X2E XORAYA DATACUBE-N3 User manual

  • Hello! I am an AI chatbot trained to assist you with the X2E XORAYA DATACUBE-N3 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
XORAYA DATACUBE-N3
User Manual
Version: 1.1 / March 2020
© 2020 X2E GmbH
This user manual is protected by copyright; all usual rights reserved. Reproduction of this user manual, even in
part, is only permitted with the approval of X2E GmbH. Any infringement will result in liability for damages and
may result in criminal prosecution.
All product names and brands used in this user manual are the property of their respective owners.
User Manual XORAYA DATACUBE-N3
3
Table of contents
Introduction ............................................................................................. 4
Intended use ............................................................................................ 4
Delivery contents ..................................................................................... 4
Safety ...................................................................................................... 5
Safety labels on the device ...................................................................... 5
General safety instructions ...................................................................... 5
Connections and controls ........................................................................ 6
Installation ............................................................................................... 9
Mounting .................................................................................................. 9
Connecting ............................................................................................... 9
XORAYASuite .......................................................................................... 11
Network settings .................................................................................... 12
Download .............................................................................................. 14
Hdd-Download ....................................................................................... 14
Automatic download service .................................................................. 17
Update firmware .................................................................................... 19
Cleaning ................................................................................................ 20
Repair ................................................................................................... 20
Transport............................................................................................... 20
Disposal ................................................................................................ 20
User Manual XORAYA DATACUBE-N3
4
Introduction
Intended use
The XORAYA DATACUBE-N3 is a fast read-out station for XORAYA RSUs (Removable Storage
Units). A terminal or PC can be used to access the contents of the storage medium.
The DATACUBE-N3 is designed for industrial areas and must not be used in residential areas.
You may only operate the DATACUBE-N3 within the scope of the technical specifications pro-
vided in this user manual. Additionally, the use in hazardous areas is not allowed.
The data lines may be extended up to a maximum of 30 m if they are sufficiently shielded. In
case of optical signal lines, the maximum length depends on the used transceivers and ca-
bles.
Delivery contents
XORAYA DATACUBE-N3 with mounting brackets
software
user manual
power cord
optionally: telescopic rails for rack mounting
optionally: XORAYA RSU(s)
Check to ensure that the delivery is complete and all parts are in sound condition. If the deliv-
ery is incomplete or supplied components are damaged, contact X2E immediately. Do not
use damaged components.
User Manual XORAYA DATACUBE-N3
5
Safety
Safety labels on the device
You find the following two safety labels on the XORAYA RSU front side.
Warning: Hot surface
Please note the safety instruction Burning hazard due to hot surfaces (see
chapter Connecting).
Read this user manual completely before using the device for the first time.
General safety instructions
The DATACUBE-N3 is only intended for use by qualified personnel.
CAUTION
Electric shock due to damaged components
Damages to the D
ATACUBE
-N3 or the power cord can result in electric
shock.
Check all components regularly for damages.
Only connect the DATACUBE-N3 if all components are undamaged.
CAUTION
Device damage due to vibrations, dirt or liquids
Excessive vibrations, dirt or liquids may result in malfunction or destruction
of the DATACUBE-N3.
Avoid exposing the DATACUBE-N3 to excessive vibrations, dirt or liq-
uids.
Keep the DATACUBE-N3 clean, especially plugs and sockets to en-
sure a reliable contact.
Never open the DATACUBE-N3.
CAUTION
Device damage due to electrostatic discharge
Electronic components can be destroyed by electrostatic discharge.
Avoid touching connectors and connector pins.
Never reach into the slot for the XORAYA RSU.
User Manual XORAYA DATACUBE-N3
6
Connections and controls
Front view
Back view
User Manual XORAYA DATACUBE-N3
7
Disk detected LED (A)
Illuminates blue when the connected XORAYA RSU is in its fully pushed-in position.
Disk active LED (B)
Illuminates yellow when data is transferred.
Power button (C)
When the DATACUBE-N3 is on, the power button illuminates green. Press the button twice
shortly to safely shut down the DATACUBE-N3 and unlock the XORAYA RSU.
Unlock button (D)
To avoid data loss, always press this button for at least one second before disconnecting the
XORAYA RSU. The integrated LED displays the connection state.
LED Meaning
red: connection enabled (locked)
green: connection disabled through button (unlocked)
Power input (E) and power switch (F)
Use the provided power cord to connect the DATACUBE-N3 to a suitable power source.
Technical data of the built-in power supply:
Power: 650 W
Input: 100 240 V AC, 50 60 Hz, 8 4 A
Service LAN port (G)
In case of errors, this port is used as a debugging interface by the X2E support team.
USB 2.0 (H) and USB 3.0 ports (I)
Perform a firmware update by using a USB flash drive containing the suitable ISO file.
User Manual XORAYA DATACUBE-N3
8
10GbE (J) and 40GbE LAN ports (K)
Use these ports to connect the DATACUBE-N3 to a switch or directly to your PC.
Compatibility of Ethernet standards
1GbE and 10GbE are principally compatible to each other. Use a switch in
between if there are connection problems.
The compatibility between 10GbE and 10/100Base-T is not guaranteed.
RJ45 port LEDs (J):
LED Colour Meaning
Activity (right) flashing green data is transferred
Link (left) green 10 Gbit/s
orange 1 Gbit/s
Supported QSFP+ transceiver modules and cables for the network interface card (K):
Chelsio SM40G-SR / SM40G-LR
Chelsio QTAPCABLE1M / QTAPCABLE3M / QTAPCABLE5M
FS Chelsio SM40G-SR Compatible 40GBASE-SR4 QSFP+ Transceiver Module
(MMF, 850nm, 150m, MTP/MPO, DOM)
FS Chelsio SM40G-IR Compatible 40GBASE-LR4L QSFP+ Transceiver Module
(SMF, 1310nm, 2km, LC, DOM)
FS Chelsio SM40G-BD Compatible 40GBASE-SR Bi-Directional Duplex Transceiver
Module (MMF, 832nm - 918nm, 150m, LC)
User Manual XORAYA DATACUBE-N3
9
Installation
Mounting
CAUTION
Device damage due to overheating
Overheating may result in malfunction or destruction of the D
ATACUBE
-N3.
Do not operate the DATACUBE-N3 in the vicinity of heat sources.
Ensure adequate air circulation.
Do not cover the air vents of the DATACUBE-N3 with other objects.
Notes on 19-inch rack mounting:
Due to the weight of the DATACUBE-N3, two people should perform the installation.
Use either the optionally available telescopic rails or a custom and safe fixing method.
The mounting brackets at the sides of the front panel serve as an additional fixation.
They are not suited as the sole means of mounting.
Connecting
XORAYA RSUs
CAUTION
Burning hazard due to hot surfaces
Continuous operation can strongly heat up housing and handle of the stor-
age medium XORAYA RSU. As a result, when removing the medium, it can
burn the skin on the hands.
Wear temperature-resistant ESD gloves when in contact with the XO-
RAYA RSU.
User Manual XORAYA DATACUBE-N3
10
CAUTION
Risk of injury due to sharp edges or falling down
Sharp edges can cause cuts. Due to the weight of the X
ORAYA
RSU, foot in-
juries are likely to occur when it falls down.
Wear temperature-resistant ESD gloves when in contact with the XO-
RAYA RSU.
Handle the XORAYA RSU with special care.
Insert the XORAYA RSU carefully with both hands into the slot.
Slowly push the XORAYA RSU until the stop is reached.
PC/Switch
When using the 40GbE LAN ports (K):
Pay attention to the correct orientation of the QSFP+ transceiver module and carefully
push it in until it locks in place.
Connect PC or switch via a standard network cable to one of the ports (J-K).
Ensure proper connector seating.
Power supply
CAUTION
Device damage due to wrong power supply
A wrong power supply can result in damage or destruction of the D
ATACUBE
-
N3.
Use the provided power cord.
Only connect the DATACUBE-N3 to power sources that meet the tech-
nical specifications.
Use the provided power cord to connect input (E) to a suitable power source.
Technical data for the built-in power supply:
Power: 650 W
Input: 100 240 V AC, 50 60 Hz, 8 4 A
Ensure proper connector seating.
Turn on the power switch (F).
User Manual XORAYA DATACUBE-N3
11
XORAYASuite
The graphical user interface XORAYASuite is available to configure and to control the
DATACUBE-N3.
Supported operating systems:
Microsoft® Windows® 7 (32 Bit or 64 Bit)
Microsoft® Windows® 8 (32 Bit or 64 Bit)
Microsoft® Windows® 10 (32 Bit or 64 Bit)
Hardware requirements:
Processor speed: at least 1 GHz
RAM: at least 2 GB
Hard disk space: approx. 120 MB available
Software requirements:
Microsoft® .NET Framework Version 4.5 or higher
Install XORAYASuite
Start the setup wizard and follow the instructions.
User Manual XORAYA DATACUBE-N3
12
Network settings
The XORAYASuite extra tool HWFinder enables access to a web interface to change the con-
figuration of the 10GbE (J) and 40GbE (K) LAN ports.
Start the XORAYASuite.
Click in the Windows notification area.
Select Extra tools > HWFinder.
Start web interface
In the drop-down list Device class, select DATACUBE.
Double-click the row of the desired DATACUBE-N3.
or
Highlight the row and click Web GUI.
The web interface opens in your browser.
Start web interface directly in browser
Alternatively, enter the IP address or the name of the DATACUBE-N3 directly
into the browser address bar to start the web interface.
User Manual XORAYA DATACUBE-N3
13
In the menu on the left side, select the category Network configuration.
Click the desired port in the graphic.
or
Click one of the tabs Port A to Port D.
Activate the Editmode.
Change the Mode and enter IP address, Subnet mask and Standard gateway if
needed.
Click Save.
User Manual XORAYA DATACUBE-N3
14
Download
The XORAYASuite offers tools to download log data from connected XORAYA RSUs.
Hdd-Download
Start the XORAYASuite.
Click Hdd-Download.
Connect DATACUBE-N3
Connect the DATACUBE-N3 to power source and PC and put one or more XORAYA
RSUs in (see chapter Connecting).
Press the power button (C).
The DATACUBE-N3 is ready when the power LED is green.
Click Display available loggers (1) to start scanning for dataloggers and DATACUBEs.
Select the desired DATACUBE-N3.
Click Establish connection to logger (2).
The DATACUBE-N3 is connected with the Hdd-Download tool. An additional window opens to
choose one from the connected storage units.
User Manual XORAYA DATACUBE-N3
15
Select XORAYA RSU
Click on the check mark of the desired storage unit.
Change RSU
To eject a XORAYA RSU or to activate another device, click Change disk (5).
Select log data
Specify start date (a) and start time (b) of the desired time range.
Specify the end date (c). Use the arrows (d) optionally to apply the start date or to
jump one day forward or backward.
Specify the end time (e).
Click Apply (f).
Limit the time range further by clicking and dragging inside the graphical representa-
tion (g).
History
The time ranges defined since starting the tool can be selected again via the
History button (h).
User Manual XORAYA DATACUBE-N3
16
Download selected log data
Specify the path.
Click Start download (4).
The log data within the selected time range are transmitted to the PC.
Statistical data
Click the arrow behind Show download statistics (8) to switch between dif-
ferent statistics.
The symbol displays the current value during download and the average as
the process completes.
Click Show download statistics (8) to display statistical data graphically.
Cancel download
Click Stop download from logger (4).
Analyse log data
Click (7) to open the last used folder in Windows Explorer.
Disconnect DATACUBE-N3
Click Release connection to logger (2).
DATACUBE-N3 and Hdd-Download are disconnected.
User Manual XORAYA DATACUBE-N3
17
Automatic download service
This XORAYASuite extra tool is a server, which automatically downloads log data from se-
lected DATACUBEs (and dataloggers).
Start the XORAYASuite.
Click in the Windows notification area.
Select Extra tools > DataCube.
Download settings
Click (3) to open the settings.
User Manual XORAYA DATACUBE-N3
18
In the category White list, select the devices for the automatic download service.
Click Refresh the device list (a) to search for DATACUBEs and dataloggers in the net-
work again.
Select the check boxes (b) for all devices that you want to add to the white list.
For a selected device, the symbol (c) changes from to if it is currently not reachable.
In the category Export, specify export settings and output formats.
In the category Measurement select, restrict the log data to download, for example by
setting a start date. Additionally, you can configure that, after downloading, log data is
automatically deleted from the XORAYA RSU and the RSU is unlocked.
After configuring all settings, click Accept.
Start server
Click Start Server (1).
After 5 seconds, the server scans for the selected devices, connects and automatically
downloads the log data.
Every 60 seconds, the server scans the network again for other devices from the white list
and downloads the log data.
Stop server
After completing the log data download from all desired devices, click Stop Server (2).
User Manual XORAYA DATACUBE-N3
19
Update firmware
Start the DATACUBE-N3 web interface (see chapter Network settings).
In the menu on the left side, select the category Firmware-Update.
Click Browse… (1) and select a suitable XSWU file.
Click Update (2).
Update firmware via USB flash drive
If the firmware update is available as an ISO file, write it to a USB flash drive
and insert the drive into one of the USB 3.0 ports (H-I). The DATACUBE-N3
automatically performs the firmware update. The web interface is not
needed.
User Manual XORAYA DATACUBE-N3
20
Cleaning
CAUTION
Device damage due to entering liquids
Entering liquids may result in malfunction or destruction of the D
ATACUBE
-
N3.
Disconnect the DATACUBE-N3 from the power source before clean-
ing.
Make sure that no liquids enter the DATACUBE-N3.
Clean the DATACUBE-N3 with a damp, soft cloth as needed.
Repair
CAUTION
Device damage from opening the device
Unauthorised opening may result in malfunction or destruction of the
DATACUBE-N3.
Never open the DATACUBE-N3.
Maintenance and repair must be carried out by X2E personnel only.
In case of malfunctions or damages, please contact X2E via e-mail to get information
about returning the DATACUBE-N3: xoraya-[email protected]
Transport
Always transport the DATACUBE-N3 without inserted XORAYA RSUs.
Use the front panel handles of the DATACUBE-N3.
Disposal
Within the European Union, the disposal of electrical devices is determined
by national rules that are based on the directive 2012/19/EU of the Euro-
pean Parliament and of the Council on waste electrical and electronic equip-
ment (WEEE). Accordingly, electrical and electronic equipment may not be
disposed of in household waste.
Outside the European Union, please contact your local authority so as to
comply with the correct method of disposal for electrical devices.
/