Vacmaster VF408 Wet or Dry Shop Vacuum Cleaner Owner's manual

Category
Vacuum cleaners
Type
Owner's manual
Distributed By
Cleva North America, Inc.
601 Regent Park Court
Greenville, SC 29607
Replacement Filters &
Accessories available at:
Vacmaster.com
FOR YOUR SAFETY
Read and understand this manual before use.
Keep this manual for future reference.
4 Gallon
Model No.
VF408
Operators Manual
Wet/Dry Vacuum
2
TABLE OF CONTENTS
WARRANTY
Warranty .......................................................................................................................................
Safety Instructions & Warnings ....................................................................................................
Double Insulation Instructions ......................................................................................................
Extension Cords ...........................................................................................................................
Unpacking & Checking Carton Contents ......................................................................................
General Assembly Instructions .....................................................................................................
Dry Vacuum Operation .................................................................................................................
Liquid Vacuum Operation .............................................................................................................
Maintenance .................................................................................................................................
Installing & Cleaning Cartridge Filter ............................................................................................
Installing & Cleaning Foam Wet Filter ..........................................................................................
Troubleshooting ............................................................................................................................
Exploded View ..............................................................................................................................
Parts List.......................................................................................................................................
2
3
4
4
5
6
7
8
9
10
11
11
12
13
SECTION PAGE
Thank you for purchasing this Vacmaster® wet/dry vacuum cleaner. Feel condent that with
Vacmaster® you are obtaining a high quality product engineered for optimal performance.
This vacuum is capable of picking up liquids and dry materials.
FOR YOUR SAFETY: CAREFULLY READ AND UNDERSTAND ALL INSTRUCTIONS.
We take pride in producing a high quality, durable product. This Vacmaster® product carries a
limited two (2) year warranty against defects in workmanship and materials from date of purchase
under normal household use. If product is to be used for commercial, industrial, or rental use, a
90 day limited warranty will apply. Please keep your receipt as proof of purchase. This warranty
gives you specic legal rights, which may vary from state to state. For product service call
Customer Service at 1-866-384-8432.
Not Covered by Warranty:
Any part that has become inoperative due to misuse, negligence, direct/indirect abuse, accidents,
improper maintenance, repairs, or alterations;
• Consumables such as lters and accessories;
• Normal wear and tear of parts and attachments, such as hose, nozzles, or casters;
• Normal deterioration of the exterior nish due to use or exposure;
Any product where serial number/data label is tampered with or removed;
Any product purchased from an unauthorized retailer.
3
SAFETY INSTRUCTIONS & WARNINGS
IMPORTANT SAFETY INSTRUCTIONS
SAVE THIS MANUAL
WARNING:
FOR FUTURE REFERENCE.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY:
READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE USING THIS VACUUM.
Read and understand this operator's manual and all labels on the Wet/Dry Vacuum cleaner before
operating. Safety is a combination of common sense, staying alert, and knowing how your vacuum
works. Use this Wet/Dry Vac only as described in this manual. To reduce the risk of personal
injury or damage to your Wet/Dry Vac, use only Vacmaster® recommended accessories.
When using an electrical appliance, basic precautions should always be followed
including the following:
• Do not run vac unattended.
• Do not vacuum, or use this Wet/Dry Vac near ammable liquids, gases, or explosive vapors
like gasoline or other fuels, lighter uids, cleaners, oil-based paints, natural gas, hydrogen, or
explosive dusts like coal dust, magnesium dust, grain dust, or gun powder. Sparks inside the
motor can ignite ammable vapors or dust.
• Do not vacuum anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
• Keep cord away from heated surfaces.
• Do not expose to rain. Store indoors.
• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
• Do not use with damaged cord, plug, or other parts.
• If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped
into water, return it to a service center.
• Do not pull or carry by cord, use cord as handle, close a door on cord, or pull cord around sharp
edges or corners.
• Do not run Wet/Dry Vac over cord.
• Do not handle plug or the Wet/Dry Vac with wet hands.
• To reduce the risk of health hazards from vapors or dusts, do not vacuum toxic materials.
• Do not use or store near hazardous materials.
• Do not use this Wet/Dry Vac with a torn lter or without the lter installed except when
vacuuming liquids as described in the operation section of this manual.
• Do not allow to be used as a toy. Close attention is necessary when used by or near children.
• To reduce the risk of injury from accidental starting, unplug power cord before changing or
cleaning lter.
• Do not leave Wet/Dry Vac unattended when plugged in. Unplug from outlet when not in use and
before servicing.
• Turn off Wet/Dry Vac before unplugging.
• Do not put any object into ventilation openings. Do not vacuum with any ventilation openings
blocked; keep free of dust, lint, hair, or anything that may reduce air ow.
• Keep hair, loose clothing, ngers, and all parts of body away from openings and moving parts.
• To reduce the risk of falls, use extra care when cleaning on stairs.
• Unplug before connecting hose.
• Use only as described in this manual. Use only manufacturers recommended attachments.
• This appliance is provided with double insulation. Use only identical replacement parts. See
“DOUBLE INSULATION INSTRUCTIONS”.
Household Type
4
DOUBLE INSULATION INSTRUCTIONS
EXTENSION CORDS
This Wet/Dry Vac is double-insulated, eliminating the need for a separate grounding system. Use
only identical replacements parts. Read the instructions for Servicing Double-Insulated Wet/Dry
Vacs before servicing. Use this Wet/Dry Vac as described in this manual. Observe the following
warnings that appear on the motor housing of your Wet/Dry Vac.
When using an extension cord with your Wet/Dry Vac refer to the following table to determine
the required A.W.G. wire size. Before using the vacuum cleaner, make sure the power cord and
extension cord are in good working condition. Make repairs or replacements before using the
vacuum cleaner. Only use extension cords that are rated for outdoor use.
• DO NOT use without lters in place.
CAUTION: TO REDUCE THE RISK OF INJURY FROM MOVING PARTS, UNPLUG BEFORE
SERVICING.
CAUTION:
Do not vacuum drywall dust or replace soot or ash with standard Wet/Dry lter. This is a very ne
dust which will not be captured by the lter and may cause damage to motor. When vacuuming
ne dust use a ne dust lter (sold separately).
DOUBLE INSULATED - GROUNDING NOT REQUIRED - WHEN SERVICING USE
ONLY IDENTICAL REPLACEMENT PARTS.
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN.
STORE INDOORS.
WARNING:
Length of Extension Cord
A.W.G. Wire Size
Not recommended
25 Feet
7.5 Meters
50 Feet
15.25 Meters
100 Feet
30.5 Meters
150 Feet
45.7 Meters
110V-120V
Amps
0-6
7-10
11-12
13-16
18
18
16
14
16
16
16
12
16
14
14
14
12
12
WARNING:
WITH A DOUBLE-INSULATED WET/DRY VACUUM, TWO SYSTEMS OF INSULATION ARE
PROVIDED INSTEAD OF GROUNDING. NO GROUNDING MEANS IS PROVIDED ON A
DOUBLE-INSULATED APPLIANCE, NOR SHOULD A MEANS FOR GROUNDING BE ADDED.
SERVICING A DOUBLE INSULATED WET/DRY VACUUM REQUIRES EXTREME CARE AND
KNOWLEDGE OF THE SYSTEM, AND SHOULD BE DONE ONLY BY QUALIFIED SERVICE
PERSONNEL. REPLACEMENT PARTS FOR A DOUBLE-INSULATED WET/DRY VACUUM
MUST BE IDENTICAL TO THE PARTS THEY REPLACE. YOUR DOUBLE-INSULATED
WET/DRY VAC IS MARKED WITH THE WORDS ‘DOUBLE INSULATED’ AND THE SYMBOL
(SQUARE WITHIN A SQUARE) MAY ALSO BE MARKED ON THE APPLIANCE.
SERVICING OF DOUBLE-INSULATED WET/DRY VACUUM
5
UNPACKING & CHECKING CARTON
CONTENTS
Remove all contents from the box. Remove the
power head and take out any contents inside
the collection tank. Check each item against
the carton contents list.
NOTE: The hose and accessories for this
vacuum are 1.25” (3.2 cm) diameter.
A
BCDE
FG H I J
K L MN
O P QRS
Carton Contents List:
Description............................................
Vac Assembly........................................
Hose......................................................
2-in-1 Utility Nozzle...............................
Round Dust Brush.................................
Crevice Tool...........................................
Multi-Surface Floor Nozzle....................
Cartridge Filter.......................................
Filter Retainer........................................
Foam Wet Filter.....................................
Accessory Storage Caddy.....................
Extension Wand....................................
Hose Storage Rack...............................
HEPA Filter Door...................................
HEPA Filter............................................
Casters..................................................
Rear Wheels..........................................
Handle...................................................
4 Screws (Bag)......................................
Operator’s Manual.................................
Key
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
Qty.
1
1
1
1
1
1
1
1
1
1
3
2
1
1
2
2
1
1
1
Cord Rewind Button
Rear Wheel
Latch
Casters
Power Head
Hose Storage Rack
Tool Caddy
Vacuum Port
Handle
Power Switch
Collection Tank
6
GENERAL ASSEMBLY INSTRUCTIONS
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN.
MAKE SURE PLUG IS DISCONNECTED BEFORE ASSEMBLING THE WET/DRY VAC.
WARNING:
UNPACKING YOUR WET/DRY VACUUM & GENERAL ASSEMBLY
1. Verify that the power cord is disconnected from the outlet. (g. 1)
2. Undo the latches. (g. 2)
3. Lift the power head off the collection tank. (g. 3)
4. Remove the contents from inside the collection tank; make sure you have all contents as listed
on page 5. (g. 4)
5. Turn the collection tank upside down and insert the two (2) casters into the slots on the front
side of the collection tank. Apply downward pressure until the casters snap into place. (g. 5)
6. Slide the rear wheels into the slots making sure to match the wheel number to the
corresponding number on the wheel slot and use screws to secure them. Do not over-tighten
the screws. (g. 6 & 7)
7. Your vacuum comes ready for dry vacuum cleaning. For installation instructions, see page 9.
(g. 8 & 9)
8. For wet vacuum cleaning, install the supplied foam lter. (g. 10) For installation instructions,
see page 10.
9. Place the power head back on the collection tank, aligning the top section with the latches, and
snap into place. (g. 11)
10. Insert the handle into the slots located on the top of the power head and secure it with the
screws provided. Do not over-tighten the screws. (g. 12)
11. Hang the tool caddy onto the hooks on the back of the vacuum. (g. 13)
12. Secure the large end of the hose onto the vacuum port on the collection tank and screw into
place. (g. 14)
13. Choose the desired accessories and push onto the hose. (g. 15)
A Philips head screw driver is required.
POLARIZED PLUG
To reduce the risk of electrical shock, this appliance has a polarized plug (one blade wider than the
other). This plug will t in a polarized outlet only one way. If the plug does not t fully in the outlet,
reverse the plug. If it still does not t, contact a qualied electrician to install the proper outlet.
Do not change the plug in any way. Double insulation eliminates the need for the three wire
grounded power cord and grounded power supply system.
1 3 4 56
8910
14 15
1
1
7
2
2
13
2
11 12
7
DRY VACUUM OPERATION
1 2 3 5
12
6
8 9
711
4
10
DRY VACUUMING
WARNING: BE SURE TO READ, UNDERSTAND, AND APPLY, INFORMATION
ENTITLED ‘SAFETY INSTRUCTIONS & WARNINGS’. DO NOT VACUUM IN AREAS WITH
FLAMMABLE GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE
GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT
TYPE CLEANERS, OIL-BASED PAINTS, GASOLINE, ALCOHOL, OR AEROSOL SPRAYS.
EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO: COAL, MAGNESIUM, GRAIN,
OR GUN POWDER. TO REDUCE THE RISK OF HEALTH HAZARDS FROM VAPORS OR
DUST, DO NOT VACUUM TOXIC MATERIALS.
1. Verify that the power cord is disconnected from the outlet. (g.1)
2. In order to prepare your vacuum for dry vacuuming, verify that the cartridge lter is securely
mounted. Make sure the lter is pushed in until it stops against the power head. (g. 2) Your
Wet/Dry Vac comes with the cartridge lter pre-installed. For installation instructions, see page
9.
3. Place lter retainer on top of cartridge lter and tighten by turning the retainer handle
clockwise. (g. 3)
4. Optional: For improved dust ltering, t collection bag ange onto the inlet port, taking care not
to damage the bag. Dust bag sold separately. (g. 4)
5. Place the power head back on the collection tank, aligning the top section with the latches, and
lock into place. (g. 5)
OPERATING INSTRUCTIONS: DRY VACUUMING
6. Insert the locking end of the hose into the vacuum port on the power head and screw in place.
Push the desired extension wands or attachments onto the free end of the hose. (g. 6)
7. Verify that the switch is in the ‘O’ OFF position before plugging the power cord into the outlet.
(g. 7 & 8)
8. Turn the motor on by ipping the switch to the ‘I’ ON position. (g. 9)
9. Once you have completed vacuuming, ip the switch to the ‘O’ OFF position and unplug the
power cord from the outlet. (g. 10 & 11)
10. To rewind the cord, hold on to the plug and press the cord rewind button. Do not allow plug to
whip when rewinding. (g. 12)
O = OFF I = ON
DO NOT USE THE CARTRIDGE FILTER FOR LIQUID VACUUMING.
DO NOT USE DUST BAG FOR LIQUID VACUUMING.
8
LIQUID VACUUM OPERATION
LIQUID VACUUMING
WARNING: BE SURE TO READ, UNDERSTAND, AND APPLY, INFORMATION
ENTITLED ‘SAFETY INSTRUCTIONS & WARNINGS’. DO NOT VACUUM IN AREAS WITH
FLAMMABLE GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE
GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT
TYPE CLEANERS, OIL-BASED PAINTS, GASOLINE, ALCOHOL, OR AEROSOL SPRAYS.
EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO: COAL, MAGNESIUM, GRAIN,
OR GUN POWDER. TO REDUCE THE RISK OF HEALTH HAZARDS FROM VAPORS OR
DUST, DO NOT VACUUM TOXIC MATERIALS.
WARNING: DO NOT PLUG POWER CORD INTO POWER OUTLET. MAKE SURE PLUG
IS DISCONNECTED BEFORE CHANGING THE FILTERS.
2 3
9
56
4
710
8
1. Verify that the power cord is disconnected from the outlet. Verify that the collection tank is clean
and free of dust and dirt. (g. 1)
2. Remove cartridge lter and the dust collection bag, then carefully install the foam wet lter over
the lter cage and place the power head back on the collection tank. (g. 2) For installation
instructions, see page 10.
DO NOT USE THE CARTRIDGE FILTER FOR LIQUID VACUUMING.
OPERATING INSTRUCTIONS: WET VACUUMING
3. Fit the desired extension wands or nozzle to the vacuum hose. (g. 3)
4. Verify that the switch is in the ‘O’ OFF position before plugging the power cord into the outlet. (g.
4 & 5)
5. Turn the motor on by ipping the switch to the ‘I’ ON position. (g. 6)
6. After use, ip the switch to the ‘O’ OFF position and unplug the power cord from the outlet. (g.
7 & 8)
7. Empty the collection tank into a suitable receptacle or drain. (g. 9)
8. To rewind the cord, hold on to the plug and press the cord rewind button. Do not allow plug to
whip when rewinding. (g. 10)
IMPORTANT! When vacuuming large quantities of liquids, do not immerse the nozzle completely
in the liquid; leave a gap at the tip of the nozzle opening to allow air inow. The machine is tted
with a oat valve that stops the suction action when the collection tank reaches its maximum
capacity. You will notice an increase in motor speed. When this happens, turn off the machine,
disconnect from power supply, and drain the liquid into a suitable receptacle or drain. After wet
vacuuming, turn the machine off and remove plug from power supply. Empty the collection tank,
9
MAINTENANCE
1. Verify that the power cord is disconnected from the outlet. (g.1)
2. Disconnect the hose from the vacuum. (g. 2)
3. Undo the latches and remove the power head from the collection tank. (g. 3)
4. Clear all dirt or debris from the collection tank and hose. (g. 4)
5. Clean the foam lter by washing it with water and mild soap. (g. 5)
6. Check the hose, attachments, and power cord to verify that they have not been damaged.
7. Place power head on collection tank and secure latches.
IMPORTANT! Clean or change the cartridge lter regularly for best performance. ALWAYS USE
CARTRIDGE FILTER FOR DRY VACUUMING. If the machine is used without the cartridge lter,
the motor will burn out and the warranty will be voided. Always keep spare lters on hand.
NOTICE! The lters included are made of high quality materials designed to stop small dust
particles. The cartridge lter should be used for dry pick-up only. A dry cartridge lter is necessary
to pick up dust. If the cartridge lter is wet, it will clog quickly and be very difcult to clean. Handle
the lter carefully when removing it for cleaning and replacing it. Check the lters for tears or small
holes, a small hole can let dust pass through and out of the lter. Do not use a lter with holes or
tears in it; replace it immediately.
WARNING! ALWAYS DISCONNECT THE PLUG FROM THE POWER OUTLET BEFORE
REMOVING THE POWER HEAD FROM THE COLLECTION TANK.
12345
clean and dry the inside and outside before storage. REMEMBER! The foam wet lter must be
removed after wet vacuuming, and a cartridge lter must be installed before dry vacuuming again.
