Please observe the following safety precau-
tions when using the air conditioner.
Failure or negligence in observing these safety
precautions could causere, electrical shock or
personal injury.
Precautions during installation
Please ask your sales agent or qualified techni-
cian for the installation of your unit. Water
leakage, short circuit orre may occur if you
install the unit by yourself.
Please use earth line.
Do not place the earth line near water or gas
pipes, lightning-conductor, or earth line of
telephone. Improper grounding could cause
electric shock.
A circuit breaker should be installed depending on
the mounting site of the unit. Without a circuit
breaker, the danger of electric shock exists.
Do not install near location where there is
flammable gas. The unit may catch fire if
flammable gas leaks around it.
WARNING
CAUTION
Precautions during operation
Avoid an extended period of direct air flow. It
could lead to health problems.
Do not modify the length of power cord or use an
extension cord. It could cause electrical shock or
fire.
Do not attempt to operate the unit with wet
hands, this could cause fatal accident.
Do not turn on the unit by inserting the power
cord.
Please switch off the unit and turn off the circuit
breaker during cleaning, the high speed fan
inside the unit may cause danger.
Turn off the circuit breaker if the unit is not
operated for a long period.
Do not splash or direct water to the body of the
unit when cleaning as it may cause short circuit.
Do not block the air intake and outlet vanes,
cooling performance will be affected.
CAUTION
SAFETY PRECAUTIONS
OWNER’S MANUAL
ROOM AIR CONDITIONER
OPERATION INSTRUCTIONS (Open the control door to access the controls)
OFF
This position stops all operations
of the air conditioner.
HIGH COOL
This position provides the
maximum air flow for rapid
cooling, dehumidifying and dust
removing operations (use this
position on sultry summer days).
FAN ONLY
This position provides fan operation alone
for air circulation and dust removal from
air.
Thermostat knob
The thermostat automatically starts and
stops the operation in order to keep the
room temperature at a proper level, and
this results in efficient use of power and
cooling. Turn the knob clockwise for cooler
temperature and counterclockwise for
warmer temperature settings.
MED COOL
This position provides the moderate air flow for
quiet cooling, dehumidifying and dust removing
operations (use this position when the outdoor
temperatures are likely to be lower).
LOW COOL
This position provides the minimum air flow for
quiet cooling, dehumidifying and dust removing
operations. (Suitable for night-time use)
Air Directional Louvers
The louvers will allow you to direct the air flow
Left or Right throughout the room as needed.
Move the Center handle from side to side until
the desired Left/Right direction is obtained.
Center handle
Selector knob
Location
Avoid installing the air conditioner where it is
exposed to direct sunlight.
The air conditioner should be installed with a
strong external support to minimize noise and
vibration and for the purpose of safe installation,
repair, replacement and secure positioning.
AIR CONDITIONING INSTALLATION
Installations of the unit into the wall
75~150cm
AWNING
About 10mm
Note: Unit may be supported by a solid frame
from below or by a hanger from a solid
overhead support.
BRICK
WALL
BRICK
WALL
AIR IN AIR IN
LOUVER
AIR OUT
FRONT
100mm
100mm
45° BRICK CUT AWAY
TO CLEAR LOUVERS
45° BRICK CUT AWAY
TO CLEAR LOUVERS
AIR IN AIR OUT
AIR IN
AIR IN
100mm minimum
Clean your air conditioner occasionally to keep it
looking new. Be sure to unplug the unit before
cleaning to prevent shock or fire hazards.
CARE AND MAINTENANCE
If the air filter becomes clogged with dust, smooth
air flow is obstructed and cooling efficiency
becomes low.
Air Filter Cleaning
Unscrew the front grille on both sides. Pull the filter
out of the unit.
Wash the filter using liquid dishwashing detergent
and warm water. Rinse filter thoroughly.
Gently shake excess water from the filter. Be sure
the filter is thoroughly dry before replacing.
Fix the unit with bracket and secure it with screws
Bracket
Dimension (Clearances)
W
H
Prepare an installation hole slightly bigger
than the outer wrapper size.
H = 314mm
W = 412mm
BRACKET
100mm
CALL CENTER AND REGIONAL OFFICES
863-5555 – GMA HOTLINE
TOLL FREE HOTLINEPROVINCIAL
1 800 – 108 – 888888 – PLDT
1 8003 – 863 - 5555DIGITEL
For Provincial areas, just contact our regional ofces
DAGUPAN REGIONAL OFFICE
Star Bldg. Arellano St., Dagupan City
Tel. No.: (075) 522-9555
Fax No.: (075) 515-7899
(075) 522-9555
CEBU REGIONAL OFFICE
AC Cortez Ave., Cor Rizal St.
