  • Hello! I am an AI chatbot trained to assist you with the Whirlpool AKM 202/IX Program Chart. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • How do I ignite a burner on the Whirlpool AKM 202/NB cooktop?
    What should I do if the burner doesn't ignite?
    What are the dimensions of the cooktop and worktop?
    What type of gas can I use with the Whirlpool AKM 202/NB cooktop?
    What are the injector markings and rated heat capacities for each burner type and gas type?
    What is the total rated heat capacity and consumption for the Whirlpool AKM 202/NB cooktop?
    How much air is required for burning for each gas type?
AKM 202 PRODUCT DESCRIPTION SHEET
GB
5019 319 01219
Operation of burners
electronic ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star
setting .
At the same time, keep the knob pressed
against the control panel until the burner
ignites.
Release the knob.
If the burner does not ignite, repeat the
operations described above.
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
Symbols
Shaded circle Tap closed
Large Maximum opening/
flame delivery and electronic
and star ignition
Small Minimum opening or
flame reduced delivery
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas
used
Type o f
burner
Injector
marking
Rated
heat
capacity
Pcs-kW
Rated
consumption
Reduced
heat
capacity
Pcs-kW
Gas pressure
min. rat. max.
NATURAL GAS
(Methane) G20
large
medium
small
128
94
76
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
17 20 25
NATURAL GAS
(Groningen) G25
large
medium
small
128
94
76
2.78
1.53
0.93
308 l/h
170 l/h
103 l/h
0.60
0.35
0.30
20 25 30
LIQUID
PETROLEUM GAS
(Cylinder) G30
large
medium
small
85
65
50
3.00
1.65
1.00
218 l/h
120 l/h
73 l/h
0.60
0.35
0.30
20 28-30 35
LIQUID
PETROLEUM GAS
(Cylinder) G31
large
medium
small
85
65
50
3.00
1.65
1.00
214 l/h
118 l/h
71 l/h
0.60
0.35
0.30
25 37 45
Type o f g as
used
Appliance
model
Total rated
heat capacity
Pcs-kW
Total rated
consumption
Air required
for burning
m
3
/h
G20 20 mbar 4 gas 7.30 695 l/h 14.6
G25 25 mbar 4 gas 6.77 751 l/h 13.5
G30 28-30 mbar 4 gas 7.30 531 l/h 14.6
G31 37 mbar 4 gas 7.30 521 l/h 14.6
/