10
2 3 4 5 61
3 42
8
5 6
7
1
Installing Cartridge Filter
1. Verify that the power cord is disconnected from the outlet. (g. 1)
2. Remove power head and place in upside down position.
3. Install the cartridge lter over the lter cage and carefully push lter in until it stops against the
power head. (g. 2 & 3)
4. Place lter retainer on top of cartridge lter and tighten down by turning retainer clockwise. (g.
4 & 5)
Removing and Cleaning Cartridge Filter
1. Unlock and remove the lter retainer by turning retainer handle counter clockwise.
2. Carefully hold and pull the cartridge lter up for removal. (g. 6)
3. Clean the cartridge lter by gently tapping or brushing dirt off. Cleaning should not be done
indoors in living areas. For optimal performance a new lter is recommended.
4. Install cleaned or new lter as instructed above in steps 1 - 4 of Installing Cartridge Filter.
5. Wet lters should be removed and allowed to air dry for 24 hours before installing onto the lter
cage.
Installing and Cleaning HEPA Filter
1. Verify that the power cord is disconnected from the outlet. (g. 1)
2. Unlock the lter door by lifting the lock tab UP to the unlocked position and pull the door out. (g.
2 & 3)
3. Remove the HEPA lter cartridge from the vacuum. (g. 4)
4. Clean lter by brushing dirt off. For optimal performance a new lter is recommended. (g. 5)
5. Install the cleaned or new lter. (g. 6)
6. Insert the lter door tabs into the upper slots and lock the lter door into place. (g. 7 & 8)
INSTALLING & CLEANING CARTRIDGE
FILTER
11
2 3 4 5
1
Installing Foam Wet Filter
1. Verify that the power cord is disconnected from the outlet. (g. 1)
2. Remove power head and place in upside down position. Follow instructions to remove cartridge
lter.
3. Carefully slide foam wet lter down over the lter cage making sure the cage is completely
covered. (g. 2 & 3)
4. Place the power head onto the collection tank.
Cleaning Foam Wet Filter
1. With the removed power head in an upside down position, carefully remove foam wet lter. (g.
4)
2. Use a mild soap and water solution to wash foam wet lter and rinse with clean water. (g. 5)
3. Allow lter to air dry before installing and using again.
INSTALLING & CLEANING FOAM WET
FILTER
TROUBLESHOOTING
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE
TROUBLESHOOTING
Symptom Possible Causes Corrective Action
Vacuum will not operate.
1) No power supply. 1) Check power supply – cord,
breakers, fuses.
2) Faulty power cord. 2) Unplug and check the
power cord. If damaged,
have it repaired by a
professional.
3) Collection tank full. 3) Empty collection tank.
Dust comes from motor cover. 1) The dust lter is missing or
damaged.
1) Attach or replace dust lter.
Reduced efciency and motor/
speed vibration.
1) There is a blockage in the
nozzle or hose, or the
collection tank inlet. Or dust
lter blocked by ne dust.
1) Check nozzle, hose and
collection tank inlets for
blockage. Take off the lter
and clean it or install a new
lter.
12
EXPLODED VIEW
13
PARTS LIST
Part Part Number Description Quantity
1 551009101 Handle Assembly 1
2 551013103 Hose Storage Rack 2
3Power Head Assembly 1
4 551013104 Float 1
5 551009103 Filter Basket 1
6 551001111 Latch Assembly 2
7Collection Tank 1
8 551009106 Rear Wheel Assembly A 1
9 551009108 Front Casters 2
10 551009109 Rear Wheel Assembly B 1
11 551003109 1-1/4" Extension Wand 3
12 551004115 1-1/4" Multi-Surface Floor Nozzle 1
13 551004114 1-1/4" Crevice Tool 1
14 551004116 1-1/4" Round Dust Brush 1
15 551004113 1-1/4" 2-in-1 Utility Nozzle 1
16 551009110 Hose 1
17 551001112 Accessory Storage Caddy 1
18 551009111 Foam Wet Filter 1
19 551009104 Cartridge Filter 1
20 551009105 Cartridge Filter Retainer 1
Wet-Dry-Vac.com Site Copyright ©2023 Christopher Komuves
This manual was downloaded from
wet-dry-vac.com
The most comprehensive source of information
about wet/dry shop vacuums on the Internet!
Wet-dry-vac.com allows you to
learn about how to purchase a
wet/dry vac, compare and
review detailed specifications
on hundreds of models, and
find compatible filters.
You can also view manuals,
parts lists and brochures for
hundreds of models. Plus,
you can find the best prices
for vacuums and filters, and
purchase online right from the
site.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Vacmaster VF408 Wet or Dry Shop Vacuum Cleaner Owner's manual

Category
Vacuum cleaners
Type
Owner's manual

Ask a question and I''ll find the answer in the document