Mandaue City
Tel. No.: (032) 344 -7773
(032) 344 -7131
Fax No.: (032) 344 -7132
DAVAO REGIONAL OFFICE
Cruz Building, Dacudao Avenue,
Davao City
Tel. No.: (082) 222-6614
(082) 222-6615
Fax No.: (082) 221-3633
SAN FERNANDO REGIONAL OFFICE
PSP Bldg. GapanOlongapo Road
Dolores, San Fernando Pampanga
Tel. No.: (045) 963-0178
Fax No.: (045) 963-0164
(045) 963-0178
ILOILO REGIONAL OFFICE
Door #2 RTG Bldg. Quezon Avenue
Iloilo City
Tel. No.: (033) 335 - 0687
(033) 336 - 4550
Fax No.: (033) 335 - 0687
BICOL REGIONAL OFFICE
MMCN Bldg. Brgy. Panganiban Drive
Concepcion,Naga City
Tel. No.: (054) 473-3144
Fax No.: (054) 473-3149
CAGAYAN DE ORO REGIONAL OFFICE
Cor. Yacapin & Capistrano St.,
Cagayan De Oro City
Tel. No.: (088) 231-2152
Fax No.: (088) 856-8587
FASTxt LINE
0917- 843-5555
0917 - 842-5555
1. Blown fuse.
2. Circuit Breaker tripped.
3. Unit cord unplugged.
4. Supply voltage too low.
1. Airlter dirty.
2. Improper thermostat setting.
3. Check if unit is exposed to sunlight.
1. The fan may be hitting foreign mat’l.
2. Check fan motor bearing.
1. Low outside temperature.
2. Airlter dirty.
3. Check system for leak.
4. Check thermostat.
TROUBLESHOOTING GUIDE
PROBLEM POSSIBLE CAUSE SOLUTION
1. Replace only once.
2. Reset only once.
3. Replug into wall receptacle.
4. Consult electrician.
1. Clean air filter.
2. Reset to desired temperature setting.
3. Provide awning.
1. Adjust fan position or remove foreign mat’l.
2. Replace fan motor.
1. Operate fan w/o cooling until the frost disappear
2. Clean air filter.
3. Repair and recharge.
4. Replace thermostat if defective.
Unit does not
start
Unit does not
cool properly
Fan motor
does not run
Ice of frost
forms on the
indoor coil
P/N: 04204910192-00
OWNER: MODEL:
ADDRESS: SERIAL NO.:
TEL. NO.: E-MAIL:
DEALER/BRANCH: PURCHASE DATE:
WARRANTY REGISTRATION
ONE YEAR WARRANTY ON PARTS AND LABOR
Concepcion-Carrier Air Conditioning Co., warrants this Room Air Conditioner to the original
purchaser/user to be free from defects in material and workmanship. We shall, within one year
from the date of purchase, repair the unit at no cost to the original purchaser/user using the
original parts or their equivalent subject to warranty exclusions.
WARRANTY EXCLUSIONS
Unit subject to misuse, abuse, neglect, accident, alternation, cleaning or servicing by
non-CCAC accredited service centers.
Unit installed on harsh environment e.g. sea going vessel, port area, power plant, chemical
laboratories, kitchen, etc.
Abnormal voltage conditions i.e. unstable and or fluctuating voltage.
Lack of proper maintenance i.e. regular inspection and cleaning air filters & cooling coils (for
non-residential applications).
Units not rendered for cleaning once every six months by authorized service center during
the duration of warranty period.
Improper unit installation i.e. obstructed discharge and fresh air intake, under capacity etc.
All direct, indirect or consequential injury, loss or damage arising out of the use or inability to
use the product.
Force majeure, Acts of God and all other fortuitous events.
Units not registered within one (1) year from the date of purchase.
NOTE: To register product warranty, call i-Assist at 863-5555 or visit our website:
www.ccac.com.ph or fill up and detach Warranty Registration Card and mail. Registration must be
done within ten (10) days from the date of purchase
Please affix your proof of purchase here for future reference.
PRODUCT WARRANTY
CERTIFICATE
FOUR YEAR LIMITED COMPRESSOR WARRANTY EXTENSION
The compressor (part only, excluding unit pull-out and delivery charges, accessories, labor and
expendable material charges) shall be covered by a four (4) year warranty extension subject to
the warranty exclusions. No other warranties shall apply.
CONCEPCION – CARRIER AIR CONDITIONING CO.
Km. 20 East Service Road, South Superhighway
Alabang, Muntinlupa City
MODEL:
SERIAL NO.:
( CUSTOMER’S COPY )
A warranty Certificate is included with your unit. Warranty coverage becomes effective on the date
of sale. Therefore, it is a good idea to keep your bill of sale and warranty in a safe place with your
Owner’s Handbook.
WARRANTY CERTIFICATE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Condura ROOM AIR CONDITIONER Owner's manual

Category
Computer liquid cooling
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI