DNCP Series 400/400-CO (PA-8500)
Hardware Installation Guide (FTX systems)
Revision 0.0
5/5/00
Copyright© 2000 Lucent Technologies. All Rights Reserved.
This material is protected by the copyright laws of the United States and other countries. It may not be
reproduced, distributed, or altered in any fashion by any entity (either internal or external to Lucent
Technologies), except in accordance with applicable agreements, contracts or licensing, without the express
written consent of Lucent Technologies, Inc.
Notice
Every effort was made to ensure that the information in this document was complete and accurate at the time of
printing. However, information is subject to change.
Interference Information: Part 15 of FCC Rules
The equipment document in this manual generates and uses radio frequency energy, which, if not installed and
used in strict accordance with the instructions in this manual, may cause harmful interference to radio
communications. The equipment has been tested and found to comply with the limits for a Class A computing
device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection
against such interference when operated in a commercial environment.
Operation of this equipment in a residential area is likely to cause interference, in which case the user at his
own expense will be required to take whatever measures may be required to correct the interference.
Trademarks
DNCP is a trademark of Lucent Technologies Inc.
Continuum is a trademark of Stratus Computer, Inc.
RSN is a trademark of Stratus Computer, Inc.
Hewlett-Packard and HP are registered trademarks of Hewlett-Packard.
PA/RISC is a trademark of Hewlett-Packard.
Other trademarks and trade names mentioned in this publication belong to their respective owners.
For more Lucent trademark information, contact (908) 903-6384
Technical Service Guide
Manual Conventions
For standardization purposes, the following conventions will be used throughout this manual
Bolded Text is used for information which needs to be emphasized
Italicized text is used for information which needs to be identified, such as component names
or a specific system status
The following conventions relate primarily to the software sections:
Courier new bold text is used to indicate commands the user is to type.
Courier new text is used to indicate screens commands/printouts that the user would
see,
or to indicate, in an explanation paragraph, the type of command a user is to use to
execute
this function.
<keyboard key> or <onscreen key> is used to indicate either a keyboard or
onscreen key the user needs to recognize or press.
Boxed text in courier new font
(in Chapters 5 and 6) show information which is being referred to
(this can include report printouts or other data--sales picklists...)
Manual Conventions
1. Preparing to Install the System
Safety Considerations
Required Tools
System Description-- for DNCP Series 400 (PA-8500) Cabinet
System Description-- for DNCP Series 400-CO (PA-8500) Cabinet
Status Lights
System Peripherals
2. Installing the Core System Components
Installing the Cabinet -- for DNCP Series 400 (PA-8500)
Installing the Cabinet -- for DNCP Series 400-CO (PA-8500)
Installing the System Console
Installing a C419/C619 Modem for RSN Use
Installing PCI Cards and Cables
3. Installing the Tape Drives
Installing a Stand-Alone T800-Series Tape Drives
Installing Daisy-Chained T800-Series Tape Drives
Completing the Installation of Tape Drives on a Running System
4. Booting the System
5. Configuring the RSN and C416/C619 Modem
Preparing to Configure the RSN
Configuring the RSN
Configuring the C419/C619 Modem
Completing and Verifying Configuration of the RSN
6. Sending the Installation Report
Preparing an Installation Report
Sending an Installation Report to CAC
Sample Installation Report
Appendix A. Fault Isolation
General LED Information
System Component LEDs
Power Supply LEDs
Disk Shelf LEDs
Suitcase LEDs
PCI Card LEDs
System Log and Status Messages
Component Status
Software State Information
Hardware Status Information
Fault Codes
Troubleshooting Procedures
Installation Guide
]
Chapter 1
Preparing to Install the System
This chapter contains important information to read before proceeding with the installation, such as a system description
and vital safety considerations. This chapter is divided into the following sections.
Safety Considerations
Required Tools
System Description
1.1 Safety Considerations
Before installing the system, be sure to take the following important precautions.
To ensure a safe and effective installation, follow the procedures exactly as they are
written in this manual
Do not attempt to install the system without the assistance of another able-bodied person. The size and weight of
the system do not allow it to be safely installed by one person.
The information in this manual assumes that the system site has been prepared, and the system unpacked,
according to the instructions in the DNCP Series 400/400-CO (PA-8500): Site Planning Guide (R454) and the
DNCP Series 400/400-CO: Unpacking Instructions. Refer to these manuals before proceeding with the installation.
Observe all applicable industry safety standards.
Provide the necessary space and light to safely perform the installation.
Do not wear conducting objects, such as rings, bracelets, and keys.
Before installing the system, familiarize yourself with the system hardware and how to get help during the
installation by reading the remainder of this chapter.
1.2 Required Tools
To install the system, the following tools are necessary.
Flat-blade screwdriver
Phillips-head screwdriver
Torque wrench
Torx head wrench tool set
Digital voltmeter
1.3a System Description -- for DNCP Series 400 (PA-8500)
The DNCP Series 400 (PA-8500) system combines the Hewlett-Packard PA-RISC PA-8500 microprocessor with Lucent's
continuously available hardware. This system uses AC power . The DNCP Series 400 (PA-8500) system utilizes the FTX
operating system.
The DNCP Series 400 (PA-8500) achieves continuous availability by partnering, or duplexing, two identical online
components, so that if one fails, its partner continues to operate. Other system components ensure availability by operating
Chapter 1
]
in standby mode , with one component online, while the other "stands by" to take over operation should its partner fail.
The DNCP Series 400 (PA-8500) must be installed by a qualified service technician, but most of the components are
customer-maintainable
. Its data communications subsystem, based on a Peripheral Component Interconnect (PCI) bus,
utilizes state-of-the-art PCI cards. Peripherals include T800-series cartridge tape and D85X CD-ROM drives, V105
terminals, and C419/C619 modems, which are described later in this chapter. See Figure 1.1 for an illustration of the
DNCP Series 400 (PA-8500) system installed in a typical computer-room environment. The sections that follow describe
DNCP Series 400 (PA-8500) components.
Figure 1.1. DNCP Series 400 (PA-8500) System in a typical computer-room environment
1.3a.1 DNCP Series 400 (PA-8500) Cabinet
Each DNCP Series 400 (PA-8500) consists of a single cabinet that houses all major system components. Two sets of doors
on the front and rear of the cabinet provide access to these components. The following sections describe the cabinet
components.
Cabinet: Front Components
Rear Components
Chapter 1
]
System Ventilation
1.3a.1.1 DNCP Series 400 (PA-8500) Cabinet: Front Components
For the components housed in the front of the cabinet, See Figure 1.2 which is also described in the following
paragraphs.
Figure 1.2. DNCP Series 400 (PA-8500) Cabinet: Front View
The amber cabinet fault light, located at the top of the cabinet frame, above the doors, illuminates when one or more
components within the cabinet have failed. (For a more detailed explanation of system status lights, refer to the Appendix.
The power trays are located just below the cabinet fault light:
Power Tray 2 (on the top) includes two power supply units to power the PCI card cage bays. At the base of Power
Tray 2 are two Alarm Control Units (ACUs). The ACUs control the speed of the cabinet fans, monitor the status of
components within the cabinet, and control the component status lights. One ACU is online, while the other is in
standby mode.
Power Tray 1 (below Power Tray 2) includes two rectifiers to convert AC power to the necessary DC voltage for
the entire system.
Below the power trays are two disk shelves. Each disk shelf has nine slots, the two leftmost slots are reserved for two disk
power supply units, the other slots house up to seven 9GB or 18GB Small Computer System Interface (SCSI) disk drives.
Chapter 1
Maximum duplexed storage capacity is 126 GB per disk shelf, 252 GB per DNCP Series 400 (PA-8500) cabinet (63GB
per disk shelf, 126GB per system logical storage).
Located at the bottom of the cabinet are duplexed logic suitcases. These suitcases house the system's central logic
functions: the Hewlett-Packard CPUs, memory modules, and console controller, which is the system's central collection
point for maintenance, diagnostic information and user interface.
If the logic suitcases have a vinyl protective covering on the front, remove the covering once the system cabinet is in place.
Optional air filters are located below the suitcases, on the front of the disk shelves, and on the front of the two power
trays. System air filters must be changed regularly. (Refer to FTX Operating System: DNCP Series 400/400-CO
(PA-8500) Operation and Maintenance Guide (RXXX) for preventive maintenance instructions.)
1.3a.1.2 DNCP Series 400 (PA-8500) Cabinet: Rear Components
The rear of the cabinet has two doors that provide access to the components housed in the back of the cabinet. For an
illustration, See Figure 1.3 which is also described in the following paragraphs.
Figure 1.3. DNCP Series 400 (PA-8500) Cabinet: Rear View
The top of the cabinet has a cable opening that provides access for routing system power cables and communications
cables.
The top of the cabinet frame has an amber cabinet fault light that illuminates when a component within the cabinet has
failed. (For a more detailed explanation of system status lights, refer to the Appendix.
The top region also contains the power input connectors/backplane. The power assembly contains the duplexed AC power
Chapter 1
cables, and the alarm relay connector for remote alarm monitoring. Each power cable requires a separate AC electrical
source.
Below the power input region (AC power chassis) are two disk shelves which each contain three cooling fans, a SES
(SCSI Enclosure Services) unit, a SE-SE (single-ended to single-ended) I/O repeater module and a terminator module.
Below the disk shelves are two PCI card cages. Each card cage contains seven slots for PCI cards, for a total of 14 PCI
cards per system. Each PCI card cage has one bridge card that provides the interface between the logic suitcases and the
PCI cards. Each bridge card has a connector for a PC Memory Card International Association (PCMCIA) flash card, a
credit-card-sized EEPROM used to boot the operating system.
Beside each of the PCI card cages is a jack for attaching a grounding strap.
Four serial ports at the bottom of the cabinet are used to connect the system to the:
CPU/memory motherboard within each logic suitcase
system console
remote console
Remote Service Network (RSN) modem (Not all systems are connected to the RSN. For an explanation of the
RSN, refer to FTX System Administrator's Guide: General Services (R455X)
The bottom of the cabinet also has a cable opening for routing power and communications cables.
1.3a.1.3 System Ventilation
Ensure adequate air flow around the system during installation. The system requires two feet of clearance on the front and
rear of the cabinet, and a minimum of 18 inches of unobstructed area above the top of the cabinet. For cabinet ventilation
patterns and the required clearances to ensure proper cooling of internal components, See Figure 1.4.
Always ensure adequate air flow around the cabinet. Do not place objects on top of the
cabinet, or where they obstruct air vents. Obstructed air vents can cause the system to
overheat and parts within it to fail.
Figure 1.4. System Ventilation
Chapter 1
1.3b System Description for DNCP Series 400-CO (PA-8500)
DNCP Series 400-CO (PA-8500) system combines the Hewlett-Packard PA-RISC PA-8500 microprocessor, system
features rapid symmetric multiprocessing and continuously available hardware. Designed specifically for the CO
environment, the system is fully CO-compliant, including support of Zone 4 seismic resilience standards. This system uses
DC power. The DNCP Series 400-CO (PA-8500) system utilizes the FTX operating system.
The DNCP Series 400-CO (PA-8500) achieves continuous availability by partnering, or duplexing, two identical online
components, so that if one fails, its partner continues to operate. Other system components ensure availability by operating
in standby mode , with one component online, while the other "stands by" to take over operation should its partner fail.
The DNCP Series 400-CO (PA-8500) must be installed by a qualified service technician, but most of the components are
customer-maintainable. Its data communications subsystem, based on a Peripheral Component Interconnect (PCI) bus,
utilizes state-of-the-art PCI cards. Peripherals include T800-series cartridge tape drives, D85X CD-ROM drives, V105
terminals, and C419/C619 modems, which are described later in this chapter. See Figure 1.5 for an illustration of the
DNCP Series 400-CO (PA-8500) system installed in a typical computer-room environment. The sections that follow
describe DNCP Series 400-CO (PA-8500) components.
Figure 1.5. DNCP Series 400-CO (PA-8500) System in a computer-room environment
Chapter 1
1.3b.1 System Description -- for DNCP Series 400-CO (PA-8500) Cabinet
Each DNCP Series 400-CO (PA-8500) consists of a single cabinet that houses all major system components. Two sets of
doors on the front and rear of the cabinet provide access to these components. The following sections describe the cabinet
components.
Cabinet: Front and Rear Components
System Ventilation
1.3b.1.1 DNCP Series 400-CO (PA-8500) Cabinet: Front Components
For the components housed in the front of the cabinet, See Figure 1.6, which is also described in the following
paragraphs.
Figure 1.6. DNCP Series 400-CO (PA-8500) Cabinet: Front View
Chapter 1
The amber cabinet fault light , located at the top of the cabinet frame, above the doors, illuminates when one or more
components within the cabinet have failed. (For a more detailed explanation of system status lights, refer to the Appendix.
Four duplex power supplies are located just below the cabinet fault light: the top two power the ACUs, and the bottom two
power the PCI card cage bays. To the right of the power supplies are two Alarm Control Units (ACUs). The ACUs control
the speed of the cabinet fans, monitor the status of components within the cabinet, and control the component status lights.
One ACU is online, while the other is in standby mode.
Below the power trays are two disk shelves. Each disk shelf has nine slots, the two leftmost slots are reserved for two disk
power supply units, the other slots house up to seven 9GB or 18GB Small Computer System Interface (SCSI) disk drives.
Maximum duplexed storage capacity is 126 GB per disk shelf, 252 GB per DNCP Series 400-CO (PA-8500) cabinet
(63GB per disk shelf, 126GB per system logical storage).
Located at the bottom of the cabinet are duplexed logic suitcases. These suitcases house the system's central logic
functions: the Hewlett-Packard CPUs, memory modules, and console controller, which is the system's central collection
point for maintenance and diagnostic information.
If the logic suitcases have a vinyl protective covering on the front, remove the covering once the system cabinet is in place.
Optional air filters are located below the suitcases, on the front of the disk shelves, and on the front of the DC power
supply chassis. System air filters must be changed regularly. (Refer to FTX Operating System: DNCP Series 400/400-CO
(PA-8500) Operation and Maintenance Guide (RXXX) for preventive maintenance instructions.)
1.3b.1.2 DNCP Series 400-CO (PA-8500) Cabinet: Rear Components
The rear of the cabinet has two doors that provide access to the components housed in the back of the cabinet. For an
illustration, See Figure 1.7, which is also described in the following paragraphs.
Chapter 1
Figure 1.7. DNCP Series 400-CO (PA-8500) Cabinet: Rear View
The top of the cabinet has a cable opening that provides access for routing system power cables and communications
cables.
The top of the cabinet frame has an amber cabinet fault light that illuminates when a component within the cabinet has
failed. (For a more detailed explanation of system status lights, refer to the Appendix
The top region also contains the power input connectors for the duplexed DC power cables, and the alarm relay connector
for remote alarm monitoring. Each power cable requires a separate -48V nominal DC electrical source.
Below the power input region (DC power chassis) are two disk shelves which each contain three cooling fans, a SES (SCSI
Enclosure Services) unit, a SE-SE (single-ended to single-ended) I/O repeater module and a terminator module.
Below the disk shelves are two PCI card cages. Each card cage contains seven slots for PCI cards, for a total of 14 PCI
cards per system. See the PCI-card installation manual for detailed information about a specific PCI card. Each PCI card
cage has one bridge card that provides the interface between the logic suitcases and the PCI cards. Each bridge card has a
connector for a PC Memory Card International Association (PCMCIA) flash card, a credit-card-sized EEPROM used to
boot the operating system.
Beside each of the PCI card cages is a jack for attaching a grounding strap.
Four serial ports at the bottom of the cabinet are used to connect the system to the:
CPU/memory motherboard within each logic suitcase
system console
remote console
Remote Service Network (RSN) modem (Not all systems are connected to the RSN. For an
Chapter 1
]
explanation of the RSN, refer to FTX System Administrator's Guide: General Services (R455X)
The bottom of the cabinet also has a cable opening for routing power and communications cables.
1.3b.1.3 System Ventilation
Ensure adequate air flow around the system during installation. The system requires two feet of clearance on the front and
rear of the cabinet, and a minimum of 18 inches of unobstructed area above the top of the cabinet. For cabinet ventilation
patterns and the required clearances to ensure proper cooling of internal components, See Figure 1.8.
Always ensure adequate air flow around the cabinet. Do not place objects on top of the cabinet, or where they obstruct air
vents. Obstructed air vents can cause the system to overheat and parts within it to fail.
Figure 1.8. System Ventilation
1.4 Status Lights
Status lights on individual components enable customers to narrow down a problem to a single failed component. If a
problem occurs during the system installation, strategically-placed status lights provide assistance in diagnosing the
problem.
For more detailed information on system status lights (LEDs):
Check the labels on the cabinet. They explain the meaning of the cabinet, power supply, PCI and disk LEDs.
Refer to the Appendix in this manual
If a red, amber, or yellow light is illuminated and remains lit during the installation process, try reseating the
component and its partner. If the component still does not come online, refer to Operating System: DNCP Series
400/400-CO (PA-8500) Operation and Maintenance Guide (RXXX) for further status-light information and
Chapter 1
component troubleshooting procedures.
1.5 System Peripherals
The DNCP Series 400/400-CO (PA-8500) can include the peripherals described in the following sections.
V105 Terminal
C419/C619 Modem
Tape and CD-ROM Drives
V105 Terminal
The V105 terminal, which is shipped with most DNCP Series 400/400-CO (PA-8500) systems, is an ASCII
character-mode terminal that can be configured to operate as a system console to display system error and status
information. The V105 can also be used as a standard user terminal for communicating with system applications. It is
available with either an ANSI or PC keyboard. The V105 connects to either the Console (J315) or Auxiliary Console
(J316) serial port on the rear of the cabinet. For an illustration of the V105 terminal, (See Figure 1.10)
Figure 1.10. V105 Terminal
DNCP Series 400/400-CO (PA-8500) systems can also support other terminals as long as they are properly defined within
the system.
C419/C619 Modem
DNCP Series 400/400-CO (PA-8500) systems are connected to the Lucent Customer Assistance Center (CAC) through a
C419/C619 modem and a dedicated telephone line. The C419/C619 modem is preconfigured for RSN operation and can
transmit data at 33,600 bps. For an explanation of the RSN, refer to FTX System Administrator's Guide: General Services
(R455X). For an illustration of the C419/C619 modem, See Figure 1.11.
Figure 1.11 C419/C619 Modem
Chapter 1
]
To troubleshoot and replace a failed C419/C619, see FTX Operating System: DNCP Series 400/400-CO (PA-8500)
Operation and Maintenance Guide (RXXX). For other information on the C419/C619 modem, see the vendor manual
shipped with the modem.
Tape and CD-ROM Drives
DNCP Series 400/400-CO (PA-8500) systems support the T800-series tape and the D85X CD-ROM drives. For
information about tape drive operation and maintenance, refer to DNCP Series 400/400-CO (PA-8500): Tape Drive
Operation Guide (R716). For information about CD-ROM drive operation and maintenance, refer to DNCP Series
400/400-CO (PA-8500): CD-ROM Drive Installation and Operation Guide (R720).
Chapter 1
]
Chapter 2
Installing the Core System Components
After unpacking the system, follow the instructions in this chapter to install the core system components. The core system
components consist of the cabinet, V105 terminal, C419/C619 modem, and PCI cards. This chapter contains the following
sections.
Installing the Cabinet
Installing the System Console
Installing a C419/C619 Modem for RSN Use
Installing PCI Cards and Cables
The information in this chapter assumes that the system site has been prepared according to the instructions
in the DNCP Series 400/400-CO: Site Planning Guide (R454) and unpacked according to the instructions
in the DNCP Series 400/400-CO (PA-8500): Unpacking Instructions.
2.1a Installing the Cabinet -- for DNCP Series 400 (PA-8500)
Install the cabinet by performing the steps in the following sections:
If routing the power cables from the top of the cabinet, perform the following steps
(See Section 2.1a.1 Installing the Power Cables (Top Entry).
If routing the power cables from the bottom of the cabinet, perform the following steps (See Section 2.1a.2
Installing the Power Cables (Bottom Entry).
2.1a.1 Installing the Power Cables (Top Entry)
Perform the following steps to route the power cables from the top of the system.
Open the cabinet doors.1.
Verify that the cabinet ground wires are connected from the cabinet frame to the doors.2.
Make sure that the two MAIN power switches/AC Input breakers on the front of the cabinet are in the off (0)
position. (See Figure 2.1)
3.
Figure 2.1. Cabinet Grounding Wires and MAIN Power Switches/AC Breaker
Chapter 2
]
Using a flat-blade screwdriver, remove the cable opening cover from the top of the cabinet (See Figure 2.2).4.
Figure 2.2. Removing the Cable Opening Cover
Chapter 2
Using the torque wrench, attach the ground cable that is shipped with the system to the back of the system cabinet
(See Figure 2.3) , being careful not to apply more than 33 inch pounds of torque.
5.
The ground cable may be attached to the double ground lugs found on either the left or right
side of the cabinet.
Figure 2.3. Attaching the Ground Cable (Top of cabinet)
Chapter 2
Unpack the two system power cables from one of the cartons shipped with the system. The part number for each
power cable appears on the cable and on the plastic bag in which the cable is shipped.
6.
Before connecting a power cable, always shut off both MAIN system power switches/AC input
breakers on the same side of the cabinet.
Connect each power cable to the cabinet and into a separate AC power source. To connect to the cabinet, plug the
AC power cable into the AC power cable assembly top right (See Figure 2.4) .
7.
When routing the power cables through the cable opening at the top of the
cabinet, be careful not to disconnect the CABINET FAULT light cable.
Be sure to connect each power cable to a separate AC power source . If they
are plugged into the same source, a failure at the source will result in a system
crash.
Using a digital voltmeter (DVM), measure the AC input voltage. Verify that the voltage is within the range of 200
to 264 AC.
8.
If the input voltage is not within the specified range, do not proceed to the
next step. Verify the AC input power source.
Figure 2.4. Connecting the Power Cables (Top Entry)
Chapter 2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88

Lucent Technologies PA-8500 User manual

Category
Chassis components
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI