ClimateMaster ATA21S01 and ATA21S02 Install Manual

Category
Thermostats
Type
Install Manual

ClimateMaster ATA21S01 and ATA21S02 are advanced heat pump thermostats designed to provide efficient and convenient temperature control in residential and light commercial applications. These thermostats offer a wide range of features to enhance comfort, reduce energy consumption, and simplify operation. With their user-friendly interface and comprehensive functionality, the ClimateMaster ATA21S01 and ATA21S02 thermostats empower users to create a customized and energy-efficient indoor environment.

ClimateMaster ATA21S01 and ATA21S02 are advanced heat pump thermostats designed to provide efficient and convenient temperature control in residential and light commercial applications. These thermostats offer a wide range of features to enhance comfort, reduce energy consumption, and simplify operation. With their user-friendly interface and comprehensive functionality, the ClimateMaster ATA21S01 and ATA21S02 thermostats empower users to create a customized and energy-efficient indoor environment.

" READ THESE INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE OR SERVICE
THIS THERMOSTAT.
" Failure to observe safety information and comply with
instructions could result in PERSONAL INJURY, DEATH
AND/OR PROPERTY DAMAGE.
" To avoid electrical shock or damage to equipment,
disconnect power before installing or servicing.
" To avoid potential fire and/ or explosion do not use in
potentially flammable or explosive atmospheres.
" Retain these instructions for future reference. This
product, when installed, will be part of an engineered
system whose specifications and performance
characteristics are not designed or controlled by
ClimateMaster. You must review your application and
national and local codes to assure that your installation
will be functional and safe.
WARNING
CAUTION
! Use copper wire only, insulate or wire nut all un-used leads.
! Care should be used to avoid electrostatic discharge to the
microprocessor.
! This unit has configuration jumpers. You may need to re-
configure this thermostat for your application. See page 2.
© COPYRIGHT 2001 CLIMATEMASTER. ALL RIGHTS RESERVED P/N 67847 3220- Rev 0 Page 1
MODE BUTTON OPERATION SETBACK OPERATION
OFF All thermostat outputs are off, fan is still operational Unit operates in setback mode when the circuit is closed between
if ON, HI or LO is selected. terminal #7 and 24 VAC1. When operating in setback mode the
AUTO The thermostat automatically selects heating or control points are 50°F or 60°F for heating and 90°F or 85°F for
cooling mode depending upon the relationship of the cooling dependent on dip switch configuration. Fan operation in
set point and room temperature. The appropriate setback is cycled with demand. See dip switch configuration diagram.
HEAT or COOL indicator is enabled in addition to Pressing the mode, up or down buttons will override setback for 1
AUTO if demand exists. A 3°F dead-band is provided hour.
to prevent short cycling between heating and cooling REMOTE PROBE OPERATION
modes. After change-over the con tro l point An optional remote temperature probe can be used. Remove jumper
automatically shifts so that the control off point equals JP1 from the circuit board for proper operation.
the set point temperature. REVERSING VALVE OUTPUTS
COOL The thermostat operates as a cooling only thermostat. After a call for heat, the Reversing Valve Heat Output is continuously
HEAT The thermost at oper ates as a heat ing only active until there is a demand for cool. After a call for cooling, the
thermostat. Reversing Valve Cool Output is continuously active until there is a
If constructed without a mode button, the thermostat operates heat demand.
in AUTO mode. COMPRESSOR OUTPUT
FAN/ SYSTEM SWITCH OPERATION Compressor Output is active anytime there is a demand.
Fan speed is determined by manual selection from system STAGED HEAT OUTPUT
switch ON, HI, LO and/ or AUTO. In ON, HI or LO the fan output Staged Heat Output is active 3°F below first stage heat ON.
is continuous. In AUTO the output cycles with demand. In
AUTO and with the MODE in OFF all outputs are off. POWER-UP: Outputs may take up to two minutes to respond to
changes or on initial power-up.
INSTALLATION INSTRUCTIONS
1. Install the TH158 with the two furnished mounting screws to a
standard 4-11/16" x 2-1/8" square device box with a 2" x 4"
adapter ring.
2. For wall installations, mount the thermostat on an inside wall
approximately 5 feet above the floor. The location should
provide circulation at average room temperature. Avoid direct
sunlight or sources of hot or cold air in the room or wall.
3. Remove the cover. Mount thermostat base assembly to the
outlet box using the screws provided, tighten the screws evenly
but do not over tighten. Connect wires as shown in the
appropriate wiring diagram for your thermostat style.
4. To use a remote sensor on units with local sensing capability,
remove jumper JP-1 to disable local sensing. Failure to remove
JP-1 will cause improper operation of the thermostat.
5. Connection of a 24 VAC setback signal will force the control
into un-occupied mode (see diagram). Pressing an arrow key or
the mode buttons on the thermostat cover will disable the
setback input for one hour.
6. Reinstall the cover assembly. Install cover locking screw
provided. Remove the LCD plastic protective film to complete
the installation.
7. Checkout: After wiring and installation are complete, energize
the system and check the operation. Adjust the thermostat as
necessary to complete at least one cycle. Be sure the
thermostat and all other equipment are functioning correctly.
ATA21S01 and ATA21S02
TH158 MICROPROCESSOR
HEAT PUMP THERMOSTAT
AUTOAUTO
MODE
THERMOSTAT OPERATION
FAN
4.5
2.8
1.1
1.0
AUTOAUTO
MODE
FAN
HI LO AUTO
ON AUTO
ATA21S01 ATA21S02
THERMOSTAT OUTPUT OPERATION
O Cycles on with cooling demand. Output is held on until the
thermostat calls for heating.
B Cycles on with heating demand. Output is held on until the
thermostat calls for cooling.
Y1 Cycles on with heating or cooling demand
W1 Cycles on 3°F below first call for heat
NOTES:
1. Some models do not include wire leads. Refer to terminal
designations.
2. Specific model configuration may vary the number of
connections available.
© COPYRIGHT 2001 CLIMATEMASTER. ALL RIGHTS RESERVED P/N 67847 3220- Rev 0 Page 2
FAN OPERATION
Models with ON-AUTO Switch Selection:
G1 If AUTO position is selected then G1 cycles with demand.
If LO position is selected then G1 is fan continuous.
Models with HI-LO-AUTO Switch Selection:
G1 If AUTO position is selected then G1 cycles with demand.
If LO position is selected then G1 is fan continuous.
G2 If HI position is selected then G2 is on continuous.
NOTE:
1. When thermostat is operating in setback, fan operation is
cycled.
1 2 3 4 5 6
ON
FAHRENHEIT DISPLAY
N/A
HEAT PUMP OPERATION
HEAT PUMP OPERATION
HEAT PUMP OPERATION
HEAT PUMP OPERATION
50°F/ 90°F SETBACK
60°F/ 85°F SETBACK
NO OTHER CONFIGURATION OPTIONS
ARE AVAILABLE FOR THE DIP SWITCH
DIP SWITCH CONFIGURATION
CELSIUS DISPLAY
N/A
N/A
N/A
NOTE: Thermostat power must be cycled for changes in
dip switch configuration to take effect.
SHADED AREA SHOWS
SWITCH POSITION
7
1312 10
1
6
5
15 16
Y1 W1
O/W2
COM
NO1
DXM
Y1 W1
O G1
24V
HOT
SET
BACK
1312 10
2
6
5
15 16
Y W
O
R
C
REMOTE
SENSOR
CXM
ATA21S02 - TH158-004
Y1 W1
O
G2
24V
HOT
24V
COM
24V
COM
G
R
C
ACCESSORY
RELAY #1
REMOTE
SENSOR
7
1312 10
1
6 5 15 16
Y1 W1
O/W2
COM
NO1
DXM
Y1 W1
O G1
24V
HOT
SET
BACK
1312 10
1
6
5
15 16
Y W
O G
R
C
REMOTE
SENSOR
CXM
ATA21S01 - TH158-005
Y1 W1
O G1
24V
HOT
24V
COM
24V
COM
G
R
C
ACCESSORY
RELAY #1
REMOTE
SENSOR
2
G2
H
1
G
G1
NOTES:
1. Optional connection to pin “13” for heating stage 2 operation.
Heating stage 2 provides supplemental electric heat with compressor.
2. Optional remote room sensor. Jumper JP1 must be removed for
remote sensing. See FIGURE 1.
3. Optional connection for setback operation. DXM dip switches must
be configured for Accessory Relay #1 to operate in “Digital NBS”
mode.
4. DXM dip switch 2.7 must be configured for “HIGH FAN MODE”.
1 2
1
3
3
2
1 2
1
3
3
2
4
ELECTRICAL RATINGS
Voltage
Rating
24 VAC
10 VA
10 VA
Fan Switch
Pilot Duty
Thermostatic
Switching
ATA21S01 - TH158-005
ATA21S02 - TH158-004
AUTOAUTO
REMOVE JP1
FOR REMOTE SENSING
JP1JP1
FIGURE 1
  • Page 1 1
  • Page 2 2

ClimateMaster ATA21S01 and ATA21S02 Install Manual

Category
Thermostats
Type
Install Manual

ClimateMaster ATA21S01 and ATA21S02 are advanced heat pump thermostats designed to provide efficient and convenient temperature control in residential and light commercial applications. These thermostats offer a wide range of features to enhance comfort, reduce energy consumption, and simplify operation. With their user-friendly interface and comprehensive functionality, the ClimateMaster ATA21S01 and ATA21S02 thermostats empower users to create a customized and energy-efficient indoor environment.