_______________________________________
Model number
_______________________________________
Serial number
_______________________________________
Date of purchase
10
ENGLISH
IMPORTANT
Do Not Return This Product To The Store
If you have a problem with this product, please contact the
“Haier Customer Satisfaction Center” at
1-877-337-3639.
DATED PROOF OF PURCHASE, MODEL #, AND SERIAL #
REQUIRED FOR WARRANTY SERVICE
IMPORTANT
Ne pas Réexpédier ce Produit au Magasin
Pour tout problème concernant ce produit, veuillez contacter
le service des consommateurs “Haier Customer Satisfaction Center” au
1-877-337-3639.
UNE PREUVE D’ACHAT DATEE EST REQUISE POUR BENEFICIER DE LA GARANTIE.
IMPORTANTE
No regrese este producto a la tienda
Si tiene algún problema con este producto, por favor contacte el
“Centro de Servicio al Consumidor de Haier” al
1-877-337-3639 (Válido solo en E.U.A).
NECESITA UNA PRUEBA DE COMPRA FECHADA, NÚMERO DE MODELO
Y DE SERIE PARA EL SERVICIO DE LA GARANTÍA
Made in China
Fabriqué en Chine
Hecho en China
Haier America
Wayne, NJ 07470
Printed in China
HEN70ETFP
Issued: December2016 Part # 0060522959 REV A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Haier HEN70ETFP Installation and User Manual

Category
Dehumidifiers
Type
Installation and User Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages