DKS 1150 Quick start guide

Category
Garden tools
Type
Quick start guide

DKS 1150 is an overhead gate operator designed for gates up to 14 feet high and 25 feet wide, with features like automatic close timer, adjustable from 1 to 23 seconds, and a quick close function that stops the opening gate and closes it if all reversing inputs are cleared. It also has a self-test function for bench testing and supports various control options including 3-button control station, standalone keypad, push-button key switch, and radio receiver. Additionally, it offers entrapment protection with both non-contact and contact sensors.

DKS 1150 is an overhead gate operator designed for gates up to 14 feet high and 25 feet wide, with features like automatic close timer, adjustable from 1 to 23 seconds, and a quick close function that stops the opening gate and closes it if all reversing inputs are cleared. It also has a self-test function for bench testing and supports various control options including 3-button control station, standalone keypad, push-button key switch, and radio receiver. Additionally, it offers entrapment protection with both non-contact and contact sensors.

QUICKSTART “BASIC” GUIDELINES FOR MODEL 1150 - FOR OVERHEAD GATES UP TO 14 FEET HIGH AND 25 FEET WIDE
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
1150-066-E-3-13
Assemble Operator
Mount Operator
Secure rails to powerhead assembly
with 4 bolts, nuts and lock washers.
Manual Release
Limit Switches
Unlock,
Pull and
Turn Ring
Double Master Chain Link
Chain Tension Adjustment
Always adjust both sides of rails evenly.
CAUTION
FRAGILE POWERHEAD!
Sprocket
SW1
Auto Close Timer
High Voltage (Rigid Conduit)
Loop (Flexible Dry Conduit)
AC
ON/OFF
Switch
123
Board Adjustments
A
C
B
When SW1, switch 2 is turned ON,
automatic timer can be set from 1-23
seconds to automatically close gate.
1. ON
2. Auto Close Timer
3. ON
4. OFF
5. OFF
6. OFF
7. OFF
8. OFF
1. OFF
2. OFF
3. ON
4. OFF
1
ON
2 3 4
SW 2
Radio Receiver
Loop Detectors
E
Not included - Refer to the Owner’s manual
and Loop Information Manual (available from
www.dkaccess.com) for more information
on loops and loop detectors.
F
115 VAC Connection
Tip: It is recommended that a surge suppressor
be installed on the high voltage power lines.
DANGER
HIGH VOLTAGE!
D
OPERATOR MUST BE
PROPERLY GROUNDED!!
Route chain around gear reducer’s
sprocket and through unlocked
carriage assembly. Connect
chain together with double
master link.
Chain must not rub on steel rail separators.
Push and Hold Tab
Open
Limit
Nut
Push and hold locking plate tab
to adjust limit nuts at full open
and full close gate positions.
PUSH TO OPERATE
technician use only
Model 1150 is intended for installation only on overhead gates used for vehicles.
Pedestrians must be supplied with a separate access opening.
For safety and installation instructions, please refer to the owner’s manual.
F
CLOSE
OPEN
9410
9410
E
E
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
D
Close
Limit
Nut
LIMIT
LIMIT
PA RT
TIME
DELAY
REV SENSE
CLOSE
REV SENSE
OPEN
1
ON
2 3 4 1
ON
2 3 4 5 6 7 8
NO NC
EXIT
LOOP
REVERSE
LOOP
GATE FORCED
C
B
A
IMPORTANT: The carriage assembly’s spring
loaded chain catch will only lock into place
in the double master chain link.
Fill Mark
Install breather cap after operator has been mounted. Check
oil level, use Mobil SHC-629 synthetic gear oil or equivalent.
IMPORTANT: Gearbox should be filled to fill mark only.
Do not overfill.
Chassis Ground
Neutral (White)
Hot (Black)
After DIP-switches are changed, power must be
shut-off, and turned back on for new settings.
Close LED
Open LED
2.5” Minimum
Install the gate bracket “centered” on the top rail of the gate by bolting or welding. Center the header bracket above
the top of the gate bracket a minimum of 2.5 inches from the bottom of the header bracket. Check the gate’s opening
swing path, some gates will swing open higher than the bottom of the header
and could hit the rails if they are mounted too low. Mount header bracket with
lag bolts, anchor sleeves or welding to header.
Header
Install Breather Cap on Gearbox
Gate Bracket
Gate Bracket
Gate
Carriage Assembly
Header Bracket
If a ceiling extension bracket is needed, it must be
fabricated (2” wide L angle steel is recommended).
Install the powerhead with lag bolts or anchor
sleeves. Rails must be mounted level!
Ceiling
Connect the arms together with 2 bolts,
then connect them to the carriage assembly
and gate bracket.
Header
Bracket
Do not let chain rub against steel rail separators.
Chain tension adjustment. Adjust
equally on both sides of rails.
Header
Header and gate brackets must be level
and securely mounted!
Chain
Sprocket
Copyright 2013 DoorKing, Inc. All rights reserved.
See reverse side
See reverse side to wire main terminal.
Not included - Refer to a specific Radio Receiver
Manual (available from www.dkaccess.com) for
more information on radio receivers and antenna
installation. (See reverse side for wiring)
SW 1
SW 2
1
ON
2 3 4 5 6 7 8 1
ON
2 3 4
SW 1 DIP-Switches
SW 2 DIP-Switches
Note: After a DIP-switch setting is changed, power must be turned
OFF and then turned back on for the new setting to take affect.
3-Wire
Radio Receiver
Controls must be installed far enough from the gate so that the user is prevented from coming in contact with the gate while
operating the controls. Use 18 AWG wire for all low voltage wiring, maximum distance 3000 feet. Use a low voltage surge
suppressor, DoorKing P/N 1878-010 if low voltage wire runs exceed 1000 feet. All inputs to the main terminal must be
Normally Open (NO).
Com
Com
Relay
24 Volt
Com
Open
Close
Key SwitchLock Boxes Push Button
Stand-Alone
Keypad
Stand-Alone
Card Reader
Telephone Entry
3-Button Control Station
DoorKing ONLY
Entrapment Protection
Dry-Contact
Note: All stand-alone and
telephone entry devices must
use a separate power source.
NO NC
A
Non-contact sensor
Contact sensor
These systems can be used together.
B
A
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
B
Main Terminal
QUICKSTART “BASIC” GUIDELINES FOR MODEL 1150 - DIP-SWITCH AND WIRING REFERENCE
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Model 1150 is intended for installation only on overhead gates used for vehicles.
Pedestrians must be supplied with a separate access opening.
For safety and installation instructions, please refer to the owner’s manual.
Switch Function Setting Description
Change
Direction
EXIT Loop
Port
OFF
ON
OFF
OFF
ON
4-OFF
4-OFF
4-ON
4-ON
5-OFF
5-ON
5-OFF
5-ON
Auto-Close
Timer
Relay
Not Used
Reverse and Open
Stop then Close
Quick
Close
1
2
3
7
8
6
4 and 5
Changes open/close direction operator should cycle open upon initial power up.
Normal setting.
EXIT loop port output is sent to terminal 4 for secondary slide gate operator only.
Normal setting. EXIT loop port output is sent directly to circuit board.
Normal setting.
OFF
ON
OFF
ON
Auto-close timer is OFF. Manual input (push control button) required to close gate.
Auto=close timer is ON. Adjustable from 1-23 seconds.
Normal Setting. During close cycle, input to terminal 7 will reverse and open gate.
During close cycle, input to terminal 7 stops gate, after input removed, closes gate.
OFF
ON
Normal Setting. Normal gate operation.
Opening gate will stop, then close as soon as all reversing inputs (loops, beams)
have been cleared by vehicle regardless of how far the gate has opened.
Relay activates when gate is full open.
Relay activates when gate is not closed.
Relay activates when gate is opening and open.
Relay activates when gate is opening and closing.
OFF
OFF
Not Used
Normal setting.
Not Used
Normal setting.
Switch Function Setting Description
Self Test
OFF
ON
1
2
3
4
Normal Setting.
Run self test - bench testing only. Operator must not be connected to gate!
Slide Gate
Overhead Gate
OFF
ON
Normal setting. Must be in the ON position for overhead gate operator.
  • Page 1 1
  • Page 2 2

DKS 1150 Quick start guide

Category
Garden tools
Type
Quick start guide

DKS 1150 is an overhead gate operator designed for gates up to 14 feet high and 25 feet wide, with features like automatic close timer, adjustable from 1 to 23 seconds, and a quick close function that stops the opening gate and closes it if all reversing inputs are cleared. It also has a self-test function for bench testing and supports various control options including 3-button control station, standalone keypad, push-button key switch, and radio receiver. Additionally, it offers entrapment protection with both non-contact and contact sensors.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI