ESAB LAX 380 is a step switched power source, intended for use together with the wire feed units MEK 2 and MEK 4 for welding with solid steel, stainless steel or aluminum wire as well as tubular wire with or without shielding gas. It offers precise control over the welding process with its wide setting range of 50A/17V to 380A/33V, allowing you to fine-tune your welds for optimal results. Equipped with efficient cooling system, it ensures reliable performance even during extended welding sessions.

ESAB LAX 380 is a step switched power source, intended for use together with the wire feed units MEK 2 and MEK 4 for welding with solid steel, stainless steel or aluminum wire as well as tubular wire with or without shielding gas. It offers precise control over the welding process with its wide setting range of 50A/17V to 380A/33V, allowing you to fine-tune your welds for optimal results. Equipped with efficient cooling system, it ensures reliable performance even during extended welding sessions.

LAX 320 valid for serial no. 005--xxx--xxxx
LAX 380 valid for serial no. 645--xxx--xxxx0455 640 101 011001
LAX 320 - 380WI
LAX 320/320I/
380/380W/380I/380WI
101103105107109111102021110025108024042106023061104022041100020040060001
Bruksanvisning
Brugsanvisning
Bruksanvisning
Käyttöohjeet
Instruction manual
Betriebsanweisung
Manuel d’instructions
Gebruiksaanwijzing
Instrucciones de uso
Istruzioni per l’uso
Manual de instruções
Ïäçãßåò ÷ñÞóåùò
-- 2 --
Rätt till ändring av specifikationer utan avisering förbehålles.
Ret til ændring af specifikationer uden varsel forbeholdes.
Rett til å endre spesifikasjoner uten varsel forbeholdes.
Oikeudet muutoksiin pidätetään.
Rights reserved to alter specifications without notice.
Änderungen vorbehalten.
Sous réserve de modifications sans avis préalable.
Recht op wijzigingen zonder voorafgaande mededeling voorbehouden.
Reservado el derecho de cambiar las especificaciones sin previo aviso.
Ci riserviamo il diritto di variare le specifiche senza preavviso.
Reservamo--nos o direito de alterar as especificações sem aviso prévio.
Äéáôçñåßôáé ôï äéêáßùìá ôñïðïðïßçóçò ðñïäéáãñáöþí ×ùñßò ðñïåéäïðïßçóç.
SVENSKA 3..............................................
DANSK 11................................................
NORSK 19................................................
SUOMI 27................................................
ENGLISH 35..............................................
DEUTSCH 43.............................................
FRANÇAIS 51.............................................
NEDERLANDS 59.........................................
ESPAÑOL 67..............................................
ITALIANO 75..............................................
PORTUGUÊS 83..........................................
ÅËËÇÍÉÊÁ 91.............................................
ENGLISH
-- 3 5 --
TOCe
1 DIRECTIVE 36........................................................
2SAFETY 36...........................................................
3 INTRODUCTION 37...................................................
3.1 Standard delivery 37..........................................................
4 TECHNICAL DATA 37.................................................
5 INSTALLATION 38....................................................
5.1 Assembly of components 39...................................................
5.2 Electrical installation 39.......................................................
5.3 Mains supply 40..............................................................
6 OPERATION 40.......................................................
7 MAINTENANCE 41....................................................
7.1 Topping up coolant 41.........................................................
8 ORDERING OF SPARE PARTS 42......................................
DIAGRAM 99............................................................
SPARE PARTS LIST 103...................................................
ACCESSORIES 118.......................................................
-- 3 6 --
ba15d1ea
1 DIRECTIVE
DECLARATION OF CONFORMITY
Esab Welding Equipment AB, S--695 81 Laxå, Sweden, gives its unreserved guaran-
tee that welding power source LAX 320/320I/380/380W/380I/380WI from serial
number 521/550 complies with standard EN 60974--1, in accordance with the re-
quirements of directive (73/23/EEC) and addendum (93/68/EEC) and with standard
EN 50199 in accordance with the requirements of directive (89/336/EEC) and add-
endum (93/68/EEC).
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --------
Paul Karlsson
Managing Director
Esab Welding Equipment AB
695 81 LAXÅ
SWEDEN Tel: + 46 584 81000 Fax: + 46 584 12336
Laxå 95--12--10
2SAFETY
WARNING
READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING.
ARC WELDING AND CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE PRECAU -
TIONS WHEN WELDING. ASK FOR YOUR EMPLOYER’S SAFETY PRACTICES WHICH SHOULD BE
BASED ON MANUFACTURERS’ HAZARD DATA.
ELECTRIC SHOCK -- Can kill
S Install and earth the welding unit in accordance with applicable s tandards.
S Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing.
S Insulate yourself from earth and the workpiece.
S Ensure your working stance is safe.
FUMES AND GASES -- Can be dangerous to health
S Keep your head out of the fumes.
S Use ventilation, extraction at the arc, or both, to take fumes and gases away from your breathing zone
and the general area.
ARC RAYS -- Can injure eyes and burn skin.
S Protect your eyes and body. Use the correct welding s creen and filter lens and wear protective
clothing.
S Protect bystanders with suitable screens or curtains.
FIRE HAZARD
S Sparks (spatter) can cause fire. Make sure therefore that there are no inflammable materials nearby.
NOISE -- Excessive noise can damage hearing
S Protect your ears. Use earmuffs or other hearing protection.
S Warn bystanders of the risk.
MALFUNCTION -- Call for expert assistance in the event of malfunction.
PROTECT YOURSELF AND OTHERS!
Do not use the power source for thawing frozen pipes.
WARNING!
GB
-- 3 7 --
ba15d1ea
3 INTRODUCTION
LAX 320/320I is a step switched power source, intended for use together with the
wire feed unit MEK 2 for welding with solid steel, stainless steel or aluminium wire as
well as tubular wire with or without shielding gas.
LAX 320/380I/380W/380WI is step switched power sources, intended for use to-
gether with the wire feed units MEK 2 and MEK 4 for welding with solid steel, stain -
less steel or aluminium wire as well as tubular wire with or without shielding gas.
See p ag e 118 for details of ESAB’s accessories for the power source.
3.1 Standard delivery
LAX 320/320I
Power source.
Return cable 4.5 m with return clamp.
Mains cable 5 m and gas hose.
Includes: Handle, (fitted with 2 screws), gas cylinder shelf (fitted with 2 screws).
Post for wire feed unit.
LAX 380/380I/380W/380WI
Power source, can be supplied with or without water cooling unit..
Return cable 5 m with return clamp.
Mains cable 5 m and gas hose.
Includes: Gas cylinder shelf, (fitted with 2 screws). Post for wire feed unit.
4 TECHNICAL DATA
LAX 320/320I
Voltage 400--415V, 3
50/60 Hz 230/400--415/500V 3
50 Hz
230/440--460 3
60Hz
Permissible load at
100 % duty cycle
195 A/24 V 195 A/24 V
at 60 % duty cycle 250 A/27 V 250 A/27 V
at 30 % duty cycle 320 A/30 V 320 A/30 V
Setting range (DC) 40A/16V--320A/30V 40A/16V--320A/30V
Open circuit voltage 16--40 V 16--40 V
Open circuit power 50 W 50 W
Efficiency 0,71 0,71
Power factor 0,97 0,97
Control voltage 42 V, 50/60 Hz 42 V, 50/60 Hz
Dimensions lxwxh 770 x 560 x 640 770 x 560 x 640
Weight 110 kg 110 kg
Enclosure class IP 23 IP 23
Application classification
GB
-- 3 8 --
ba15d1ea
LAX 380/380I/380W/380WI
Voltage 400--415V, 3
50/60 Hz 230/400--415/500V 3
50 Hz
230/440--460 3
60Hz
Permissible load at
100 % duty cycle
280 A/28 V 280 A/28 V
at 60 % duty cycle 350 A/32 V 350 A/32 V
at 50 % duty cycle 380 A/33 V 380 A/33 V
Setting range (DC) 50A/17V--380A/33V 50A/17V--380A/33V
Open circuit voltage 17--45 V 17--45 V
Open circuit power 130 W
340 W (LAX380W/WI)
130 W
340 W (LAX380W/WI)
Efficiency 0,75 0,75
Power factor 0,96 0,96
Control voltage 42 V, 50/60 Hz 42 V, 50/60 Hz
Dimensions lxwxh 800x640x835 800x640x835
Weight 143 kg
157 kg (LAX380W/WI)
143 kg
157 kg (LAX380W/WI)
Enclosure class IP 23 IP 23
Application classification
Duty cycle
The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a cer-
tain load without overloading the welding power source.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP 23 is designed for indoor and outdoor use.
Application class
The symbol indicates that the power source is designed for use in areas with increased
electrical hazard.
5 INSTALLATION
The installation must be executed by a professional.
WARNING!
This product is intended for industrial use. In a domestic environment this product may cause radio
interference. It is the user’s responsibility to take adequate precautions.
The power supply should be lifted by means of its lifting
eye. The handle is only intended for pulling it along the
ground.
Lifting instructions
Connect the power supply lead using the appropriate fuse in conformance with local
regulations.
Cable areas acc. to Swedish regulations. Make sure the welding r ectifier is not cov-
ered or positioned so that cooling is obstructed.
GB
-- 3 9 --
ba15d1ea
5.1 Assembly of components
ba15s00
3
5.2 Electrical installation
ba15
s005
ba14
s006
ba14
s007
XT1
TC1
GB
-- 4 0 --
ba15d1ea
5.3 Mains supply
LAX 320/320I 3 50 Hz 3 5060 Hz 3 50 Hz 3 60 Hz 3 60 Hz
Voltage V 230 400/415 500 230 440/460
Current A at100% duty cycle 16 9 7 16 8
at 60% duty cycle 23 14 10 23 12
at 30% duty cycle 35 20 16 34 18
Cable area mm
2
22
2
4x4 4x2,5 4x2,5 4x4 4x2,5
Fuse, slow A 20 16 16 20 16
LAX 380/380I/380W/380WI 3 50 Hz 3 50/60 Hz 3 50 Hz 3 60 Hz 3 60 Hz
Voltage V 230 400/415 500 230 440/460
Current A at100% duty cycle 28 16 13 28 14
at 60% duty cycle 41 23 18 40 20
at 50% duty cycle 45 27 20 45 22
Cable area mm
2
22
2
4x6 4x2,5 4x2,5 4x6 4x2,5
Fuse, slow A 35 20 20 35 20
6 OPERATION
A Main switch on/off G Inductance connection
B Voltage selector 4--step H Welding socket + pol.
C Voltage selector 10--step J Sleeve socket 23--pol. wire feed unit
D Indicator lamp thermal overload, lights up in
case of overheating
K Automatic fuse 42 V AC--circuit
E Mains indicator lamp L Quick coupling water, LAX 380
F Space for digital meters (optional)
GB
-- 4 1 --
ba15d1ea
A thermal cut--out prevents overheating. Resetting takes place automatically when
the power source has cooled.
The power sources can be equipped with instruments to display the current and vol -
tage. The instruments have a hold function and can be calibrated.
7 MAINTENANCE
Note:
All warranty undertakings given by the supplier cease to apply if the customer
attempts to rectify any faults on the m achine during the warranty period.
Only those persons who have appropriate electrical knowledge (authorised
personnel) may remove the safety plates to connect or carry out service,
maintenance or repair work on welding equipment.
Cleaning
Check r egularly that the power source is free from dirt.
How often, and to what extent, cleaning should be carried out depends on the
welding process, arc time, disposition and the surrounding environment. It will
normally suffice to blow the power source clean using compressed air (reduced
pressure) once a year.
If the power source is very dirty, brushing and vacuuming are recommended.
S Disconnect the welding power source from the mains current supply.
S Remove the adapter from the socket. Lock the socket to prevent unauthorised
connection.
At fixed installations, the safety switch should be set to the off position. Lock
the switch.
S Remove the power source’s safety plates for best access.
After cleaning, all safety plates must be mounted before you connect the power
source to the mains supply.
7.1 Topping up coolant
We recommend a 50/50 % mixture of water and ethylene glycol.
ba11kyl
a
GB
-- 4 2 --
ba15d1ea
There is a risk of tipping if the wire feed cabinet is fitted with a counterbalance arm. Secure the
equipment, especially if used on an uneven or sloping surface.
Limit the angle of rotation of the wire feed cabinet using the straps supplied.
When moving the equipment, do NOT pull on the torch.
WARNING!
8 ORDERING OF SPARE PARTS
LAX 320/320I/380/380W/380I/380WI is designed and tested in accordance
with the EN 60974--1 (IEC 60974--1) international standard.
It is the obligation of the service unit which has carried out the service or re-
pair work to make sure that the product still conforms to the said standard.
Spare parts are ordered through your nearest ESAB representative, see back cover.
When ordering spare parts, please state machine type and number as well as desig-
nation and spare part number as shown in the spare parts list.
This will simplify dispatch and ensure you get the right part.
GB
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

ESAB LAX 380 User manual

Category
Welding System
Type
User manual
This manual is also suitable for

ESAB LAX 380 is a step switched power source, intended for use together with the wire feed units MEK 2 and MEK 4 for welding with solid steel, stainless steel or aluminum wire as well as tubular wire with or without shielding gas. It offers precise control over the welding process with its wide setting range of 50A/17V to 380A/33V, allowing you to fine-tune your welds for optimal results. Equipped with efficient cooling system, it ensures reliable performance even during extended welding sessions.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI