GB
.
.
standards.
It is not permissible to install the stove in
bedrooms, bathrooms, or in a room where
another heating appliance is installed
(fireplace, stove etc.) which does not have its own
independent air intake.
atmosphere is prohibited.
The floor of the room where the stove is to be
installed must be strong enough to take its weight. If
walls are flammable, maintain a minimum distance
of 10 cm at the rear (A), of 30 cm at the side (B) and
150 cm at the front. If the room contains objects
which are believed to be particularly delicate, such
as drapes, sofas and other furniture, their distance
from the stove should be considerably increased.
Operating area
30 cm
(B)
Min.
150 cm
2
10 cm (A)
Connection to the external air intake
installed
In the presence of wood floors, install a
floor protection surface in compliance
with the rules in force in the country
Is necessary to connect the stove to
the outside air intake pipes and fittings
that guarantee the tightness to meet the
requirements of the sealed stove.
Connection to the combustion air inlet tube