3 Commissioning
3.1 Before Commissioning
VACON
®
OPTE3/E5 PROFIBUS DP can be commissioned through the control panel of the AC drive or by using the VACON
®
PC tools.
Before starting the commissioning, check the following:
When using the control panel of the AC drive for commissioning: for instructions on how to use the control panel, see the Oper-
ating Guide for VACON
®
NXP products or the Application Guide for the VACON
®
100 family.
When using VACON
®
PC tool for commissioning: the correct tool installed.
For a list of supported PC tools, see 1.5.5 VACON® PC Tools.
For instructions on installing the tools, see 3.1.1 Installing VACON® PC Tools.
VACON
®
AC drive in which OPTE3/E5 PROFIBUS DP option board installed. See VACON
®
RS485 CAN bus Installation Guide for
instructions.
When using serial connection:
VACON
®
NXP is connected to PC with RS232 serial cable. The cable is connected from PC to the 9-pin D-SUB connector
(female) of the VACON
®
NXP control unit. If PC does not contain RS232 serial port, then USB - RS232 converter device is
needed between PC and VACON
®
NXP control unit.
VACON
®
100 family and VACON
®
20 are connected to PC with VACON
®
Serial Cable.
When using Ethernet connection:
Ethernet cable which is connected to the Ethernet interface of the option board, or, in VACON
®
100 family drives, of the
control board.
VACON
®
NXP requires option board supporting Ethernet communication. For example, OPTEA/OPTE9 Dual Port Ethernet
option board.
3.1.1 Installing VACON® PC Tools
Prepare for commissioning by installing the needed VACON
®
PC Tools.
Procedure
Go to www.danfoss.com/.
Select Downloads from Service and Support drop-down menu.
Select Drives as business unit.
Download the VACON
®
PC tool depending on the used AC drive.
VACON
®
100 family AC drive: VACON
®
Loader and VACON
®
Live
VACON
®
20 AC drive: VACON
®
Loader and VACON
®
Live
VACON
®
NXP AC drive: VACON
®
NCDrive and VACON
®
Loader
Start the installation program and follow the on-screen instructions.
After installation, launch VACON
®
PC tool from Windows Start menu.
For more information about software features, go to Help drop-down menu and select Contents.
3.1.2 Downloading Fieldbus Option Firmware
Prepare for commissioning by downloading the Fieldbus Option Firmware.
Procedure
Go to
www.danfoss.com/.
Select Downloads from Service and Support drop-down menu.
Select Drives as business unit.
Download le Fieldbus rmware.
BC346130363093EN-US-000101 / DPD0099718 | Danfoss A/S © | 2020.06
Commissioning
VACON® OPTE3/E5 PROFIBUS DP
User Guide